Your browser doesn't support javascript.
loading
Normal ultrasonic myocardial reflectivity in hypertensive patients. A tissue characterization study.
Gigli, G; Lattanzi, F; Lucarini, A R; Picano, E; Genovesi-Ebert, A; Marabotti, C; Zunino, R; Mazzarisi, A; Landini, L; Iannetti, M.
Afiliação
  • Gigli G; Istituto di Fisiologia Clinica, CNR, Pisa, Italy.
Hypertension ; 21(3): 329-34, 1993 Mar.
Article em En | MEDLINE | ID: mdl-8478042
ABSTRACT
Ultrasonic backscatter of myocardial walls is directly related to the morphometrically evaluated collagen content in humans. The integrated backscatter is also increased in hypertrophic cardiomyopathy, whereas it gives normal values in the physiological hypertrophy of elite athletes. We assessed the quantitatively evaluated myocardial reflectivity in 46 mild to moderate, clinically uncomplicated essential hypertensive patients, with echocardiographically assessed normal regional and global left ventricular function, and 22 age- and sex-matched normotensive control subjects. With an echo prototype implemented in our institute, we performed an on-line radiofrequency analysis to obtain quantitative operator-independent measurements of the integrated backscatter signal of the ventricular septum and posterior wall. The integrated values of the radiofrequency signal of myocardial walls were normalized for those of the pericardial interface and expressed as a percent (integrated backscatter index). Hypertensive patients and control subjects differed in mean blood pressure (119 +/- 11 versus 95 +/- 5 mm Hg, p < 0.001) and left ventricular mass index (134 +/- 31 versus 105 +/- 21 g/m2, p < 0.001). However, integrated backscatter index overlapped for both the septum (28 +/- 17% versus 25 +/- 6%, p = NS) and the posterior wall (13 +/- 7% versus 13 +/- 4%, p = NS). In the hypertensive group, there was no detectable correlation between septal integrated backscatter index and either septal thickness (r = -0.26, p = NS) or mean arterial pressure (r = -0.14, p = NS). Hypertensive patients showed a normal pattern of quantitatively assessed ultrasonic backscatter, even in the presence of left ventricular hypertrophy.(ABSTRACT TRUNCATED AT 250 WORDS)
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Ecocardiografia / Hipertensão Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Hypertension Ano de publicação: 1993 Tipo de documento: Article País de afiliação: Itália
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Ecocardiografia / Hipertensão Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Hypertension Ano de publicação: 1993 Tipo de documento: Article País de afiliação: Itália