Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Eur J Clin Microbiol Infect Dis ; 42(11): 1327-1335, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37749274

RESUMEN

Toxoplasmosis is a ubiquitous parasitic infection caused by Toxoplasma gondii (Tg). In immunocompetent people, the infection may be asymptomatic with the induction of an immune response that may prevent reinfection or transmission to the fetus in immune pregnant woman. In immunocompromised persons or seronegative pregnant woman with a primary infection during pregnancy, the infection may result in the loss of life, sight, cognition, and motor function in the immune-compromised person or immunologically immature fetus. The objective of this study was to evaluate a new immunochromatographic test Toxoplasma ICT IgG-IgM (ICT) that allows detection of specific anti-Tg immunoglobulins G (Ig G) and M (Ig M). We included 1145 prospectively obtained sera and 376 samples selected for specificity or sensitivity studies. The performance of ICT was compared using Vidas® Toxo Competition (TXC) and Toxoscreen®. In case of discrepancy, Vidas® Toxo Ig G or Ig M and LDBIO Toxo II IgG western blot were used to establish definitive results by additional methods. Sensitivity and specificity of ICT were respectively 99.3% and 100%. In comparison, Toxoscreen®'s sensitivity was 100% and the specificity was 99.8%. TXC had a sensitivity of 98.7% with a specificity of 99.1%. ICT has excellent performance even for low Ig G titers, especially in immunocompromised patients, and confirms the specificity of isolated Ig M. This ICT provides reliable results easily and quickly. This screening technique is not designed to differentiate the Ig M from Ig G. When positive, additional tests may be necessary.

2.
J Clin Microbiol ; 60(12): e0120422, 2022 12 21.
Artículo en Inglés | MEDLINE | ID: mdl-36448814

RESUMEN

Identification of individuals with acute HIV infection (AHI) and rapid initiation of antiretroviral therapy (ART) are priorities for HIV elimination efforts. Fourth- and fifth-generation HIV-1/HIV-2 antigen (Ag)/antibody (Ab) combination assays can quickly identify patients with AHI, but false-positive results can occur. Confirmatory nucleic acid amplification testing (NAAT) may not be rapidly available. We reviewed the data for 127 patients with positive fourth-generation ARCHITECT and fifth-generation Bio-Plex immunoassay results who had negative or indeterminate confirmatory Ab testing results, which yielded 38 patients with confirmed AHI and 89 patients with false-positive results. The receiver operating characteristic (ROC) curves showed excellent discriminatory power, with an area under the curve (AUC) for the signal-to-cutoff (S/CO) ratio of 0.970 (95% confidence interval [CI], 0.935 to 1.00) and an AUC for the Ag index (AI) of 0.968 (95% CI, 0.904 to 1.00). A threshold of 3.78 for the S/CO ratio would maximize the sensitivity (96.3%) and specificity (93.4%). The threshold for AI was 2.83 (sensitivity of 100% and specificity of 96.4%). The S/CO ratio was significantly correlated with the viral load (Spearman correlation coefficient, 0.486 [P = 0.014]), but the AI was not. The viral loads were all high, with a median of >2.8 million copies/mL. Two false-positive results with AI and S/CO ratio values markedly higher than the medians were observed, indicating that biological false-positive results can occur. Review of the S/CO ratio or AI may be used to improve the accuracy of AHI diagnosis prior to confirmatory NAAT results being available.


Asunto(s)
Infecciones por VIH , VIH-1 , Humanos , Anticuerpos Anti-VIH , Antígenos VIH , Infecciones por VIH/diagnóstico , Infecciones por VIH/tratamiento farmacológico , VIH-1/genética , VIH-2 , Inmunoensayo/métodos , Sensibilidad y Especificidad
3.
PLoS Negl Trop Dis ; 18(5): e0011335, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38805559

RESUMEN

BACKGROUND: Congenital toxoplasmosis is a treatable, preventable disease, but untreated causes death, prematurity, loss of sight, cognition and motor function, and substantial costs worldwide. OBJECTIVES: We asked whether high performance of an Immunochromatographic-test (ICT) could enable accurate, rapid diagnosis/treatment, establishing new, improved care-paradigms at point-of-care and clinical laboratory. METHODS: Data were obtained in 12 studies/analyses addressing: 1-feasibility/efficacy; 2-false-positives; 3-acceptability; 4-pink/black-line/all studies; 5-time/cost; 6-Quick-Information/Limit-of-detection; 7, 8-acute;-chronic; 9-epidemiology; 10-ADBio; 11,12-Commentary/Cases/Chronology. FINDINGS: ICT was compared with gold-standard or predicate-tests. Overall, ICT performance for 1093 blood/4967 sera was 99.2%/97.5% sensitive and 99.0%/99.7% specific. However, in clinical trial, FDA-cleared-predicate tests initially caused practical, costly problems due to false-positive-IgM results. For 58 persons, 3/43 seronegative and 2/15 chronically infected persons had false positive IgM predicate tests. This caused substantial anxiety, concerns, and required costly, delayed confirmation in reference centers. Absence of false positive ICT results contributes to solutions: Lyon and Paris France and USA Reference laboratories frequently receive sera with erroneously positive local laboratory IgM results impeding patient care. Therefore, thirty-two such sera referred to Lyon's Reference laboratory were ICT-tested. We collated these with other earlier/ongoing results: 132 of 137 USA or French persons had false-positive local laboratory IgM results identified correctly as negative by ICT. Five false positive ICT results in Tunisia and Marseille, France, emphasize need to confirm positive ICT results with Sabin-Feldman-Dye-test or western blot. Separate studies demonstrated high performance in detecting acute infections, meeting FDA, CLIA, WHO REASSURED, CEMark criteria and patient and physician satisfaction with monthly-gestational-ICT-screening. CONCLUSIONS/SIGNIFICANCE: This novel paradigm using ICT identifies likely false positives or raises suspicion that a result is truly positive, rapidly needing prompt follow up and treatment. Thus, ICT enables well-accepted gestational screening programs that facilitate rapid treatment saving lives, sight, cognition and motor function. This reduces anxiety, delays, work, and cost at point-of-care and clinical laboratories. TRIAL REGISTRATION: NCT04474132, https://clinicaltrials.gov/study/NCT04474132 ClinicalTrials.gov.


Asunto(s)
Toxoplasmosis Congénita , Femenino , Humanos , Recién Nacido , Embarazo , Anticuerpos Antiprotozoarios/sangre , Reacciones Falso Positivas , Inmunoglobulina M/sangre , Diagnóstico Prenatal/métodos , Sensibilidad y Especificidad , Toxoplasma/inmunología , Toxoplasmosis Congénita/diagnóstico , Toxoplasmosis Congénita/prevención & control
4.
J Clin Virol ; 129: 104468, 2020 08.
Artículo en Inglés | MEDLINE | ID: mdl-32485620

RESUMEN

As the Coronavirus 2019 (COVID-19) pandemic evolves, the development of immunoassays to help determine exposure and potentially predict immunity has become a pressing priority. In this report we present the performance of the EUROIMMUN enzyme-linked immunosorbent assay (ELISA) for semi-quantitative detection of IgA and IgG antibodies in serum and plasma samples using recombinant S1 domain of the SARS-CoV-2 spike protein as antigen. Specimens from patients, with and without COVID-19 infection, were tested at the University of Chicago Clinical Microbiology and Immunology Laboratory. Of 86 samples from SARS-CoV-2 PCR-negative patients, including 28 samples positive for common human coronavirus strains, 76 tested negative and 10 tested positive for IgA (88.4% agreement, 95% CI: 79.9-93.6) while 84 tested negative and 2 tested positive for IgG (97.7% agreement, 95% CI: 91.9-99.6). Of 82 samples from SARS-CoV-2 PCR-positive patients, 14 tested negative and 68 tested positive for IgA (82.9% agreement, 95% CI: 73.4-89.5) while 27 tested negative and 55 tested positive for IgG (67.1% agreement, 95% CI: 56.3-76.3). Of samples collected ≥4 days after positive PCR, 38 of 42 (90.5% agreement, 95% CI: 77.9-96.2) were positive for IgA, and 42 of 42 (100% agreement, 95% CI: 91.6-100) were positive for IgG, respectively. The EUROIMMUN Anti-SARS-CoV-2 ELISA Assay demonstrated good sensitivity for detection of IgA and excellent sensitivity for detection of IgG antibodies from samples collected ≥4 days, after COVID-19 diagnosis by PCR. This assay demonstrated good specificity for IgA and excellent specificity for IgG and demonstrated only borderline cross reaction in 2 of the 28 samples from patients with common human coronaviruses infection, types NL63 and OC43.


Asunto(s)
Anticuerpos Antivirales/sangre , Betacoronavirus/inmunología , Técnicas de Laboratorio Clínico/métodos , Infecciones por Coronavirus/diagnóstico , Ensayo de Inmunoadsorción Enzimática/métodos , Inmunoglobulina A/sangre , Inmunoglobulina G/sangre , Neumonía Viral/diagnóstico , COVID-19 , Prueba de COVID-19 , Chicago , Humanos , Pandemias , SARS-CoV-2 , Sensibilidad y Especificidad , Pruebas Serológicas/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA