Your browser doesn't support javascript.
loading
Evaluation of changes of anterior segment parameters in patients with pseudoexfoliation syndrome after cataract surgery using anterior segment optical coherence tomography.
Wlaz, Aleksandra; Kustra, Agnieszka; Aung, Tin; Zarnowski, Tomasz.
Afiliação
  • Wlaz A; Department of Diagnostics and Microsurgery of Glaucoma, Medical University, Chmielna 1, 20-079, Lublin, Poland. aleksandra.wlaz@icloud.com.
  • Kustra A; Optegra Eye Clinic, Gesia 5, 20-719, Lublin, Poland. aleksandra.wlaz@icloud.com.
  • Aung T; Department of Diagnostics and Microsurgery of Glaucoma, Medical University, Chmielna 1, 20-079, Lublin, Poland.
  • Zarnowski T; Singapore Eye Research Institute & Singapore National Eye Centre, Singapore, Singapore.
Sci Rep ; 14(1): 8279, 2024 04 09.
Article em En | MEDLINE | ID: mdl-38594403
ABSTRACT
The aim of the study was to compare the anterior segment parameters after cataract surgery in pseudoexfoliation syndrome (PEX) and control eyes. We conducted a prospective comparative study of 36 eyes (PEX group), 16 eyes (PEXG group) and 46 eyes (control group) of 98 patients after phacoemulsification with intraocular lens implantation. Before surgery, 1 week, 1 month and 3 months postoperatively, anterior chamber parameters were evaluated by swept source anterior segment optical coherence tomography (AS-OCT). Anterior chamber depth (ACD), angle opening distance (AOD500/750), trabecular-iris space area (TISA500/750), trabecular-iris angle (TIA500/750) and lens vault (LV) were assessed at each study visit. Preoperatively, ACD, AOD500/750 and TISA500/750 were significantly smaller, while LV was significantly greater in PEX and PEXG eyes than in controls. 3 months postoperatively all irido-corneal parameters and ACD were significantly greater in all study groups without intergroup differences. ACD and LV significantly increased in PEX group between 1 and 3 months after surgery while being stable in control group. Relative increases in ACD, AOD500, TISA750, TIA500/750 were significantly higher in PEX and PEXG groups than in controls. Our study finds that ACD and iridocorneal parameters in AS-OCT demonstrated significantly greater relative increases 3 months after phacoemulsification in PEX and PEXG groups than in control eyes. Significantly greater deepening of anterior chamber and opening of the irido-corneal angle may be a reason for different refractive outcomes and IOP control in patients with PEX and PEXG after routine cataract surgery.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Catarata / Síndrome de Exfoliação Limite: Humans Idioma: En Revista: Sci Rep Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Polônia

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Catarata / Síndrome de Exfoliação Limite: Humans Idioma: En Revista: Sci Rep Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Polônia