Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros

Bases de datos
Tipo de estudio
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Radiol Case Rep ; 19(3): 855-858, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38188949

RESUMEN

Coronavirus disease 2019 (COVID-19) causes a systemic inflammatory response and a temporary immunosuppression of hosts. Several reports have showed that reactivation of herpes simplex virus type 1 (HSV-1) is strongly associated with COVID-19. We present a case of a 66-year-old female, who developed HSV-1 encephalitis, showing impaired consciousness and typical MRI findings such as hyperintense lesions in the temporal lobe, insular cortices, bilateral medial frontal lobe on diffusion-weighted imaging, 7 days after the onset of COVID-19 symptoms. The number of cases of encephalitis in patients with COVID-19 is increasing. However, there has been limited reports of HSV-1 encephalitis following COVID-19, especially for cases with an interval of 7 days or less from the onset of COVID-19 symptoms to the onset of HSV-1 encephalitis. Our case highlights the importance of considering HSV-1 encephalitis in the differential when managing a patient with COVID-19-associated neurologic complications, even if it is in the early stages of COVID-19.

2.
J Rural Med ; 14(1): 103-109, 2019 May.
Artículo en Inglés | MEDLINE | ID: mdl-31191773

RESUMEN

Objective: The average glandular dose (AGD) is used to evaluate the radiation dosage in mammography. Dance et al. (2000) presented a computation formula to estimate the AGD based on several coefficient factors, such as compressed breast thickness, breast tissue composition, and half-value layers (HVLs). The objective of this study was to improve the preciseness of AGD estimation. Materials and Methods: We interpolated the coefficients developed by Dance et al. to generate an approximation formulae and reference datasets with higher granularity and breast thickness (2-6 cm) relevant to a Japanese population. Results: The results from this study indicate that the incorporation of HVLs and breast thickness required in mammography densitometry leads to an advancement in the current method for estimating the average glandular dose. Conclusions: We expect that these interpolated values will serve as a reference for other researchers and allow for a more accurate, detailed, and individualized AGD estimation.

3.
4.
Radiol Res Pract ; 2018: 6192594, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30643646

RESUMEN

We aimed to investigate the effects of mammary gland density and average glandular dose (AGD) on contrast-to-noise ratio (CNR) of breast-equivalent phantoms with different mammary gland/fat tissue ratios. Full-field digital-mammography breast X-rays were performed on breast-equivalent phantoms with three different mammary gland/fat tissue ratios (Phantom A [30/70], Phantom B [50/50], and Phantom C [70/30]) and seven thicknesses ranging from 10 mm to 70 mm. The prediction formula for the CNR was calculated by multivariate analysis and the effects of the various parameters on CNR were evaluated using a multiple regression analysis model. Higher CNR values were obtained with lower mammary gland/fat tissue ratios and lower phantom thicknesses. Variation in CNR among the three breast models was low (coefficient of variation, 3.4-8.7%) at lower phantom thicknesses (10-30 mm) and high (coefficient of variation, 10.5-16.8%) at higher phantom thickness (50-70 mm). CNR showed a strong negative correlation (r = -0.8989) with AGD across all three mammary gland ratios. A predictive formula for CNR using AGD and mammary gland density was developed. CNR can be predicted with high precision using AGD and mammary gland density. The predicted CNR could be used to measure the diagnostic reliability of mammography in breast cancer.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA