1.
J Cardiovasc Electrophysiol ; 33(7): 1587-1589, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-35557022

RESUMEN

INTRODUCTION: A new dielectric-based method (KODEX-EPD mapping system, EPD Solutions, a Philips company) for measuring tissue thickness at the catheter-tissue interface has recently been developed. We reported preliminarydata on real-time catheter-based measuring myocardial wall thickness in vivo, during typical atrial flutter radio frequency ablation. METHODS AND RESULTS: The study population consisted of 12 consecutive patients, suffering from symptomatic paroxysmal or persistent cavo-tricuspid isthmus dependent, counter clockwise and clockwise AFL, under going a first catheter ablation between April 2021 and November 2021. The new KODEX-EPD function, Wall Viever, was used to calculate atrialwall thickness. The atrial wall thickness was significantly higher closeto the tricuspid annulus than close to the inferior vena cava (3.6 ± 0.5 mm vs 2.4 ± 0.3 mm, p < .001) and a trend towards a progressive decrease of atrial wall thickness was observed moving the mapping catheter from the tricuspidvalve to the inferior vena cava. CONCLUSIONS: Thenew KODEX-EPD function, Wall Viever, allowed us to assess atrial wall thickness during atrial flutter radio frequency ablation.


Asunto(s)
Aleteo Atrial , Ablación por Catéter , Aleteo Atrial/diagnóstico por imagen , Aleteo Atrial/cirugía , Ablación por Catéter/efectos adversos , Atrios Cardíacos , Humanos , Vena Cava Inferior/diagnóstico por imagen , Vena Cava Inferior/cirugía
2.
Heart Vessels ; 37(1): 115-120, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-34240266

RESUMEN

Pulmonary vein (PV) isolation using cryoballoon (CB) catheter is generally characterized by a high radiation and contrast media exposure. A new dielectric imaging system (KODEX-EPD imaging system) allows pulmonary vein (PV) occlusion assessment without dye use. The purpose of this study was to verify the feasibility of reducing the radiation and dye use during CB ablation in patients with atrial fibrillation (AF) using the new dielectric imaging system. In a retrospective, single center study, we enrolled 34 consecutive patients with paroxysmal AF divided in two groups: 17 patients in Conventional Group underwent the procedure under fluoroscopy guidance before the new system introduction, while 17 patient in KODEX-EPD Group underwent the procedure under fluoroscopy and KODEX-EPD imaging system guidance. There were no differences in any clinical and anatomical characteristics between the two study groups. Overall procedure time was comparable between the two groups (69 [IQR 63-98] min in Conventional Group vs. 65 [IQR 58-74] min in KODEX-EPD Group, p = 0.16), while fluoroscopy time (8 [IQR 5-9] min vs. 11 [IQR 9-12] min, p = 0.014) and dye use (35 [IQR 28-45] ml vs. 70 [IQR 57-83] ml, p < 0.001) were significantly lower in the KODEX-EPD Group. No 30-day complications were observed. At 12-month follow-up 7/37 (19%) patients had an atrial arrhythmias recurrence, without any difference between the two study groups (17.6% vs. 23.5%, p = 0.68). The use of a new dielectric imaging system allowed a significantly reduction in radiation exposure and dye use during CB ablation in patients with AF.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Criocirugía , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Medios de Contraste , Fluoroscopía , Humanos , Venas Pulmonares/diagnóstico por imagen , Venas Pulmonares/cirugía , Recurrencia , Estudios Retrospectivos , Resultado del Tratamiento
3.
Pacing Clin Electrophysiol ; 44(10): 1717-1723, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-34498748

RESUMEN

INTRODUCTION: A very high-power short-duration (vHPSD) strategy of radiofrequency (RF) ablation aims to minimize conductive heating and increase resistive heating. This study aimed to clarify the contribution of contact force (CF) and temperature and their interrelationship in making an adequate lesion with the vHPSD catheter. METHODS: We enrolled 46 consecutive patients undergoing first catheter ablation for atrial fibrillation (AF). The vHPSD ablation was performed applying 90 W, for 4 s, with an irrigation of 8 ml/min. During an application, an impedance drop (ID) ≥10 Ω was regarded as an adequate lesion formation. RESULTS: The mean procedural time was 95 ± 15 min. First-pass isolation was reached in 89% of patients and at the end of the procedure all pulmonary veins were isolated. No steam pop nor procedural complication occurred. A total of 3829 qualified RF points were analyzed and the median values of ID, CF and maximum temperature were respectively 10.6 (IQR 8.6-13.1) Ohm, 9 (5.8-13.8) g, 46.8 (44.1-49.8) °C. The mean ID significantly increased in parallel with the increasing CF as well as with the increasing maximum temperature. In the multivariable analysis only the CF and the maximum temperature were independent predictors of ID. From receiver operating characteristic curve analysis, a CF of 8 g and a maximum temperature of 47°C are the optimal cutoff discriminatory value for adequate lesion formation. CONCLUSIONS: The vHPSD ablation is highly effective and safe. The CF and the maximum temperature are independent predictors of adequate lesion formation assessed by means of ID.


Asunto(s)
Fibrilación Atrial/cirugía , Venas Pulmonares/cirugía , Ablación por Radiofrecuencia/métodos , Femenino , Calor , Humanos , Masculino , Persona de Mediana Edad , Tempo Operativo , Irrigación Terapéutica
4.
J Interv Card Electrophysiol ; 66(9): 2011-2020, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-36964415

RESUMEN

BACKGROUND: Contact force (CF)-sensing catheters have not proved superior to standard catheters in the ablation of premature ventricular contractions (PVCs) from the right and left ventricular outflow tract (RVOT, LVOT). In this context, the utility of measuring local impedance (LI) is not known. We aimed to ascertain whether the use of a catheter combining LI and CF information was associated with superior outcomes in comparison with other catheter technologies. METHODS: We compared three groups of 40 propensity-matched patients with PVCs from the OTs, ablated by means of different catheter technologies: a CF-plus LI-featured catheter, an LI-featured catheter, and a standard irrigated catheter. RESULTS: The CF + LI group displayed a significantly lower risk of PVC recurrence than the standard ablation group (HR, 0.22; 95%CI, 0.07-0.71; p = 0.01). In the CF + LI group, LI drop and RF time were the only predictors of successful lesions (OR = 1.19, CI: 1.13-1.26, p < 0.001; OR = 1.06 CI: 1.01-1.07, p = 0.044, respectively). In the coronary cusps, unlike the RVOT/LVOT region, CF was not associated with LI drop (p = 0.48), and RF duration showed a linear relationship with LI drop (p < 0.001). CONCLUSIONS: The use of ablation catheters that combine CF and LI information is associated with increased success in the RF ablation of PVCs from the OTs. LI drop is the most important predictor of effective lesions, but its behavior depends on the ablation site: in the coronary cusps, unlike the RVOT/LVOT region, longer RF application times are needed in order to achieve LI drops associated with successful outcomes. REGISTRY AND REGISTRATION NO. OF THE STUDY/TRIAL: NCT03793998.


Asunto(s)
Ablación por Catéter , Complejos Prematuros Ventriculares , Humanos , Catéteres , Impedancia Eléctrica , Complejos Prematuros Ventriculares/cirugía
5.
J Interv Card Electrophysiol ; 65(1): 97-102, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-35378611

RESUMEN

BACKGROUND: A very high-power short-duration (vHPSD) strategy of radiofrequency (RF) ablation aims to minimize conductive heating and increase resistive heating. We evaluated the feasibility, efficacy and safety of the vHPSD ablation of the cavotricuspid isthmus (CTI) in patients presenting with typical atrial flutter (AFL). METHODS: This prospective non-randomized study enrolled 28 consecutive patients (FAST Group) with typical AFL undergoing CTI ablation. The vHPSD ablation was performed applying 90 W, for 4 s, with an irrigation of 8 ml/min. Thirty consecutive patients who, previously, underwent CTI ablation by means of a contact force surrounding flow catheter guided by ablation index (500) served as control group (AI Group). RESULTS: In the FAST Group, the mean CTI length was 29 ± 6 mm, and the mean number of RF tags was 20 ± 9. The CTI bidirectional "first pass" block was reached in 25 (89%) patients. There were no major procedural complications. After a mean follow-up of 6 ± 2 months, one (3.5%) patient had arrhythmia recurrence. The vHPSD ablation was as effective as AI-guided ablation in achieving acute CTI block (rate of first pass 89% vs 93%, p = 0.59), with a shorter RF time (88 ± 40 s vs 492 ± 269 s, p < 0.001) and similar procedure (30 ± 4 min vs 34 ± 10 min, p = 0.5) and fluoroscopy time (103 ± 29 vs 108 ± 52 s, p = 0.7). At 8 months, the freedom from AFL recurrence was 96% in the FAST group and 97% in the AI group. CONCLUSIONS: Our preliminary data show that the vHPSD ablation represents an effective and safe ablation strategy to achieve bidirectional block for the treatment of typical AFL.


Asunto(s)
Aleteo Atrial , Ablación por Catéter , Aleteo Atrial/cirugía , Humanos , Estudios Prospectivos , Temperatura , Resultado del Tratamiento
6.
J Cardiovasc Med (Hagerstown) ; 23(6): 353-358, 2022 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-34580253

RESUMEN

Interventional cardiologists are significantly exposed to X- rays and no dose of radiation may be considered well tolerated or harmless. Leaded aprons protect the trunk and the thyroid gland, leaded glasses protect the eyes. The operator's legs, arms, neck and head are, instead, not fully protected. In fact, the operator's brain remains the closest part to the primary X-ray beam and scatter in most interventional procedures and specifically the physician's front head is the most exposed region during device implantation performed at the patient's side. After the initial description of cases of brain and neck tumours, additional reports on head and neck malignancies have been published. Although a direct link between operator radiation exposure and brain cancer has not been established, these reports have heightened awareness of a potential association. The use of lead-based cranial dedicated shields may help reduce operator exposure but upward scattered radiation, weight and poor tolerability have raised concerns and hindered widespread acceptance. The purpose of this review is to describe current knowledge on occupational X-ray exposure of interventional cardiologists, with a special focus on the potential risks for the head and neck and efficacy of available protection devices.


Asunto(s)
Cardiología , Exposición a la Radiación , Protección Radiológica , Humanos , Dosis de Radiación , Exposición a la Radiación/efectos adversos , Exposición a la Radiación/prevención & control , Protección Radiológica/métodos , Radiografía Intervencional/efectos adversos , Rayos X
7.
J Cardiovasc Med (Hagerstown) ; 22(10): 751-758, 2021 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-34009182

RESUMEN

AIMS: Radiation use in medicine has significantly increased over the last decade, and cardiologists are among the specialists most responsible for X-ray exposure. The present study investigates a broad range of aspects, from specific European Union directives to general practical principles, related to radiation management among a national cohort of cardiologists. METHODS AND RESULTS: A voluntary 31-question survey was run on the Italian Arrhythmology and Pacing Society (AIAC) website. From June 2019 to January 2020, 125 cardiologists, routinely performing interventional electrophysiology, participated in the survey. Eighty-seven (70.2%) participants are aware of the recent European Directive (Euratom 2013/59), although only 35 (28.2%) declare to have read the document in detail. Ninety-six (77.4%) participants register the dose delivered to the patient in each procedure, in 66.1% of the cases both as fluoroscopy time and dose area product. Years of exposition (P = 0.009) and working in centers performing pediatric procedures (P = 0.021) related to greater degree of X-ray equipment optimization. The majority of participants (72, 58.1%) did not recently attend radioprotection courses. The latter is related to increased awareness of techniques to reduce radiation exposure (96% vs. 81%, P = 0.022), registration of the delivered dose in each procedure (92% vs. 67%, P = 0.009), and X-ray equipment optimization (50% vs. 36%, P = 0.006). CONCLUSION: Italian interventional cardiologists show an acceptable level of radiation awareness and knowledge of updated European directives. However, there is clear space for improvement. Comparison to other health professionals, both at national and international levels, is needed to pursue proper X-ray management and protect public health.


Asunto(s)
Técnicas Electrofisiológicas Cardíacas , Exposición Profesional , Exposición a la Radiación , Administración de la Seguridad , Electrofisiología Cardíaca/normas , Cardiología/normas , Técnicas Electrofisiológicas Cardíacas/efectos adversos , Técnicas Electrofisiológicas Cardíacas/métodos , Técnicas Electrofisiológicas Cardíacas/normas , Conocimientos, Actitudes y Práctica en Salud , Humanos , Italia , Exposición Profesional/análisis , Exposición Profesional/prevención & control , Exposición Profesional/estadística & datos numéricos , Exposición a la Radiación/análisis , Exposición a la Radiación/prevención & control , Exposición a la Radiación/estadística & datos numéricos , Administración de la Seguridad/métodos , Administración de la Seguridad/organización & administración , Encuestas y Cuestionarios
8.
J Interv Card Electrophysiol ; 54(1): 9-15, 2019 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-30058055

RESUMEN

PURPOSE: Reconnection of pulmonary veins (PVs) remains common following radiofrequency catheter ablation for atrial fibrillation (AF). Ablation Index (AI) is a novel ablation quality marker that incorporates stability, contact force (CF), time, and power in a weighted formula. Its use seems to improve lesion durability. This is a prospective, single-arm registry to investigate on the safety and mid-term efficacy of AF ablation guided by the AI. METHODS: One hundred fifty-six consecutive patients (mean age 58 ± 10 years, 49% males, 44% with structural heart disease) referred for paroxysmal (124) or persistent (32) AF underwent antral PV isolation using a surround flow CF-sensing catheter guided by the AI. Radiofrequency was delivered targeting interlesion distance ≤ 6 mm and Ablation Index of 330-350 at posterior wall and 400-450 at anterior wall. RESULTS: Mean overall procedure time was 95 ± 30 min with a mean fluoroscopy time of 5 ± 6 min. Mean ablation time was 26 ± 10 min, 627/628 targeted PV were isolated. One pericardial effusion and two groin hematomas were reported; none required intervention. During a mean follow-up of 14 ± 6 months, 17 (10.8%) (9% paroxysmal AF vs 22% persistent AF, p = 0.09) patients had an atrial arrhythmia recurrence. CONCLUSIONS: PV ablation guided by AI resulted feasible, achieving a high rate of isolated PVs, with a low complication rate, and allowed a high single-procedure arrhythmia-free survival at 14 months.


Asunto(s)
Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Seguridad del Paciente , Venas Pulmonares/cirugía , Cirugía Asistida por Computador/métodos , Anciano , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/mortalidad , Ablación por Catéter/mortalidad , Distribución de Chi-Cuadrado , Femenino , Fluoroscopía/métodos , Humanos , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Tempo Operativo , Cuidados Posoperatorios/métodos , Pronóstico , Estudios Prospectivos , Sistema de Registros , Medición de Riesgo , Tasa de Supervivencia , Resultado del Tratamiento
12.
Clin Cardiol ; 39(11): 640-645, 2016 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-27468173

RESUMEN

BACKGROUND: Because 20% to 40% of patients undergoing cardiac resynchronization therapy (CRT) do not respond to it, identification of potential factors predicting response is a relevant research topic. HYPOTHESIS: There is a possible association between right ventricular function and response to CRT. METHODS: We analyzed 227 patients from the Cardiac Resynchronization Therapy Modular Registry (CRT-MORE) who received CRT according to current guidelines from March to December 2013. Response to therapy was defined as a decrease of ≥15% in left ventricular end-systolic volume (LVESV) at 6 months. RESULTS: The tricuspid annular plane systolic excursion (TAPSE) value that best predicted improvement in LVESV (sensitivity 68%, specificity 54%) was 17 mm. Stratifying patients according to TAPSE, LVESV decreased ≥15% in 78% of patients with TAPSE >17 mm (vs 59% in patients with TAPSE ≤17 mm; P = 0.006). At multivariate analysis, TAPSE >17 mm was independently associated with LVESV improvement (odds ratio: 1.97, 95% confidence interval: 1.03-3.80, P < 0.05), together with ischemic etiology (odds ratio: 0.39, 95% confidence interval: 0.20-0.75, P < 0.01). These results were confirmed for New York Heart Association class III to IV patients (79% echocardiographic response rate in patients with TAPSE >17 mm vs 55% in patients with TAPSE <17 mm; P = 0.012). CONCLUSIONS: Baseline signs of right ventricular dysfunction suggest possible remodeling after CRT. A TAPSE value of 17 mm was identified as a good cutoff for predicting a better response to CRT in patients with both mildly symptomatic and severe heart failure.


Asunto(s)
Terapia de Resincronización Cardíaca , Insuficiencia Cardíaca/terapia , Disfunción Ventricular Izquierda/terapia , Disfunción Ventricular Derecha/fisiopatología , Función Ventricular Derecha , Anciano , Anciano de 80 o más Años , Terapia de Resincronización Cardíaca/efectos adversos , Distribución de Chi-Cuadrado , Ecocardiografía , Femenino , Insuficiencia Cardíaca/diagnóstico por imagen , Insuficiencia Cardíaca/fisiopatología , Humanos , Italia , Modelos Logísticos , Masculino , Persona de Mediana Edad , Análisis Multivariante , Oportunidad Relativa , Sistema de Registros , Factores de Riesgo , Índice de Severidad de la Enfermedad , Volumen Sistólico , Factores de Tiempo , Resultado del Tratamiento , Válvula Tricúspide/fisiopatología , Disfunción Ventricular Izquierda/diagnóstico por imagen , Disfunción Ventricular Izquierda/fisiopatología , Disfunción Ventricular Derecha/diagnóstico por imagen , Función Ventricular Izquierda , Remodelación Ventricular
13.
Hellenic J Cardiol ; 56(3): 230-6, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-26021245

RESUMEN

INTRODUCTION: We evaluated the potential ability of the electrophysiological (EP) inducibility of ventricular arrhythmias to predict the likelihood of appropriate ICD intervention over the long-term in ischemic and nonischemic patients with current primary prevention indications for ICD implantation. METHODS: Between 2006 and 2008, 206 consecutive heart failure patients who were candidates for ICD implantation for the primary prevention of sudden cardiac death according to standard indications underwent EP testing, usually on ICD implantation. RESULTS: On EP testing, 15 (7%) patients had inducible monomorphic ventricular tachycardia (VT) and 14 (7%) ventricular fibrillation (VF). Over 24 months, 64 (31%) patients received appropriate ICD therapies: 51 (25%) for VT and 16 (8%) for VF. The time to the first appropriate ICD therapy trended to be shorter in the group of patients who were inducible on EP testing (p=0.072). Among patients receiving appropriate therapies, the median number of arrhythmic episodes was 2, and the proportion of patients with 2 treated arrhythmic episodes was higher in the group of inducible patients (34% versus 14%, p=0.005). On multivariate analysis, inducibility proved to be an independent predictor of frequent (2) arrhythmic episodes, as did a history of coronary artery bypass grafting. Moreover, patients with 2 treated arrhythmic episodes showed higher mortality (log-rank test, p=0.042). CONCLUSION: Patients with inducibility of VT or VF are more likely to experience frequent appropriate ICD therapies during follow up.


Asunto(s)
Desfibriladores Implantables , Técnicas Electrofisiológicas Cardíacas/métodos , Taquicardia Ventricular/terapia , Fibrilación Ventricular/terapia , Anciano , Cardiomiopatía Dilatada/terapia , Muerte Súbita Cardíaca/prevención & control , Electrocardiografía/métodos , Femenino , Estudios de Seguimiento , Insuficiencia Cardíaca/fisiopatología , Insuficiencia Cardíaca/terapia , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Estudios Prospectivos , Taquicardia Ventricular/fisiopatología , Fibrilación Ventricular/fisiopatología
14.
Expert Rev Cardiovasc Ther ; 11(7): 837-42, 2013 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-23895027

RESUMEN

Antiarrhythmic drugs (AADs) are often used after ablation for atrial fibrillation (AF); the drugs employed vary, but most common are the drugs that were unsuccessful prior to ablation since it seems that the efficacy of AADs might substantially increase after catheter ablation of AF. AADs reduce early recurrences of atrial tachyarrhythmias after AF catheter ablation, whereas they did not prevent arrhythmia recurrences occurring later. Several upstream therapies (angiotensin-converting enzyme inhibitors, angiotensin receptor blockers, statins, corticosteroids and colchicine) have been tested with conflicting results. To date, there is no sufficient evidence to support the use of any upstream therapy after AF catheter ablation. Larger registries and controlled clinical trials in well-defined patient groups and with well-defined outcome parameters are required to further elucidate the role of AADs after AF ablation.


Asunto(s)
Antiarrítmicos/uso terapéutico , Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Arritmias Cardíacas/prevención & control , Ensayos Clínicos como Asunto , Humanos , Prevención Secundaria
15.
Circ Heart Fail ; 6(6): 1259-67, 2013 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-24029661

RESUMEN

BACKGROUND: Impaired angiogenesis in the post-myocardial infarction heart contributes to the progression to heart failure. The inhibition of vascular endothelial growth factor (VEGF) signaling has been shown to be crucial for the transition from compensatory hypertrophy to cardiac failure. Importantly, ß-adrenergic receptor blocker therapy has been also shown to improve myocardial perfusion by enhancing neoangiogenesis in the failing heart. METHODS AND RESULTS: Eight weeks from surgically induced myocardial infarction, heart failure rats were randomized to receive bisoprolol (B) or vehicle. At the end of a 10-week treatment period, echocardiography revealed reduced cardiac diameters and improved cardiac function in B-treated compared with vehicle-treated rats. Moreover, B treatment was associated with increased cardiac angiogenesis and in vivo coronary perfusion and reduced cardiac fibrosis. Importantly, 2 weeks after B treatment was started, increased cardiac VEGF expression and Akt and endothelial NO synthase activation were observed by comparing B-treated with drug-untreated failing hearts. To test whether the proangiogenic effects of B act via activation of VEGF pathway, rats were intravenously injected with adenoviral vector encoding a decoy VEGF receptor (Ad-Flk) or a control adenovirus (Ad-C), at the start of the treatment with B. After 10 weeks, histological analysis revealed reduced capillary and coronary perfusion in B-treated plus Ad-Flk rats compared with B-treated plus Ad-C rats. Moreover, VEGF inhibition counteracted the positive effects of B on cardiac function and remodeling. CONCLUSIONS: ß-Blockade promotes cardiac angiogenesis in heart failure via activation of VEGF signaling pathway. ß-Blocker-induced enhancement of cardiac angiogenesis is essential for the favorable effects of this therapy on cardiac function and remodeling.


Asunto(s)
Antagonistas de Receptores Adrenérgicos beta 1/uso terapéutico , Bisoprolol/uso terapéutico , Circulación Coronaria/efectos de los fármacos , Insuficiencia Cardíaca/tratamiento farmacológico , Miocardio/patología , Factor A de Crecimiento Endotelial Vascular/antagonistas & inhibidores , Remodelación Ventricular/efectos de los fármacos , Animales , Modelos Animales de Enfermedad , Insuficiencia Cardíaca/metabolismo , Insuficiencia Cardíaca/patología , Masculino , Miocardio/metabolismo , Neovascularización Fisiológica/efectos de los fármacos , Ratas , Ratas Sprague-Dawley , Resultado del Tratamiento
16.
Trends Mol Med ; 18(8): 494-501, 2012 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-22818027

RESUMEN

The development of collateral circulation is an inherent compensatory mechanism to restore impaired blood perfusion following artery stenosis and/or occlusion. This process, termed arteriogenesis, is driven by inflammation and involves a complex remodeling of pre-existing conduit vessels running in parallel to the occluded artery. Recent studies have unveiled roles for different immune cell subsets as regulators of arteriogenesis, including natural killer (NK) cells, T helper 17 (Th17) cells, regulatory T lymphocytes (Tregs), and functional subsets of macrophages (e.g., M2 macrophages). This review summarizes recent findings and discusses future research needed to better define the time during which each cellular subset is active and reveal further critical regulatory switches.


Asunto(s)
Inmunidad Adaptativa , Vasos Sanguíneos/crecimiento & desarrollo , Vasos Sanguíneos/inmunología , Circulación Colateral , Inmunidad Innata , Neovascularización Patológica/inmunología , Animales , Humanos , Linfocitos/inmunología , Neovascularización Patológica/fisiopatología
17.
Cardiovasc Revasc Med ; 13(4): 219-23, 2012.
Artículo en Inglés | MEDLINE | ID: mdl-22632996

RESUMEN

BACKGROUND: The use of directional atherectomy (DA) for the treatment of calcified femoro-popliteal lesions seems to improve the acute procedural success, however without reducing the long term restenosis rate. Drug coated balloons (DCB) reduced restenosis rate in non heavy calcified lesions. Aim of this study was to demonstrate safety and efficacy of a combined endovascular approach using DA and DCB for the treatment of heavy calcified lesions of the femoro-popliteal tract. METHODS: From January 2010 to November 2010, 240 patients underwent PTA of the femoro-popliteal tract in our institution. Within this cohort a total of 30 patients had life limiting claudication (LLC) (n=18) and 12 a critical limb ischemia (CLI) with baseline Rutherford class 4.2±1.2 underwent PTA of heavy calcified lesions with intravascular ultrasound guided DA and DCB. All procedures have been performed using a distal protection device. Stent implantation was allowed only in case of flow limiting dissections or suboptimal result (residual stenosis>50%) by visual estimation. After the intervention patients were followed up to 12 months. RESULTS: Procedural and clinical success, was achieved in all cases. Bail-out stenting was necessary in only two (6.5%). At twelve month follow up median Rutherford class was 2.2±1.2, ABI was 0.8±0.1 and Limb salvage rate was 100%. Two minor, foot finger or forefoot amputations, were performed to reach complete wound healing and/or preserve deambulation. Duplex control was performed in all the cases (n=30). In three cases duplex scan showed a significant target lesion restenosis requiring a reintervention (TLR=10%) leading a total one-year secondary patency rate of 100%. All the three restenosed patients were insulin dependent diabetics and none of them were stented during the procedure. CONCLUSION: The data suggest that combined use of DA and DCB may represent a potential alternative strategy for the treatment of femoro-popliteal severely calcified lesions. These very promising data and the considered hypothesis have to be confirmed in a multicentre randomised trial.


Asunto(s)
Angioplastia de Balón , Aterectomía , Fármacos Cardiovasculares/administración & dosificación , Catéteres , Materiales Biocompatibles Revestidos , Arteria Femoral , Paclitaxel/administración & dosificación , Enfermedad Arterial Periférica/terapia , Arteria Poplítea , Calcificación Vascular/terapia , Anciano , Amputación Quirúrgica , Angioplastia de Balón/efectos adversos , Angioplastia de Balón/instrumentación , Angioplastia de Balón/métodos , Aterectomía/efectos adversos , Aterectomía/instrumentación , Aterectomía/métodos , Constricción Patológica , Enfermedad Crítica , Diseño de Equipo , Femenino , Arteria Femoral/diagnóstico por imagen , Arteria Femoral/fisiopatología , Humanos , Claudicación Intermitente/etiología , Claudicación Intermitente/terapia , Isquemia/etiología , Isquemia/terapia , Italia , Recuperación del Miembro , Masculino , Persona de Mediana Edad , Enfermedad Arterial Periférica/complicaciones , Enfermedad Arterial Periférica/diagnóstico , Arteria Poplítea/diagnóstico por imagen , Arteria Poplítea/fisiopatología , Radiografía , Recurrencia , Sistema de Registros , Índice de Severidad de la Enfermedad , Factores de Tiempo , Resultado del Tratamiento , Ultrasonografía Doppler Dúplex , Ultrasonografía Intervencional , Calcificación Vascular/complicaciones , Calcificación Vascular/diagnóstico , Calcificación Vascular/fisiopatología , Grado de Desobstrucción Vascular
18.
J Interv Card Electrophysiol ; 35(3): 331-6; discussion 336, 2012 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-22890483

RESUMEN

PURPOSE: Patients with permanent atrial fibrillation (AF) who undergo cardiac resynchronization therapy (CRT) may spontaneously recover sinus rhythm during follow-up. We tested the feasibility and efficacy of electrical cardioversion attempted after 3 months of CRT in patients with permanent AF and measured the long-term maintenance of sinus rhythm. METHODS: Twenty-eight consecutive patients with permanent AF in whom CRT defibrillators had been implanted were scheduled for internal electrical cardioversion after 3 months (group A) and were compared with a control group of 27 patients (group B). RESULTS: In group A, 22 patients (79 %) were eligible for cardioversion; sinus rhythm was restored in 18 (82 %) of these, with no procedural complications. After 12 months, 16 patients (58 %) in group A were in sinus rhythm, compared with one group B patient who spontaneously recovered sinus rhythm (4 %, p < 0.001). On 12-month evaluation, ejection fraction had improved in both groups, but a reduction in left ventricular end-systolic volume was recorded only in group A patients (p = 0.018 versus baseline). CONCLUSIONS: In patients with permanent AF, the rhythm control strategy consisting of internal cardioversion, performed by means of the implanted cardioverter-defibrillator after 3 months of CRT, was associated with a high rate of sinus rhythm resumption on long-term follow-up and with a better echocardiographic response to CRT than that seen in patients treated according to a rate control strategy.


Asunto(s)
Fibrilación Atrial/fisiopatología , Fibrilación Atrial/terapia , Terapia de Resincronización Cardíaca/métodos , Cardioversión Eléctrica/métodos , Anciano , Estudios de Casos y Controles , Distribución de Chi-Cuadrado , Estudios de Factibilidad , Femenino , Humanos , Masculino , Factores de Riesgo , Estadísticas no Paramétricas , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA