Your browser doesn't support javascript.
loading
Open Access Data and Deep Learning for Cardiac Device Identification on Standard DICOM and Smartphone-based Chest Radiographs.
Busch, Felix; Bressem, Keno K; Suwalski, Phillip; Hoffmann, Lena; Niehues, Stefan M; Poddubnyy, Denis; Makowski, Marcus R; Aerts, Hugo J W L; Zhukov, Andrei; Adams, Lisa C.
Afiliação
  • Busch F; From the Department of Radiology (F.B., L.H., S.M.N.), Department of Anesthesiology, Division of Operative Intensive Care Medicine (F.B.), Department of Cardiology (P.S.), and Department of Rheumatology (K.B.B., D.P., A.Z.), Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität B
  • Bressem KK; From the Department of Radiology (F.B., L.H., S.M.N.), Department of Anesthesiology, Division of Operative Intensive Care Medicine (F.B.), Department of Cardiology (P.S.), and Department of Rheumatology (K.B.B., D.P., A.Z.), Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität B
  • Suwalski P; From the Department of Radiology (F.B., L.H., S.M.N.), Department of Anesthesiology, Division of Operative Intensive Care Medicine (F.B.), Department of Cardiology (P.S.), and Department of Rheumatology (K.B.B., D.P., A.Z.), Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität B
  • Hoffmann L; From the Department of Radiology (F.B., L.H., S.M.N.), Department of Anesthesiology, Division of Operative Intensive Care Medicine (F.B.), Department of Cardiology (P.S.), and Department of Rheumatology (K.B.B., D.P., A.Z.), Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität B
  • Niehues SM; From the Department of Radiology (F.B., L.H., S.M.N.), Department of Anesthesiology, Division of Operative Intensive Care Medicine (F.B.), Department of Cardiology (P.S.), and Department of Rheumatology (K.B.B., D.P., A.Z.), Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität B
  • Poddubnyy D; From the Department of Radiology (F.B., L.H., S.M.N.), Department of Anesthesiology, Division of Operative Intensive Care Medicine (F.B.), Department of Cardiology (P.S.), and Department of Rheumatology (K.B.B., D.P., A.Z.), Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität B
  • Makowski MR; From the Department of Radiology (F.B., L.H., S.M.N.), Department of Anesthesiology, Division of Operative Intensive Care Medicine (F.B.), Department of Cardiology (P.S.), and Department of Rheumatology (K.B.B., D.P., A.Z.), Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität B
  • Aerts HJWL; From the Department of Radiology (F.B., L.H., S.M.N.), Department of Anesthesiology, Division of Operative Intensive Care Medicine (F.B.), Department of Cardiology (P.S.), and Department of Rheumatology (K.B.B., D.P., A.Z.), Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität B
  • Zhukov A; From the Department of Radiology (F.B., L.H., S.M.N.), Department of Anesthesiology, Division of Operative Intensive Care Medicine (F.B.), Department of Cardiology (P.S.), and Department of Rheumatology (K.B.B., D.P., A.Z.), Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität B
  • Adams LC; From the Department of Radiology (F.B., L.H., S.M.N.), Department of Anesthesiology, Division of Operative Intensive Care Medicine (F.B.), Department of Cardiology (P.S.), and Department of Rheumatology (K.B.B., D.P., A.Z.), Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität B
Radiol Artif Intell ; 6(5): e230502, 2024 Sep.
Article em En | MEDLINE | ID: mdl-39017033
ABSTRACT
Purpose To develop and evaluate a publicly available deep learning model for segmenting and classifying cardiac implantable electronic devices (CIEDs) on Digital Imaging and Communications in Medicine (DICOM) and smartphone-based chest radiographs. Materials and Methods This institutional review board-approved retrospective study included patients with implantable pacemakers, cardioverter defibrillators, cardiac resynchronization therapy devices, and cardiac monitors who underwent chest radiography between January 2012 and January 2022. A U-Net model with a ResNet-50 backbone was created to classify CIEDs on DICOM and smartphone images. Using 2321 chest radiographs in 897 patients (median age, 76 years [range, 18-96 years]; 625 male, 272 female), CIEDs were categorized into four manufacturers, 27 models, and one "other" category. Five smartphones were used to acquire 11 072 images. Performance was reported using the Dice coefficient on the validation set for segmentation or balanced accuracy on the test set for manufacturer and model classification, respectively. Results The segmentation tool achieved a mean Dice coefficient of 0.936 (IQR 0.890-0.958). The model had an accuracy of 94.36% (95% CI 90.93%, 96.84%; 251 of 266) for CIED manufacturer classification and 84.21% (95% CI 79.31%, 88.30%; 224 of 266) for CIED model classification. Conclusion The proposed deep learning model, trained on both traditional DICOM and smartphone images, showed high accuracy for segmentation and classification of CIEDs on chest radiographs. Keywords Conventional Radiography, Segmentation Supplemental material is available for this article. © RSNA, 2024 See also the commentary by Júdice de Mattos Farina and Celi in this issue.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Radiografia Torácica / Desfibriladores Implantáveis / Smartphone / Aprendizado Profundo Limite: Adolescent / Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: Radiol Artif Intell Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Radiografia Torácica / Desfibriladores Implantáveis / Smartphone / Aprendizado Profundo Limite: Adolescent / Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: Radiol Artif Intell Ano de publicação: 2024 Tipo de documento: Article