Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 31
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
J Vasc Interv Radiol ; 34(11): 1958-1962.e1, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37451538

RESUMEN

During endovascular interventions, coaxial deployment of stents may be required to preserve luminal gain. This study characterized in vitro the effect on crush resistance and postcompression recovery when 316L stainless steel balloon-expandable (BE) and laser-cut nitinol self-expanding (SE) venous stents were deployed coaxially. Various stent configurations were parallel-plate compressed from a fully expanded state to 50% diameter reduction (Criterion, Model 42; MTS, Eden Prairie, Minnesota) in a 37 °C ± 1 water bath. Coaxial deployments of SE stent inside BE stent and BE stent inside SE stent demonstrated higher crush resistances compared with each stent individually or their mathematical summation (analysis of variance P < .0001; pairwise comparison P < .01). The configuration of SE stent inside BE stent showed higher postcompression luminal recovery at 48.7% compared with that of BE stent inside SE stent at 27.5% (P = .0001). Coaxial deployment of SE stent inside BE stent may improve crush resistance and luminal recovery after compression in the appropriate clinical context.


Asunto(s)
Aleaciones , Stents , Humanos , Minnesota , Diseño de Prótesis
2.
J Vasc Interv Radiol ; 33(3): 255-261.e2, 2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-34915165

RESUMEN

PURPOSE: To characterize an ovine endovascular radiofrequency (RF) ablation-based venous stenosis and thrombosis model for studying venous biomechanics and response to intervention. MATERIALS AND METHODS: Unilateral short-segment (n = 2) or long-segment (n = 6) iliac vein stenoses were created in 8 adult sheep using an endovenous RF ablation technique. Angiographic assessment was performed at baseline, immediately after venous stenosis creation, and after 2-week (n = 6) or 3-month (n = 2) survival. Stenosed iliac veins and the contralateral healthy controls were harvested for histological and biomechanical assessment. RESULTS: At follow-up, the short-segment RF ablation group showed stable stenosis without occlusion. The long-segment group showed complete venous occlusion/thrombosis with the formation of collateral veins. Stenosed veins showed significant wall thickening (0.28 vs 0.16 mm, P = .0175) and confluent collagen deposition compared with the healthy controls. Subacute nonadherent thrombi were apparent at 2 weeks, which were replaced by fibrous luminal obliteration with channels of recanalization at 3 months. Stenosed veins demonstrated increased longitudinal stiffness (448.5 ± 5.4 vs 314.6 ± 1.5 kPa, P < .0001) and decreased circumferential stiffness (140.8 ± 2.6 vs 246.0 ± 1.6 kPa, P < .0001) compared with the healthy controls. CONCLUSION: Endovenous RF ablation is a reliable technique for creating venous stenosis and thrombosis in a large animal model with histological and biomechanical attributes similar to those seen in humans. This platform can facilitate understanding of venous biomechanics and testing of venous-specific devices and interventions.


Asunto(s)
Ablación por Catéter , Enfermedades Vasculares , Insuficiencia Venosa , Trombosis de la Vena , Animales , Ablación por Catéter/métodos , Constricción Patológica/cirugía , Humanos , Vena Safena/cirugía , Ovinos , Resultado del Tratamiento , Enfermedades Vasculares/cirugía , Insuficiencia Venosa/cirugía , Trombosis de la Vena/cirugía
3.
J Vasc Interv Radiol ; 33(3): 262-267, 2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-35221046

RESUMEN

This study characterized the impact of vein wall biomechanics on inflow diameter and luminal flow during venous angioplasty and stent placement, using postthrombotic and healthy biomechanical properties from an ovine venous stenosis and thrombosis model. Finite element analysis demonstrated more pronounced inflow channel narrowing in the postthrombotic vein compared with the healthy control vein during angioplasty and stent placement (relative inflow diameter reduction of 42% versus 13%, P < .0001). Computational fluid dynamics modeling showed increased relative areas of low wall shear rate in the postthrombotic vein compared with the normal vein (0.46 vs 0.24 for shear rate < 50 s-1; 0.13 vs 0.07 for shear rate < 15 s-1; P < .05), with flow stagnation and recirculation. Since inflow narrowing and low wall shear rate are associated with in-stent restenosis and reintervention, these computational results based on experimentally obtained biomechanical values highlight the significance of postthrombotic venous properties in optimizing venous intervention outcomes.


Asunto(s)
Vena Ilíaca , Stents , Angioplastia , Animales , Fenómenos Biomecánicos , Simulación por Computador , Humanos , Ovinos , Resultado del Tratamiento
4.
J Vasc Interv Radiol ; 31(8): 1348-1356, 2020 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-32682711

RESUMEN

PURPOSE: To characterize the Poisson effect in response to angioplasty and stent placement in veins and identify potential implications for guiding future venous-specific device design. MATERIALS AND METHODS: In vivo angioplasty and stent placement were performed in 3 adult swine by using an established venous stenosis model. Iron particle endothelium labeling was performed for real-time fluoroscopic tracking of the vessel wall during intervention. A finite-element computational model of a vessel was created with ADINA software (version 9.5) with arterial and venous biomechanical properties obtained from the literature to compare the response to radial expansion. RESULTS: In vivo angioplasty and stent placement in a venous stenosis animal model with iron particle endothelium labeling demonstrated longitudinal foreshortening that correlated with distance from the center of the balloon (R2 = 0.87) as well as adjacent segment narrowing that correlated with the increase in diameter of the treated stenotic segment (R2 = 0.89). Finite-element computational analysis demonstrated increased Poisson effect in veins relative to arteries (linear regression coefficient slope comparison, arterial slope 0.033, R2 = 0.9789; venous slope 0.204, R2 = 0.9975; P < .0001) as a result of greater longitudinal Young modulus in veins compared with arteries. CONCLUSIONS: Clinically observed adjacent segment narrowing during venous angioplasty and stent placement is a result of the Poisson effect, with redistribution of radially applied force to the longitudinal direction. The Poisson effect is increased in veins relative to arteries as a result of unique venous biomechanical properties, which may be relevant to consider in the design of future venous interventional devices.


Asunto(s)
Angioplastia de Balón/instrumentación , Vena Ilíaca/fisiopatología , Modelos Cardiovasculares , Stents , Enfermedades Vasculares/terapia , Animales , Fenómenos Biomecánicos , Constricción Patológica , Modelos Animales de Enfermedad , Análisis de Elementos Finitos , Vena Ilíaca/diagnóstico por imagen , Sus scrofa , Enfermedades Vasculares/diagnóstico por imagen , Enfermedades Vasculares/fisiopatología
5.
AJR Am J Roentgenol ; 214(3): 671-678, 2020 03.
Artículo en Inglés | MEDLINE | ID: mdl-31743047

RESUMEN

OBJECTIVE. The evidence regarding pulmonary embolism treatment has greatly advanced over the past 10 years, particularly in patients with right ventricular dysfunction or hemodynamic instability. Treatment options include systemic anticoagulation, systemic thrombolysis, catheter-assisted thrombus removal (mechanical with or without catheter-directed thrombolysis), and surgical embolectomy. CONCLUSION. This article will review the data available for treatment options and summarize the evidence-based guidelines on treatment of intermediate- or high-risk pulmonary embolism.


Asunto(s)
Embolia Pulmonar/diagnóstico por imagen , Embolia Pulmonar/terapia , Diagnóstico Diferencial , Embolectomía , Medicina Basada en la Evidencia , Fibrinolíticos/uso terapéutico , Humanos , Guías de Práctica Clínica como Asunto , Medición de Riesgo , Terapia Trombolítica
6.
J Vasc Interv Radiol ; 30(3): 421-424, 2019 03.
Artículo en Inglés | MEDLINE | ID: mdl-30819486

RESUMEN

PURPOSE: To investigate the efficacy of palmar warming to induce radial artery vasodilation. MATERIALS AND METHODS: After informed consent was obtained, healthy volunteers (n = 45) were randomized 2:1 in palmar warming and control groups, respectively, for this prospective, randomized, single-blind clinical trial (NCT03620383). The palmar warming group was given a warm, commercially available, air-activated heat pack (Kobayashi Consumer Products LLC, Dalton, Georgia) to hold in the left hand for palmar warming. The control group was given a deactivated version of the same heat pack. Left radial artery cross-sectional area (CSA) measurements were obtained at baseline and in 5-minute intervals up to 20 minutes in both groups. Differences in the trends of changes in the radial artery CSA between palmar warming and control groups were examined with the age- and sex-adjusted repeated measure analysis of variance. Propensity score-matched treatment effect analysis was conducted to quantify the effect of heat on radial artery CSA. RESULTS: The palmar warming group and the control group were significantly different in terms of subject sex (males/females: 7/23 and 10/5, respectively; P = .005) and baseline CSA (2.5±0.2 mm2 vs 3.2±0.3 mm2, respectively; P = .014). Radial artery CSA showed an increasing trend over time in the palmar warming group compared to a stable trend over time in the control group (P < .0001). Propensity score-matched comparison showed a 43.9% increase (95% confidence interval: 34.1%-53.8%) in CSA in the palmar warming group compared to the control group (P < .0001). CONCLUSIONS: The palmar warming technique is effective at dilating the radial artery and may be a beneficial technique to facilitate transradial access.


Asunto(s)
Cateterismo Periférico/métodos , Mano/irrigación sanguínea , Hipertermia Inducida/métodos , Arteria Radial/fisiología , Vasodilatación , Adulto , Cateterismo Periférico/efectos adversos , Femenino , Voluntarios Sanos , Humanos , Hipertermia Inducida/efectos adversos , Masculino , Persona de Mediana Edad , Oregon , Estudios Prospectivos , Arteria Radial/diagnóstico por imagen , Método Simple Ciego , Ultrasonografía
7.
Circ J ; 83(2): 320-326, 2019 01 25.
Artículo en Inglés | MEDLINE | ID: mdl-30555125

RESUMEN

BACKGROUND: Inflammation and platelet activation have been shown to be involved in acute thromobogenicity following venous occlusive conditions. The aim of this study was to identify the association of baseline platelet count and neutrophil/lymphocyte ratio (NLR) with venous stent failure. Methods and Results: Patients who underwent technically successful iliocaval venous stent placement with available baseline complete blood count and follow-up stent patency data were selected (n=50). Stent failure was defined as >50% stenosis or occlusion at follow-up angiography, contrast-enhanced CT, MRI or duplex US. Median patient age was 49.5 years (range, 13-76 years), and 62% were female. Median follow-up time was 10.2 months (range, 0.1-76.4 months). Stent failure occurred in 13 patients (26%) after a median of 1.2 months (range, 1 day-76.4 months). On multivariable-adjusted Cox modeling, baseline platelets (HR, 2.28; P=0.004) and WBC count (HR, 2.03; P=0.013) were significantly associated with stent failure on follow-up; neutrophils (HR, 16.10; P=0.050); and NLR (HR, 12.19; P=0.050) had borderline significance. Compared with patients without stent failure, those with early, but not late, stent failure had higher baseline platelets (P=0.031) and neutrophils (P=0.025), and NLR (P=0.026). CONCLUSIONS: Baseline platelet count and NLR are associated with early but not late failure of iliocaval venous stents. This suggests different pathophysiologic mechanisms and a role for both platelet activation and inflammatory mechanisms in early rather than late stent thrombosis. Future research is needed to better explain this novel finding.


Asunto(s)
Recuento de Células Sanguíneas , Valor Predictivo de las Pruebas , Stents , Insuficiencia del Tratamiento , Adolescente , Adulto , Anciano , Constricción Patológica/etiología , Femenino , Estudios de Seguimiento , Humanos , Recuento de Linfocitos , Masculino , Persona de Mediana Edad , Neutrófilos/citología , Recuento de Plaquetas , Modelos de Riesgos Proporcionales , Trombosis/etiología , Factores de Tiempo , Adulto Joven
8.
J Vasc Interv Radiol ; 29(5): 632-635, 2018 05.
Artículo en Inglés | MEDLINE | ID: mdl-29685661

RESUMEN

An 83-year-old man with bilateral common iliac artery aneurysms (right, 3.0 cm; left, 2.7 cm), bilateral internal iliac artery aneurysms (right, 3.4 cm; left, 2.6 cm), and an abdominal aortic aneurysm (3.8 cm) was treated with an aortobi-iliac stent graft and bilateral iliac branch devices. The internal iliac components were extended into opposing posterior (left) and anterior (right) divisions of the internal iliac artery using stent grafts. Computed tomography angiography demonstrated that all aneurysms decreased or were stable in size with patent stent grafts at 1 month. The patient was asymptomatic without complications of pelvic ischemia at the last clinical follow-up at 6 months.


Asunto(s)
Implantación de Prótesis Vascular , Procedimientos Endovasculares/métodos , Aneurisma Ilíaco/cirugía , Pelvis/irrigación sanguínea , Stents , Anciano de 80 o más Años , Aneurisma de la Aorta Abdominal/cirugía , Angiografía por Tomografía Computarizada , Humanos , Aneurisma Ilíaco/diagnóstico por imagen , Arteria Ilíaca/cirugía , Hallazgos Incidentales , Masculino
9.
J Vasc Interv Radiol ; 29(7): 1023-1027, 2018 07.
Artículo en Inglés | MEDLINE | ID: mdl-29859663

RESUMEN

PURPOSE: To describe acute venographic changes of external iliac vein (EIV) after ipsilateral common iliac vein (CIV) stent placement. MATERIALS AND METHODS: Retrospective review was performed of 17 cases with placement of a single CIV stent. Central CIV stent diameter and minimal ipsilateral EIV diameter were measured on venogram; vein diameter was measured at the same 2 anatomic locations on venogram obtained before intervention. Relative CIV diameter increase was defined as the ratio of change in central CIV diameter after stent placement to CIV diameter before intervention. Relative EIV diameter reduction was defined as the ratio of change in diameter of EIV after stent deployment in CIV to EIV diameter before intervention. Diameters before and after intervention were compared using a 2-tailed, paired sample t test. Pearson coefficient was calculated for correlations. RESULTS: There was a significant reduction of EIV diameter after ipsilateral CIV stent placement compared with before stent placement (mean 9.3 mm ± 3.1 vs 11.9 mm ± 3.8; P < .01); mean decrease in EIV diameter was 21.7% ± 15.8. There was a correlation between relative CIV diameter increase and relative EIV diameter reduction (r = .8917). CONCLUSIONS: Significant venographic narrowing of the EIV occurs after placement of an adjacent CIV stent, and the degree of narrowing is associated with the relative increase in CIV diameter. These findings may be explained by the inherent anisotropic elasticity of veins. Further study is warranted to guide future venous interventions.


Asunto(s)
Procedimientos Endovasculares/instrumentación , Vena Ilíaca/diagnóstico por imagen , Flebografía , Stents , Trombosis de la Vena/terapia , Fenómenos Biomecánicos , Elasticidad , Humanos , Vena Ilíaca/fisiopatología , Síndrome Postrombótico/diagnóstico por imagen , Síndrome Postrombótico/etiología , Síndrome Postrombótico/fisiopatología , Valor Predictivo de las Pruebas , Estudios Retrospectivos , Resultado del Tratamiento , Trombosis de la Vena/complicaciones , Trombosis de la Vena/diagnóstico por imagen , Trombosis de la Vena/fisiopatología
10.
J Vasc Interv Radiol ; 28(10): 1348-1352, 2017 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-28941516

RESUMEN

The Indigo Mechanical Thrombectomy System (Penumbra, Inc, Alameda, California) was used to treat 6 patients with submassive pulmonary embolism (PE) and a contraindication to thrombolysis. Systolic pulmonary artery pressure (58.2 mm Hg vs 43.0 mm Hg, P < .05), right ventricular/left ventricular ratio (1.7 vs 1.1, P < .05), Miller index (15.0 vs 9.8, P < 0.01), and CT obstructive index (60.4% vs 47.0%, P < .01) were significantly reduced after mechanical thrombectomy. There were no procedural or periprocedural complications. Continuous aspiration mechanical thrombectomy is a feasible and promising technique for management of submassive PE to decrease thrombus burden and reduce right heart strain.


Asunto(s)
Embolia Pulmonar/cirugía , Trombectomía/instrumentación , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Resultado del Tratamiento
11.
J Vasc Interv Radiol ; 27(5): 730-4, 2016 May.
Artículo en Inglés | MEDLINE | ID: mdl-27106647

RESUMEN

Five consecutive cases in which the AngioVac aspiration cannula was used for the management of pulmonary embolism (PE) were retrospectively reviewed. Four cases (80%) presented with massive PE, and two (40%) were technically successful (reduction in Miller index ≥ 5). Four patients (80%) died at a mean of 7.3 days after the procedure, including one death related to right ventricular free wall perforation. Although the AngioVac aspiration cannula has shown clinical promise in a variety of clinical applications, early experience in the pulmonary arteries has shown limited success, and further study and careful patient selection are required.


Asunto(s)
Embolectomía/instrumentación , Arteria Pulmonar/diagnóstico por imagen , Embolia Pulmonar/terapia , Trombectomía/instrumentación , Dispositivos de Acceso Vascular , Adulto , Anciano , Anciano de 80 o más Años , Angiografía de Substracción Digital , Angiografía por Tomografía Computarizada , Embolectomía/métodos , Diseño de Equipo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Embolia Pulmonar/diagnóstico por imagen , Radiografía Intervencional , Estudios Retrospectivos , Succión , Trombectomía/métodos , Resultado del Tratamiento
12.
J Vasc Interv Radiol ; 27(10): 1584-91, 2016 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-27282218

RESUMEN

PURPOSE: To describe initial single-center experience with a thrombectomy device in managing right atrial and caval thrombi, tumors, and vegetations. MATERIALS AND METHODS: A retrospective analysis of AngioVac thrombectomy performed in 16 patients (mean age 53 y ± 13; 8 men, 8 women) between August 2013 and August 2015 was performed. Indications included right atrial mass/thrombus (6/16; 37.5%) and iliocaval thrombus (10/16; 62.5%). Procedural success was defined as aspiration of > 70% volume of atrial mass/thrombus or restoration of antegrade caval flow. RESULTS: Procedural success was achieved in 4/6 (67%) right atrial masses/thrombi and 10/10 (100%) caval thrombi. All patients (8/8; 100%) with caval thrombus presenting with swelling/edema had improvement or resolution of symptoms. There were no procedural or periprocedural mortalities; complications included one major (6.3%; intraprocedural pulmonary embolus) and one minor (6.3%; access site hematoma not requiring transfusion) complication. Of 16 patients, 14 (87.5%) survived to discharge at a mean of 10 days ± 8 (range, 1-23 d), and 12 patients (75%) were alive at last known follow-up at a mean of 385 days ± 267 (range, 63-730 d). At a mean of 194 days ± 177 (range, 41-372 d), 4/16 (25%) patients were dead; no death was related to AngioVac thrombectomy. At a mean of 66 days ± 21 (range, 49-90 d) after intervention, 3/14 (21.4%) cases with procedural success had local recurrence of mass/thrombus. CONCLUSIONS: AngioVac thrombectomy can be performed with high procedural success with clinical benefit in patients with right atrial and caval masses/thrombi.


Asunto(s)
Cardiopatías/terapia , Neoplasias Cardíacas/terapia , Trombectomía/instrumentación , Trombosis/terapia , Vena Cava Inferior , Vena Cava Superior , Trombosis de la Vena/terapia , Adulto , Anciano , Biopsia , Ecocardiografía Transesofágica , Diseño de Equipo , Femenino , Cardiopatías/diagnóstico por imagen , Cardiopatías/mortalidad , Neoplasias Cardíacas/diagnóstico por imagen , Neoplasias Cardíacas/mortalidad , Mortalidad Hospitalaria , Humanos , Los Angeles , Angiografía por Resonancia Magnética , Masculino , Persona de Mediana Edad , Flebografía/métodos , Estudios Retrospectivos , Factores de Riesgo , Trombectomía/efectos adversos , Trombectomía/mortalidad , Trombosis/diagnóstico por imagen , Trombosis/mortalidad , Factores de Tiempo , Tomografía Computarizada por Rayos X , Resultado del Tratamiento , Vena Cava Inferior/diagnóstico por imagen , Vena Cava Superior/diagnóstico por imagen , Trombosis de la Vena/diagnóstico por imagen , Trombosis de la Vena/mortalidad
13.
J Vasc Interv Radiol ; 27(9): 1380-1386, 2016 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-27566426

RESUMEN

PURPOSE: To investigate pulmonary microwave ablation metrics including ablation work, ablation resistance score, and involution. MATERIALS AND METHODS: Retrospective review was performed of 98 pulmonary tumor ablations using the NeuWave Certus Microwave Ablation System (NeuWave Medical, Madison, Wisconsin) in 71 patients (32 men and 39 women; mean age, 64.7 y ± 11.5). Ablation work was defined as sum of (power) * (time) * (number of antennas) for all phases during an ablation procedure. Ablation zone was measured on CT at 3 time points: after procedure, 1-3 months (mean 47 d), and 3-12 months (mean 292 d). Ablation zones were scored based on location for pulmonary lobe (upper = 1, middle/lingula = 2, lower = 3) and region (peripheral = 1, parenchymal = 2, central = 3), and the 2 were summed for ablation resistance score. RESULTS: Ablation zone on CT at 1-3 months was significantly smaller in regions with higher ablation resistance score (P < .05). There was a significant correlation between ablation work and ablation zone measured on CT performed after procedure (P < .001), at 1-3 months (P < .001), and at 3-12 months (P < .05). Ablation zone significantly decreased from after procedure to 1-3 months (P < .001) and from 1-3 months to 3-12 months (P < .001), with change from after procedure to 1-3 months significantly greater (P < .01). CONCLUSIONS: Pulmonary microwave ablation zone is significantly smaller in regions with higher ablation resistance score. Ablation work correlates to ablation zone with a nonlinear involution pattern in the first year and may be useful for planning before the procedure.


Asunto(s)
Técnicas de Ablación , Neoplasias Pulmonares/cirugía , Microondas/uso terapéutico , Técnicas de Ablación/efectos adversos , Anciano , Femenino , Humanos , Neoplasias Pulmonares/diagnóstico por imagen , Neoplasias Pulmonares/mortalidad , Neoplasias Pulmonares/patología , Masculino , Microondas/efectos adversos , Persona de Mediana Edad , Neoplasia Residual , Dinámicas no Lineales , Selección de Paciente , Valor Predictivo de las Pruebas , Radiografía Intervencional/métodos , Estudios Retrospectivos , Factores de Tiempo , Tomografía Computarizada por Rayos X , Resultado del Tratamiento , Carga Tumoral
14.
J Vasc Interv Radiol ; 26(1): 107-10, 2015 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-25541448

RESUMEN

The loop snare technique is a method for inferior vena cava (IVC) filter retrieval that creates a wire loop between the filter legs; this technique may fail in cases with an embedded hook. This report describes the hangman technique, a modified loop snare technique for filter retrieval that creates a wire loop between the filter neck and IVC wall for release of embedded filter hooks. The hangman technique was attempted in 11 cases complicated by tilt (mean tilt, 13.3 degrees ± 3.9) and an embedded hook (mean dwell time, 194.5 d) with a retrieval success rate of 81.8% (9 of 11 cases) and no associated complications.


Asunto(s)
Remoción de Dispositivos/métodos , Filtros de Vena Cava , Vena Cava Inferior/diagnóstico por imagen , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Flebografía , Estudios Retrospectivos , Adulto Joven
15.
J Vasc Interv Radiol ; 25(6): 933-9; quiz 940, 2014 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-24630748

RESUMEN

PURPOSE: To investigate the success and safety of routine versus advanced inferior vena cava (IVC) filter retrieval techniques. MATERIALS AND METHODS: A retrospective review was performed of patients who underwent IVC filter placement and/or a retrieval attempt over a 10-year period. Retrieval technique(s), preretrieval computed tomography, preretrieval venography, and clinical/imaging follow-up for 30 days after retrieval were analyzed. Mean filter dwell time was 134 days (range, 0-2,475 d). RESULTS: Filter retrieval was attempted 231 times in 217 patients (39% female, 61% male; mean age, 50.7 y), with success rates of 73.2% (169 of 231) and 94.7% (54 of 57) for routine and advanced filter retrieval techniques, respectively. The overall filter retrieval complication rate was 1.7% (four of 231); complications in four patients (with multiple complications in some cases) included IVC dissection, IVC intussusception, IVC thrombus/stenosis, filter fracture with embedded strut, IVC injury with hemorrhage, and vascular injury from complicated venous access. The rate of complications associated with filter retrievals that required advanced technique was significantly higher than seen with routine technique (5.3% vs 0.4%; P < .05). Longer dwell time, more transverse tilt, and presence of an embedded hook were associated with significantly increased rates of failed retrieval via routine technique (P < .05). CONCLUSIONS: IVC filters can be retrieved with a high overall success rate (98.2%) and a low complication rate (1.7%) by using advanced techniques when the routine approach has failed; however, the use of advanced techniques is associated with a significantly higher complication rate.


Asunto(s)
Remoción de Dispositivos/métodos , Procedimientos Endovasculares , Implantación de Prótesis/instrumentación , Filtros de Vena Cava , Vena Cava Inferior , Remoción de Dispositivos/efectos adversos , Procedimientos Endovasculares/efectos adversos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Flebografía/métodos , Estudios Retrospectivos , Tomografía Computarizada por Rayos X , Resultado del Tratamiento , Vena Cava Inferior/diagnóstico por imagen
18.
Cardiovasc Intervent Radiol ; 45(8): 1064-1073, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-35737099

RESUMEN

OBJECTIVE: There is no classification system for describing inferior vena cava (IVC) injuries. The objective of this study was to develop a standardized grading system for venographic appearance of the IVC following percutaneous IVC filter retrieval. METHODS: A classification system for the appearance of the IVC on cavograms following percutaneous IVC filter removal was developed consisting of two grading elements; luminal characteristics and extravasation. Luminal narrowing from 0% up to 50% from any cause is grade 1; narrowing between 50 and 99% is grade 2; occlusion is grade 3; and avulsion is grade 4. Absence of extravasation is grade A, contained extravasation is grade B, and free extravasation is grade C. This system was then applied retrospectively to pre- and post-IVC filter retrieval cavograms performed at a single institution from October 2004 through February 2019. RESULTS: 546 retrieval attempts were identified with 509 (93.2%) filters successfully retrieved. 449 cases (88.2%) had both pre-retrieval and post-retrieval imaging appropriate for application of the proposed classification system. Inter-rater reliability was 0.972 for luminal characteristics, 0.967 for extravasation, and 0.969 overall. Consensus grading demonstrated a distribution of 97.3% grade 1, 1.3% grade 2, 1.3% grade 3, and 0.0% grade 4 for post-retrieval luminal characteristics. For extravasation classification, 96.4% of the cases were classified as grade A, 2.7% grade B, and 0.9% grade C. CONCLUSION: A classification system was developed for describing IVC appearance after IVC filter retrieval, and retrospectively validated using a single center dataset.


Asunto(s)
Filtros de Vena Cava , Vena Cava Inferior , Remoción de Dispositivos/métodos , Humanos , Reproducibilidad de los Resultados , Estudios Retrospectivos , Vena Cava Inferior/diagnóstico por imagen , Vena Cava Inferior/cirugía
19.
Tech Vasc Interv Radiol ; 24(2): 100754, 2021 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-34602271

RESUMEN

Open surgical repair of dissections and post-dissection degenerative aneurysms involving the ascending thoracic aorta and aortic arch, whether in the acute or post-repair state, is associated with high rates of morbidity and mortality. Recent advancements in minimally invasive endovascular techniques have expanded the role of thoracic endovascular aortic repair (TEVAR) for dissections and dissection-related arch pathologies. Image-guided endovascular techniques, such as in situ fenestrated grafts, chimney and/or periscope grafts, along with newly developed commercially available branched aortic devices, have allowed for an increasing number of high-risk operative candidates to undergo definitive repair of aortic arch pathology who otherwise would have been destined for non-operative management. This paper reviews the data, pre-procedural planning, and technical considerations for complex TEVAR techniques for ascending and aortic arch dissections and dissection-related aneurysms.


Asunto(s)
Aneurisma de la Aorta Torácica , Disección Aórtica , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Disección Aórtica/diagnóstico por imagen , Disección Aórtica/cirugía , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/cirugía , Prótesis Vascular , Implantación de Prótesis Vascular/efectos adversos , Procedimientos Endovasculares/efectos adversos , Humanos , Complicaciones Posoperatorias , Diseño de Prótesis , Estudios Retrospectivos , Factores de Riesgo , Stents , Resultado del Tratamiento
20.
Diagn Interv Radiol ; 27(5): 644-648, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-34559049

RESUMEN

PURPOSE: We aimed to determine if lateral inferior vena cava (IVC) filter tilt at placement predicts the need for subsequent advanced retrieval techniques. METHODS: A retrospective chart review was performed of all Gunther Tulip IVC filter placements with subsequent retrievals between February 2015 and October 2017. Chart and imaging review was performed for patient, filter placement, and filter retrieval demographics/characteristics. Degree of agreement between two measurement sets was evaluated with the intraclass correlation (ICC) analysis. Categorical variables were compared with chi-square or Fisher exact test, as appropriate. Kendall rank correlation was used to measure correlation between categorical variables. RESULTS: There was poor agreement between filter tilt angle at the time of placement and retrieval (ICC coefficient, 0.54). Mean difference ± standard deviation between tilt angle at the time of placement and retrieval was 4.6°±4.3° (p = 0.35). Among patient- or procedure-related factors, a common femoral vein access on placement (regression coefficient, -2.90; p = 0.039) was associated with a lower difference between placement and retrieval filter tilt angles compared to internal jugular vein access. Higher filter tilt angle measured at the time of retrieval (OR: 1.19, p = 0.025), hook embedment (OR: 77.3, p < 0.001), and a longer dwell time (OR: 1.25, p = 0.002) were associated with the need for advanced retrieval techniques. However, in univariate and multivariate analysis filter tilt angle at the time of placement was not associated with the subsequent need for advanced retrieval technique (p = 0.16). CONCLUSION: Lateral tilt at the time of placement is poorly associated with lateral tilt at the time of retrieval and does not correlate with the need for advanced retrieval technique.


Asunto(s)
Remoción de Dispositivos , Filtros de Vena Cava , Vena Femoral , Humanos , Estudios Retrospectivos , Factores de Riesgo , Resultado del Tratamiento , Vena Cava Inferior/diagnóstico por imagen
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA