RESUMEN
IMPORTANCE: The current recommendation is for at least 12 months of dual antiplatelet therapy after implantation of a drug-eluting stent. However, the optimal duration of dual antiplatelet therapy with specific types of drug-eluting stents remains unknown. OBJECTIVE: To assess the clinical noninferiority of 3 months (short-term) vs 12 months (long-term) of dual antiplatelet therapy in patients undergoing percutaneous coronary intervention (PCI) with zotarolimus-eluting stents. DESIGN, SETTING, AND PATIENTS: The OPTIMIZE trial was an open-label, active-controlled, 1:1 randomized noninferiority study including 3119 patients in 33 sites in Brazil between April 2010 and March 2012. Clinical follow-up was performed at 1, 3, 6, and 12 months. Eligible patients were those with stable coronary artery disease or history of low-risk acute coronary syndrome (ACS) undergoing PCI with zotarolimus-eluting stents. INTERVENTIONS: After PCI with zotarolimus-eluting stents, patients were prescribed aspirin (100-200 mg daily) and clopidogrel (75 mg daily) for 3 months (n = 1563) or 12 months (n = 1556), unless contraindicated because of occurrence of an end point. MAIN OUTCOMES AND MEASURES: The primary end point was net adverse clinical and cerebral events (NACCE; a composite of all-cause death, myocardial infarction [MI], stroke, or major bleeding); the expected event rate at 1 year was 9%, with a noninferiority margin of 2.7%. Secondary end points were major adverse cardiac events (MACE; a composite of all-cause death, MI, emergent coronary artery bypass graft surgery, or target lesion revascularization) and Academic Research Consortium definite or probable stent thrombosis. RESULTS: NACCE occurred in 93 patients receiving short-term and 90 patients receiving long-term therapy (6.0% vs 5.8%, respectively; risk difference, 0.17 [95% CI, -1.52 to 1.86]; P = .002 for noninferiority). Kaplan-Meier estimates demonstrated MACE rates at 1 year of 8.3% (128) in the short-term group and 7.4% (114) in the long-term group (HR, 1.12 [95% CI, 0.87-1.45]). Between 91 and 360 days, no statistically significant association was observed for NACCE (39 [2.6%] vs 38 [2.6%] for the short- and long-term groups, respectively; HR, 1.03 [95% CI, 0.66-1.60]), MACE (78 [5.3%] vs 64 [4.3%]; HR, 1.22 [95% CI, 0.88-1.70]), or stent thrombosis (4 [0.3%] vs 1 [0.1%]; HR, 3.97 [95% CI, 0.44-35.49]). CONCLUSIONS AND RELEVANCE: In patients with stable coronary artery disease or low-risk ACS treated with zotarolimus-eluting stents, 3 months of dual antiplatelet therapy was noninferior to 12 months for NACCE, without significantly increasing the risk of stent thrombosis. TRIAL REGISTRATION: clinicaltrials.gov Identifier: NCT01113372.
Asunto(s)
Síndrome Coronario Agudo/terapia , Aspirina/administración & dosificación , Enfermedad de la Arteria Coronaria/terapia , Stents Liberadores de Fármacos , Inhibidores de Agregación Plaquetaria/administración & dosificación , Ticlopidina/análogos & derivados , Anciano , Aspirina/efectos adversos , Clopidogrel , Esquema de Medicación , Quimioterapia Combinada , Femenino , Hemorragia , Humanos , Masculino , Persona de Mediana Edad , Infarto del Miocardio , Inhibidores de Agregación Plaquetaria/efectos adversos , Riesgo , Sirolimus/administración & dosificación , Sirolimus/análogos & derivados , Accidente Cerebrovascular , Trombosis , Ticlopidina/administración & dosificación , Ticlopidina/efectos adversosRESUMEN
OBJECTIVES: This study sought to report the late multimodality imaging and clinical outcomes of the novel poly-l-lactic-acid-based DESolve novolimus-eluting bioresorbable coronary scaffold for the treatment of de novo coronary lesions. BACKGROUND: Bioresorbable scaffolds are an alternative to drug-eluting metallic stents and provide temporary vascular scaffolding, which potentially may allow vessel restoration and reduce the risk of future adverse events. METHODS: Overall, 126 patients were enrolled at 13 international sites between November 2011 and June 2012. The primary endpoint was in-scaffold late lumen loss at 6 months. Major adverse cardiac events, the main safety endpoint, were defined as the composite of cardiac death, target vessel myocardial infarction, or clinically indicated target lesion revascularization. All patients underwent angiography at 6 months. Serial intravascular ultrasound and optical coherence tomography were performed in a subset of patients. RESULTS: The scaffold device success rate was 97% (n = 122 of 126), and procedural success was 100% (n = 122 of 122). The major adverse cardiac event rate was 3.3% (n = 4 of 122) at 6 months and 7.4% (n = 9 of 122) at 24 months, including 1 probable stent thrombosis within the first month. At 6-month angiographic follow-up, in-scaffold late lumen loss was 0.20 ± 0.32 mm. Paired intravascular ultrasound analysis demonstrated a significant increase in vessel, lumen and scaffold dimensions between post-procedure and 6-month follow-up, and strut-level optical coherence tomography analysis showed full strut coverage in 99 ± 1.7%. CONCLUSIONS: Our results showed favorable performance of the DESolve scaffold, effective inhibition of neointimal hyperplasia, and for the first time, early luminal and scaffold growth at 6 months with sustained efficacy and safety through 2 years. (Elixir Medical Clinical Evaluation of the DESolve Novolimus Eluting Bioresorbable Coronary Scaffold System-The DESolve Nx Trial; NCT02086045).
