Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros

Bases de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Bull Natl Res Cent ; 46(1): 275, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36474930

RESUMEN

Background: There have been suggestions that hematologic abnormalities in COVID-19 are linked with the progression and severity of diseases and mortality. Lymphopenia, sepsis, and thrombocytopenia were highly reported in patients with COVID-19. This study investigated the significance of hematologic abnormalities in patients with COVID-19 in Lagos, Nigeria, and its potential as a diagnostic tool for COVID-19 severity. Results: This was a retrospective observational study with a total of 340 patients with COVID-19 (236 patients included in the analysis). These patients were categorized into two groups, comprising 71 patients with severe COVID-19 (SCP) and 165 patients with non-severe COVID-19 (NSCP). The majority were males in both categories (SCP 74.6% and NSCP 63.6%). The mean ± SD ages for SCP and NSCP were 52.28 ± 16.87 and 42.44 ± 17.18 years, respectively. The SCP (52.1%) and NSCP (20.0%) had underlying health conditions. The SCP exhibited significantly higher neutrophil counts (P < 0.05) and significantly lower mean hemoglobin, red blood cell (RBC), packed cell volume (PCV), and lymphocyte values (P < 0.05). Anemia and lymphocytopenia were more prominent in the SCP group than in the NSCP group (P < 0.05). Hemoglobin, RBC, PCV, and lymphocytes were inversely correlated with age-group in the SCP, while only lymphocytes and platelets were inversely correlated with age-group in the NSCP. The highest area under the ROC curve (AUC) for neutrophils was 0.739 with a sensitivity of 62.0% and specificity of 80.0%, while white blood cells had an AUC of 0.722 with a sensitivity of 73.2% and specificity of 61.2%. The AUC for neutrophil-lymphocyte ratio (NLR) was 0.766 with a sensitivity of 63.3% and specificity of 83.5%, while that for the platelet-lymphocyte ratio (PLR) was 0.695 with a sensitivity and specificity of 61.7% and 77.8%. Conclusions: COVID-19 affected the levels of hemoglobin, RBC, PCV, and lymphocytes in the blood, and the differences were significant between the SCP and NSCP. The significant changes in neutrophil and lymphocyte counts may be useful in the prognosis and management of COVID-19 severity in hospital settings. Furthermore, NLR and PLR may be used in the prognosis and management of severe COVID-19 infection, as well as provide an objective basis for early identification and management in low-resource settings.

2.
Afr J Lab Med ; 2(1): 68, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-29043166

RESUMEN

BACKGROUND: The use of real-time Polymerase chain reaction (PCR) technology options is increasing in resource-limited settings because they are faster, improve assay sensitivity, have higher throughput, larger dynamic ranges and reduced rates of contamination. In 2010, UNAIDS ranked Nigeria as the second highest population of people living with HIV and AIDS (2.98 million people) in the world. OBJECTIVE: The objective of this study was to compare the analytical performances of the Amplicor HIV-1 Monitor (version 1.5) and the COBAS Ampliprep/Taqman (version 2.0) used in monitoring HIV disease progression in HIV-infected individuals. METHOD: In a cross-sectional study, HIV-1 RNA values obtained with the Amplicor HIV-1 monitor version 1.5 were compared with those of the COBAS/Ampliprep TaqMan HIV-1 version 2.0 in a routine clinical setting. Between May and November 2011, 176 plasma samples collected were analysed in parallel using both techniques. Data analysis was done using statgraphics Centurion XVI and Medcalc version 12.0. RESULT: The correlation coefficient for the two assays was 0.83 and the level of agreement using a Bland-Altman plot was 94.2%. CONCLUSION: These findings suggest that the results from the two methods were comparable, hence the COBAS/Ampliprep Taqman version 2.0 is recommended for high-volume laboratories.

3.
Afr J Lab Med ; 1(1): 18, 2012.
Artículo en Inglés | MEDLINE | ID: mdl-29062734

RESUMEN

ISSUES: Quality-management systems (QMS) are uncommon in clinical laboratories in Nigeria, and until recently, none of the nation's 5 349 clinical laboratories have been able to attain the certifications necessary to begin the process of attaining international accreditation. Nigeria's Human Virology Laboratory (HVL), however, began implementation of a QMS in 2006, and in 2008 it was determined that the laboratory conformed to the requirements of ISO 9001:2000 (now 2008), making it the first diagnostic laboratory to be certified in Nigeria. The HVL has now applied for the World Health Organization (WHO) accreditation preparedness scheme. The experience of the QMS implementation process and the lessons learned therein are shared here. DESCRIPTION: In 2005, two personnel from the HVL spent time studying quality systems in a certified clinical laboratory in Dakar, Senegal. Following this peer-to-peer technical assistance, several training sessions were undertaken by HVL staff, a baseline assessment was conducted, and processes were established. The HVL has monitored its quality indicators and conducted internal and external audits; these analyses (from 2007 to 2009) are presented herein. LESSONS LEARNED: Although there was improvement in the pre-analytical and analytical indicators analysed and although data-entry errors decreased in the post-analytical process, the delay in returning laboratory test results increased significantly. There were several factors identified as causes for this delay and all of these have now been addressed except for an identified need for automation of some high-volume assays (currently being negotiated). Internal and external audits showed a trend of increasing non-conformities which could be the result of personnel simply becoming lax over time. Application for laboratory accreditation, however, could provide the renewed vigour needed to correct these non-conformities. RECOMMENDATION: This experience shows that sustainability of the QMS at present is a cause for concern. However, the tiered system of accreditation being developed by WHO-Afro may act as a driving force to preserve the spirit of continual improvement.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA