Your browser doesn't support javascript.
loading
Iridium(III) solvent complex-based electrogenerated chemiluminescence method for the detection of 3-methylhistidine in urine.
Liu, Yu; Li, Yue; Qian, Manping; Wu, Yang; Li, Meng; Zhang, Chengxiao; Qi, Honglan.
Afiliação
  • Liu Y; Key Laboratory of Analytical Chemistry for Life Science of Shaanxi Province, School of Chemistry and Chemical Engineering, Shaanxi Normal University, Xi'an, 710062, People's Republic of China.
  • Li Y; Key Laboratory of Analytical Chemistry for Life Science of Shaanxi Province, School of Chemistry and Chemical Engineering, Shaanxi Normal University, Xi'an, 710062, People's Republic of China.
  • Qian M; Key Laboratory of Analytical Chemistry for Life Science of Shaanxi Province, School of Chemistry and Chemical Engineering, Shaanxi Normal University, Xi'an, 710062, People's Republic of China.
  • Wu Y; Key Laboratory of Analytical Chemistry for Life Science of Shaanxi Province, School of Chemistry and Chemical Engineering, Shaanxi Normal University, Xi'an, 710062, People's Republic of China.
  • Li M; Key Laboratory of Analytical Chemistry for Life Science of Shaanxi Province, School of Chemistry and Chemical Engineering, Shaanxi Normal University, Xi'an, 710062, People's Republic of China.
  • Zhang C; Key Laboratory of Analytical Chemistry for Life Science of Shaanxi Province, School of Chemistry and Chemical Engineering, Shaanxi Normal University, Xi'an, 710062, People's Republic of China.
  • Qi H; Key Laboratory of Analytical Chemistry for Life Science of Shaanxi Province, School of Chemistry and Chemical Engineering, Shaanxi Normal University, Xi'an, 710062, People's Republic of China. honglanqi@snnu.edu.cn.
Anal Bioanal Chem ; 416(21): 4705-4715, 2024 Sep.
Article em En | MEDLINE | ID: mdl-38937290
ABSTRACT
3-Methylhistidine (3-MeHis) is increasingly used as an indicator of muscle protein breakdown. The development of a sensitive, simple, and non-invasive method for 3-MeHis assay is important in clinical practice. Herein, a sensitive, simple, and non-invasive electrogenerated chemiluminescence (ECL) method was proposed for the quantitation of 3-MeHis in urine by using an iridium(III) solvent complex ([Ir(dfppy)2(DMSO)Cl], dfppy = 2-(2,4-difluorophenyl)pyridine, Ir-DMSO) as a signal reagent. The photoluminescence (PL) and ECL responses of Ir-DMSO to 3-MeHis were studied. The ECL intensity of Ir-DMSO was enhanced in the presence of 3-MeHis because of the coordination recognition between Ir-DMSO and the imidazole group of 3-MeHis. Based on the enhancement of ECL intensity, 3-MeHis can be sensitively detected in the range of 5 to 25 µM. The detection limit was 0.4 µM. This is the first report of an ECL method for the quantitation of 3-MeHis. Further, to investigate the feasibility of the Ir-DMSO-based ECL method in practical applications, the developed ECL method was applied for 3-MeHis assay in urine samples of 28 healthy volunteers and 2 patients. The urine samples from patients hospitalized with obesity and kidney disease and healthy individuals were distinguished by the ECL responses of Ir-DMSO. The proposed ECL method based on the coordination recognition between iridium(III) solvent complex and the imidazole group of 3-MeHis allows inexpensive, fast, non-invasive, and sensitive detection of 3-MeHis in urine, which is promising for assessing large volumes of patients for routine analysis in clinical practices.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Solventes / Limite de Detecção / Irídio / Medições Luminescentes / Metilistidinas Limite: Humans / Male Idioma: En Revista: Anal Bioanal Chem Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Solventes / Limite de Detecção / Irídio / Medições Luminescentes / Metilistidinas Limite: Humans / Male Idioma: En Revista: Anal Bioanal Chem Ano de publicação: 2024 Tipo de documento: Article