Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 43
Filtrar
Más filtros

País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Catheter Cardiovasc Interv ; 97(1): 167-174, 2021 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-32445607

RESUMEN

OBJECTIVES: The aim of the study was to evaluate mid- to late clinical and echocardiographic outcomes after transcatheter aortic valve replacement (TAVR) with Acurate neo™ (Boston Scientific, Boston, MA). BACKGROUND: TAVR is an established treatment for aortic stenosis (AS). Few data exist on mid- to long-term outcomes and durability after new-generation valves. METHODS: All consecutive patients (n = 104) who underwent Acurate neo™ implantation from 2012 to 2018 were included. Follow-up was systematically performed at 1, 6, 12, and 24 months and yearly thereafter. Outcomes were reported according to VARC-2, and structural valve deterioration (SVD) or bioprosthetic valve failure defined accordingly to new definitions. RESULTS: Mean age was 82 ± 5.4 years, 56.7% were female and the Society of Thoracic Surgeons score for mortality was 5.9 ± 4%. Patients were followed for a median of 3 years (1,092 days; IQR 1.5-4 years), and the maximum follow-up was 7 years. All-cause mortality values at 1 and 5 years were 8.5% and 40.5%, respectively. No relevant changes in mean gradient and orifice area occurred (7.9 ± 3.8 mmHg and 1.9 ± 0.3 cm2 at 1 year; 6.6 ± 2.1 mmHg and 1.8 ± 0.3 cm2 at 5 years), and there was a significant rate of paravalvular leaks resolution at 1, 2, and 3 years (p = .004; p < .001; p < .001, respectively). None of the patients had leaflet thrombosis or endocarditis. One patient developed SVD at 84 months. CONCLUSIONS: Acurate neo™ was associated with sustained echocardiographic results. Reassuring mid- to long-term outcomes was observed in this cohort of elderly patients with severe AS.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Ecocardiografía , Femenino , Humanos , Diseño de Prótesis , Factores de Riesgo , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
2.
Eur Heart J ; 38(13): 961-969, 2017 04 01.
Artículo en Inglés | MEDLINE | ID: mdl-27190095

RESUMEN

Aims: Although a true clinical challenge, high bleeding risk patients with an acute coronary syndrome (ACS) undergoing percutaneous coronary intervention (PCI) have never been specifically studied. Leaders Free ACS, a pre-specified Leaders Free sub-study, determined efficacy, and safety of a combination of 1-month dual anti-platelet therapy (DAPT) with implantation of either a polymer-free Biolimus-A9-coated stent (BA9-DCS) or a bare-metal stent (BMS) in these patients. Methods and results: Leaders Free included 2466 patients undergoing PCI who had at least 1 of 13 pre-defined factors for an increased bleeding risk. Of these, 659 ACS patients were included in this analysis (BA9-DCS 330, BMS 329). At 12-month follow-up, treatment with the BA9-DCS was more effective (clinically driven target-lesion revascularization 3.9 vs. 9.0%, P = 0.009) and safer (cumulative incidence of cardiac death, myocardial infarction, or definite or probable stent thrombosis 9.3 vs. 18.5%, P = 0.001), driven by significantly lower rates of cardiac mortality (3.4 vs. 6.9%, P = 0.049) and myocardial infarction (6.9 vs. 13.8%, P = 0.005). Conclusion: We believe that the results of this sub-analysis from the Leaders Free trial are likely to significantly impact clinical practice for high bleeding risk patients presenting with an ACS: the use of a BMS can, in our view, no longer be recommended, and, given the paucity of available data for second-generation DES with shortened DAPT in these patients, the BA9-DCS should currently be considered as the device with the strongest evidence to support its use for this indication.


Asunto(s)
Stents Liberadores de Fármacos , Hemorragia/etiología , Inmunosupresores/administración & dosificación , Infarto del Miocardio sin Elevación del ST/cirugía , Infarto del Miocardio con Elevación del ST/cirugía , Sirolimus/análogos & derivados , Síndrome Coronario Agudo/cirugía , Anciano , Método Doble Ciego , Quimioterapia Combinada , Femenino , Oclusión de Injerto Vascular/etiología , Humanos , Masculino , Infarto del Miocardio sin Elevación del ST/tratamiento farmacológico , Intervención Coronaria Percutánea/métodos , Inhibidores de Agregación Plaquetaria/administración & dosificación , Factores de Riesgo , Infarto del Miocardio con Elevación del ST/tratamiento farmacológico , Sirolimus/administración & dosificación , Resultado del Tratamiento
3.
Catheter Cardiovasc Interv ; 90(1): 139-146, 2017 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-28029207

RESUMEN

OBJECTIVE: We sought to compare the new transcatheter aortic valve replacement (TAVR) device ACURATE neo (ACT) with the already established CoreValve (MCV) and SAPIEN XT (SXT) for the treatment of severe aortic stenosis (AS). BACKGROUND: Very few data on TAVR devices are available beyond MCV and SAPIEN and there is no previous study comparing ACT with MCV and SXT. METHODS: We prospectively evaluated consecutive patients who underwent transfemoral TAVR for the treatment of severe AS. Clinical outcomes were reported following Valve Academic Research Consortium 2 (VARC-2) criteria. RESULTS: A total of 162 patients (ACT n = 49, MCV n = 56, SXT n = 57), were included. MCV group had higher valve embolization/migration rates (ACT none; MCV 9%; SXT 2%; P = 0.034) causing lower device success rates (ACT 98%; MCV 86%; SXT 95%; P = 0.043). At 30 days, there was no significant difference in all-cause mortality (P = 0.22), cardiovascular mortality (P = 0.20), periprocedural myocardial infarction (P = 0.40), stroke (P = 0.64), major vascular complications (P = 0.48), life-threatening bleeding (P = 0.29), acute kidney injury stage 2/3 (P = 0.69), or VARC-2 composite early safety endpoints (P = 0.21). MCV group had higher rates of new permanent pacemaker implantation (ACT 6%; MCV 25%; SXT 11%; P = 0.013). Follow-up echocardiography showed no significant difference in aortic valve mean pressure gradient (P = 0.73) or moderate/severe aortic regurgitation (P = 0.19) between groups. CONCLUSIONS: In a "real world" registry, ACT compared favorably against the well-studied SXT and MCV devices in both safety and efficacy. MCV implantation was associated with lower device success rates and higher rates of new permanent pacemaker implantation. © 2016 Wiley Periodicals, Inc.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Prótesis Valvulares Cardíacas , Grupo de Atención al Paciente , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/fisiopatología , Brasil , Femenino , Hemodinámica , Humanos , Masculino , Complicaciones Posoperatorias/etiología , Estudios Prospectivos , Diseño de Prótesis , Recuperación de la Función , Sistema de Registros , Índice de Severidad de la Enfermedad , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Resultado del Tratamiento
4.
Arq Bras Cardiol ; 121(7): e20230622, 2024 Jun.
Artículo en Portugués, Inglés | MEDLINE | ID: mdl-39082574

RESUMEN

BACKGROUND: Robust data on the learning curve (LC) of transcatheter aortic valve replacement (TAVR) are lacking in developing countries. OBJECTIVE: To assess TAVR's LC in Brazil over time. METHODS: We analyzed data from the Brazilian TAVR registry from 2008 to 2023. Patients from each center were numbered chronologically in case sequence numbers (CSNs). LC was performed using restricted cubic splines adjusted for EuroSCORE-II and the use of new-generation prostheses. Also, in-hospital outcomes were compared between groups defined according to the level of experience based on the CSN: 1st to 40th (initial-experience), 41st to 80th (early-experience), 81st to 120th (intermediate-experience), and over 121st (high-experience). Additional analysis was performed grouping hospitals according to the number of cases treated before 2014 (>40 and ≤40 procedures). The level of significance adopted was <0.05. RESULTS: A total of 3,194 patients from 25 centers were included. Mean age and EuroSCORE II were 80.7±8.1 years and 7±7.1, respectively. LC analysis demonstrated a drop in adjusted in-hospital mortality after treating 40 patients. A leveling off of the curve was observed after case #118. In-hospital mortality across the groups was 8.6%, 7.7%, 5.9%, and 3.7% for initial-, early-, intermediate-, and high-experience, respectively (p<0.001). High experience independently predicted lower mortality (OR 0.57, p=0.013 vs. initial experience). Low-volume centers before 2014 showed no significant decrease in the likelihood of death with gained experience, whereas high-volume centers had a continuous improvement after case #10. CONCLUSION: A TAVR LC phenomenon was observed for in-hospital mortality in Brazil. This effect was more pronounced in centers that treated their first 40 cases before 2014 than those that reached this milestone after 2014.


Asunto(s)
Mortalidad Hospitalaria , Curva de Aprendizaje , Sistema de Registros , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Reemplazo de la Válvula Aórtica Transcatéter/estadística & datos numéricos , Brasil/epidemiología , Femenino , Masculino , Anciano de 80 o más Años , Anciano , Factores de Tiempo , Factores de Riesgo , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/mortalidad , Resultado del Tratamiento , Medición de Riesgo
5.
ASAIO J ; 69(3): e121-e124, 2023 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-35696694

RESUMEN

Reverse cardiac remodeling may occur in some left ventricular assist device (LVAD) recipients. Although considered the standard therapy, surgical device explantation with repeat sternotomy might be undesirable or very high risk. On the other hand, there are few data reporting minimally invasive percutaneous LVAD deactivation. We describe a case of a man with LVAD malfunction due to driveline fracture and left ventricular (LV) function recovery who had a Heart Mate II deactivated with a percutaneous technique using a left atrial appendage occluder (LAAO) positioned inside the outflow cannula. To the best of our knowledge, this the first report of LVAD deactivation with the fully recapturable LAAO device. We propose that the use of a LAA occluder to obstruct HM II outflow cannula is feasible and safe.


Asunto(s)
Apéndice Atrial , Corazón Auxiliar , Masculino , Humanos , Corazón Auxiliar/efectos adversos , Cánula , Función Ventricular Izquierda/fisiología , Esternotomía
6.
Arq Bras Cardiol ; 120(11): e20220496, 2023 Nov.
Artículo en Portugués, Inglés | MEDLINE | ID: mdl-38126512

RESUMEN

BACKGROUND: Central Illustration : Percutaneous Strategies in Structural Heart Diseases: Focus on Chronic Heart Failure Transcatheter devices for monitoring and treating advanced chronic heart failure patients. PA: pulmonary artery; LA: left atrium; AFR: atrial flow regulator; TASS: Transcatheter Atrial Shunt System; VNS: vagus nerve stimulation; BAT: baroreceptor activation therapy; RDN: renal sympathetic denervation; F: approval by the American regulatory agency (FDA); E: approval by the European regulatory agency (CE Mark). BACKGROUND: Innovations in devices during the last decade contributed to enhanced diagnosis and treatment of patients with cardiac insufficiency. These tools progressively adapted to minimally invasive strategies with rapid, widespread use. The present article focuses on actual and future directions of device-related diagnosis and treatment of chronic heart failure.


Asunto(s)
Insuficiencia Cardíaca , Humanos , Insuficiencia Cardíaca/terapia , Simpatectomía , Atrios Cardíacos , Riñón
7.
J Invasive Cardiol ; 34(3): E251-E252, 2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-35235532

RESUMEN

The image in this vignette helps to illustrate a rare, albeit reported, complication of endomyocardial biopsy. The case was discussed by the heart team. Fistula occlusion with microcoils was considered; however, the patient was asymptomatic and presented no reduction of left ventricular ejection fraction, and the documented ischemia was minor. Therefore, the patient received conservative treatment.


Asunto(s)
Enfermedad Coronaria , Fístula , Trasplante de Corazón , Arterias , Biopsia/efectos adversos , Fístula/complicaciones , Fístula/etiología , Trasplante de Corazón/efectos adversos , Ventrículos Cardíacos/diagnóstico por imagen , Humanos , Volumen Sistólico , Función Ventricular Izquierda
8.
Arq Bras Cardiol ; 118(5): 861-872, 2022 05.
Artículo en Inglés, Portugués | MEDLINE | ID: mdl-35137775

RESUMEN

BACKGROUND: Hypertrophic cardiomyopathy (HCM) can cause obstruction in the left ventricular outflow tract (LVOT), and be responsible for the onset of limiting symptoms, such as tiredness. When such symptoms are refractory to pharmacological treatment, interventionist alternative therapies can be useful, such as septal ablation through the infusion of alcohol in the coronary artery or through myectomy. Recently, the use of a radiofrequency (RF) catheter for endocardial septal ablation guided by electroanatomic mapping has proven to be efficient, despite the high incidence of complete atrioventricular block. An alternative would be the application of RF at the beginning point of the septal gradient guided by the transesophageal echocardiography (TEE). The echocardiography is an imaging method with high accuracy to determine septal anatomy. OBJECTIVE: To assess the long term effect of septal ablation for the relief of ventricular-arterial gradient, using TEE to help place the catheter in the area of larger septal obstruction. Besides, to assess the effects of ablation on the functional class and echocardiographic parameters. METHODS: Twelve asymptomatic patients, with LVOT obstruction, refractory to pharmacological therapy, underwent endocardial septal ablation with 8mm-tip catheters, whose placement was oriented in the region of larger obstruction, assisted by the TEE. Temperature-controlled and staggered RF applications were performed. After each application, the gradient was reassessed and a new application was performed according to the clinical criterion. The effects of RF applications were assessed both for the gradient at rest and for that provoked by the Valsalva maneuver, and considering the gradient. The differences were significant when p-value was lower than or equal to 0.05. RESULTS: It was possible to observe that the mean reduction of the maximum gradients was from 96.8±34.7 mmHg to 62.7±25.4 mmHg three months after the procedure (p=0.0036). After one year, the mean of maximum gradient was 36.1±23.8 mmHg (p=0.0001). The procedure was well tolerated, without records of complete atrioventricular block nor severe complications. CONCLUSION: The TEE-guided septal ablation was efficient and safe, and the results were maintained during the clinical follow-up period. It is a reasonable option for the interventionist treatment of LVOT obstruction in HCM.


FUNDAMENTOS: A cardiomiopatia hipertrófica (CMH) pode causar obstrução da via de saída do ventrículo esquerdo (VSVE) e ser responsável pelo surgimento de sintomas limitantes, como cansaço físico. Quando tais sintomas são refratários ao tratamento farmacológico, os tratamentos alternativos intervencionistas podem ser úteis, como a ablação septal por meio da infusão de álcool na artéria coronária ou por meio da miectomia cirúrgica. Recentemente, o uso de cateter de radiofrequência (RF) para ablação do septo endocárdico guiado por mapeamento eletroanatômico mostrou-se eficaz apesar da elevada incidência de bloqueio atrioventricular total. Uma alternativa seria a aplicação de radiofrequência no ponto de início do gradiente septal guiada pelo ecocardiograma transesofágico (ETE). O ecocardiograma é um método de imagem com elevada acurácia para determinação da anatomia septal. OBJETIVO: Avaliar o efeito em longo prazo da ablação septal para alívio do gradiente ventrículo-arterial, utilizando o ETE para auxiliar no posicionamento do cateter na área de maior obstrução septal. Avaliar também os efeitos da ablação na classe funcional e parâmetros ecocardiográficos. MÉTODOS: Doze pacientes sintomáticos com obstrução da VSVE, refratários à terapia farmacológica, foram submetidos à ablação endocárdica septal com cateteres com ponta de 8 mm, cujo posicionamento foi orientado na região de maior obstrução com auxílio do ETE. Foram realizadas aplicações de radiofrequência (RF) termocontrolada e escalonadas sobre a área alvo. Após cada aplicação, o gradiente era reavaliado e nova aplicação era realizada de acordo com critério clínico. Foram avaliados os efeitos das aplicações de RF tanto para o gradiente em repouso como para o provocado por meio da manobra de Valsalva, e considerado o gradiente. As diferenças foram significativas quando o valor de p foi menor ou igual a 0,05. RESULTADOS: Observou-se que a redução da média dos gradientes máximos obtidos foi de 96,8±34,7 mmHg para 62,7±25,4 mmHg ao final de três meses do procedimento (p=0,0036). Após um ano, a média dos gradientes máximos obtidos foi de 36,1±23,8 mmHg (p=0,0001). O procedimento foi bem tolerado e não houve registro de bloqueio atrioventricular total e nem complicações graves. CONCLUSÃO: A ablação septal guiada pelo ETE foi eficaz e segura, com resultados mantidos durante o período de seguimento clínico. É uma opção razoável para o tratamento intervencionista da obstrução da VSVE em CMH.


Asunto(s)
Bloqueo Atrioventricular , Cardiomiopatía Hipertrófica , Ablación por Catéter , Bloqueo Atrioventricular/diagnóstico por imagen , Bloqueo Atrioventricular/terapia , Cardiomiopatía Hipertrófica/diagnóstico por imagen , Cardiomiopatía Hipertrófica/cirugía , Ablación por Catéter/métodos , Catéteres , Ecocardiografía/métodos , Humanos , Resultado del Tratamiento
9.
Arq Bras Cardiol ; 118(6): 1085-1096, 2022.
Artículo en Inglés, Portugués | MEDLINE | ID: mdl-35703645

RESUMEN

BACKGROUND: Transcatheter aortic valve replacement (TAVR) is a worldwide adopted procedure with rapidly evolving practices. Regional and temporal variations are expected to be found. OBJECTIVE: To compare TAVR practice in Latin America with that around the world and to assess its changes in Latin America from 2015 to 2020. METHODS: A survey was applied to global TAVR centers between March and September 2015, and again to Latin-American centers between July 2019 and January 2020. The survey consisted of questions addressing: i) center's general information; ii) pre-TAVR evaluation; iii) procedural techniques; iv) post-TAVR management; v) follow-up. Answers from the 2015 survey of Latin-American centers (LATAM15) were compared with those of other centers around the world (WORLD15) and with the 2020 updated Latin-American survey (LATAM20). A 5% level of significance was adopted for statistical analysis. RESULTS: 250 centers participated in the 2015 survey (LATAM15=29; WORLD15=221) and 46 in the LATAM20. Combined centers experience accounted for 73 707 procedures, with WORLD15 centers performing, on average, 6- and 3-times more procedures than LATAM15 and LATAM20 centers, respectively. LATAM centers performed less minimalistic TAVR than WORLD15 centers, but there was a significant increase in less invasive procedures after 5 years in Latin-American centers. For postprocedural care, a lower period of telemetry and maintenance of temporary pacing wire, along with less utilization of dual antiplatelet therapy was observed in LATAM20 centers. CONCLUSION: Despite still having a much lower number of procedures, many aspects of TAVR practice in Latin-American centers have evolved in recent years, followingthe trend observed in developed country centers.


FUNDAMENTO: Implante transcateter de valva aórtica (TAVI) é um procedimento adotado em todo o mundo e suas práticas evoluem rapidamente. Variações regionais e temporais são esperadas. OBJETIVO: Comparar a prática de TAVI na América Latina com aquela no resto do mundo e avaliar suas mudanças na América Latina de 2015 a 2020. MÉTODO: A pesquisa foi realizada em centros de TAVI em todo o mundo entre março e setembro de 2015, e novamente nos centros latino-americanos entre julho de 2019 e janeiro de 2020. As seguintes questões foram abordadas: i) informação geral sobre os centros; ii) avaliação pré-TAVI; iii) técnicas do procedimento; iv) conduta pós-TAVI; v) seguimento. As respostas da pesquisa dos centros latino-americanos em 2015 (LATAM15) foram comparadas àquelas dos centros no resto do mundo (WORLD15) e ainda àquelas da pesquisa dos centros latino-americanos de 2020 (LATAM20). Adotou-se o nível de significância de 5% na análise estatística. RESULTADOS: 250 centros participaram da pesquisa em 2015 (LATAM15=29; WORLD15=221) e 46 na avaliação LATAM20. No total, foram 73.707 procedimentos, sendo que os centros WORLD15 realizaram, em média, 6 e 3 vezes mais procedimentos do que os centros LATAM15 e LATAM20, respectivamente. Os centros latino-americanos realizaram menor número de TAVI minimalista do que os do restante do mundo, mas aumentaram significativamente os procedimentos menos invasivos após 5 anos. Quanto à assistência pós-procedimento, observaram-se menor tempo de telemetria e de manutenção do marca-passo temporário, além de menor uso de terapia dupla antiplaquetária nos centros LATAM20. CONCLUSÃO: A despeito do volume de procedimentos ainda significativamente menor, muitos aspectos da prática de TAVI nos centros latino-americanos evoluíram recentemente, acompanhando a tendência dos centros dos países desenvolvidos.


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Humanos , América Latina , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Resultado del Tratamiento
10.
Cardiorenal Med ; 11(4): 166-173, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34261063

RESUMEN

BACKGROUND: Acute kidney injury (AKI) has shown to adversely affect outcomes in patients undergoing transcutaneous aortic valve replacement (TAVR), and its correct risk estimation may interfere in procedural planning and strategies. The aim of the study was to test and compare 6 scores in predicting AKI after TAVR. METHODS: We tested 6 scores (the contrast material limit score, volume-to-creatinine clearance ratio, ACEF, CR4EATME3AD3, Mehran model A, and Mehran model B) in a total of 559 consecutive patients included in the Brazilian TAVR registry. RESULTS: All scores had a poor accuracy and calibration to predict the occurrence of AKI grade 1 or 2. All scores improved the accuracy of AKI risk prediction when stratified for AKI grade 2/3 and AKI grade 3 for all scores. The CR4EATME3AD3 was the best predictor of AKI stage 2/3 (AUC: 0.62; OR: 1.12; 95% CI 1.01-1.26; p = 0.04) and AKI stage 3 (AUC: 0.64; OR: 1.16; 95% CI 1.02-1.32; p = 0.02). Mehran models A and B were both good models for AKI stage 3 (AUC: 0.63; OR: 1.10; 95% CI 1.01-1.22; p = 0.05; and AUC: 0.62; OR: 1.10; 95% CI 1.00-1.21; p = 0.05, respectively). CONCLUSIONS: None of the current models demonstrated validity in detecting AKI when its lower grades were evaluated. CR4EATME3AD3 was the best score in predicting moderate to severe AKI after TAVR. These findings suggest that contrast-induced AKI may not be the only factor related to kidney injury after TAVR.


Asunto(s)
Lesión Renal Aguda , Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Lesión Renal Aguda/inducido químicamente , Lesión Renal Aguda/diagnóstico , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Humanos , Factores de Riesgo
11.
Arq Bras Cardiol ; 116(6): 1059-1069, 2021 06.
Artículo en Inglés, Portugués | MEDLINE | ID: mdl-34133587

RESUMEN

BACKGROUND: Mitral regurgitation (MR) is prevalent in patients undergoing transcatheter aortic valve implantation (TAVI). There are some controversies about the prognostic impact of MR in survival of TAVI patients. OBJECTIVE: To examine the relationship between TAVI and MR in a patient population from the Brazilian TAVI Registry. METHODS: Seven hundred and ninety-five patients from the Brazilian TAVI Registry were divided at baseline, discharge, and follow-up according to their MR grade as follows: absent/mild (AMMR) or moderate/severe (MSMR). They were subsequently regrouped according to their immediate and late changes in MR severity after TAVI as follows: no change, improved, or worsened MR. Predictors and prognostic impact on baseline as well as changes in MR severity were analyzed. Statistical significance was set at p < 0.05. RESULTS: Baseline MSMR was present in 19.3% of patients and was a predictor of increased late mortality. Immediately after TAVI, 47.4 % of cases improved to AMMR, predicted by a higher Society of Thoracic Surgeons score and a higher grade of baseline aortic regurgitation. Upon follow-up, 9.2% of cases of AMMR worsened to MSMR, whereas 36.8% of cases of MSMR improved to AMMR. Lower baseline left ventricular ejection fraction (LVEF) and improvement in LVEF at follow-up were predictors of MR improvement. Progressive worsening of MR upon follow-up was an independent predictor of higher late mortality after TAVI (p = 0.005). CONCLUSIONS: Baseline MSMR predicts late mortality after TAVI. Lower LVEF and improved LVEF at follow-up predict MR improvement after TAVI. Progressive worsening of MR severity at follow-up is an independent predictor of late mortality, which is a rare finding in the literature.


FUNDAMENTO: A regurgitação mitral (RM) é prevalente em pacientes submetidos a implante transcateter de válvula aórtica (TAVI). Há algumas controvérsias sobre o impacto prognóstico da RM na sobrevida de pacientes submetidos a TAVI. OBJETIVO: Examinar a relação entre TAVI e RM em uma população de pacientes do Registro Brasileiro de TAVI. MÉTODOS: Setecentos e noventa e cinco pacientes do Registro Brasileiro de TAVI foram divididos na linha de base, alta e acompanhamento de acordo com o grau da RM da maneira seguinte: ausente/leve (RMAL) ou moderado/grave (RMMG). Eles foram subsequentemente reagrupados de acordo com as mudanças imediatas e tardias na gravidade da RM após TAVI da maneira seguinte: RM sem mudança, melhora ou piora. Foram analisados os preditores e o impacto prognóstico na linha de base, bem como as mudanças na gravidade da RM. A significância estatística foi estabelecida em p < 0,05. RESULTADOS: RMMG basal estava presente em 19,3% dos pacientes e foi um preditor de aumento da mortalidade tardia. Imediatamente após o TAVI, 47,4% dos casos melhoraram para RMAL, previsto por uma pontuação mais alta da Society of Thoracic Surgeons e um grau mais alto de regurgitação aórtica basal. No acompanhamento, 9,2% dos casos de RMAL pioraram para RMMG, enquanto 36,8% dos casos de RMMG melhoraram para RMAL. Fração de ejeção do ventrículo esquerdo (FEVE) mais baixa na linha de base e melhora na FEVE durante o acompanhamento foram preditores de melhora da RM. Piora progressiva da RM no acompanhamento foi um preditor independente de maior mortalidade tardia após TAVI (p = 0,005). CONCLUSÕES: A RMMG na linha de base é um preditor de mortalidade tardia após TAVI. FEVE mais baixa e melhora na FEVE durante o acompanhamento são preditores de melhora da RM após TAVI. A pior progressiva da gravidade da RM durante o acompanhamento é um preditor independente de mortalidade tardia; isto é um achado raro na literatura.


Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Brasil , Estudios de Seguimiento , Humanos , Insuficiencia de la Válvula Mitral/cirugía , Índice de Severidad de la Enfermedad , Volumen Sistólico , Resultado del Tratamiento , Función Ventricular Izquierda
12.
Rev Port Cardiol (Engl Ed) ; 40(2): 71-76, 2021 Feb.
Artículo en Inglés, Portugués | MEDLINE | ID: mdl-33402278

RESUMEN

INTRODUCTION AND OBJECTIVES: The Stents Coated With the Biodegradable Polymer on Their Abluminal Faces and Elution of Sirolimus Versus Biolimus Elution for the Treatment of de Novo Coronary Lesions - DESTINY Trial is a non-inferiority randomized study that compared the Inspiron™ sirolimus-eluting stent (SES) with the control Biomatrix™ Flex biolimus-eluting stent (BES). Previous reports in the first year showed similar outcomes for both stents, in clinical, angiographic, optical coherence tomography, and intravascular ultrasound assessments. The present analysis aims to compare the clinical performance of these two biodegradable polymer drug-eluting stents five years after the index procedure. METHODS: A total of 170 patients (194 lesions) were randomized in a 2:1 ratio for treatment with SES or BES, respectively. The primary endpoint for the present study was the five-year rate of combined major adverse cardiac events, defined as cardiac death, myocardial infarction, or target lesion revascularization. RESULTS: At five years, the primary endpoint occurred in 12.5% and 17.9% of the SES and BES groups, respectively (p=0.4). There was no definite or probable stent thrombosis among patients treated with the novel SES stent during the five years of follow-up, and no stent thrombosis after the first year in the BES group. CONCLUSIONS: The novel Inspiron™ stent had similar good clinical performance in long-term follow-up when compared head-to-head with the control latest-generation Biomatrix™ Flex biolimus-eluting stent.


Asunto(s)
Enfermedad de la Arteria Coronaria , Stents Liberadores de Fármacos , Implantes Absorbibles , Enfermedad de la Arteria Coronaria/cirugía , Humanos , Polímeros , Diseño de Prótesis , Resultado del Tratamiento
13.
PLoS One ; 16(5): e0251066, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33984005

RESUMEN

BACKGROUND: Chronic kidney disease is commonly found in patients with aortic stenosis (AS) undergoing transcatheter aortic valve replacement (TAVR) and has marked impact in their prognosis. It has been shown however that TAVR may improve renal function by alleviating the hemodynamic barrier imposed by AS. Nevertheless, the predictors of and clinical consequences of renal function improvement are not well established. Our aim was to assess the predictors of improvement of renal function after TAVR. METHODS: The present work is an analysis of the Brazilian Registry of TAVR, a national non-randomized prospective study with 22 Brazilian centers. Patients with baseline renal dysfunction (estimated glomerular filtration rate [eGFR] < 60mL/min/1.73m2) were stratified according to renal function after TAVR: increase >10% in eGFR were classified as TAVR induced renal function improvement (TIRFI); decrease > 10% in eGFR were classified as acute kidney injury (AKI) and stable renal function (neither criteria). RESULTS: A total of 819 consecutive patients with symptomatic severe AS were included. Of these, baseline renal dysfunction (estimated glomerular filtration rate [eGFR] < 60mL/min/1.73m2) was present in 577 (70%) patients. Considering variance in renal function between baseline and at discharge after TAVR procedure, TIRFI was seen in 197 (34.1%) patients, AKI in 203 (35.2%), and stable renal function in 177 (30.7%). The independent predictors of TIRFI were: absence of coronary artery disease (OR: 0.69; 95% CI 0.48-0.98; P = 0.039) and lower baseline eGFR (OR: 0.98; 95% CI 0.97-1.00; P = 0.039). There was no significant difference in 30-day and 1-year all-cause mortality between patients with stable renal function or TIRFI. Nonetheless, individuals that had AKI after TAVR presented higher mortality compared with TIRFI and stable renal function groups (29.3% vs. 15.4% vs. 9.5%, respectively; p < 0.001). CONCLUSIONS: TIRFI was frequently found among baseline impaired renal function individuals but was not associated with improved 1-year outcomes.


Asunto(s)
Riñón/fisiología , Insuficiencia Renal Crónica/fisiopatología , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Anciano , Anciano de 80 o más Años , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Femenino , Tasa de Filtración Glomerular/fisiología , Implantación de Prótesis de Válvulas Cardíacas/métodos , Hemodinámica/fisiología , Humanos , Pruebas de Función Renal/métodos , Modelos Logísticos , Masculino , Oportunidad Relativa , Pronóstico , Estudios Prospectivos , Insuficiencia Renal Crónica/complicaciones , Insuficiencia Renal Crónica/cirugía , Medición de Riesgo , Factores de Riesgo , Índice de Severidad de la Enfermedad , Resultado del Tratamiento
14.
J Invasive Cardiol ; 32(4): 147-152, 2020 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-32160152

RESUMEN

OBJECTIVES: The aim of this study was to compare two hemostatic techniques, minimum pressure technique and patent hemostasis, on radial artery occlusion (RAO) after transradial catheterization. BACKGROUND: RAO is an infrequent complication of transradial procedures. One of the strategies used to reduce this complication is the patent hemostasis technique. Use of minimum pressure in hemostatic wristband, without monitoring patency, might have the same efficacy for preventing RAO. METHODS: This is a multicenter study encompassing patients submitted to transradial catheterization. After pneumatic wristband application, the band was deflated to the lowest allowable volume while preserving hemostasis. Radial artery patency was subsequently evaluated. The group with no return of plethysmographic curve was labeled "minimum pressure," and the group in which the signal returned was labeled "patent hemostasis." RAO was verified by Doppler evaluation within the first 24 hours of the procedure. RESULTS: A total of 1082 patients were enrolled, with mean age of 61.4 ± 10.4 years. The majority (61.0%) were male and 34.5% had diabetes. Patent hemostasis was achieved in only 213 cases (20%). Early RAO occurred in 16 patients (1.8%) in the minimum pressure group and in 4 patients (1.9%) in the patent hemostasis group (P=.97). No major bleeding was observed among the entire cohort. EASY scale for hematoma grade was similar between the cohorts (EASY grades 1-3: 7.0% in the minimum pressure group vs 7.5% in the patent hemostasis group; P=.96). CONCLUSION: Checking radial patency during hemostatic compression may not be necessary after the procedure when adopting a mild and short hemostatic compression.


Asunto(s)
Arteriopatías Oclusivas , Cateterismo Periférico , Técnicas Hemostáticas , Grado de Desobstrucción Vascular , Anciano , Arteriopatías Oclusivas/diagnóstico , Arteriopatías Oclusivas/etiología , Arteriopatías Oclusivas/prevención & control , Cateterismo Cardíaco/efectos adversos , Femenino , Hemostasis , Humanos , Masculino , Persona de Mediana Edad , Punciones/efectos adversos , Arteria Radial
15.
Arq Bras Cardiol ; 115(1): 111-126, 2020 07.
Artículo en Inglés, Portugués | MEDLINE | ID: mdl-32813825

RESUMEN

The coronavirus disease 2019 (COVID-19) pandemic is a huge challenge to the health system because of the exponential increase in the number of individuals affected. The rational use of resources and correct and judicious indication for imaging exams and interventional procedures are necessary, prioritizing patient, healthcare personnel, and environmental safety. This review was aimed at guiding health professionals in safely and effectively performing imaging exams and interventional procedures.


Asunto(s)
Betacoronavirus , Enfermedades Cardiovasculares/cirugía , Procedimientos Quirúrgicos Cardiovasculares/estadística & datos numéricos , Infecciones por Coronavirus/complicaciones , Neumonía Viral/complicaciones , Guías de Práctica Clínica como Asunto , COVID-19 , Enfermedades Cardiovasculares/complicaciones , Enfermedades Cardiovasculares/diagnóstico por imagen , Enfermedades Transmisibles Emergentes/epidemiología , Infecciones por Coronavirus/epidemiología , Ecocardiografía , Humanos , Pandemias , Neumonía Viral/epidemiología , SARS-CoV-2
16.
EuroIntervention ; 16(12): e974-e981, 2020 Dec 18.
Artículo en Inglés | MEDLINE | ID: mdl-32894231

RESUMEN

AIMS: We aimed to assess the safety and efficacy of the DynamX Novolimus-Eluting Coronary Bioadaptor System, a novel device that initially acts as a second-generation drug-eluting stent, but after six months frees the vessel through uncaging elements. METHODS AND RESULTS: This multicentre study enrolled 50 patients with single de novo lesions. In-device acute lumen gain was 1.61±0.34 mm, and device and procedure success was 100%. Up to 12 months, two target lesion failures occurred: both were cardiac deaths (day 255 and day 267 post procedure). No definite or probable device thrombosis was observed. Mean late lumen loss was 0.12±0.18 mm in-device and 0.11±0.16 mm in-segment. Per intravascular ultrasound, the mean device area and mean vessel area increased significantly by 5% and 3%, respectively, while the mean lumen area was maintained. Stationary optical coherence tomography in seven patients demonstrated restoration of cyclic pulsatility, with an approximate lumen area variance of 11% between systole and diastole. CONCLUSIONS: The DynamX bioadaptor showed drug-eluting stent-like acute performance and safety and efficacy up to one year. Positive remodelling with an increase of vessel and device area while maintaining the mean lumen area was demonstrated. Long-term follow-up and randomised trials are required to assess the benefit of this device on events beyond one year.


Asunto(s)
Enfermedad de la Arteria Coronaria , Stents Liberadores de Fármacos , Intervención Coronaria Percutánea , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/cirugía , Humanos , Intervención Coronaria Percutánea/efectos adversos , Sirolimus , Tomografía de Coherencia Óptica , Resultado del Tratamiento
17.
EuroIntervention ; 14(18): e1836-e1842, 2019 Apr 05.
Artículo en Inglés | MEDLINE | ID: mdl-29957593

RESUMEN

AIMS: The MASTER study was designed to compare the performance of a new biodegradable polymer sirolimus-eluting stent (BP-SES) with a bare metal stent (BMS) in patients with ST-segment elevation myocardial infarction (STEMI). METHODS AND RESULTS: The study was a prospective, randomised (3:1), controlled, single-blind multicentre trial that enrolled 500 STEMI patients within 24 hours of symptom onset during 2013-2015. Three hundred and seventy-five patients were treated with BP-SES and 125 with BMS. One hundred and four (104) randomised patients underwent angiographic follow-up at six months. The primary clinical endpoint was target vessel failure (TVF), defined as cardiac death, MI not clearly attributable to a non-target vessel, or clinically driven target vessel revascularisation (TVR) at 12 months. The primary angiographic endpoint was in-stent late lumen loss (LLL) at six months in the angiographic cohort. The major secondary endpoint for safety was a composite of all-cause death, recurrent MI, unplanned infarct-related artery revascularisation, stroke, definite stent thrombosis (ST) or major bleeding at one month. At 12 months, TVF had occurred in 6.1% of BP-SES and 14.4% of BMS patients (pnon-inferiority=0.0004), mainly driven by a higher rate of repeat revascularisation in BMS patients. The safety endpoint occurred in 3.5% of BP-SES and 7.2% of BMS patients (p=0.127). In-stent LLL demonstrated the superiority (p=0.0125) of BP-SES (0.09±0.43 mm) over BMS (0.79±0.67 mm). CONCLUSIONS: The study showed clinical non-inferiority and angiographic superiority of BP-SES versus a comparator BMS, suggesting that this novel DES may be a potential treatment option in STEMI.


Asunto(s)
Stents Liberadores de Fármacos , Infarto del Miocardio con Elevación del ST , Humanos , Polímeros , Estudios Prospectivos , Infarto del Miocardio con Elevación del ST/cirugía , Método Simple Ciego , Sirolimus , Resultado del Tratamiento
18.
Arq. bras. cardiol ; Arq. bras. cardiol;121(7): e20230622, jun.2024. tab, graf
Artículo en Portugués | LILACS-Express | LILACS, SESSP-IDPCPROD, SES-SP | ID: biblio-1563934

RESUMEN

Resumo Fundamento Dados robustos sobre a curva de aprendizagem (LC) da substituição da válvula aórtica transcateter (TAVR) são escassos nos países em desenvolvimento. Objetivo Avaliar a LC da TAVR no Brasil ao longo do tempo. Métodos Analisamos dados do registro brasileiro de TAVR de 2008 a 2023. Pacientes de cada centro foram numerados cronologicamente em número sequencial de caso (NSC). A LC foi realizada usando um spline cúbico restrito ajustado para o EuroSCORE-II e o uso de próteses de nova geração. Ainda, os desfechos hospitalares foram comparados entre grupos definidos de acordo com o nível de experiência, com base no NSC: 1º ao 40º caso (experiência inicial), 41º ao 80º caso (experiência básica), 81º ao 120º caso (experiência intermediária) e 121º caso em diante (experiência alta). Análises adicionais foram conduzidas de acordo com o número de casos tratados antes de 2014 (>40 e ≤40 procedimentos). O nível de significância adotado foi p <0,05. Resultados Foram incluídos 3194 pacientes de 25 centros. A idade média foi 80,7±8,1 anos e o EuroSCORE II médio foi 7±7,1. A análise da LC demonstrou uma queda na mortalidade hospitalar ajustada após o tratamento de 40 pacientes. Um patamar de nivelamento na curva foi observado após o caso 118. A mortalidade hospitalar entre os grupos foi 8,6%, 7,7%, 5,9%, e 3,7% para experiência inicial, básica, intermediária e alta, respectivamente (p<0,001). A experiência alta foi preditora independente de mortalidade mais baixa (OR 0,57, p=0,013 vs. experiência inicial). Centros com baixo volume de casos antes de 2014 não mostraram uma redução significativa na probabilidade de morte com o ganho de experiência, enquanto centros com alto volume de casos antes de 2014 apresentaram uma melhora contínua após o caso de número 10. Conclusão Observou-se um fenômeno de LC para a mortalidade hospitalar do TAVR no Brasil. Esse efeito foi mais pronunciado em centros que trataram seus 40 primeiros casos antes de 2014 que naqueles que o fizeram após 2014.


Abstract Background Robust data on the learning curve (LC) of transcatheter aortic valve replacement (TAVR) are lacking in developing countries. Objective To assess TAVR's LC in Brazil over time. Methods We analyzed data from the Brazilian TAVR registry from 2008 to 2023. Patients from each center were numbered chronologically in case sequence numbers (CSNs). LC was performed using restricted cubic splines adjusted for EuroSCORE-II and the use of new-generation prostheses. Also, in-hospital outcomes were compared between groups defined according to the level of experience based on the CSN: 1st to 40th (initial-experience), 41st to 80th (early-experience), 81st to 120th (intermediate-experience), and over 121st (high-experience). Additional analysis was performed grouping hospitals according to the number of cases treated before 2014 (>40 and ≤40 procedures). The level of significance adopted was <0.05. Results A total of 3,194 patients from 25 centers were included. Mean age and EuroSCORE II were 80.7±8.1 years and 7±7.1, respectively. LC analysis demonstrated a drop in adjusted in-hospital mortality after treating 40 patients. A leveling off of the curve was observed after case #118. In-hospital mortality across the groups was 8.6%, 7.7%, 5.9%, and 3.7% for initial-, early-, intermediate-, and high-experience, respectively (p<0.001). High experience independently predicted lower mortality (OR 0.57, p=0.013 vs. initial experience). Low-volume centers before 2014 showed no significant decrease in the likelihood of death with gained experience, whereas high-volume centers had a continuous improvement after case #10. Conclusion A TAVR LC phenomenon was observed for in-hospital mortality in Brazil. This effect was more pronounced in centers that treated their first 40 cases before 2014 than those that reached this milestone after 2014.

19.
Arq. bras. cardiol ; Arq. bras. cardiol;120(11): e20220496, 2023. tab, graf
Artículo en Portugués | LILACS-Express | LILACS | ID: biblio-1527782

RESUMEN

Resumo As inovações em dispositivos ao longo das últimas décadas proporcionaram uma melhora no diagnóstico e tratamento de pacientes com insuficiência cardíaca. Essas novas ferramentas progressivamente adaptaram-se a estratégias minimamente invasivas e as opções percutâneas multiplicaram-se de forma rápida. No presente artigo revisamos as direções atuais e futuras dos dispositivos utilizados como opções adjuvantes para o diagnóstico e tratamento adjuvante na insuficiência cardíaca crônica, o seu desenvolvimento, mecanismos e estudos mais recentes


Abstract Innovations in devices during the last decade contributed to enhanced diagnosis and treatment of patients with cardiac insufficiency. These tools progressively adapted to minimally invasive strategies with rapid, widespread use. The present article focuses on actual and future directions of device-related diagnosis and treatment of chronic heart failure.

20.
Int J Cardiovasc Imaging ; 33(2): 161-168, 2017 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-27714601

RESUMEN

We sought to compare, by means of IVUS and OCT imaging, the performance of a novel sirolimus-eluting drug-eluting stent (DES) with biodegradable polymer (Inspiron™) to the Biomatrix™ DES. From the DESTINY trial, a total of 70 randomized patients (2:1) were enrolled in the IVUS substudy (Inspiron™, n = 46; Biomatrix™: n = 20) while 25 patients were evaluated with OCT (Inspiron™, n = 19; Biomatrix™: n = 06) at 9-month follow-up. The main endpoints were % of neointimal tissue obstruction (IVUS) and neointimal stut coverage (OCT) at 9 months. Patients treated with both DES had very little NIH formation at 9 months either by IVUS (% of NIH obstruction of 4.9 ± 4.1 % with Inspiron™ vs. 2.7 ± 2.9 % with Biomatrix™, p = 0.03) or by OCT (neointimal thickness of 144.2 ± 72.5 µm Inspiron™ vs. 115.0 ± 53.9 µm with Biomatrix™, p = 0.45). Regarding OCT strut-level assessment, again both devices showed excellent 9-month performance, with high rates of strut coverage (99.49 ± 1.01 % with Inspiron™ vs. 97.62 ± 2.21 % with Biomatrix™, p < 0.001) and very rare malapposition (0.29 ± 1.06 % with Inspiron™ vs. 0.53 ± 0.82 % with Biomatrix™, p = 0.44). Patients with any uncovered struts were more frequently identified in the Biomatrix™ group (9.78 ± 7.13 vs. 2.29 ± 3.91 %, p < 0.001). In the present study, midterm IVUS and OCT evaluations showed that both new generation DES with biodegradable polymer were effective in terms of suppressing excessive neointimal response, with very high rates of apposed and covered struts, suggesting a consistent and benign healing pattern.


Asunto(s)
Implantes Absorbibles , Fármacos Cardiovasculares/administración & dosificación , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/terapia , Vasos Coronarios/efectos de los fármacos , Vasos Coronarios/diagnóstico por imagen , Stents Liberadores de Fármacos , Metales , Intervención Coronaria Percutánea/instrumentación , Polímeros/química , Sirolimus/análogos & derivados , Tomografía de Coherencia Óptica , Ultrasonografía Intervencional , Fármacos Cardiovasculares/efectos adversos , Humanos , Neointima , Intervención Coronaria Percutánea/efectos adversos , Valor Predictivo de las Pruebas , Diseño de Prótesis , Sirolimus/administración & dosificación , Sirolimus/efectos adversos , Factores de Tiempo , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA