Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Sensors (Basel) ; 19(16)2019 Aug 14.
Artículo en Inglés | MEDLINE | ID: mdl-31416185

RESUMEN

Pre-treatment screening of individuals for human leukocyte antigens (HLA) HLA-B*57:01 is recommended for the prevention of life-threatening hypersensitivity reactions to abacavir, a drug widely prescribed for HIV treatment. However, the implementation of screening in clinical practice is hindered by the slow turnaround time and high cost of conventional HLA genotyping methods. We have developed a biosensor platform using interdigitated electrode (IDE) functionalized with a monoclonal antibody to detect cells expressing HLA-B*57:01. This platform was evaluated using cell lines and peripheral blood mononuclear cells expressing different HLA-B alleles. The functionalized IDE sensor was able to specifically capture HLA-B*57:01 cells, resulting in a significant change in the impedance magnitude in 20 min. This IDE platform has the potential to be further developed to enable point-of-care HLA-B*57:01 screening.


Asunto(s)
Técnicas Biosensibles/métodos , Didesoxinucleósidos/efectos adversos , Hipersensibilidad a las Drogas/prevención & control , Antígenos HLA-B/análisis , Leucocitos Mononucleares/metabolismo , Alelos , Anticuerpos Inmovilizados/química , Anticuerpos Inmovilizados/inmunología , Anticuerpos Monoclonales/química , Anticuerpos Monoclonales/inmunología , Didesoxinucleósidos/uso terapéutico , Hipersensibilidad a las Drogas/etiología , Técnicas Electroquímicas , Electrodos , Infecciones por VIH/tratamiento farmacológico , Antígenos HLA-B/genética , Antígenos HLA-B/inmunología , Humanos
2.
Sensors (Basel) ; 19(11)2019 May 29.
Artículo en Inglés | MEDLINE | ID: mdl-31146340

RESUMEN

Elimination of malaria is a global health priority. Detecting an asymptomatic carrier of Plasmodium parasites to receive treatment is an important step in achieving this goal. Current available tools for detection of malaria parasites are either expensive, lacking in sensitivity for asymptomatic carriers, or low in throughput. We investigated the sensitivity of an impedimetric biosensor targeting the malaria biomarker Plasmodium lactate dehydrogenase (pLDH). Following optimization of the detection protocol, sensor performance was tested using phosphate-buffered saline (PBS), and then saliva samples spiked with pLDH at various concentrations. The presence of pLDH was determined by analyzing the sensor electrical properties before and after sample application. Through comparing percentage changes in impedance magnitude, the sensors distinguished pLDH-spiked PBS from non-spiked PBS at concentrations as low as 250 pg/mL (p = 0.0008). Percentage changes in impedance magnitude from saliva spiked with 2.5 ng/mL pLDH trended higher than those from non-spiked saliva. These results suggest that these biosensors have the potential to detect concentrations of pLDH up to two logs lower than currently available best-practice diagnostic tools. Successful optimization of this sensor platform would enable more efficient diagnosis of asymptomatic carriers, who can be targeted for treatment, contributing to the elimination of malaria.


Asunto(s)
Anticuerpos Antiprotozoarios/inmunología , Técnicas Biosensibles , Impedancia Eléctrica , L-Lactato Deshidrogenasa/análisis , Plasmodium/enzimología , Electrodos , Estudios de Factibilidad , Humanos , Plasmodium/inmunología , Saliva/enzimología
3.
Analyst ; 141(6): 1922-9, 2016 Mar 21.
Artículo en Inglés | MEDLINE | ID: mdl-26811849

RESUMEN

The Gram-positive bacterium, Staphylococcus aureus (S. aureus), is a major pathogen responsible for a variety of infectious diseases ranging from cellulitis to more serious conditions such as septic arthritis and septicaemia. Timely treatment with appropriate antibiotic therapy is essential to ensure clinical defervescence and to prevent further complications such as infective endocarditis or organ impairment due to septic shock. To date, initial antibiotic choice is empirical, using a "best guess" of likely organism and sensitivity- an approach adopted due to the lack of rapid identification methods for bacteria. Current culture based methods take up to 5 days to identify the causative bacterial pathogen and its antibiotic sensitivity. This paper provides proof of concept for a biosensor, based on interdigitated electrodes, to detect the presence of S. aureus and ascertain its sensitivity to flucloxacillin rapidly (within 2 hours) in a cost effective manner. The proposed method is label-free and uses non-faradic measurements. This is the first study to successfully employ interdigitated electrodes for the rapid detection of antibiotic resistance. The method described has important potential outcomes of faster definitive antibiotic treatment and more rapid clinical response to treatment.


Asunto(s)
Técnicas Biosensibles/instrumentación , Farmacorresistencia Microbiana , Dispositivos Laboratorio en un Chip , Staphylococcus aureus Resistente a Meticilina/aislamiento & purificación , Adhesión Bacteriana , Electrodos , Interacciones Hidrofóbicas e Hidrofílicas , Staphylococcus aureus Resistente a Meticilina/efectos de los fármacos , Factores de Tiempo
4.
Phys Chem Chem Phys ; 16(27): 13943-7, 2014 Jul 21.
Artículo en Inglés | MEDLINE | ID: mdl-24899067

RESUMEN

We analyzed the dielectric properties of molecular liquids using the external field method with reaction field approximations. The applicability of this method to determine the dielectric properties of molecules with zero (1,4-dioxane) and non-zero (water and bio-molecular aqueous solutions) permanent dipole moment was studied. The relative static dielectric constant obtained using the external field method for polar and non-polar molecular liquids, including molecules with zero permanent dipole moment, agreed well with the experimental values presented in the literature. Our results indicate that the Debye relaxation time constants estimated from the non-equilibrium simulations using the external field method were accurate for molecules whose permanent dipole moments were less than 12 D.

5.
Sci Rep ; 9(1): 17495, 2019 11 25.
Artículo en Inglés | MEDLINE | ID: mdl-31767887

RESUMEN

Malaria elimination is a global public health priority. To fulfil the demands of elimination diagnostics, we have developed an interdigitated electrode sensor platform targeting the Plasmodium falciparum Histidine Rich Protein 2 (PfHRP2) protein in saliva samples. A protocol for frequency-specific PfHRP2 detection in phosphate buffered saline was developed, yielding a sensitivity of 2.5 pg/mL based on change in impedance magnitude of the sensor. This protocol was adapted and optimized for use in saliva with a sensitivity of 25 pg/mL based on change in resistance. Further validation demonstrated detection in saliva spiked with PfHRP2 from clinical isolates in 8 of 11 samples. With a turnaround time of ~2 hours, the label-free platform based on impedance sensors has the potential for miniaturization into a point-of-care diagnostic device for malaria elimination.


Asunto(s)
Antígenos de Protozoos/análisis , Malaria Falciparum/diagnóstico , Plasmodium falciparum/metabolismo , Proteínas Protozoarias/análisis , Saliva/parasitología , Técnicas Biosensibles/instrumentación , Pruebas Diagnósticas de Rutina , Impedancia Eléctrica , Humanos , Miniaturización , Sistemas de Atención de Punto , Sensibilidad y Especificidad
6.
Biosens Bioelectron ; 111: 174-183, 2018 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-29673585

RESUMEN

Prevention of life threatening hypersensitivity reactions to carbamazepine is possible through pre-treatment screening of the associated HLA-B*15:02 risk allele. However, clinical implementation of screening is hindered by the high cost and slow turnaround of conventional HLA typing methods. We have developed an interdigitated electrode (IDE) biosensor platform utilizing loop mediated isothermal amplification (LAMP) that can rapidly detect the HLA-B*15:02 allele. DNA amplification is followed by solid-phase hybridization of LAMP amplicons to a DNA probe immobilized on the IDE sensor surface, resulting in a change in sensor impedance. The testing platform does not require DNA extraction or post-amplification staining, achieving sample-to-answer in 1 h and 20 min. The platform was tested on 27 whole blood samples (14 HLA-B*15:02 positive and 13 negative) with sensitivity of 92.9% and specificity of 84.6% when applying a cutoff of impedance change. Based on these characters the LAMP-IDE platform has potential to be further developed into point-of-care use to help overcome barriers in HLA-B*15:02 screening.


Asunto(s)
Técnicas Biosensibles/instrumentación , Hipersensibilidad a las Drogas/genética , Técnicas de Genotipaje/instrumentación , Antígenos HLA-B/genética , Alelos , Secuencia de Bases , Sondas de ADN/genética , Hipersensibilidad a las Drogas/sangre , Electricidad , Electrodos , Diseño de Equipo , Genotipo , Antígenos HLA-B/sangre , Humanos , Ácidos Nucleicos Inmovilizados/genética , Técnicas de Amplificación de Ácido Nucleico/instrumentación , Sistemas de Atención de Punto
7.
Biosensors (Basel) ; 7(2)2017 May 05.
Artículo en Inglés | MEDLINE | ID: mdl-28475117

RESUMEN

The early detection of colorectal cancer is vital for disease management and patient survival. Fecal hemoglobin detection is a widely-adopted method for screening and early diagnosis. Fecal Immunochemical Test (FIT) is favored over the older generation chemical based Fecal Occult Blood Test (FOBT) as it does not require dietary or drug restrictions, and is specific to human blood from the lower digestive tract. To date, no quantitative FIT platforms are available for use in the point-of-care setting. Here, we report proof of principle data of a novel low cost quantitative fecal immunochemical-based biosensor platform that may be further developed into a point-of-care test in low-resource settings. The label-free prototype has a lower limit of detection (LOD) of 10 µg hemoglobin per gram (Hb/g) of feces, comparable to that of conventional laboratory based quantitative FIT diagnostic systems.


Asunto(s)
Técnicas Biosensibles/métodos , Neoplasias Colorrectales/sangre , Detección Precoz del Cáncer , Hemoglobinas/aislamiento & purificación , Neoplasias Colorrectales/diagnóstico , Heces/química , Hemoglobinas/química , Humanos , Sangre Oculta
8.
Sci Rep ; 3: 1796, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-23652459

RESUMEN

Frequency dependent dielectric properties are important for understanding the structure and dynamics of biological materials. These properties can be used to study underlying biological processes such as changes in the concentration of biological materials, and the formation of chemical species. Computer simulations can be used to determine dielectric properties and atomic details inaccessible via experimental methods. In this paper, a unified theory utilizing molecular dynamics and density functional theory is presented that is able to determine the frequency dependent dielectric properties of biological materials in an aqueous solution from their molecular structure alone. The proposed method, which uses reaction field approximations, does not require a prior knowledge of the static dielectric constant of the material. The dielectric properties obtained from our method agree well with experimental values presented in the literature.


Asunto(s)
Modelos Químicos , Simulación de Dinámica Molecular , Simulación por Computador , Estructura Molecular , Agua/química
9.
Radiat Prot Dosimetry ; 141(3): 255-68, 2010 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-20554578

RESUMEN

Electricity is used substantially and sources of electric and magnetic fields are, unavoidably, everywhere. The transportation system is a source of these fields, to which a large proportion of the population is exposed. Hence, investigation of the effects of long-term exposure of the general public to low-frequency electromagnetic fields caused by the transportation system is critically important. In this study, measurements of electric and magnetic fields emitted from Australian trams, trains and hybrid cars were investigated. These measurements were carried out under different conditions, locations, and are summarised in this article. A few of the measured electric and magnetic field strengths were significantly lower than those found in prior studies. These results seem to be compatible with the evidence of the laboratory studies on the biological effects that are found in the literature, although they are far lower than international levels, such as those set up in the International Commission on Non-Ionising Radiation Protection guidelines.


Asunto(s)
Campos Electromagnéticos , Radiometría/métodos , Automóviles , Exposición a Riesgos Ambientales , Humanos , Dosis de Radiación , Monitoreo de Radiación/instrumentación , Vías Férreas , Transportes
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA