Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros

Bases de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
J Nucl Med ; 63(6): 833-839, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-34531260

RESUMEN

Radiohybrid prostate-specific membrane antigen (rhPSMA) ligands allow for labeling with 18F and radiometals for endoradiotherapy. rhPSMA-7.3 has been designated as a lead compound with promising preclinical data for 177Lu-rhPSMA-7.3, which has shown higher tumor uptake than 177Lu-PSMA I&T. In this retrospective analysis, we compared pretherapeutic clinical dosimetry data of both PSMA ligands. Methods: Six patients with metastatic castration-resistant prostate cancer underwent both 177Lu-rhPSMA-7.3 and 177Lu-PSMA I&T pretherapeutic dosimetry. Whole-body scintigraphy was performed at 1 h, 4 h, 24 h, 48 h, and 7 d after injection. Regions of interest covering the whole body, organs, bone marrow, and tumor lesions were drawn for each patient. Absorbed doses for individual patients and pretherapeutic applications were calculated using OLINDA/EXM. To facilitate the comparison of both ligands, we introduced the therapeutic index (TI), defined as the ratio of mean pretherapeutic doses to tumor lesions over relevant organs at risk. Results: Mean whole-body pretherapeutic effective doses for 177Lu-rhPSMA-7.3 and 177Lu-PSMA I&T were 0.12 ± 0.07 and 0.05 ± 0.03 Sv/GBq, respectively. Mean absorbed organ doses for 177Lu-rhPSMA-7.3 and 177Lu-PSMA I&T were, for example, 1.65 ± 0.28 and 0.73 ± 0.18 Gy/GBq for the kidneys, 0.19 ± 0.09 and 0.07 ± 0.03 Gy/GBq for the liver, 2.35 ± 0.78 and 0.80 ± 0.41 Gy/GBq for the parotid gland, and 0.67 ± 0.62 and 0.30 ± 0.27 Gy/GBq for the bone marrow, respectively. Tumor lesions received mean absorbed doses of 177Lu-rhPSMA-7.3 and 177Lu-PSMA I&T of 6.44 ± 6.44 and 2.64 ± 2.24 Gy/GBq, respectively. The mean TIs for the kidneys were 3.7 ± 2.2 and 3.6 ± 2.2 for 177Lu-rhPSMA-7.3 and 177Lu-PSMA I&T, respectively, and those for the bone marrow were 15.2 ± 10.2 and 15.1 ± 10.2 for 177Lu-rhPSMA-7.3 and 177Lu-PSMA I&T, respectively. Conclusion: Pretherapeutic clinical dosimetry confirmed preclinical results of mean absorbed doses for tumors that were 2-3 times higher for 177Lu-rhPSMA-7.3 than for 177Lu-PSMA I&T. Absorbed doses to normal organs also tended to be higher for 177Lu-rhPSMA-7.3, resulting overall in similar average TIs for both radiopharmaceuticals with considerable interpatient variability. 177Lu-rhPSMA-7.3 has promise for a therapeutic efficacy similar to that of 177Lu-PSMA I&T at smaller amounts of injected activity, simplifying radiation safety measurements (especially for large patient numbers or dose escalation regimens).


Asunto(s)
Neoplasias de la Próstata Resistentes a la Castración , Dipéptidos/uso terapéutico , Compuestos Heterocíclicos con 1 Anillo/uso terapéutico , Humanos , Ligandos , Lutecio/uso terapéutico , Masculino , Antígeno Prostático Específico , Neoplasias de la Próstata Resistentes a la Castración/patología , Radiofármacos/efectos adversos , Estudios Retrospectivos , Tomografía Computarizada por Rayos X , Urea/análogos & derivados
2.
J Nucl Med ; 60(1): 65-70, 2019 01.
Artículo en Inglés | MEDLINE | ID: mdl-29748236

RESUMEN

The aim of this work was to develop a theranostic method that allows prediction of prostate-specific membrane antigen (PSMA)-positive tumor volume after radioligand therapy (RLT) based on a pretherapeutic PET/CT measurement and physiologically based pharmacokinetic/pharmacodynamic (PBPK/PD) modeling at the example of RLT using 177Lu-labeled PSMA for imaging and therapy (PSMA I&T). Methods: A recently developed PBPK model for 177Lu-PSMA I&T RLT was extended to account for tumor (exponential) growth and reduction due to irradiation (linear quadratic model). Data from 13 patients with metastatic castration-resistant prostate cancer were retrospectively analyzed. Pharmacokinetic/pharmacodynamic parameters were simultaneously fitted in a Bayesian framework to PET/CT activity concentrations, planar scintigraphy data, and tumor volumes before and after (6 wk) therapy. The method was validated using the leave-one-out Jackknife method. The tumor volume after therapy was predicted on the basis of pretherapy PET/CT imaging and PBPK/PD modeling. Results: The relative deviation of the predicted and measured tumor volume for PSMA-positive tumor cells (6 wk after therapy) was 1% ± 40%, excluding 1 patient (prostate-specific antigen-negative) from the population. The radiosensitivity for the prostate-specific antigen-positive patients was determined to be 0.0172 ± 0.0084 Gy-1Conclusion: To our knowledge, the proposed method is the first attempt to solely use PET/CT and modeling methods to predict the PSMA-positive tumor volume after RLT. Internal validation shows that this is feasible with an acceptable accuracy. Improvement of the method and external validation of the model is ongoing.


Asunto(s)
Modelos Biológicos , Tomografía Computarizada por Tomografía de Emisión de Positrones , Neoplasias de la Próstata Resistentes a la Castración/metabolismo , Neoplasias de la Próstata Resistentes a la Castración/radioterapia , Antígenos de Superficie/metabolismo , Glutamato Carboxipeptidasa II/metabolismo , Humanos , Procesamiento de Imagen Asistido por Computador , Ligandos , Lutecio/uso terapéutico , Masculino , Neoplasias de la Próstata Resistentes a la Castración/diagnóstico por imagen , Radioisótopos/uso terapéutico , Distribución Tisular , Resultado del Tratamiento , Carga Tumoral/efectos de la radiación
3.
J Nucl Med ; 58(3): 445-450, 2017 03.
Artículo en Inglés | MEDLINE | ID: mdl-27660138

RESUMEN

Prostate-specific membrane antigen (PSMA)-targeted radioligand therapy is increasingly used in metastatic castration-resistant prostate cancer. We aimed to estimate the absorbed doses for normal organs and tumor lesions using 177Lu-PSMA I&T (I&T is imaging and therapy) in patients undergoing up to 4 cycles of radioligand therapy. Results were compared with pretherapeutic Glu-NH-CO-NH-Lys-(Ahx)-[68Ga(HBEDCC)] (68Ga-PSMA-HBED-CC) PET. Methods: A total of 34 cycles in 18 patients were analyzed retrospectively. In 15 patients the first, in 9 the second, in 5 the third, and in 5 the fourth cycle was analyzed, respectively. Whole-body scintigraphy was performed at least between 30-120 min, 24 h, and 6-8 d after administration. Regions of interest covering the whole body, organs, and up to 4 tumor lesions were drawn. Organ and tumor masses were derived from pretherapeutic 68Ga-PSMA-HBED-CC PET/CT. Absorbed doses for individual cycles were calculated using OLINDA/EXM. SUVs from pretherapeutic PET were compared with absorbed doses and with change of SUV. Results: The mean whole-body effective dose for all cycles was 0.06 ± 0.03 Sv/GBq. The mean absorbed organ doses were 0.72 ± 0.21 Gy/GBq for the kidneys; 0.12 ± 0.06 Gy/GBq for the liver; and 0.55 ± 0.14 Gy/GBq for the parotid, 0.64 ± 0.40 Gy/GBq for the submandibular, and 3.8 ± 1.4 Gy/GBq for the lacrimal glands. Absorbed organ doses were relatively constant among the 4 different cycles. Tumor lesions received a mean absorbed dose per cycle of 3.2 ± 2.6 Gy/GBq (range, 0.22-12 Gy/GBq). Doses to tumor lesions gradually decreased, with 3.5 ± 2.9 Gy/GBq for the first, 3.3 ± 2.5 Gy/GBq for the second, 2.7 ± 2.3 Gy/GBq for the third, and 2.4 ± 2.2 Gy/GBq for the fourth cycle. SUVs of pretherapeutic PET moderately correlated with absorbed dose (r = 0.44, P < 0.001 for SUVmax; r = 0.43, P < 0.001 for SUVmean) and moderately correlated with the change of SUV (r = 0.478, P < 0.001 for SUVmax, and r = 0.50, P < 0.001 for SUVmean). Conclusion: Organ- and tumor-absorbed doses for 177Lu-PSMA I&T are comparable to recent reports and complement these with information on an excellent correlation between the 4 therapy cycles. With the kidneys representing the critical organ, a cumulative activity of 40 GBq of 177Lu-PSMA I&T appears to be safe and justifiable. The correlation between pretherapeutic SUV and absorbed tumor dose emphasizes the need for PSMA-ligand PET imaging for patient selection.


Asunto(s)
Absorción de Radiación , Dipéptidos/farmacocinética , Dipéptidos/uso terapéutico , Compuestos Heterocíclicos con 1 Anillo/farmacocinética , Compuestos Heterocíclicos con 1 Anillo/uso terapéutico , Tomografía de Emisión de Positrones/métodos , Neoplasias de la Próstata Resistentes a la Castración/diagnóstico por imagen , Neoplasias de la Próstata Resistentes a la Castración/radioterapia , Anciano , Humanos , Lutecio , Masculino , Tasa de Depuración Metabólica , Metástasis de la Neoplasia , Tratamientos Conservadores del Órgano/métodos , Especificidad de Órganos , Antígeno Prostático Específico , Radiofármacos/farmacocinética , Radiofármacos/uso terapéutico , Dosificación Radioterapéutica , Estudios Retrospectivos , Distribución Tisular , Resultado del Tratamiento , Recuento Corporal Total
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA