Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Pediatr Cardiol ; 36(4): 835-41, 2015 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-25560736

RESUMEN

Thrombotic occlusion of a modified Blalock-Taussig (BT) shunt is rare, leading to life-threatening hypoxemia. Rescue percutaneous interventions may allow recanalization of the systemic-to-pulmonary shunt but data on large patients' scales are lacking. We aimed to describe safety and effectiveness of catheter-based interventions to restore modified BT shunt patency. All patients who attempted transcatheter intervention for thrombotic occlusion of a modified BT shunt at our Institution from 1994 to 2014 were reviewed. Characteristics, management, and outcomes of the 28 identified patients were analyzed. Thirty-three procedures were performed at a median age of 0.6 years old (range 0.03-32.1 years) and a median weight of 5.8 kg (range 2.2-82 kg). Percutaneous intervention consisted in 33 balloon angioplasty (100 %) and 14 stent implantations (42.4 %). Thrombolytic agents were also used in 6.1 % cases. No peri-procedural death occurred but complications were observed in five patients (15.2 %), including one catheter-induced transient complete atrioventricular block, one cardiac tamponade, and one massive thrombo-embolic stroke. Early procedural success was obtained in 28 patients (84.8 %) and remained long-lasting in 26 patients (78.8 %). A young age and a low body-weight at the time of the procedure were significantly associated with procedural failure (p = 0.0364 and p = 0.0247, respectively). Although technically challenging and carrying potential major complications, transcatheter intervention can be considered as an efficient rescue strategy to restore patency in case of thrombotic obstruction of a modified BT shunt.


Asunto(s)
Angioplastia de Balón/métodos , Procedimiento de Blalock-Taussing/efectos adversos , Cateterismo Cardíaco/métodos , Fibrinolíticos/uso terapéutico , Stents , Trombosis/terapia , Adolescente , Adulto , Procedimiento de Blalock-Taussing/métodos , Niño , Preescolar , Femenino , Humanos , Lactante , Masculino , Complicaciones Posoperatorias/terapia , Trombosis/tratamiento farmacológico , Trombosis/etiología , Resultado del Tratamiento , Adulto Joven
2.
Eur Heart J ; 29(17): 2133-40, 2008 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-18385120

RESUMEN

AIMS: We evaluated the accuracy of 64-slice computed tomography (CT) to identify ischaemic aetiology of heart failure (IHF). METHODS AND RESULTS: Ninety-three consecutive patients in sinus rhythm with dilated cardiomyopathy but without suspicion of coronary artery disease (CAD) were enrolled when admitted for angiography. Accuracy of CT to detect significant stenosis (>50% lumen narrowing) was compared with quantitative coronary angiography. IHF was defined as a significant stenosis on left main or proximal left anterior descending artery or two or more vessels. Forty-three out of 1395 segments (3%) were heavily calcified and excluded. CT correctly assessed 103 of 142 (73%) significant stenosis and identified 46 of 50 (92%) patients without and 42 of 43 (98%) patients with CAD, 60 of 62 (97%) patients without and 28 of 31 (90%) patients with IHF. Overall, accuracy, sensitivity, specificity, positive predictive value, and negative predictive value of CT for identifying CAD by segment was 96, 73, 99, 92, and 97%, respectively; by patient was 95, 98, 92, 91, and 98%, respectively; and for identifying IHF was 95, 90, 97, 93, and 95%, respectively. CONCLUSION: Non-invasive 64-slice CT assessment of the extent of CAD may offer a valid alternative to angiography for the diagnosis of IHF.


Asunto(s)
Estenosis Coronaria/diagnóstico por imagen , Insuficiencia Cardíaca/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Anciano , Calcinosis/diagnóstico por imagen , Cardiomiopatía Dilatada/diagnóstico por imagen , Cardiomiopatía Dilatada/etiología , Angiografía Coronaria/métodos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Sensibilidad y Especificidad
3.
J Heart Valve Dis ; 16(3): 216-24, 2007 May.
Artículo en Inglés | MEDLINE | ID: mdl-17578038

RESUMEN

BACKGROUND AND AIM OF THE STUDY: The study aim was to compare, prospectively, the planimetry of aortic stenosis on 64-slice computed tomography (CT), with the area calculated by Doppler transthoracic echocardiography (TTE) in symptomatic patients evaluated before potential aortic valve replacement. METHODS: Fifty-two consecutive patients (27 males, 25 females; mean age 74 +/- 10 years) admitted to the authors' institution during 2005 were evaluated with 64-slice CT and Doppler TTE. The time interval between the two evaluations was 2 +/- 1 weeks. Planimetry of the anatomic orifice area (AOA) drawn on 64-slice CT was compared to the effective area determined by Doppler TTE by Bland and Altman analysis, and the anatomic area threshold value corresponding to a significant effective aortic stenosis (50.75 cm2) was determined by receiver operating characteristic (ROC) analysis. RESULTS: The aortic orifice area measured by 64-slice CT correlated well with the effective area (r = 0.76; p <0.0001), but was significantly greater, with a systematic overestimation (0.132 cm(2)) and a variability of 0.239 cm(2). There was good agreement between planimetry determined by two independent radiologists (difference = 0.002, variability = 0.115 cm(2)). ROC analysis showed that a threshold value of 0.95 cm(2) as measured by 64-slice CT planimetry identifies significant aortic stenosis with sensitivity, specificity, accuracy, positive and negative predictive values of 82%, 77%, 81%, 91% and 59%, respectively. CONCLUSION: 64-slice CT is a reproducible and reliable non-invasive method to evaluate aortic valve stenosis compared to the reference method of Doppler TTE. Indeed, the CT approach could replace the latter evaluation when measurements used in the continuity equation are inadequate.


Asunto(s)
Estenosis de la Válvula Aórtica/diagnóstico por imagen , Ecocardiografía Doppler , Tomografía Computarizada por Rayos X/métodos , Anciano , Válvula Aórtica/diagnóstico por imagen , Calcinosis/diagnóstico por imagen , Femenino , Humanos , Masculino , Valor Predictivo de las Pruebas , Estudios Prospectivos , Curva ROC , Sensibilidad y Especificidad
4.
J Am Coll Cardiol ; 45(11): 1826-31, 2005 Jun 07.
Artículo en Inglés | MEDLINE | ID: mdl-15936614

RESUMEN

OBJECTIVES: We sought to find a non-invasive alternative to conventional coronary angiography (CCA) for serial detection and follow-up of coronary stenosis due to cardiac allograft vasculopathy in heart transplant patients. BACKGROUND: Cardiac allograft vasculopathy is the main factor limiting long-term success of heart transplantation. It is usually detected by CCA. Multislice computed tomography (MSCT) coronary angiography has recently proven effective for the diagnosis of coronary stenosis in non-transplant patients. METHODS: Fifty-three consecutive heart transplant patients underwent MSCT within 24 h before or after their annual routine CCA. Only angiographic segments >1.5 mm were considered for analysis; the coronary arterial tree was divided into nine segments. Three patients were excluded because of technical failure. RESULTS: Of the 450 angiographic coronary segments, 432 (96%) were evaluable by MSCT. Of the nine coronary stents in seven patients, only three, including one intrastent restenosis, were correctly evaluated by MSCT, and two intrastent restenoses were missed. Complete analysis of the coronary tree was possible for 44 (88%) of the 50 patients. For detection of coronary stenosis >50%, sensitivity was 83%, specificity 95%, positive predictive value 71%, negative predictive value 95%, and accuracy 93%. In the 22 patients with strictly normal MSCT, no stenosis was found by CCA. CONCLUSIONS: Our study suggests the following guidelines already applied in our institution: 16-slice MSCT can replace CCA in de novo heart transplant patients and patients with strictly normal MSCT at follow-up. Significant wall or lumen changes observed on annual MSCT or stents require further investigation by CCA.


Asunto(s)
Angiografía Coronaria/métodos , Estenosis Coronaria/diagnóstico por imagen , Vasos Coronarios/patología , Trasplante de Corazón/efectos adversos , Tomografía Computarizada por Rayos X/métodos , Adulto , Humanos , Masculino , Persona de Mediana Edad , Sensibilidad y Especificidad , Trasplante Homólogo
5.
Am J Cardiol ; 98(7): 871-6, 2006 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-16996865

RESUMEN

The present study assessed 64-slice computed tomographic accuracy to quantify minimal lumen area (MLA) and determine lesion severity in intermediate stenosis by angiography compared with intravascular ultrasound (IVUS). Sixty-four-slice computed tomography (CT) has been shown to be effective in coronary stenotic assessment by visual estimation compared with angiography. However, angiography is not an accurate gold standard for intermediate stenotic quantification compared with IVUS. Forty patients (54 lesions) with 30% to 70% coronary stenosis by angiography in a major coronary branch were included. All patients underwent quantitative angiography, retrospective electrocardiographically gated 64-slice CT (Siemens), and IVUS (40-MHz Atlantis; Boston Scientific). MLA was manually traced by 2 blinded and independent operators on 64-slice computed tomographic cross-sectional reconstruction and compared with IVUS MLA. A lesion was considered significant if the MLA was

Asunto(s)
Estenosis Coronaria/patología , Vasos Coronarios/patología , Tomografía Computarizada por Rayos X/métodos , Ultrasonografía Intervencional , Angiografía Coronaria , Electrocardiografía , Humanos , Procesamiento de Imagen Asistido por Computador , Persona de Mediana Edad , Variaciones Dependientes del Observador , Sensibilidad y Especificidad , Índice de Severidad de la Enfermedad
6.
Am J Cardiol ; 96(4): 524-8, 2005 Aug 15.
Artículo en Inglés | MEDLINE | ID: mdl-16098305

RESUMEN

We aimed to quantify ambiguous coronary stenosis using the minimal lumen area with 16-slice computed tomography compared with intravascular ultrasound. The sensitivity, specificity, and accuracy for significant lesion classification was 68%, 86%, and 78%, respectively. The correlation between intravascular ultrasound and CT minimal lumen area was r = 0.73 (p <0.001), and the 95% confidence interval for CT measurement was -72% to +56%.


Asunto(s)
Estenosis Coronaria/diagnóstico por imagen , Vasos Coronarios/diagnóstico por imagen , Endosonografía , Tomografía Computarizada por Rayos X/métodos , Anciano , Angiografía Coronaria , Femenino , Humanos , Persona de Mediana Edad , Reproducibilidad de los Resultados , Estudios Retrospectivos , Sensibilidad y Especificidad , Índice de Severidad de la Enfermedad
7.
World J Pediatr Congenit Heart Surg ; 6(1): 39-45, 2015 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-25548342

RESUMEN

BACKGROUND: Closure of tubular patent ductus arteriosus remains a challenging procedure. Anecdotal use of Amplatzer Vascular Plug IV for tubular ductus closure has been reported but feasibility and safety in a consecutive patients' series remain unknown. METHODS: We performed a monocenter prospective study at the Marie Lannelongue Hospital in Paris, France. From 2009 to 2014, a total of 47 patients (39 infants, 3 children, and 5 adults) underwent ductus closure with the Plug IV. RESULTS: Ductus morphology was a type E in 34 (72.3%) patients and a type C in 13 (27.7%) patients. Ductus closure occurred in 39 (83.0%) infants at a median age of seven months (range: 3-23 months) and a median weight of 6.9 kg (range: 4.1-17.0 kg). A past history of prematurity and very low birth weight was found in 33 (70.2%) of them. Twelve (25.5%) patients had pulmonary hypertension. Mean Plug IV diameter was 1.9 ± 0.1 mm larger than the mean maximal ductus diameter. Early complete closure of the ductus was obtained in all patients. Early migration of an undersized Plug IV occurred in one (2.1%) patient and was suitable for percutaneous device retrieval. After a mean follow-up of 3.4 ± 1.4 years, all patients are alive and asymptomatic, no late complication occurred. CONCLUSION: Transcatheter closure of tubular ductus with the Amplatzer Vascular Plug IV can be safe and effective, with a 100% early occlusion rate. This device, suitable for a 4F sheath, is a new alternative for tubular ductus closure in low-body-weight infants.


Asunto(s)
Cateterismo Cardíaco , Conducto Arterioso Permeable/terapia , Prótesis e Implantes , Adulto , Niño , Estudios de Factibilidad , Femenino , Estudios de Seguimiento , Humanos , Lactante , Masculino , Seguridad del Paciente , Estudios Prospectivos , Resultado del Tratamiento
8.
Am J Cardiol ; 92(7): 849-52, 2003 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-14516892

RESUMEN

Nonsignificant coronary artery plaque rupture or erosion may be the origin of acute myocardial infarction (AMI). The aim of our study was to assess the ability of multislice computed tomography (MSCT) to detect coronary plaques responsible for near normal coronary angiography AMI. Eight patients with presentation of AMI and no significant coronary narrowing by angiography were enrolled. Two groups were defined: (1) true AMI and (2) myocarditis. MSCT was able to detect nonsignificant coronary soft plaques responsible for AMI and has provided information on plaque volume, eccentricity, and density. In patients with myocarditis, there was no evidence of plaque.


Asunto(s)
Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Infarto del Miocardio/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Adulto , Anciano , Enfermedad de la Arteria Coronaria/complicaciones , Electrocardiografía , Femenino , Humanos , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Infarto del Miocardio/etiología , Miocarditis/complicaciones , Miocarditis/diagnóstico , Ultrasonografía Intervencional
9.
Am J Cardiol ; 94(1): 99-104, 2004 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-15219516

RESUMEN

We compared 16-slice computed tomography with intravascular ultrasound in the detection of unstable component characteristics of nonstenotic plaque responsible for acute coronary syndrome. Computed tomography accurately assessed plaque eccentricity, calcification, and remodeling, and intraplaque hypodensity correlated with intravascular ultrasound echolucent area.


Asunto(s)
Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Ultrasonografía Intervencional/métodos , Adulto , Anciano , Angiografía Coronaria/métodos , Estenosis Coronaria/diagnóstico por imagen , Femenino , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas
10.
Arch Cardiovasc Dis ; 107(2): 122-32, 2014 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-24560920

RESUMEN

This review aims to describe the past history, present techniques and future directions in transcatheter treatment of patent ductus arteriosus (PDA). Transcatheter PDA closure is the standard of care in most cases and PDA closure is indicated in any patient with signs of left ventricular volume overload due to a ductus. In cases of left-to-right PDA with severe pulmonary arterial hypertension, closure may be performed under specific conditions. The management of clinically silent or very tiny PDAs remains highly controversial. Techniques have evolved and the transcatheter approach to PDA closure is now feasible and safe with current devices. Coils and the Amplatzer Duct Occluder are used most frequently for PDA closure worldwide, with a high occlusion rate and few complications. Transcatheter PDA closure in preterm or low-bodyweight infants remains a highly challenging procedure and further device and catheter design development is indicated before transcatheter closure is the treatment of choice in this delicate patient population. The evolution of transcatheter PDA closure from just 40 years ago with 18F sheaths to device delivery via a 3F sheath is remarkable and it is anticipated that further improvements will result in better safety and efficacy of transcatheter PDA closure techniques.


Asunto(s)
Cateterismo Cardíaco , Conducto Arterioso Permeable/terapia , Cateterismo Cardíaco/historia , Cateterismo Cardíaco/instrumentación , Cateterismo Cardíaco/tendencias , Difusión de Innovaciones , Conducto Arterioso Permeable/diagnóstico , Conducto Arterioso Permeable/historia , Conducto Arterioso Permeable/fisiopatología , Diseño de Equipo , Predicción , Hemodinámica , Historia del Siglo XX , Historia del Siglo XXI , Humanos , Resultado del Tratamiento
11.
Circ Cardiovasc Interv ; 7(6): 837-43, 2014 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-25423959

RESUMEN

BACKGROUND: Data are needed on the safety and efficacy of device closure of large atrial septal defects. METHODS AND RESULTS: Between 1998 and 2013, 336 patients (161 children <15 years) with large, isolated, secundum atrial septal defects (balloon-stretched diameter ≥34 mm in adults or echocardiographic diameter >15 mm/m(2) in children) were managed using the Amplatzer device, at the Marie Lannelongue Hospital. Transthoracic echocardiographic guidance was used starting in 2005 (n=219; 65.2%). Balloon-stretched diameter was >40 mm in 36 adults; mean values were 37.6±3.3 mm in other adults and 26.3±6.3 mm/m(2) in children. Amplatzer closure was successful in 311 (92.6%; 95% confidence interval, 89%-95%) patients. Superior and posterior rim deficiencies were more common in failed than in successful procedures (superior, 24.0% versus 4.8%; P=0.002; and posterior, 32.0% versus 4.2%; P<0.001). Device migration occurred in 4 adults (2 cases each of surgical and transcatheter retrieval); in the 21 remaining failures, the device was unreleased and withdrawn. After a median follow-up of 10.0 years (2.5-17 years), all patients were alive with no history of late complications. CONCLUSIONS: Closure of large atrial septal defects using the Amplatzer device is safe and effective in both adults and children. Superior and posterior rim deficiencies are associated with procedural failure. Closure can be performed under transthoracic echocardiographic guidance in experienced centers. Early device migration is rare and can be safely managed by device extraction. Long-term follow-up showed no deaths or major late complications in our population of 311 patients.


Asunto(s)
Cateterismo Cardíaco/instrumentación , Defectos del Tabique Interatrial/terapia , Dispositivo Oclusor Septal , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Cateterismo Cardíaco/efectos adversos , Niño , Preescolar , Remoción de Dispositivos , Ecocardiografía Transesofágica , Estudios de Factibilidad , Femenino , Migración de Cuerpo Extraño/etiología , Migración de Cuerpo Extraño/terapia , Defectos del Tabique Interatrial/diagnóstico , Humanos , Masculino , Persona de Mediana Edad , Paris , Estudios Prospectivos , Diseño de Prótesis , Falla de Prótesis , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento , Adulto Joven
12.
EuroIntervention ; 6(6): 717-21, 2011 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-21205594

RESUMEN

AIMS: Conventional quantitative coronary angiography approaches are limited to quantify complex aorto-ostial stenosis. Multislice CT was able to detect and classify coronary plaques, compared with intravascular ultrasound (IVUS). The aim of the present study was to determine the accuracy of multislice computed tomography (CT) in addition to conventional angiography to identify aorto-ostial coronary stenosis characteristics before revascularisation. METHODS AND RESULTS: Patients with coronary ostial stenosis were selected for the study. All patients had selective coronary angiography and retrospectively ECG-gated multislice CT (Siemens AG, Munich, Germany). IVUS was performed in patients with ambiguous ostial stenosis revealed by angiography. Forty significant aorto-ostial lesions (38 patients) were analysed by two independent observers in comparison with an expert consensus blinded or not to the coronary CT data sets. Using CT in addition to angiography permitted observers to obtain a strong agreement for assessment of calcified lesions (kappa value 0.75), a good agreement for aortic plaques location and ideal stent position in aorto-ostial coronary stenosis. CONCLUSIONS: This study shows that CT associated with an angiogram allows a better identification of aorto-ostial plaques morphology and ideal stent position in aorto-ostial coronary stenosis before angioplasty.


Asunto(s)
Angioplastia Coronaria con Balón , Angiografía Coronaria/métodos , Estenosis Coronaria/diagnóstico por imagen , Tomografía Computarizada por Rayos X , Anciano , Anciano de 80 o más Años , Angioplastia Coronaria con Balón/instrumentación , Estenosis Coronaria/terapia , Electrocardiografía , Femenino , Francia , Humanos , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Valor Predictivo de las Pruebas , Estudios Prospectivos , Reproducibilidad de los Resultados , Índice de Severidad de la Enfermedad , Stents , Ultrasonografía Intervencional
14.
J Am Coll Cardiol ; 49(11): 1178-85, 2007 Mar 20.
Artículo en Inglés | MEDLINE | ID: mdl-17367662

RESUMEN

OBJECTIVES: Early evaluation of myocardial viability in acute myocardial infarction is useful to guide therapy. Therefore, we assessed 64-slice computed tomography (CT) immediately after coronary angiography in this setting. BACKGROUND: Recent preliminary studies have shown the promising usefulness of late hyperenhancement multislice computed tomography (MSCT) for non-viability assessment. METHODS: Thirty-six patients admitted for a first acute myocardial infarction had a coronary angiogram early after admission followed by 64-slice CT without iodine reinjection. The 16 segments of the left ventricle depicted by the American Society of Echocardiography were graded: no, subendocardial, or transmural hyperenhancement. No or subendocardial hyperenhancement were expected to reflect viability. Two to 4 weeks later, the same segments' contractility was evaluated at rest. Low-dose dobutamine echocardiography was performed in case of akinetic segment at rest. RESULTS: Mean delay between coronary angiography and MSCT was 24 +/- 11 min (range 7 to 51 min). We compared 576 segments evaluated by each method. Agreement was noted for 560 segments (97%) and disagreement for 16 segments (3%). Thus, 64-slice CT after coronary angiography for an acute myocardial infarction had 98% sensitivity, 94% specificity, 97% accuracy, and 99% positive and 79% negative predictive values for detecting viable myocardial segments at a very early stage of an acute myocardial infarction. On a per-patient analysis, sensitivity, specificity, accuracy, and positive and negative predictive values were 92%, 100%, 94%, and 100% and 85%, respectively. CONCLUSIONS: A 64-slice CT after coronary angiography for an acute myocardial infarction is a promising method for early evaluation of viable myocardium.


Asunto(s)
Dobutamina , Ecocardiografía Doppler/métodos , Infarto del Miocardio/diagnóstico por imagen , Tomografía Computarizada Espiral/métodos , Adulto , Anciano , Anciano de 80 o más Años , Angioplastia Coronaria con Balón/métodos , Estudios de Cohortes , Angiografía Coronaria/métodos , Relación Dosis-Respuesta a Droga , Electrocardiografía , Femenino , Estudios de Seguimiento , Humanos , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Contracción Miocárdica/fisiología , Infarto del Miocardio/terapia , Probabilidad , Medición de Riesgo , Sensibilidad y Especificidad , Volumen Sistólico , Función Ventricular Izquierda/fisiología
15.
J Am Coll Cardiol ; 48(10): 1929-34, 2006 Nov 21.
Artículo en Inglés | MEDLINE | ID: mdl-17112979

RESUMEN

OBJECTIVES: The goal of this study was to evaluate the diagnostic accuracy of 64-slice computed tomography (CT) to identify coronary artery disease (CAD) in patients with complete left bundle branch block (LBBB). BACKGROUND: Left bundle branch block increases risk of cardiac mortality, and prognosis is primarily determined by the underlying coronary disease. Non-invasive stress tests have limited performance, and conventional coronary angiography (CCA) is usually required. METHODS: Sixty-six consecutive patients with complete LBBB and sinus rhythm admitted for CCA were enrolled. Computed tomography was performed 3 +/- 3.9 days before CCA. The accuracy of 64-slice CT to detect significant stenosis (>50% lumen narrowing) was compared with quantitative coronary angiography. All segments were analyzed regardless of image quality from coronary calcification or motion artifacts. Results were analyzed by patient and by coronary segment (990) using the American Heart Association 15-segment model. RESULTS: Lower heart rates were associated with improved image quality. Computed tomography correctly identified 35 of 37 (95%) patients without significant stenosis and 28 of 29 (97%) patients with significant stenosis on CCA. Computed tomography correctly assessed 68 of 94 (72%) significant stenosis. Overall, accuracy, sensitivity, specificity, positive predictive value, and negative predictive value of 64-slice CT for identifying CAD by patient was 95%, 97%, 95%, 93%, and 97%, respectively, and by segment was 97%, 72%, 99%, 91%, and 97%, respectively. CONCLUSIONS: In a routine clinical practice, 64-slice CT detects with excellent accuracy a significant CAD in patients with complete LBBB. A normal CT in this clinical setting is a robust tool to act as a filter and avoid invasive diagnostic procedures.


Asunto(s)
Bloqueo de Rama/complicaciones , Estenosis Coronaria/diagnóstico por imagen , Estenosis Coronaria/etiología , Tomografía Computarizada por Rayos X/métodos , Anciano , Angiografía Coronaria , Estenosis Coronaria/fisiopatología , Femenino , Frecuencia Cardíaca , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Sensibilidad y Especificidad , Tomografía Computarizada por Rayos X/normas
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA