Your browser doesn't support javascript.
loading
A zinc-air battery assisted self-powered electrochemical sensor for sensitive detection of microcystin-RR.
Wang, Qianjun; Jiang, Ding; Du, Xiaojiao; Shan, Xueling; Wang, Wenchang; Shiigi, Hiroshi; Chen, Zhidong.
Afiliação
  • Wang Q; Jiangsu Key Laboratory of Advanced Catalytic Materials and Technology, School of Petrochemical Engineering, Changzhou University, Changzhou, Jiangsu, 213164, P. R. China. jiangding@cczu.edu.cn.
  • Jiang D; Jiangsu Key Laboratory of Advanced Catalytic Materials and Technology, School of Petrochemical Engineering, Changzhou University, Changzhou, Jiangsu, 213164, P. R. China. jiangding@cczu.edu.cn.
  • Du X; Oakland International Associated Laboratory, School of Photoelectric Engineering, Changzhou Institute of Technology, Changzhou, Jiangsu, 213032, P. R. China.
  • Shan X; Jiangsu Key Laboratory of Advanced Catalytic Materials and Technology, School of Petrochemical Engineering, Changzhou University, Changzhou, Jiangsu, 213164, P. R. China. jiangding@cczu.edu.cn.
  • Wang W; Jiangsu Key Laboratory of Advanced Catalytic Materials and Technology, School of Petrochemical Engineering, Changzhou University, Changzhou, Jiangsu, 213164, P. R. China. jiangding@cczu.edu.cn.
  • Shiigi H; Analysis and Testing Center, NERC Biomass of Changzhou University, Jiangsu, 213032, PR China.
  • Chen Z; Department of Applied Chemistry, Osaka Metropolitan University, 1-1 Gakuen, Naka, Sakai, Osaka 599-8531, Japan.
Analyst ; 149(8): 2291-2298, 2024 Apr 15.
Article em En | MEDLINE | ID: mdl-38511612
ABSTRACT
Building a high-performance sensing platform is the key to developing sensitive sensors. Herein, a highly sensitive self-powered electrochemical sensor (SPES) was constructed using a WO3·H2O film as the cathode prepared by a hydrothermal method and Zn as the anode, and it could be applied to sensitive detection of microcystin (MC-RR). The WO3·H2O film with a larger specific surface area could boost the oxygen reduction reaction (ORR), which could achieve signal amplification and significantly increase the sensitivity of the sensors. Under the optimal conditions, there was a good linear relationship between the increased electrical power density and the logarithm of MC-RR concentration with a detection limit of 1.31 × 10-15 M (S/N = 3). This method had good anti-interference ability and stability when applied to the determination of MC-RR content in actual samples, which could boost the potential application of electrochemical sensors in the field of environmental monitoring.

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Analyst Ano de publicação: 2024 Tipo de documento: Article