Your browser doesn't support javascript.
loading
Assessment of stenosis severity using a novel method to estimate spatial and temporal variations of blood flow velocity in biplane coronarography.
Sarry, L; Boire, J Y; Zanca, M; Lusson, J R; Cassagnes, J.
Afiliação
  • Sarry L; ERIM, INSERM U71, Clermont-Ferrand, France.
Phys Med Biol ; 42(8): 1549-64, 1997 Aug.
Article em En | MEDLINE | ID: mdl-9279905
ABSTRACT
The authors present a novel method to estimate absolute blood flow velocity in coronary arteries from biplane angiograms. Spatial and temporal velocity variations are derived giving simultaneously a direct geometric and an indirect functional index of stenosis severity, stenosis ratio and coronary flow reserve. No prior assumption concerning stenosis geometry is made. Deformable models are used to track a coronary artery segment dynamically in three dimensions. A densitometric map is obtained by summing densities across sections at every position along the previously calculated path and at every time of the cardiac cycle. An advection relationship between density and velocity is observed. The spatiotemporal velocity map is a solution of a nonlinear least-squares scheme. A simulation protocol based on simple geometric conformations and blood flow properties is used to assess numerical stability and immunity towards noise. Predicted results for temporal velocity variations are compared with the intracoronary Doppler recordings to test the model assumptions for basal state and hyperaemia examinations of the same patient. The stenosis ratio was accurate to within 3% for a simulated additive Gaussian noise with a standard deviation of 0.14. The limits of agreement between angiographic and Doppler velocities were -11.4 and 11.8 cm s-1 for a peak value of 23 cm s-1 (basal state) and -16.8 and 13.5 cm s-1 for a peak value of 52 cm s-1 (hyperaemia), corresponding to 18 and 3.5% errors on the average peak values and a 16% error on the coronary flow reserve. To summarize, the advection model derivation and its solution are presented. Simulated and experimental results corroborate the validity of the numerical schemes and support clinical applicability.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Velocidade do Fluxo Sanguíneo / Angiografia Coronária / Imagens de Fantasmas / Doença das Coronárias / Vasos Coronários Tipo de estudo: Diagnostic_studies / Guideline / Prognostic_studies Limite: Humans Idioma: En Revista: Phys Med Biol Ano de publicação: 1997 Tipo de documento: Article País de afiliação: França
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Velocidade do Fluxo Sanguíneo / Angiografia Coronária / Imagens de Fantasmas / Doença das Coronárias / Vasos Coronários Tipo de estudo: Diagnostic_studies / Guideline / Prognostic_studies Limite: Humans Idioma: En Revista: Phys Med Biol Ano de publicação: 1997 Tipo de documento: Article País de afiliação: França