Asunto(s)
Implantes Absorbibles , Fármacos Cardiovasculares/administración & dosificación , Materiales Biocompatibles Revestidos , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/terapia , Vasos Coronarios/efectos de los fármacos , Macrólidos/administración & dosificación , Intervención Coronaria Percutánea/instrumentación , Tomografía de Coherencia Óptica , Ultrasonografía Intervencional , Anciano , Brasil , Fármacos Cardiovasculares/efectos adversos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/mortalidad , Vasos Coronarios/diagnóstico por imagen , Europa (Continente) , Femenino , Humanos , Hiperplasia , Macrólidos/efectos adversos , Masculino , Persona de Mediana Edad , Neointima , Nueva Zelanda , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/mortalidad , Valor Predictivo de las Pruebas , Estudios Prospectivos , Factores de Tiempo , Resultado del TratamientoRESUMEN
BACKGROUND: The safety and efficacy of sirolimus-eluting stenting have been demonstrated, but the outcome of patients treated with this novel technology beyond the first year remains unknown. We sought to evaluate the angiographic, intravascular ultrasound (IVUS), and clinical outcomes of patients treated with sirolimus-eluting stents 2 years after implantation. METHODS AND RESULTS: This study included 30 patients treated with sirolimus-eluting Bx Velocity stenting (slow release [SR], n=15, and fast release [FR], n=15) in São Paulo, Brazil. Twenty-eight patients underwent 2-year angiographic and IVUS follow-up. No deaths occurred during the study period. In-stent late loss was slightly greater in the FR group (0.28+/-0.4 mm) than in the SR group (-0.09+/-0.23 mm, P=0.007). No patient had in-stent restenosis. At 2-year follow-up, only 1 patient (FR group) had a 52% diameter stenosis within the lesion segment, which required repeat revascularization. The target-vessel revascularization rate for the entire cohort was 10% (3/30) at 2 years. All other patients had < or =35% diameter stenosis. Angiographic lumen loss at the stent edges was also minimal (in-lesion late loss was 0.33+/-0.42 mm [FR] and 0.13+/-0.29 mm [SR]). In-stent neointimal hyperplasia volume, as detected by IVUS, remained minimal after 2 years (FR= 9.90+/-9 mm3 and SR=10.35+/-9.3 mm3). CONCLUSIONS: This study demonstrates the safety and efficacy of sirolimus-eluting Bx Velocity stents 2 years after implantation in humans. In-stent lumen dimensions remained essentially unchanged at 2-year follow-up in the 2 groups, although angiographic lumen loss was slightly higher in the FR group. Restenosis "catch-up" was not found in our patient population.
Asunto(s)
Enfermedad de la Arteria Coronaria , Sirolimus/administración & dosificación , Stents , Terapia Combinada , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/tratamiento farmacológico , Enfermedad de la Arteria Coronaria/cirugía , Reestenosis Coronaria/prevención & control , Vasos Coronarios/diagnóstico por imagen , Vasos Coronarios/cirugía , Preparaciones de Acción Retardada , Estudios de Seguimiento , Humanos , Sirolimus/uso terapéutico , Stents/efectos adversos , Resultado del Tratamiento , UltrasonografíaRESUMEN
BACKGROUND: We have previously reported the safety and effectiveness of sirolimus-eluting stents for the treatment of de novo coronary lesions. The present investigation explored the potential of this technology to treat in-stent restenosis. METHODS AND RESULTS: Twenty-five patients with in-stent restenosis were successfully treated with the implantation of 1 or 2 sirolimus-eluting Bx VELOCITY stents in São Paulo, Brazil. Nine patients received 2 stents (1.4 stents per lesion). Angiographic and volumetric intravascular ultrasound (IVUS) images were obtained after the procedure and at 4 and 12 months. All vessels were patent at the time of 12-month angiography. Angiographic late loss averaged 0.07+/-0.2 mm in-stent and -0.05+/-0.3 mm in-lesion at 4 months, and 0.36+/-0.46 mm in-stent and 0.16+/-0.42 mm in-lesion after 12 months. No patient had in-stent or stent margin restenosis at 4 months, and only one patient developed in-stent restenosis at 1-year follow-up. Intimal hyperplasia by 3-dimensional IVUS was 0.92+/-1.9 mm(3) at 4 months and 2.55+/-4.9 mm(3) after 1 year. Percent volume obstruction was 0.81+/-1.7% and 1.76+/-3.4% at the 4- and 12-month follow-up, respectively. There was no evidence of stent malapposition either acutely or in the follow-up IVUS images, and there were no deaths, stent thromboses, or repeat revascularizations. CONCLUSION: This study demonstrates the safety and the potential utility of sirolimus-eluting Bx VELOCITY stents for the treatment of in-stent restenosis.
Asunto(s)
Reestenosis Coronaria/tratamiento farmacológico , Sirolimus/administración & dosificación , Stents , Terapia Combinada , Angiografía Coronaria , Reestenosis Coronaria/diagnóstico por imagen , Reestenosis Coronaria/cirugía , Preparaciones de Acción Retardada , Ecocardiografía Tridimensional , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Proyectos Piloto , Prevención Secundaria , Sirolimus/uso terapéutico , Stents/efectos adversosRESUMEN
OBJECTIVES: The purpose of the study was to examine the safety and efficacy of 17-beta-estradiol-eluting stent implantation on coronary de novo lesions. BACKGROUND: Recent animal data indicate that local delivery of 17-beta-estradiol promotes re-endothelialization, inhibits cell migration and proliferation, and prevents restenosis. METHODS: A total of 30 consecutive patients underwent 17-beta-estradiol-eluting BiodVysio (Biocompatibles Ltd., London, United Kingdom) stent implantation for the treatment of coronary de novo lesions. Clinical, angiographic, and intravascular ultrasound (IVUS) analysis was performed at six-month follow-up. RESULTS: All stents were successfully deployed and patients were discharged home without clinical events. A total of two patients exceeded 50% intra-stent narrowing by angiography, whereas no patients experienced edge restenosis. One patient had focal intra-stent restenosis (60% diameter stenosis) with no symptoms and negative stress test, whereas the other patient had diffuse restenosis, requiring target vessel revascularization. No other patient experienced any major adverse cardiac event. Follow-up IVUS revealed a neointimal hyperplasia volume of 32.3 +/- 16.4 mm(3), whereas the stent volume was 143.7 +/- 43.7 mm(3), resulting in a neointimal volume obstruction of 23.5 +/- 12.5%. None of the patients had > or =50% volume obstruction by IVUS. CONCLUSIONS: Implantation of 17-beta-estradiol-eluted BiodVysio stents appears feasible and safe, showing low rates of binary restenosis and revascularization. These results warrant further confirmation with a large, randomized multicenter trial.
Asunto(s)
Angioplastia Coronaria con Balón/métodos , Enfermedad de la Arteria Coronaria/terapia , Estradiol/administración & dosificación , Stents , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/patología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Resultado del Tratamiento , Ultrasonografía IntervencionalRESUMEN
We performed serial intravascular ultrasound analysis in patients who underwent balloon dilatation for in-stent restenosis. Early lumen loss was detected by intravascular ultrasound and was associated with minimal changes at the edges and at the external elastic membrane. These results on intravascular ultrasound suggest compression and decompression as the main mechanisms for early lumen loss after dilatation of in-stent restenotic lesions.
Asunto(s)
Angioplastia Coronaria con Balón , Reestenosis Coronaria/terapia , Stents , Ultrasonografía Intervencional , Adulto , Anciano , Braquiterapia , Terapia Combinada , Angiografía Coronaria , Reestenosis Coronaria/diagnóstico , Tejido Elástico/patología , Análisis de Falla de Equipo , Femenino , Displasia Fibromuscular/diagnóstico , Displasia Fibromuscular/terapia , Humanos , Masculino , Persona de Mediana Edad , Factores de RiesgoRESUMEN
We report the outcomes of patients who had in-stent restenosis (IRS) that was treated with intravascular brachytherapy (IVBT) or sirolimus-eluting stent (SES) implantation. The benefit of IVBT for treating ISR is well documented. SES implantation decreases first-time ISR and, in preliminary reports, has been used to treat ISR. Fifty consecutive patients who had ISR were treated; the first 25 patients underwent SES implantation and the next 25 patients were treated with IVBT using a beta-Cath System (a 40-mm strontium-90/yttrium-90 source). Quantitative angiographic and intravascular ultrasound follow-up were performed at 5.2 +/- 1.1 and 12.1 +/- 1.2 months; clinical follow-up was performed at 15 months. SES deployment and IVBT were successful in all patients. At 12-month follow-up, 8 patients who underwent IVBT had angiographic recurrence (4 in the stent and 4 at the stent edge); only 1 patient who underwent SES implantation developed recurrent ISR. At 12 months, in-stent late luminal loss was similar between the SES and IVBT groups (0.35 +/- 0.45 vs 0.34 +/- 0.46 mm, p = 0.9); however, in-stent net luminal gain was higher in the SES group than in the IVBT group (1.32 +/- 0.13 vs 0.57 +/- 0.19 mm, p <0.0001), and in-lesion late luminal loss was higher in the IVBT group (0.48 +/- 0.32 vs 0.16 +/- 0.42 mm, p = 0.004). At 12 months, intravascular ultrasound stent volume obstruction was higher after IVBT versus than after SES implantation (38.7% vs 6.7%, p <0.0001). At 15-month clinical follow-up, 64% and 96% (p <0.01) of patients who underwent IVBT and SES implantation, respectively, were free of major adverse cardiac events. In conclusion SES implantation for the treatment of ISR was effective and superior to catheter-based IVBT in preventing recurrent neointimal proliferation and angiographic restenosis at 1-year follow-up.
Asunto(s)
Implantación de Prótesis Vascular/instrumentación , Braquiterapia/métodos , Materiales Biocompatibles Revestidos , Reestenosis Coronaria/terapia , Oclusión de Injerto Vascular/terapia , Sirolimus/uso terapéutico , Stents , Cateterismo Periférico , Angiografía Coronaria , Reestenosis Coronaria/diagnóstico por imagen , Vasos Coronarios/diagnóstico por imagen , Vasos Coronarios/efectos de los fármacos , Vasos Coronarios/efectos de la radiación , Femenino , Estudios de Seguimiento , Oclusión de Injerto Vascular/diagnóstico por imagen , Humanos , Inmunosupresores/uso terapéutico , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Reoperación , Prevención Secundaria , Resultado del Tratamiento , Ultrasonografía IntervencionalRESUMEN
Conventional sirolimus-eluting stent (SES) implantation typically follows balloon predilation. The impact of direct SES implantation on in-stent neointimal hyperplasia and the adjacent reference segments has not been evaluated. The aim of this study was to analyze direct and conventional SES implantation techniques by angiography and serial intravascular ultrasound. Fifty-three patients with single de novo coronary lesions underwent successful conventional (n = 26) and direct (n = 27) SES implantation. At 6-month follow-up, similar in-stent late luminal loss and decreased neointimal hyperplasia volume were seen in the 2 groups, preserving the luminal dimensions at the edges of the stents.
Asunto(s)
Angioplastia Coronaria con Balón , Implantación de Prótesis Vascular/métodos , Inmunosupresores/administración & dosificación , Sirolimus/administración & dosificación , Stents , Angiografía Coronaria , Vasos Coronarios/diagnóstico por imagen , Vasos Coronarios/patología , Femenino , Humanos , Hiperplasia/patología , Masculino , Persona de Mediana Edad , Evaluación de Resultado en la Atención de Salud , Túnica Íntima/patología , Ultrasonografía IntervencionalRESUMEN
Drug-eluting stents have been investigated as a treatment option for in-stent restenosis after bare metal stenting. However, it remains unclear whether overlapping drug-eluting stents have a toxic effect on the vessel wall. The aim of this study was to analyze the 1-year intravascular ultrasound findings after 2 overlapping sirolimus-eluting stent implantations in patients with in-stent restenosis lesions. Eight patients required 2 sirolimus-eluting stents, 18 mm in length, for full lesion coverage; these stents were implanted with >1-mm overlap. At 1-year follow-up, there were no significant quantitative changes in intravascular ultrasound measurements within the overlapped segment.
Asunto(s)
Reestenosis Coronaria/diagnóstico por imagen , Reestenosis Coronaria/tratamiento farmacológico , Vasos Coronarios/diagnóstico por imagen , Inmunosupresores/administración & dosificación , Sirolimus/administración & dosificación , Stents , Sistemas de Liberación de Medicamentos , Femenino , Humanos , Hiperplasia/diagnóstico por imagen , Hiperplasia/prevención & control , Inmunosupresores/efectos adversos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Sirolimus/efectos adversos , UltrasonografíaAsunto(s)
Implantes Absorbibles , Materiales Biocompatibles/uso terapéutico , Enfermedad de la Arteria Coronaria/terapia , Estenosis Coronaria/tratamiento farmacológico , Stents Liberadores de Fármacos , Inmunosupresores/uso terapéutico , Macrólidos/uso terapéutico , Intervención Coronaria Percutánea , Estenosis Coronaria/cirugía , Humanos , Resultado del TratamientoRESUMEN
OBJECTIVES: This study sought to perform clinical and imaging assessments of the DESolve Bioresorbable Coronary Scaffold (BCS). BACKGROUND: BCS, which is drug eluting, may have potential advantages compared with conventional metallic drug-eluting stents. The DESolve system, designed to provide vessel support and neointimal suppression, combines a poly-l-lactic acid-based scaffold with the antiproliferative myolimus. METHODS: The DESolve First-in-Man (a non-randomized, consecutive enrollment evaluation of the DESolve myolimus eluting bioresorbable coronary stent in the treatment of patients with de novo native coronary artery lesions) trial was a prospective multicenter study enrolling 16 patients eligible for treatment. The principal safety endpoint was a composite of cardiac death, myocardial infarction, and clinically indicated target lesion revascularization. The principal imaging endpoint was in-scaffold late lumen loss (LLL) assessed by quantitative coronary angiography (QCA) at 6 months. Intravascular ultrasound (IVUS) and optical coherence tomography (OCT) imaging was performed at baseline and 6 months; multislice computed tomography (MSCT) was performed at 12 months. RESULTS: Acute procedural success was achieved in 15 of 15 patients receiving a study scaffold. At 12 months, there was no scaffold thrombosis and no major adverse cardiac events directly attributable to the scaffold. At 6 months, in-scaffold LLL (by QCA) was 0.19 ± 0.19 mm; neointimal volume (by IVUS) was 7.19 ± 3.56%, with no evidence of scaffold recoil or late malapposition. Findings were confirmed with OCT and showed uniform, thin neointimal coverage (0.12 ± 0.04 mm). At 12 months, MSCT demonstrated excellent vessel patency. CONCLUSIONS: This study demonstrated the feasibility and efficacy of the DESolve BCS. Results showing low in-scaffold LLL, low % neointimal volume at 6 months, no chronic recoil, and maintenance of lumen patency at 12 months prompt further study. (DESolve First-in-Man; EudraCT number 2011-000027-32).
Asunto(s)
Implantes Absorbibles , Fármacos Cardiovasculares/administración & dosificación , Enfermedad de la Arteria Coronaria/terapia , Stents Liberadores de Fármacos , Imagen Multimodal , Intervención Coronaria Percutánea/instrumentación , Andamios del Tejido , Anciano , Anciano de 80 o más Años , Bélgica , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico , Enfermedad de la Arteria Coronaria/mortalidad , Enfermedad de la Arteria Coronaria/fisiopatología , Reestenosis Coronaria/diagnóstico , Reestenosis Coronaria/etiología , Femenino , Humanos , Ácido Láctico/química , Masculino , Ensayo de Materiales , Modelos Cardiovasculares , Tomografía Computarizada Multidetector , Imagen Multimodal/métodos , Infarto del Miocardio/diagnóstico , Infarto del Miocardio/etiología , Neointima , Nueva Zelanda , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/mortalidad , Poliésteres , Polímeros/química , Valor Predictivo de las Pruebas , Estudios Prospectivos , Diseño de Prótesis , Factores de Tiempo , Tomografía de Coherencia Óptica , Resultado del Tratamiento , Ultrasonografía Intervencional , Grado de Desobstrucción VascularRESUMEN
BACKGROUND: Small vessels represent a risk factor for restenosis in percutaneous coronary angioplasty (PCA). The Sparrow® self-expanding drug-eluting stent, which has a lower profile than the current systems, has never been tested in this scenario. OBJECTIVES: To evaluate the late effectiveness of the Sparrow® drug-eluting stent, regarding in-stent late lumen loss (LLL). METHODS: Patients with ischemia, symptomatic or documented, were submitted to PCA in vessels with reference diameter < 2.75 mm, divided into two groups regarding Sparrow® stent type: group 1: Sparrow® drug-eluting stent (DES), group 2: Sparrow® bare metal stent (BMS). Clinical follow-up duration was 12 months. Evaluation using quantitative coronary angiography (QCA) was performed immediately and at 8 months. A decrease of over 65% of in-stent LLL with DES was estimated to calculate sample size. IBM® SPSS software, release 19 (Chicago, Illinois, USA) was used for the statistical analysis. RESULTS: A total of 24 patients were randomized, 12 in each group. The DES and BMS groups were similar in age (63.25 ± 10.01 vs. 64.58 ± 11.54, p = 0.765), male gender (58.3% vs. 33.3%, p = 0.412), risk factors and all angiographs aspects. Immediate results were satisfactory in both groups. At 8 months in-stent late lumen loss was significantly lower in DES than in BMS group (DES vs. BMS 0.25 ± 0.16 0.97 ± 0.76, p = 0.008). CONCLUSION: In small-vessel PCA, the Sparrow® DES determined significant reduction in in-stent LLL, when compared to Sparrow® BMS.
Asunto(s)
Reestenosis Coronaria/prevención & control , Vasos Coronarios/fisiopatología , Stents Liberadores de Fármacos , Miniaturización , Anciano , Angioplastia Coronaria con Balón , Estenosis Coronaria , Femenino , Humanos , Masculino , Persona de Mediana Edad , Sirolimus/administración & dosificación , Stents , Resultado del TratamientoRESUMEN
AIMS: To demonstrate the acute and early outcomes of the novel Nile PAX dedicated polymer-free paclitaxel-coated stents (Minvasys SAS, Gennevilliers, France) in the treatment of de novo coronary bifurcation lesions. METHODS AND RESULTS: The Nile PAX device incorporates a cobalt-chromium alloy with a side aperture in the mid-stent designed to optimise scaffold at the bifurcation carina and side branch (SB) ostium, while maintaining SB access during procedure. From December 2008 to February 2010, 101 patients were prospectively enrolled in a non-randomised, multicentre study. Lesion criteria were: vessel size 2.5-3.5 mm in the parent vessel (PV) and 2.0-3.0 mm in the SB, and lesion length <14 mm in the PV, and <5 mm in the SB. Mean age was 63 years, 29% had diabetes, LAD/Dg was involved in 80.4%, and 61.7% had significant involvement of both branches. The study stent was successfully attempted and implanted in 98%. SB received additional stent in 26% final kissing-balloon inflation was performed in 93% and lesion (angiographic) success was achieved in 98%. There was only one non-Q myocardial infarction during hospitalisation, and no additional events up to 30 days. CONCLUSIONS: Preliminary results of the prospective, non-randomised, multicentre BIPAX clinical trial demonstrated encouraging results with the novel Nile PAX bifurcation DES in the treatment of coronary bifurcation lesions, including high device and procedural success. Overall, there was only one major adverse cardiac event during hospitalisation, with no additional events up to 30 days follow-up. Long-term follow-up is warranted.
Asunto(s)
Angioplastia Coronaria con Balón/instrumentación , Enfermedad de la Arteria Coronaria/terapia , Reestenosis Coronaria/prevención & control , Stents Liberadores de Fármacos , Paclitaxel/administración & dosificación , Anciano , Angioplastia Coronaria con Balón/efectos adversos , Angioplastia Coronaria con Balón/métodos , Aleaciones de Cromo , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Stents Liberadores de Fármacos/efectos adversos , Femenino , Humanos , Tiempo de Internación , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Moduladores de Tubulina/administración & dosificaciónRESUMEN
O stent liberador de everolimus XIENCE V® é um stent farmacológico de nova geração que incorpora uma plataforma de cromo-cobalto de baixo perfil (81 m) e um polímero de elevada biocompatibilidade (fluoropolímero), o qual carreia e controla a liberação do fármaco everolimus. Estudos recentes demonstram segurança e eficácia sustentadas do dispositivo XIENCE V® no tratamento de populações da prática clínica. Nosso objetivo foi reportar resultados clínicos de 12 meses do protocolo brasileiro BRAVO. Métodos: O registro BRAVO foi um estudo prospectivo, não randomizado, de braço único, multicêntrico (25centros), que avaliou os resultados clínicos tardios de 535 pacientes minimamente selecionados, tratados com o stent farmacológico XIENCE V®.Resultados: Cerca de 40% dos pacientes tinham diabetes, 25% infarto agudo do miocárdio prévio e 42% apresentaram-se com síndrome coronária aguda. A maioria das lesões (69%) era de elevada complexidade(ACC/AHA tipo B2/C). As médias da extensão e do diâmetro nominais dos stents foram, respectivamente, 19,9 ± 5,3 mm e 3,0 ± 0,4 mm. Os sucessos angiográfico e de procedimento foram de 99,7 e 98%, respectivamente. Aos 12 meses, a taxa cumulativa de eventos cardíacos adversos maiores, disponível em 100% dos pacientes, foi de 5,6% (morte cardíaca: 1,3%; infarto agudo do miocárdio: 3,0%; revascularização da lesão-alvo: 2,2%). Já a trombose de stent ocorreu em cinco pacientes (0,9%), sendo reportada apenas uma ocorrência entre 6 e 12 meses. Conclusões: O stent farmacológico XIENCE V® demonstrou segurança e eficácia sustentadas ao final de 12meses no tratamento de lesões coronárias complexas em pacientes da prática diária...
The Xience VTM everolimus-eluting stents is a new generation drug-eluting stent (DES)that incorporates a low profile cobalt-chromium platform (81 m) and a highly biocompatible polymer(fluoropolymer), which carries and controls the release of everolimus. Recent studies have demonstrated sustained safety and efficacy of the Xience VTM in the treatment of real-world populations. Our aim was to report the clinical results of 12 months of the BRAVO Brazilian protocol. Methods: The BRAVO Registry was a prospective, non-randomized, single-arm, multicenter (25 centers) study that evaluated the late clinical results of 535 minimally selected patients treated with the drug eluting stent Xience VTM in Brazilian daily practice. Results: Overall, 40% of patients had diabetes, 25% prior myocardial infarction, and 42% presented with acute coronary artery syndrome. The majority of lesions (69%) was highly complex (ACC/AHA type B2 or C).The mean length and the nominal stent diameter were 19.9 ± 5.3 mm and 3.0 ± 0.4 mm, respectively.The angiographic and procedural successes were 99.7 and 98%, respectively. At 12 months, the cumulative rate of major adverse cardiac events, available in 100% of patients, was 5.6% (cardiac death: 1.3%; acute myocardial infarction: 3.0%; revascularization of the target lesion: 2.2%). Stent thrombosis occurred in 5 patients (0,9%), and only 1 case was reported between 6 and 12 months. Conclusions: The drug-eluting stent Xience V demonstrated sustained safety and efficacy up to 12 months in the treatment of complex coronary lesions in patients from daily practice...
Asunto(s)
Humanos , Masculino , Femenino , Persona de Mediana Edad , Enfermedad Coronaria , Intervención Coronaria Percutánea/métodos , Pacientes , Stents Liberadores de Fármacos , Trombosis/complicaciones , Trombosis/diagnóstico , Interpretación Estadística de Datos , Estudios Prospectivos , Factores de Riesgo , Prótesis e Implantes/métodos , Resultado del TratamientoRESUMEN
Introdução: O stent farmacológico liberador de sirolimus Firebird® já demonstrou eficácia na inibição de hiperplasia neointimal em pacientes selecionados submetidos à intervenção coronária percutânea. Nosso objetivo foi avaliar o desempenho e o resultado clínico tardio do dispositivo Firebird® em pacientes submetidos à intervenção coronária percutânea na prática diária nacional. Métodos: O Registro CLARIFIRE foi um estudo prospectivo, não randomizado, multicêntrico, que incluiu 455 pacientes (536 lesões) em 14 centros no Brasil entre dezembro de 2008 e maio de 2011. O seguimento clínico foi realizado aos 1, 6, 12 e 24 meses, e os eventos adversos foram adjudicados por um Comitê de Eventos Clínicos independente. Resultados: A média das idades foi de 61,1 ± 10,4 anos, 30,8% eram do sexo feminino, 41,9% tinham diabetes e 58,2% apresentaram-se com angina estável. O vaso-alvo mais prevalente foi a artéria descendente anterior (46,5%), 29,9% eram lesões reestenóticas e 8% lesões em bifurcação. Foram implantados 613 stents e as médias de extensão e diâmetro nominal dos stents foram 22,0 ± 6,4 mm e 2,90 ± 0,40 mm, respectivamente. O sucesso do procedimento foi de 97,6%. A taxa cumulativa de eventos cardíacos adversos maiores aos 12 meses (desfecho primário) foi 8,1%. Considerando-se os eventos pós-hospitalização até 24 meses (409/455), observaram-se eventos cardíacos adversos maiores em 9,8%, morte cardíaca em 3,9% e revascularização do vaso-alvo em 7,6%. Já a trombose de stent (definitiva/provável) ocorreu em nove casos (2%) até 30 dias, sem ocorrências subsequentes. Conclusões: O stent farmacológico liberador de sirolimus Firebird ® demonstrou desempenho favorável, Além de segurança e eficácia sustentadas no tratamento de pacientes da prática diária, conforme evidenciado pela elevada taxa de sucesso do procedimento e pela ocorrência relativamente baixa de eventos adversos ao final de 2 anos...
Background: The Firebird sirolimus-eluting stent has proven to be effective in inhibiting neointimal hyperplasia in selected patients undergoing percutaneous coronary intervention. Our objective was to evaluate the performance and long-term outcomes of Firebird in patients undergoing percutaneous coronary intervention in daily practice in Brazil. Methods: The CLARIFIRE Registry was a prospective, non-randomized, multicenter study enrolling 455 patients (536 lesions) in 14 Brazilian sites between December 2008 and May 2011. Clinical follow-up was performed at 1, 6, 12, and 24 months, and adverse events were adjudicated by the independent Clinical Events Committee. Results: Mean age was 61.1 ± 10.4 years, 30.8% were women, 41.9% had diabetes, and 58.2% had stable angina. The left anterior descending artery was the most prevalent target vessel (46.5%), 29.9% were restenotic lesions, and 8% were bifurcations. Six hundred and thirteen stents were implanted, and the mean nominal stent length and diameter were 22.0 ± 6.4 mm and 2.90 ± 0.40 mm, respectively. Procedural success was 97.6%. The cumulative major adverse cardiac events rate at 12 months (primary endpoint) was 8.1%. Considering post-discharge events up to 24 months (409/455), major adverse cardiac events were observed in 9.8%, cardiac death in 3.9%, and target vessel revascularization in 7.6% of the patients. Definite/probable stent thrombosis was observed in nine cases (2%) up to 30 days, and no further occurrences were found. Conclusions: The Firebird sirolimus-eluting stent has demonstrated good performance and sustained safety and efficacy for patients treated in daily practice, as evidenced by the high procedural success rates and relatively low adverse event rates after 2 years...
Asunto(s)
Humanos , Masculino , Femenino , Anciano , Stents Liberadores de Fármacos , Enfermedad de la Arteria Coronaria/terapia , Sirolimus , Resultado del Tratamiento , Diabetes Mellitus , Electrocardiografía/métodos , Inhibidores de Agregación Plaquetaria/administración & dosificación , Intervención Coronaria Percutánea/métodos , Polímeros , Estudios Prospectivos , Vasos Coronarios/fisiopatologíaRESUMEN
BACKGROUND: Despite the advances in interventional cardiology, stent expansion remains an important predictor of success, impacting restenosis and thrombosis rates after either bare-metal (BMS) or drug-eluting stent implantation. Especially for the treatment of complex lesions (e.g., calcified lesions, in-stent restenosis, etc.), adequate lesion preparation might help improve procedural results as well as clinical outcomes. We sought to investigate the safety, feasibility and mechanism of action of a new scoring-balloon catheter, the AngioSculpt, comprised of a semicompliant balloon and a nitinol spiral cage designed to address complex lesions. METHODS: A total of 60 consecutive patients at two centers were prospectively enrolled in this first-in-man coronary study and divided into two groups according to the type of lesion treated: Group I: patients with de novo coronary lesions (n = 47) as a pretreatment strategy before BMS implantation, and Group II: patients with BMS restenosis (n = 17) as a standalone therapy. A subgroup of patients in each cohort was assigned to intravascular (IVUS) analysis. Patients in Group II were submitted to routine 6-month follow-up angiography. In Group I, angiographic restudy was contingent upon the presence of ischemia. Lesions longer than 20 mm in very tortuous vessels, in arterial or vein grafts, in the setting of acute myocardial infarction or with visible thrombus were excluded from this study. RESULTS: Success was achieved in all cases. The mean age of the study populations was 62 +/- 11.6 years (Group I) and 53 +/- 9.4 years (Group II), with 26% and 18% diabetics, respectively. In Group I, 73% of lesions were diffuse and fibrocalcified, while in Group II, 72% were classified as diffuse. No serious complications were observed in either group. Balloon slippage (or the "watermelon seed" phenomenon) was not observed. Significant acute gain was achieved in both groups (0.7 mm in Group I and 1.64 mm in Group II). A minimum final area (in-stent) 6.5 mm2 was achieved in 85% of the cases in Group I and in 82% of the cases in Group II. CONCLUSIONS: In this preliminary in vivo study, the use AngioSculpt(R) proved to be feasible and safe for the treatment of complex coronary lesions. Six-month results suggest the use of this novel device as an attractive option for the percutaneous approach of restenotic coronary lesions and should be assessed in a larger, more complex cohort of patients.
Asunto(s)
Angioplastia Coronaria con Balón/instrumentación , Estenosis Coronaria/diagnóstico por imagen , Estenosis Coronaria/terapia , Stents , Ultrasonografía Intervencional , Anciano , Angioplastia Coronaria con Balón/métodos , Cateterismo , Reestenosis Coronaria/prevención & control , Stents Liberadores de Fármacos , Diseño de Equipo , Seguridad de Equipos , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Medición de Riesgo , Sensibilidad y Especificidad , Índice de Severidad de la Enfermedad , Resultado del Tratamiento , Grado de Desobstrucción VascularRESUMEN
FUNDAMENTO: Na angioplastia coronária percutânea (ACP), os vasos de fino calibre representam um fator de risco para reestenose. O stent farmacológico (SF) autoexpansível Sparrow®, de perfil menor que os sistemas atuais, nunca foi testado nesse cenário. OBJETIVOS: Avaliar a eficácia tardia do SF Sparrow®, com relação à perda luminal tardia intrastent (PLT intrastent) aos oito meses. MÉTODOS: Estudo prospectivo, randomizado, em P com doença arterial coronária (DAC) sintomática ou com isquemia documentada, submetido à ACP em vasos de calibre < 2,75 mm, dividido em dois grupos quanto ao tipo de stent Sparrow®: grupo 1, SF; grupo 2, stent não farmacológico (SNF). O seguimento clínico foi de 12 meses. De imediato e aos oito meses, avaliação pela angiografia coronária quantitativa (ACQ). Para o cálculo da amostra estimou-se diminuição de mais de 65% de PLT intrastent com o SF. Para análise estatística utilizou-se o programa IBM SPSS Statistics® versão 19 (Chicago, Illinois, EUA). RESULTADOS: Foram incluídos 24 p, 12 em cada grupo. Os grupos SF e SNF foram semelhantes quanto à idade (63,25 ± 10,01 versus 64,58 ± 11,54, p = 0,765), sexo masculino (58,3% versus 33,3%, p = 0,412), fatores de risco e todos os aspectos angiográficos. Os resultados imediatos foram satisfatórios em ambos os grupos. Aos oito meses, a PLT intrastent foi significativamente menor no SF do que no SNF (SF 0,25 ± 0,16 versus SNF 0,97 ± 0,76, p = 0,008). CONCLUSÃO: Em ACP de vasos de calibre < 2,75 mm, o SF Sparrow® determinou significativa redução da PLT intrastent, em comparação ao SNF Sparrow®.
BACKGROUND: Small vessels represent a risk factor for restenosis in percutaneous coronary angioplasty (PCA). The Sparrow® self-expanding drug-eluting stent, which has a lower profile than the current systems, has never been tested in this scenario. OBJECTIVES: To evaluate the late effectiveness of the Sparrow® drug-eluting stent, regarding in-stent late lumen loss (LLL). METHODS: Patients with ischemia, symptomatic or documented, were submitted to PCA in vessels with reference diameter < 2.75 mm, divided into two groups regarding Sparrow® stent type: group 1: Sparrow® drug-eluting stent (DES), group 2: Sparrow® bare metal stent (BMS). Clinical follow-up duration was 12 months. Evaluation using quantitative coronary angiography (QCA) was performed immediately and at 8 months. A decrease of over 65% of in-stent LLL with DES was estimated to calculate sample size. IBM® SPSS software, release 19 (Chicago, Illinois, USA) was used for the statistical analysis. RESULTS: A total of 24 patients were randomized, 12 in each group. The DES and BMS groups were similar in age (63.25 ± 10.01 vs. 64.58 ± 11.54, p = 0.765), male gender (58.3% vs. 33.3%, p = 0.412), risk factors and all angiographs aspects. Immediate results were satisfactory in both groups. At 8 months in-stent late lumen loss was significantly lower in DES than in BMS group (DES vs. BMS 0.25 ± 0.16 0.97 ± 0.76, p = 0.008). CONCLUSION: In small-vessel PCA, the Sparrow® DES determined significant reduction in in-stent LLL, when compared to Sparrow® BMS.
Asunto(s)
Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Reestenosis Coronaria/prevención & control , Vasos Coronarios/fisiopatología , Stents Liberadores de Fármacos , Miniaturización , Angioplastia Coronaria con Balón , Estenosis Coronaria , Stents , Sirolimus/administración & dosificación , Resultado del TratamientoRESUMEN
INTRODUCTION: Vascular response at edges of drug-eluting stents is still not well established, particularly in diabetic patients who are prone to aggressive atherosclerosis progression. Recently, Biolimus and Zotarolimus have demonstrated potent antiproliferative effects. OBJECTIVE: To compare the vascular responses at edges of sirolimus analogous-eluting stents in patients with and without diabetes, using intravascular ultrasound (IVUS). METHODS: 306 edges were analyzed in 153 patients treated with drug-eluting stents and divided in: diabetics (122 edges) and nondiabetics (166 edges). IVUS was performed postintervention and at 6-month follow-up and included 5 mm distal and proximal to the stented segment. Vessel, lumen, and plaque volumes were calculated. Volume variation (follow-up minus basal) was also calculated. Edge restenosis was defined as obstruction >50%. RESULTS: Baseline characteristics were similar between groups. In both groups the entire lesion length was covered (stent length/lesion length ratio was 1.5 for both groups). There were no differences in edge volumes and restenosis rate between the groups. Among diabetics, there was no significant volume variation. However, in nondiabetic patients there was significant increase in vessel volume in proximal (from 67.1 +/- 22 mm(3) to 72.2 +/- 25 mm(3): P = 0.02) and distal (from 54.4 +/- 22 mm(3) to 59.8 +/- 22 mm(3): P = 0.001) edges. CONCLUSION: Nondiabetic patients showed a significant positive vascular remodeling in proximal and distal edges of sirolimus analogous-eluting stent. This vascular mechanism was not observed in diabetic patients. Although different vascular responses were observed, restenosis rates were equivalent between the 2 groups at 6-month follow-up.
Asunto(s)
Fármacos Cardiovasculares/administración & dosificación , Reestenosis Coronaria/diagnóstico por imagen , Estenosis Coronaria/terapia , Angiopatías Diabéticas/terapia , Stents Liberadores de Fármacos , Sirolimus/análogos & derivados , Sirolimus/administración & dosificación , Ultrasonografía Intervencional , Anciano , Estudios de Casos y Controles , Angiografía Coronaria , Estenosis Coronaria/diagnóstico por imagen , Angiopatías Diabéticas/diagnóstico por imagen , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Diseño de Prótesis , Factores de Tiempo , Resultado del TratamientoRESUMEN
INTRODUCTION AND OBJECTIVES: C-reactive protein (CRP) is an inflammatory marker that predicts cardiac events in patients with coronary syndromes. However, data on the relationship between the CRP level and in-stent restenosis are contradictory. The objective of this study was to investigate the relationship between the basal CRP level and the neointimal hyperplasia volume measured by intracoronary ultrasound 4 months after implantation of a zotarolimus-eluting stent. METHODS: The study included 40 consecutive patients who underwent zotarolimus-eluting stent implantation. Patients were divided into quartiles according to their preprocedural CRP level. Intracoronary ultrasound was performed after stent implantation and at 4 months, and the neointimal hyperplasia volume was determined using Simpson's rule. Correlation and linear regression analyses were used to evaluate the relationships between variables. Multivariate analysis was used to identify variables that were independently related to neointimal hyperplasia volume. RESULTS: The patients' mean age was 58 (8) years, 55% were male, and 40% had diabetes mellitus. There was no difference in baseline characteristics between the quartiles. The hyperplasia volumes were 4.8 (4.2) microl and 15.8 (10.0) microl in the first and fourth quartiles, respectively (P< .001). There was a significant positive correlation between the CRP level and neointimal hyperplasia volume (r = 0.64, P=.0001). The CRP level, the postimplantation lumen volume, and the final deployment pressure were all independent predictors of neointimal hyperplasia. CONCLUSIONS: In this study, an independent correlation was observed between the CRP level before zotarolimus-eluting stent implantation and the neointimal hyperplasia volume at 4-month follow-up.
Asunto(s)
Proteína C-Reactiva/análisis , Vasos Coronarios/diagnóstico por imagen , Vasos Coronarios/patología , Sistemas de Liberación de Medicamentos , Imagenología Tridimensional , Sirolimus/análogos & derivados , Stents , Túnica Íntima/patología , Ultrasonografía Intervencional , Femenino , Humanos , Hiperplasia , Masculino , Persona de Mediana Edad , Sirolimus/administración & dosificaciónRESUMEN
Introdução: A eficácia e a segurança do stent farmacológico (SF) de segunda geração liberador de everolimus XienceTM V (Abbott Vascular, Santa Clara, Estados Unidos) já foram estabelecidas no tratamento de pacientes selecionados com lesões coronárias. No entanto, o impacto do stent Xience TM V em população da prática clínica com lesóes complexas ainda não está totalmente definido. Métodos: O Registro BRAVO foi um estudo prospectivo, não-randomizado, multicêntrico, que avaliou os resultados clínicos tardios de pacientes minimamente selecionados tratados com o SF Xience TM V na prática diária brasileira. No total, foram incluídos 535 pacientes em 25 centros clínicos entre setembro de 2008 e setembro de 2010. Eventos cardíacos adversos maiores (ECAM) foram definidos como morte cardíaca, infarto agudo do miocárdio (IAM) e revascularização do vaso-alvo (RVA). Resultados: A média de idade dos pacientes era de 62,7 + - 11,1 anos 40 dos quais tinham diabetes, 24,9 apresentavam IAM prévio e 41,9 apresentaram-se com síndrome coronária aguda. Cerca de dois terços dos pacientes tinham lesões tipo B2/C e 46,1 trataram a artéria descendente anterior. Implante de múltiplos stents ocorreu em 13,8 dos casos, e o sucesso angiográfico foi > 99. Na fase intra-hospitalar, a taxa de IAM periprocedimento foi de 1,9. Já no seguimento de 6 meses, as taxas cumulativas de óbito cardíaco, IAM e RVA foram de 1,1, 2,2 e 1,3, respectivamente)taxa de ECAM de 4,3). Com relação à trombose de stent (definida de acordo com os critérios do Academic Research Consortium - ARC), foram reportados 4 casos até 6 meses...