Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Bases de datos
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
J Radiol Prot ; 41(2)2021 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-33498015

RESUMEN

The objective of this study was to estimate the risk of radiation-induced injury to the organs due to ionizing radiation following breast screening recommendations employing digital breast tomosynthesis (DBT) and digital mammography (DM). Using the Monte Carlo method, absorbed doses in the tissues and organs were calculated on an adult female phantom, considering two-view craniocaudal (CC) and mediolateral oblique (MLO) projections for each breast. The results showed differences in the total effective risk due to DM (CC + MLO) and DBT (CC + MLO) examinations in Brazil, ranging from 20.73 cases 10-5(DM) to 27.19 cases 10-5(DBT). Significant differences were also observed in the total effective risk of cancer incidence in the lungs due to DM (CC + MLO) and DBT (CC + MLO), ranging from 1.75×10-01cases 10-5(DM) to 1.76×10-01cases 10-5(DBT). The results indicate that the total effective risk of incidence should be considered as an additional parameter for the evaluation of DBT or DBT + DM program performance.


Asunto(s)
Neoplasias de la Mama , Neoplasias Inducidas por Radiación , Adulto , Mama/diagnóstico por imagen , Neoplasias de la Mama/diagnóstico por imagen , Detección Precoz del Cáncer , Femenino , Humanos , Mamografía , Tamizaje Masivo , Neoplasias Inducidas por Radiación/epidemiología , Neoplasias Inducidas por Radiación/etiología
2.
Health Phys ; 121(1): 18-29, 2021 07 01.
Artículo en Inglés | MEDLINE | ID: mdl-33867436

RESUMEN

ABSTRACT: The influence of the angular deviation of the tube during digital breast tomosynthesis (DBT) acquisition to the dose in the examined breast and in other organs and tissues is not well known. In this work, the Monte Carlo method was used with an adult female virtual anthropomorphic phantom to investigate the impact of this angular variation on the breast dose. The absorbed dose in the examined breast was normalized by the air kerma, which resulted in an absorbed dose coefficient (DT/Kair) for the breast. The absorbed dose in each organ was normalized by the glandular dose in the breast, resulting in the relative organ dose (ROD). An adult female virtual anthropomorphic phantom (FSTA_M50_H50) was incorporated into a scenario containing tomosynthesis equipment with Mo/Mo, Mo/Rh, and W/Rh target/filter combinations and tube voltages of 28 kV. The comparison between the results of the simulations considering digital mammography (DM) and DBT data showed that the DT/Kair values for the examined breast obtained with the DBT parameters were up to 24 times higher than with the DT/Kair obtained with DM parameters. A DT/Kair of 0.97 × 10-1 mGy mGy-1 was obtained in a DBT exam of the right breast. Considering the other organs, the highest ROD values were observed in the thyroid (6.45 × 10-4), eyes (3.87 × 10-4), liver (1.95 × 10-5), and eye lenses (3.21 × 10-3). A variation in the absorbed dose values for the breast and other organs was observed for all projections different from 0°.


Asunto(s)
Mamografía , Radiometría , Mama/diagnóstico por imagen , Femenino , Humanos , Método de Montecarlo , Fantasmas de Imagen , Dosis de Radiación , Radiometría/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA