Your browser doesn't support javascript.
loading
Integrated spectroscopic approaches for the facile one pot quantification of olanzapine in pharmaceutical formulation and spiked human plasma.
Samir, Ebtihal; Derayea, Sayed M; Badr-Eldin, Khaled M; Madian, Huda; Hamad, Ahmed Abdulhafez.
Afiliação
  • Samir E; Pharmaceutical Analytical Chemistry Department, Deraya University, New Minia, Minia 61519, Egypt.
  • Derayea SM; Analytical Chemistry Department, Faculty of Pharmacy, Minia University, Minia 61519, Egypt. Electronic address: sayed_derayea@mu.edu.eg.
  • Badr-Eldin KM; Analytical Chemistry Department, Faculty of Pharmacy, Minia University, Minia 61519, Egypt.
  • Madian H; Pharmaceutical Analytical Chemistry Department, Deraya University, New Minia, Minia 61519, Egypt; Analytical Chemistry Department, Faculty of Pharmacy, Minia University, Minia 61519, Egypt.
  • Hamad AA; Department of Pharmaceutical Analytical Chemistry, Faculty of Pharmacy, Al-Azhar University, Assiut Branch, Assiut 71524, Egypt.
Spectrochim Acta A Mol Biomol Spectrosc ; 322: 124838, 2024 Dec 05.
Article em En | MEDLINE | ID: mdl-39032233
ABSTRACT
In this work, the xanthene dye, erythrosine B, was employed as a probe for the determination of olanzapine using two fast and highly simple analytical approaches. The assay was based on the formation of a binary complex between the drug and erythrosine B in a slightly acidic aqueous buffered solution. In the first method, the absorbance of the formed product was monitored at 558 nm. The reaction stoichiometry was investigated, and the stability constant of the formed complex was estimated. The linear range of the method that obeyed Beer's law was in the concentration range of 0.6-8.0 µg/ml. The calculated detection and quantitation limits were 0.2 and 0.6 µg/mL. Upon adding the drug solution to erythrosine B, the native fluorescence of the dye was quenched and monitored at 550 nm after excitation at 528 nm. Thus, the fluorescence quenching was utilized as the quantitative signal in the spectrofluorimetric approach. The extent of quenching in the fluorescence intensity was rectilinear with the drug concentration in a range of 0.1-2.5 µg/ml with a detection limit of 0.032 µg/ml. Both approaches were analytically validated based on the guiding rules of the ICH with acceptable results, and were utilized efficiently in the analysis of olanzapine in commercial tablets containing the cited drug. In addition, owing to its high sensitivity and selectivity, the spectrofluorimetric method was applied for drug analysis in spiked human plasma with satisfactory % recoveries. Finally, the greenness of the methods was confirmed using eco-score scale and Analytical Green Evaluation metrics.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Espectrometria de Fluorescência / Limite de Detecção / Olanzapina Limite: Humans Idioma: En Revista: Spectrochim Acta A Mol Biomol Spectrosc Assunto da revista: BIOLOGIA MOLECULAR Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Egito

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Espectrometria de Fluorescência / Limite de Detecção / Olanzapina Limite: Humans Idioma: En Revista: Spectrochim Acta A Mol Biomol Spectrosc Assunto da revista: BIOLOGIA MOLECULAR Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Egito