Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Bases de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Klin Lab Diagn ; 67(8): 433-439, 2022 Aug 15.
Artículo en Inglés | MEDLINE | ID: mdl-36095078

RESUMEN

Subchondral remodeling is an important pathogenic mechanism in primary gonarthrosis progress. The role of altered metabolism of osseous tissue in early signs of articular pathology remains vague, and the informative value of biochemical markers is discussible. Our research involved 103 patients (64 women and 39 men) with 0-I gonarthrosis stages and 103 healthy individuals (72 women and 28 men) of 36 to 50 years old. We measured osteocalcin, pyridinoline, type I collagen telopeptides, vitamin B metabolites, cartilage oligomeric matrix protein concentrations, determined the activity of bone alkaline phosphatase, and diagnostic significance of the markers with the ROC curve. We found the increase (p<0.0001) in bone alkaline phosphatase, type I collagen telopeptides, cartilage oligomeric matrix protein concentrations as well as osteocalcin (p<0.0002) in 0-I gonarthrosis stages as compared to the controls. The ROC curve featured 98.1 and 79.6 percent sensitivity and specificity of type I collagen telopeptides; 80.6 and 52.4 percent of osteocalcin; 99.0 and 78.6 percent of pyridinoline, respectively. These findings suggest the significant role of subchondral remodeling in the pathogenesis of early gonarthrosis stages. Pyridinoline and type I collagen telopeptides are the most informative osseous markers detectable in the serum of patients with early gonarthrosis.


Asunto(s)
Colágeno Tipo I , Osteoartritis de la Rodilla , Adulto , Fosfatasa Alcalina , Biomarcadores , Regeneración Ósea , Proteína de la Matriz Oligomérica del Cartílago , Femenino , Humanos , Masculino , Persona de Mediana Edad , Osteoartritis de la Rodilla/diagnóstico , Osteocalcina
2.
Phys Rev Lett ; 109(7): 070801, 2012 Aug 17.
Artículo en Inglés | MEDLINE | ID: mdl-23006352

RESUMEN

We report the measurement of the time of flight of ∼17 GeV ν(µ) on the CNGS baseline (732 km) with the Large Volume Detector (LVD) at the Gran Sasso Laboratory. The CERN-SPS accelerator has been operated from May 10th to May 24th 2012, with a tightly bunched-beam structure to allow the velocity of neutrinos to be accurately measured on an event-by-event basis. LVD has detected 48 neutrino events, associated with the beam, with a high absolute time accuracy. These events allow us to establish the following limit on the difference between the neutrino speed and the light velocity: -3.8 × 10(-6) < (v(ν)-c)/c < 3.1 × 10(-6) (at 99% C.L.). This value is an order of magnitude lower than previous direct measurements.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA