Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 29
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
NMR Biomed ; 37(6): e5122, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38369653

RESUMEN

Amide proton transfer weighted (APTw) imaging enables in vivo assessment of tissue-bound mobile proteins and peptides through the detection of chemical exchange saturation transfer. Promising applications of APTw imaging have been shown in adult brain tumors. As pediatric brain tumors differ from their adult counterparts, we investigate the radiological appearance of pediatric brain tumors on APTw imaging. APTw imaging was conducted at 3 T. APTw maps were calculated using magnetization transfer ratio asymmetry at 3.5 ppm. First, the repeatability of APTw imaging was assessed in a phantom and in five healthy volunteers by calculating the within-subject coefficient of variation (wCV). APTw images of pediatric brain tumor patients were analyzed retrospectively. APTw levels were compared between solid tumor tissue and normal-appearing white matter (NAWM) and between pediatric high-grade glioma (pHGG) and pediatric low-grade glioma (pLGG) using t-tests. APTw maps were repeatable in supratentorial and infratentorial brain regions (wCV ranged from 11% to 39%), except those from the pontine region (wCV between 39% and 50%). APTw images of 23 children with brain tumor were analyzed (mean age 12 years ± 5, 12 male). Significantly higher APTw values are present in tumor compared with NAWM for both pHGG and pLGG (p < 0.05). APTw values were higher in pLGG subtype pilocytic astrocytoma compared with other pLGG subtypes (p < 0.05). Non-invasive characterization of pediatric brain tumor biology with APTw imaging could aid the radiologist in clinical decision-making.


Asunto(s)
Amidas , Neoplasias Encefálicas , Fantasmas de Imagen , Protones , Humanos , Niño , Masculino , Femenino , Neoplasias Encefálicas/diagnóstico por imagen , Neoplasias Encefálicas/patología , Adolescente , Imagen por Resonancia Magnética/métodos , Glioma/diagnóstico por imagen , Glioma/patología , Reproducibilidad de los Resultados , Preescolar
2.
Breast Cancer Res Treat ; 201(1): 67-75, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-37322358

RESUMEN

PURPOSE: In breast conserving surgery, accurate lesion localization is essential for obtaining adequate surgical margins. Preoperative wire localization (WL) and radioactive seed localization (RSL) are widely accepted methods to guide surgical excision of nonpalpable breast lesions but are limited by logistical challenges, migration issues, and legislative complexities. Radiofrequency identification (RFID) technology may offer a viable alternative. The purpose of this study was to evaluate the feasibility, clinical acceptability, and safety of RFID surgical guidance for localization of nonpalpable breast cancer. METHODS: In a prospective multicentre cohort study, the first 100 RFID localization procedures were included. The primary outcome was the percentage of clear resection margins and re-excision rate. Secondary outcomes included procedure details, user experience, learningcurve, and adverse events. RESULTS: Between April 2019 and May 2021, 100 women underwent RFID guided breast conserving surgery. Clear resection margins were obtained in 89 out of 96 included patients (92.7%), re-excision was indicated in three patients (3.1%). Radiologists reported difficulties with the placement of the RFID tag, partially related to the relatively large needle-applicator (12-gauge). This led to the premature termination of the study in the hospital using RSL as regular care. The radiologist experience was improved after a manufacturer modification of the needle-applicator. Surgical localization involved a low learning curve. Adverse events (n = 33) included dislocation of the marker during insertion (8%) and hematomas (9%). The majority of adverse events (85%) occurred using the first-generation needle-applicator. CONCLUSION: RFID technology is a potential alternative for non-radioactive and non-wire localization of nonpalpable breast lesions.


Asunto(s)
Neoplasias de la Mama , Femenino , Humanos , Neoplasias de la Mama/diagnóstico por imagen , Neoplasias de la Mama/cirugía , Estudios Prospectivos , Márgenes de Escisión , Estudios de Cohortes , Estudios de Factibilidad , Mastectomía Segmentaria/métodos
3.
Ann Surg Oncol ; 30(13): 8735-8742, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37661223

RESUMEN

OBJECTIVE: This study investigates the performance of the DiffMag handheld probe (nonlinear magnetometry), to be used for sentinel lymph node detection. Furthermore, the performance of DiffMag is compared with a gamma probe and a first-order magnetometer (Sentimag®, linear magnetometry). METHODS: The performance of all three probes was evaluated based on longitudinal distance, transverse distance, and resolving power for two tracer volumes. A phantom was developed to investigate the performance of the probes for a clinically relevant situation in the floor of the mouth (FOM). RESULTS: Considering the longitudinal distance, both DiffMag handheld and Sentimag® probe had comparable performance, while the gamma probe was able to detect at least a factor of 10 deeper. Transverse distances of 13, 11, and 51 mm were measured for the small tracer volume by the DiffMag handheld, Sentimag®, and the gamma probe, respectively. For the large tracer volume this was 21, 18, and 55 mm, respectively. The full width at half maximum, at 7 mm probe height from the phantom surface, was 14, 12, and 18 mm for the small tracer volume and 15, 18, and 25 mm for the large tracer volume with the DiffMag handheld, Sentimag®, and gamma probe, respectively. CONCLUSIONS: With a high resolving power but limited longitudinal distance, the DiffMag handheld probe seems suitable for detecting SLNs which are in close proximity to the primary tumor. In this study, comparable results were shown using linear magnetometry. The gamma probe reached 10 times deeper, but has a lower resolving power compared with the DiffMag handheld probe.


Asunto(s)
Nanopartículas de Magnetita , Ganglio Linfático Centinela , Humanos , Ganglio Linfático Centinela/patología , Biopsia del Ganglio Linfático Centinela/métodos , Magnetometría , Fenómenos Magnéticos , Ganglios Linfáticos/patología
4.
J Comput Assist Tomogr ; 47(1): 93-101, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36219722

RESUMEN

OBJECTIVE: Intracerebral hemorrhage (ICH) volume is a strong predictor of outcome in patients presenting with acute hemorrhagic stroke. It is necessary to segment the hematoma for ICH volume estimation and for computerized extraction of features, such as spot sign, texture parameters, or extravasated iodine content at dual-energy computed tomography. Manual and semiautomatic segmentation methods to delineate the hematoma are tedious, user dependent, and require trained personnel. This article presents a convolutional neural network to automatically delineate ICH from noncontrast computed tomography scans of the head. METHODS: A model combining a U-Net architecture with a masked loss function was trained on standard noncontrast computed tomography images that were down sampled to 256 × 256 size. Data augmentation was applied to prevent overfitting, and the loss score was calculated using the soft Dice loss function. The Dice coefficient and the Hausdorff distance were computed to quantitatively evaluate the segmentation performance of the model, together with the sensitivity and specificity to determine the ICH detection accuracy. RESULTS: The results demonstrate a median Dice coefficient of 75.9% and Hausdorff distance of 2.65 pixels in segmentation performance, with a detection sensitivity of 77.0% and specificity of 96.2%. CONCLUSIONS: The proposed masked loss U-Net is accurate in the automatic segmentation of ICH. Future research should focus on increasing the detection sensitivity of the model and comparing its performance with other model architectures.


Asunto(s)
Accidente Cerebrovascular , Tomografía Computarizada por Rayos X , Humanos , Tomografía Computarizada por Rayos X/métodos , Hemorragia Cerebral/diagnóstico por imagen , Redes Neurales de la Computación , Hematoma , Sensibilidad y Especificidad , Procesamiento de Imagen Asistido por Computador/métodos
5.
Proc Natl Acad Sci U S A ; 117(18): 9942-9951, 2020 05 05.
Artículo en Inglés | MEDLINE | ID: mdl-32321835

RESUMEN

Genetic variants within complement factor H (CFH), a major alternative complement pathway regulator, are associated with the development of age-related macular degeneration (AMD) and other complementopathies. This is explained with the reduced binding of CFH or its splice variant factor H-like protein 1 (FHL-1) to self-ligands or altered self-ligands (e.g., malondialdehyde [MDA]-modified molecules) involved in homeostasis, thereby causing impaired complement regulation. Considering the critical role of CFH in inhibiting alternative pathway activation on MDA-modified surfaces, we performed an unbiased genome-wide search for genetic variants that modify the ability of plasma CFH to bind MDA in 1,830 individuals and characterized the mechanistic basis and the functional consequences of this. In a cohort of healthy individuals, we identified rs1061170 in CFH and the deletion of CFHR3 and CFHR1 as dominant genetic variants that modify CFH/FHL-1 binding to MDA. We further demonstrated that FHR1 and FHR3 compete with CFH for binding to MDA-epitopes and that FHR1 displays the highest affinity toward MDA-epitopes compared to CFH and FHR3. Moreover, FHR1 bound to MDA-rich areas on necrotic cells and prevented CFH from mediating its cofactor activity on MDA-modified surfaces, resulting in enhanced complement activation. These findings provide a mechanistic explanation as to why the deletion of CFHR3 and CFHR1 is protective in AMD and highlight the importance of genetic variants within the CFH/CFHR3/CFHR1 locus in the recognition of altered-self in tissue homeostasis.


Asunto(s)
Proteínas Sanguíneas/genética , Proteínas Inactivadoras del Complemento C3b/genética , Degeneración Macular/genética , Anciano , Factor H de Complemento/genética , Epítopos/genética , Femenino , Predisposición Genética a la Enfermedad , Estudio de Asociación del Genoma Completo , Humanos , Degeneración Macular/patología , Masculino , Malondialdehído/metabolismo , Persona de Mediana Edad , Polimorfismo de Nucleótido Simple/genética , Unión Proteica
6.
Muscle Nerve ; 64(1): 8-22, 2021 07.
Artículo en Inglés | MEDLINE | ID: mdl-33269474

RESUMEN

There is a great demand for accurate non-invasive measures to better define the natural history of disease progression or treatment outcome in Duchenne muscular dystrophy (DMD) and to facilitate the inclusion of a large range of participants in DMD clinical trials. This review aims to investigate which MRI sequences and analysis methods have been used and to identify future needs. Medline, Embase, Scopus, Web of Science, Inspec, and Compendex databases were searched up to 2 November 2019, using keywords "magnetic resonance imaging" and "Duchenne muscular dystrophy." The review showed the trend of using T1w and T2w MRI images for semi-qualitative inspection of structural alterations of DMD muscle using a diversity of grading scales, with increasing use of T2map, Dixon, and MR spectroscopy (MRS). High-field (>3T) MRI dominated the studies with animal models. The quantitative MRI techniques have allowed a more precise estimation of local or generalized disease severity. Longitudinal studies assessing the effect of an intervention have also become more prominent, in both clinical and animal model subjects. Quality assessment of the included longitudinal studies was performed using the Newcastle-Ottawa Quality Assessment Scale adapted to comprise bias in selection, comparability, exposure, and outcome. Additional large clinical trials are needed to consolidate research using MRI as a biomarker in DMD and to validate findings against established gold standards. This future work should use a multiparametric and quantitative MRI acquisition protocol, assess the repeatability of measurements, and correlate findings to histologic parameters.


Asunto(s)
Estudios de Evaluación como Asunto , Imagen por Resonancia Magnética/métodos , Imagen por Resonancia Magnética/normas , Músculo Esquelético/diagnóstico por imagen , Distrofia Muscular de Duchenne/diagnóstico por imagen , Animales , Humanos , Músculo Esquelético/patología , Distrofia Muscular de Duchenne/patología
7.
Clin Chem Lab Med ; 59(1): 71-77, 2020 07 06.
Artículo en Inglés | MEDLINE | ID: mdl-32628627

RESUMEN

Objectives: Young laboratory medicine professionals (YLMPs) are the future of clinical laboratories. Although everyday practice shows significant differences among countries, especially during residency training, most of them face the same challenges. Besides promoting scientific, professional and clinical aspects of laboratory medicine in Europe, the European Federation of Clinical Chemistry and Laboratory Medicine (EFLM) should take into consideration YLMPs' concerns and interests to help them achieve excellence. The aim of this survey was to assess the opinion and expectations of YLMPs about their involvement in the activities of EFLM. Methods: An online survey was distributed to YLMPs in Europe through different channels. The questionnaire consisted of 21 items grouped into five sections: demographic questions, opinion about the current status of YLMPs within EFLM, YLMPs network, suggestions and opportunities, and scientific training and exchange. Where appropriate, responses from residents and specialists were compared. Results: A total of 329 valid responses were obtained from 53 different countries. Countries with the highest number of participants were Spain, Turkey, Croatia and Romania. A significant percentage would like to know more about EFLM and their activities (86%) and wish EFLM promoted networking and scientific exchanges (95%), for instance by means of a European YLMPs network (93%). EFLMLabX project was widely unknown (75%). Conclusions: YLMPs demand better connection to share concerns about daily healthcare duties, to keep updated and to advance professionally. EFLM needs to improve their advertising through national societies to increase YLMPs' participation. In addition to international meetings and congresses, respondents have emphasized that workshops and other small group activities would significantly help promote laboratory medicine practice in Europe.


Asunto(s)
Química Clínica/estadística & datos numéricos , Personal de Laboratorio Clínico/estadística & datos numéricos , Ciencia del Laboratorio Clínico/estadística & datos numéricos , Encuestas y Cuestionarios , Adulto , Actitud del Personal de Salud , Europa (Continente) , Humanos , Internet , Personal de Laboratorio Clínico/psicología , Motivación , Red Social , Adulto Joven
8.
J Digit Imaging ; 33(5): 1224-1241, 2020 10.
Artículo en Inglés | MEDLINE | ID: mdl-32607906

RESUMEN

Recent emerging hybrid technology of positron emission tomography/magnetic resonance (PET/MR) imaging has generated a great need for an accurate MR image-based PET attenuation correction. MR image segmentation, as a robust and simple method for PET attenuation correction, has been clinically adopted in commercial PET/MR scanners. The general approach in this method is to segment the MR image into different tissue types, each assigned an attenuation constant as in an X-ray CT image. Machine learning techniques such as clustering, classification and deep networks are extensively used for brain MR image segmentation. However, only limited work has been reported on using deep learning in brain PET attenuation correction. In addition, there is a lack of clinical evaluation of machine learning methods in this application. The aim of this review is to study the use of machine learning methods for MR image segmentation and its application in attenuation correction for PET brain imaging. Furthermore, challenges and future opportunities in MR image-based PET attenuation correction are discussed.


Asunto(s)
Procesamiento de Imagen Asistido por Computador , Imagen por Resonancia Magnética , Encéfalo/diagnóstico por imagen , Humanos , Aprendizaje Automático , Tomografía de Emisión de Positrones
9.
Muscle Nerve ; 60(5): 621-628, 2019 11.
Artículo en Inglés | MEDLINE | ID: mdl-31397906

RESUMEN

INTRODUCTION: Golden retriever muscular dystrophy (GRMD) is a spontaneous X-linked canine model of Duchenne muscular dystrophy that resembles the human condition. Muscle percentage index (MPI) is proposed as an imaging biomarker of disease severity in GRMD. METHODS: To assess MPI, we used MRI data acquired from nine GRMD samples using a 4.7 T small-bore scanner. A machine learning approach was used with eight raw quantitative mapping of MRI data images (T1m, T2m, two Dixon maps, and four diffusion tensor imaging maps), three types of texture descriptors (local binary pattern, gray-level co-occurrence matrix, gray-level run-length matrix), and a gradient descriptor (histogram of oriented gradients). RESULTS: The confusion matrix, averaged over all samples, showed 93.5% of muscle pixels classified correctly. The classification, optimized in a leave-one-out cross-validation, provided an average accuracy of 80% with a discrepancy in overestimation for young (8%) and old (20%) dogs. DISCUSSION: MPI could be useful for quantifying GRMD severity, but careful interpretation is needed for severe cases.


Asunto(s)
Músculo Esquelético/diagnóstico por imagen , Distrofia Muscular Animal/diagnóstico por imagen , Animales , Modelos Animales de Enfermedad , Perros , Imagen por Resonancia Magnética , Músculo Esquelético/patología , Distrofia Muscular Animal/patología , Distrofia Muscular de Duchenne/diagnóstico por imagen , Distrofia Muscular de Duchenne/patología , Índice de Severidad de la Enfermedad
10.
Muscle Nerve ; 59(3): 380-386, 2019 03.
Artículo en Inglés | MEDLINE | ID: mdl-30461036

RESUMEN

INTRODUCTION: Golden retriever muscular dystrophy (GRMD), an X-linked recessive disorder, causes similar phenotypic features to Duchenne muscular dystrophy (DMD). There is currently a need for a quantitative and reproducible monitoring of disease progression for GRMD and DMD. METHODS: To assess severity in the GRMD, we analyzed texture features extracted from multi-parametric MRI (T1w, T2w, T1m, T2m, and Dixon images) using 5 feature extraction methods and classified using support vector machines. RESULTS: A single feature from qualitative images can provide 89% maximal accuracy. Furthermore, 2 features from T1w, T2m, or Dixon images provided highest accuracy. When considering a tradeoff between scan-time and computational complexity, T2m images provided good accuracy at a lower acquisition and processing time and effort. CONCLUSIONS: The combination of MRI texture features improved the classification accuracy for assessment of disease progression in GRMD with evaluation of the heterogenous nature of skeletal muscles as reflection of the histopathological changes. Muscle Nerve 59:380-386, 2019.


Asunto(s)
Enfermedades de los Perros/diagnóstico por imagen , Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Magnética/métodos , Distrofia Muscular Animal/diagnóstico por imagen , Animales , Biomarcadores , Perros , Músculo Esquelético/diagnóstico por imagen , Distrofia Muscular de Duchenne/patología , Máquina de Vectores de Soporte
11.
Med Arch ; 70(1): 31-4, 2016 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-26980928

RESUMEN

INTRODUCTION: Renalase is a protein secreted in kidneys and considered as a blood pressure modulator. High rates of hypertension and its regulation in patients on hemodialysis demands search for potential cause and treatment. The aim of this study was to determine the genotype and allele frequencies of renalase gene rs2576178 polymorphism in population from Bosnia and Herzegovina. Also, the objective of present study was to find the possible association between renalase gene rs2576178 polymorphism and hypertension in patients on hemodialysis. MATERIAL AND METHODS: The genotype of renalase gene rs2576178 polymorphism was determined in 137 participants (100 patients on hemodialysis and 37 controls), using polymerase chain reaction (PCR) and subsequent cleavage with MspI restriction endonuclease. Genotype and allele frequencies were assessed for Hardy-Weinberg equilibrium using a Chi-squared test. The value of P<0.05 was considered as statistically significant. RESULTS: Comparison of genotype distribution and allele frequency in participants on hemodialysis with and without hypertension, and healthy control showed no statistical difference. CONCLUSION: The results of the study suggest that renalase gene rs2576178 polymorphism is not a factor that influences blood pressure in patients on hemodialysis.


Asunto(s)
Monoaminooxidasa/genética , Polimorfismo Genético , Diálisis Renal , Insuficiencia Renal Crónica/genética , Insuficiencia Renal Crónica/terapia , Adolescente , Adulto , Anciano , Biomarcadores/sangre , Bosnia y Herzegovina , Estudios de Casos y Controles , Femenino , Frecuencia de los Genes , Genotipo , Humanos , Masculino , Persona de Mediana Edad , Diálisis Renal/métodos , Insuficiencia Renal Crónica/sangre
12.
Surg Innov ; 22(6): 557-67, 2015 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-25652527

RESUMEN

BACKGROUND: In colorectal surgery, detecting ureters and mesenteric arteries is of utmost importance to prevent iatrogenic injury and to facilitate intraoperative decision making. A tool enabling ureter- and artery-specific image enhancement within (and possibly through) surrounding adipose tissue would facilitate this need, especially during laparoscopy. To evaluate the potential of hyperspectral imaging in colorectal surgery, we explored spectral tissue signatures using single-spot diffuse reflectance spectroscopy (DRS). As hyperspectral cameras with silicon (Si) and indium gallium arsenide (InGaAs) sensor chips are becoming available, we investigated spectral distinctive features for both sensor ranges. METHODS: In vivo wide-band (wavelength range 350-1830 nm) DRS was performed during open colorectal surgery. From the recorded spectra, 36 features were extracted at predefined wavelengths: 18 gradients and 18 amplitude differences. For classification of respectively ureter and artery in relation to surrounding adipose tissue, the best distinctive feature was selected using binary logistic regression for Si- and InGaAs-sensor spectral ranges separately. Classification performance was evaluated by leave-one-out cross-validation. RESULTS: In 10 consecutive patients, 253 spectra were recorded on 53 tissue sites (including colon, adipose tissue, muscle, artery, vein, ureter). Classification of ureter versus adipose tissue revealed accuracy of 100% for both Si range and InGaAs range. Classification of artery versus surrounding adipose tissue revealed accuracies of 95% (Si) and 89% (InGaAs). CONCLUSIONS: Intraoperative DRS showed that Si and InGaAs sensors are equally suited for automated classification of ureter versus surrounding adipose tissue. Si sensors seem better suited for classifying artery versus mesenteric adipose tissue. Progress toward hyperspectral imaging within this field is promising.


Asunto(s)
Cirugía Colorrectal/métodos , Análisis Espectral/métodos , Cirugía Asistida por Computador/métodos , Tejido Adiposo/química , Anciano , Anciano de 80 o más Años , Arsenicales , Femenino , Galio , Humanos , Indio , Masculino , Arterias Mesentéricas/química , Persona de Mediana Edad , Silicio , Uréter/química
13.
Lasers Surg Med ; 46(7): 538-45, 2014 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-24895321

RESUMEN

BACKGROUND: Intraoperative nerve localization is of great importance in surgery. In certain procedures, where nerves show visual resemblance to surrounding adipose tissue, this can be particularly challenging for the human eye. An example of such a delicate procedure is thyroid and parathyroid surgery, where iatrogenic injury of the recurrent laryngeal nerve can result in transient or permanent vocal problems (0.5-2.0% reported incidence). A camera system, enabling nerve-specific image enhancement, would be useful in preventing such complications. This might be realized with hyperspectral camera technology using silicon (Si) or indium gallium arsenide (InGaAs) sensor chips. METHODS: As a first step towards such a camera, we evaluated the performance of diffuse reflectance spectroscopy by analysing spectra collected during 18 thyroid and parathyroid resections. We assessed the contrast information present in two different spectral ranges, for respectively Si and InGaAs sensors. Two hundred fifty three in vivo, wide-band diffuse reflectance spectra (350-1,830 nm range, 1 nm resolution) were acquired on 52 tissue spots, including nerve (n = 22), muscle (n = 12), and adipose tissue (n = 18). We extracted 36 features from these spectroscopic data: 18 gradients and 18 amplitude differences at predefined points in the tissue spectra. Best distinctive feature combinations were established using binary logistic regression. Classification performance was evaluated in a cross-validation (CV) approach by leave-one-out (LOO). To generalize nerve recognition applicability, we performed a train-test (TT) validation using the thyroid and parathyroid surgery data for training purposes and carpal tunnel release surgery data (10 nerve spots and 5 adipose spots) for classification purposes. RESULTS: For combinations of two distinctive spectral features, LOO revealed an accuracy of respectively 78% for Si-sensors and 95% for InGaAs-sensors. TT revealed accuracies of respectively 67% and 100%. CONCLUSIONS: Using diffuse reflectance spectroscopy we have identified that InGaAs sensors are better suited for automated discrimination between nerves and surrounding adipose tissue than Si sensors.


Asunto(s)
Tejido Adiposo/anatomía & histología , Sistema Nervioso/anatomía & histología , Análisis Espectral/métodos , Adolescente , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Adulto Joven
14.
Med Glas (Zenica) ; 21(1): 78-84, 2024 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-38341634

RESUMEN

Aim To analyse the impact of the length of antiviral therapy with tenofovir disoproxil fumarate (TDF) on the renal function in patients with chronic hepatitis B (CHB). Methods A cross-sectional study included 75 patients with CHB treated with tenofovir, who had a normal renal function at the beginning of the treatment. Renal function was determined based on glomerular filtration rate (eGFR) value using the Modification of Diet in Renal Disease formula (MDRD). Measurement of serum creatinine concentration and urinary protein excretion were performed using standard laboratory analyses. Viral load quantification (HBV-DNA) was determined by polymerase chain reaction (PCR). The degree of liver fibrosis was determined using fibrosis4 (FIB-4) and aspartate transaminase to platelet ratio index (APRI) fibrosis score. Results Out of 75 CHB patients, 37 were on antiviral treatment for up to 2 years (group 1) and 38 patients on antiviral treatment longer than two years (group 2). Mean age of patients was not significantly different between the groups (p=0.076), nor was the gender distribution. There was no statistically significant difference between the mean values of the eGFR in the two groups (91.89±9.24 vs. 88.42±7.84 mL/min/1.73m2; p=0.42), as well as between the mean values of serum creatinine (p=0.360) and 24-hour urine protein excretion (p=0.380). There was no statistically significant correlation between renal parameters and viral load, APRI and FIB-4 fibrosis score. Conclusion Results of our study did not show significant changes in the measured parameters of renal function in group 1 and group 2 of patients, regardless of the length of antiviral treatment, indicating a good renal safety profile of TDF.

15.
Bioact Mater ; 39: 406-426, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38855059

RESUMEN

Endothelin-1/endothelin A receptor (ET-1/ETAR) pathway plays an important role in the progression of liver fibrosis by activating hepatic stellate cells (HSCs) - a key cell type involved in the pathogenesis of liver fibrosis. Inactivating HSCs by blocking the ET-1/ETAR pathway using a selective ETAR antagonist (ERA) represents a promising therapeutic approach for liver fibrosis. Unfortunately, small-molecule ERAs possess limited clinical potential due to poor bioavailability, short half-life, and rapid renal clearance. To improve the clinical applicability, we conjugated ERA to superparamagnetic iron-oxide nanoparticles (SPIONs) and investigated the therapeutic efficacy of ERA and ERA-SPIONs in vitro and in vivo and analyzed liver uptake by in vivo and ex vivo magnetic resonance imaging (MRI), HSCs-specific localization, and ET-1/ETAR-pathway antagonism in vivo. In murine and human liver fibrosis/cirrhosis, we observed overexpression of ET-1 and ETAR that correlated with HSC activation, and HSC-specific localization of ETAR. ERA and successfully synthesized ERA-SPIONs demonstrated significant attenuation in TGFß-induced HSC activation, ECM production, migration, and contractility. In an acute CCl4-induced liver fibrosis mouse model, ERA-SPIONs exhibited higher liver uptake, HSC-specific localization, and ET-1/ETAR pathway antagonism. This resulted in significantly reduced liver-to-body weight ratio, plasma ALT levels, and α-SMA and collagen-I expression, indicating attenuation of liver fibrosis. In conclusion, our study demonstrates that the delivery of ERA using SPIONs enhances the therapeutic efficacy of ERA in vivo. This approach holds promise as a theranostic strategy for the MRI-based diagnosis and treatment of liver fibrosis.

16.
Life (Basel) ; 13(2)2023 Jan 28.
Artículo en Inglés | MEDLINE | ID: mdl-36836713

RESUMEN

BACKGROUND: In vivo diffuse reflectance spectroscopy provides additional contrast in discriminating nerves embedded in adipose tissue during surgery. However, large datasets are required to achieve clinically acceptable classification levels. This study assesses the spectral similarity between ex vivo porcine and in vivo human spectral data of nerve and adipose tissue, as porcine tissue could contribute to generate large datasets. METHODS: Porcine diffuse reflectance spectra were measured at 124 nerve and 151 adipose locations. A previously recorded dataset of 32 in vivo human nerve and 23 adipose tissue locations was used for comparison. In total, 36 features were extracted from the raw porcine to generate binary logistic regression models for all combinations of two, three, four and five features. Feature selection was performed by assessing similar means between normalized features of nerve and of adipose tissue (Kruskal-Wallis test, p < 0.05) and for models performing best on the porcine cross validation set. The human test set was used to assess classification performance. RESULTS: The binary logistic regression models with selected features showed an accuracy of 60% on the test set. CONCLUSIONS: Spectral similarity between ex vivo porcine and in vivo human adipose and nerve tissue was present, but further research is required.

17.
Front Immunol ; 13: 1010893, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36248824

RESUMEN

Cellular death, aging, and tissue damage trigger inflammation that leads to enzymatic and non-enzymatic lipid peroxidation of polyunsaturated fatty acids present on cellular membranes and lipoproteins. This results in the generation of highly reactive degradation products, such as malondialdehyde (MDA) and 4-hydroxynonenal (4-HNE), that covalently modify free amino groups of proteins and lipids in their vicinity. These newly generated neoepitopes represent a unique set of damage-associated molecular patterns (DAMPs) associated with oxidative stress termed oxidation-specific epitopes (OSEs). OSEs are enriched on oxidized lipoproteins, microvesicles, and dying cells, and can trigger sterile inflammation. Therefore, prompt recognition and removal of OSEs is required to maintain the homeostatic balance. This is partially achieved by various humoral components of the innate immune system, such as natural IgM antibodies, pentraxins and complement components that not only bind OSEs but in some cases modulate their pro-inflammatory potential. Natural IgM antibodies are potent complement activators, and 30% of them recognize OSEs such as oxidized phosphocholine (OxPC-), 4-HNE-, and MDA-epitopes. Furthermore, OxPC-epitopes can bind the complement-activating pentraxin C-reactive protein, while MDA-epitopes are bound by C1q, C3a, complement factor H (CFH), and complement factor H-related proteins 1, 3, 5 (FHR-1, FHR-3, FHR-5). In addition, CFH and FHR-3 are recruited to 2-(ω-carboxyethyl)pyrrole (CEP), and full-length CFH also possesses the ability to attenuate 4-HNE-induced oxidative stress. Consequently, alterations in the innate humoral defense against OSEs predispose to the development of diseases associated with oxidative stress, as shown for the prototypical OSE, MDA-epitopes. In this mini-review, we focus on the mechanisms of the accumulation of OSEs, the pathophysiological consequences, and the interactions between different OSEs and complement components. Additionally, we will discuss the clinical potential of genetic variants in OSE-recognizing complement proteins - the OSE complotype - in the risk estimation of diseases associated with oxidative stress.


Asunto(s)
Proteína C-Reactiva , Factor H de Complemento , Complemento C1q , Epítopos , Humanos , Inmunoglobulina M , Factores Inmunológicos , Inflamación , Lípidos , Malondialdehído , Fosforilcolina
18.
Cancers (Basel) ; 14(3)2022 Jan 28.
Artículo en Inglés | MEDLINE | ID: mdl-35158946

RESUMEN

A magnetic sentinel lymph node biopsy ((SLN)B) procedure has recently been shown feasible in oral cancer patients. However, a grading system is absent for proper identification and classification, and thus for clinical reporting. Based on data from eight complete magnetic SLNB procedures, we propose a provisional grading system. This grading system includes: (1) a qualitative five-point grading scale for MRI evaluation to describe iron uptake by LNs; (2) an ex vivo count of resected SLN with a magnetic probe to quantify iron amount; and (3) a qualitative five-point grading scale for histopathologic examination of excised magnetic SLNs. Most SLNs with iron uptake were identified and detected in level II. In this level, most variance in grading was seen for MRI and histopathology; MRI and medullar sinus were especially highly graded, and cortical sinus was mainly low graded. On average 82 ± 58 µg iron accumulated in harvested SLNs, and there were no significant differences in injected tracer dose (22.4 mg or 11.2 mg iron). In conclusion, a first step was taken in defining a comprehensive grading system to gain more insight into the lymphatic draining system during a magnetic SLNB procedure.

19.
IEEE Trans Biomed Eng ; 69(1): 286-293, 2022 01.
Artículo en Inglés | MEDLINE | ID: mdl-34170819

RESUMEN

OBJECTIVE: Sentinel lymph node harvesting is an essential step in the surgical treatment of a growing number of malignancies. Various techniques are available to facilitate this purpose. The present study reports a new laparoscopic technique for lymph node harvesting using magnetic nanoparticles containing a superparamagnetic iron-oxide core and dextran coating. This study assesses the clinical relevance of the prototype and provides input for further technological development on the way to clinical implementation. METHODS: A laparoscopic differential magnetometer prototype was built, utilizing a nonlinear detection principle (differential magnetometry) for magnetic identification of lymph nodes. The iron content sensitivity, depth & spatial sensitivity, and angular sensitivity were analyzed to investigate clinical options. RESULTS: The minimum detectable amount of iron was 9.8 µg at a distance of 1 mm. The detection depth was 5, 8, and 10 mm for samples containing 126, 252, and 504 µg iron, respectively. The maximum lateral detection distance was 5, 7, and 8 mm for samples containing 126, 252, and 504 µg iron, respectively. A sample containing 504 µg iron was detectable at all angulations assessed (0°, 30°, 60° and 90°). CONCLUSION: The laparoscopic differential magnetometer demonstrates promising results for further investigation and development towards laparoscopic lymph node harvesting using magnetic nanoparticles. SIGNIFICANCE: The laparoscopic differential magnetometer facilitates a novel method for sentinel lymph node harvesting, which helps to determine prognosis and treatment of cancer patients.


Asunto(s)
Laparoscopía , Nanopartículas de Magnetita , Ganglio Linfático Centinela , Humanos , Ganglios Linfáticos/cirugía , Magnetometría , Ganglio Linfático Centinela/diagnóstico por imagen , Ganglio Linfático Centinela/cirugía , Biopsia del Ganglio Linfático Centinela
20.
Int J Comput Assist Radiol Surg ; 17(1): 211-218, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-34333740

RESUMEN

PURPOSE: Sentinel lymph node biopsy is a routine procedure for nodal staging in penile cancer. Most commonly, this procedure is guided by radioactive tracers, providing various forms of preoperative and intraoperative guidance. This is further extended with fluorescence imaging using hybrid radioactive-fluorescence tracers. Alternatively, a magnetic-based approach has become available using superparamagnetic iron-oxide nanoparticles (SPIONs). This study investigates a novel freehand magnetic particle imaging and navigation modality (fhMPI) for intraoperative localization, along with a hybrid approach, combining magnetic and fluorescence guidance. MATERIALS AND METHODS: The fhMPI set-up was built with a surgical navigation device, optical tracking system and magnetometer probe. A dedicated reconstruction software based on a look-up-table method was used to reconstruct a superficial 3D volume of the SPION distribution in tissue. For fluorescence guidance, indocyanine green (ICG) was added to the SPIONs. The fhMPI modality was characterized in phantoms, ex vivo human skin and in vivo porcine surgery. RESULTS: Phantom and human skin explants illustrated that the current fhMPI modality had a sensitivity of 2.2 × 10-2 mg/mL SPIONs, a resolving power of at least 7 mm and a depth penetration up to 1.5 cm. Evaluation during porcine surgery showed that fhMPI allowed for an augmented reality image overlay of the tracer distribution in tissue, as well as 3D virtual navigation. Besides, using the hybrid approach, fluorescence imaging provided a visual confirmation of localized nodes. CONCLUSION: fhMPI is feasible in vivo, providing 3D imaging and navigation for magnetic nanoparticles in the operating room, expanding the guidance possibilities during magnetic sentinel lymph node procedures. Furthermore, the integration of ICG provides the ability to visually refine and confirm correct localization. Further clinical evaluation should verify these findings in human patients as well.


Asunto(s)
Imagenología Tridimensional , Cirugía Asistida por Computador , Animales , Humanos , Verde de Indocianina , Imagen Óptica , Biopsia del Ganglio Linfático Centinela , Porcinos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA