Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 21
Filtrar
1.
J Arthroplasty ; 39(6): 1569-1576, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38749600

RESUMEN

BACKGROUND: Periprosthetic joint infection (PJI) after total knee arthroplasty (TKA) is a devastating complication. Intrawound vancomycin powder has been shown to reduce infection rates in spine surgery, but its role in arthroplasty remains controversial. This prospective randomized control trial aimed to evaluate the efficacy of intrawound vancomycin in preventing PJI after primary TKA. METHODS: A total of 1,022 patients were randomized to the study group (n = 507, who received 2 grams intrawound vancomycin powder before arthrotomy closure) or to the control group (n = 515, no local vancomycin) with a minimum follow-up of 12-months. The primary outcome was the incidence of PJI or surgical site infection (SSI). Secondary outcomes included associated minor complications such as stitch abscess, persistent wound drainage, and delayed stitch removal. Other parameters evaluated include reoperation rates and incidences of nephrotoxicity. RESULTS: The overall infection rate in 1,022 patients was 0.66%. There was no significant difference in PJI rate in the study group (N = 1; 0.2%) versus the control group (N = 3; 0.58%), P = .264. Reoperation rates in the study group (N = 4; 0.78%) and control (N = 5; 0.97%), and SSI rates in the study (N = 1; 0.2%) and control groups (N = 2; 0.38%) were comparable. The Vancomycin cohort, however, demonstrated a significantly higher number of minor wound complications (n = 67; 13.2%) compared to the control group (n = 39; 7.56%, P < .05). Subgroup analysis showed diabetics in the study group to also have a higher incidence of minor wound complications (24 [14.1%] versus 10 [6.2%]; P < 05]. Multivariate analyses found that vancomycin use (odds ratio = 1.64) and smoking (odds ratio = 1.85) were associated with an increased risk of developing minor wound complications. No cases of nephrotoxicity were reported. CONCLUSIONS: Intrawound vancomycin powder does not appear to reduce PJI/SSI rate in primary total knee arthroplasties, including high-risk groups. Although safe from a renal perspective, intrawound vancomycin was associated with an increase in postoperative aseptic wound complications. Intrawound vancomycin may not be effective in reducing the rate of PJI in primary TKA.


Asunto(s)
Antibacterianos , Artroplastia de Reemplazo de Rodilla , Infecciones Relacionadas con Prótesis , Infección de la Herida Quirúrgica , Vancomicina , Humanos , Vancomicina/administración & dosificación , Vancomicina/uso terapéutico , Artroplastia de Reemplazo de Rodilla/efectos adversos , Masculino , Femenino , Infecciones Relacionadas con Prótesis/prevención & control , Infecciones Relacionadas con Prótesis/etiología , Infecciones Relacionadas con Prótesis/epidemiología , Anciano , Estudios Prospectivos , Persona de Mediana Edad , Método Doble Ciego , Antibacterianos/administración & dosificación , Infección de la Herida Quirúrgica/prevención & control , Infección de la Herida Quirúrgica/etiología , Infección de la Herida Quirúrgica/epidemiología , Resultado del Tratamiento , Reoperación/estadística & datos numéricos , Prótesis de la Rodilla/efectos adversos , Profilaxis Antibiótica/métodos
2.
Indian J Plast Surg ; 57(4): 270-277, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-39345671

RESUMEN

Introduction Metacarpal fractures are common and have various treatment options, but understanding their morphometry is crucial for optimizing fixation techniques and reducing complications. Accurate assessment of metacarpal anatomy is challenging in conventional radiographs but feasible with computed tomography (CT) scans, which offer precise views. This study aimed to provide accurate anatomical data on metacarpals within an Indian population using CT scans and to compare the results with existing literature. The findings have implications for surgical procedures, including plating, pinning, and intramedullary screw fixation. Materials and Methods This retrospective analysis utilized CT scans of 100 hands, including 50 males and 50 females, from two hospitals in India. Inclusion criteria included complete metacarpal visualization with a slice thickness of 0.6 mm, while exclusion criteria involved trauma, deformity, or underlying pathologies. Various parameters of all metacarpals were measured using RadiAnt DICOM Viewer 2021.1, providing accurate anteroposterior and lateral views. Results Male and female cohorts had mean ages of 38.58 ± 12.02 and 43.60 ± 13.61 years, respectively. The study showed good to excellent reliability in measurements. The 2nd metacarpal was consistently the longest, and the general length pattern was 3rd > 4th > 5th > 1st metacarpal in both genders. Men generally had larger metacarpal dimensions than women, except for intramedullary diameter, which showed minimal sex-related differences. Notably, the medullary cavity's narrowest part was at the 4th metacarpal, and the thumb had the widest intramedullary diameter. Conclusion This study provides valuable anatomical reference data for metacarpals in an Indian population, aiding in optimizing surgical techniques for metacarpal fractures. The 2nd metacarpal consistently stood out as the longest, and men generally had larger metacarpal dimensions than women. These insights into anatomical variations can inform clinical decisions and stimulate further research in this field. However, a larger and more diverse sample would enhance the study's representativeness.

3.
Int Orthop ; 47(7): 1729-1736, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-37186286

RESUMEN

PURPOSE: Patellar resurfacing has long been a contentious subject in TKA with no consensus and the literature yielding disparate results. The aim of this study was to evaluate the long-term functional outcomes and complications of patients undergoing primary TKA without patellar resurfacing (non-resurfacing). METHODS: This study retrospectively analysed 9346 patients who underwent primary manual jig-based TKA without patellar resurfacing at a single high-volume arthroplasty centre between 2010 and 2018. Patients with a minimum three year follow-up irrespective of disease etiology and implant manufacturer were included in the study. Primary outcome was measured using Oxford knee score and patellofemoral Feller score. Secondary outcomes included determining the incidence of patellofemoral complications and re-operation rates following TKA. RESULTS: A total of 8695 knees were eligible for final evaluation having a mean follow-up of 6.6 years. Mean age of the patients was 62.6 (SD-7.5) years with female predominance of (N-6619, 70.8%). The majority of the patients had primary OA (N-8792, 94.1%) with varus deformity (N-8642, 92.46%). Depuy was the most used manufacturer (n = 2592, 26.4%) with the posterior stabilised (N-4127, 44.2%) design being the most predominant. The mean Feller score of the study population was 24.5 (SD = 3) with a majority of patients having good to excellent outcomes (86.95%, N-8424) and mean Oxford knee score was 36.9 (SD-6.9) with a majority of the patients having an OKS greater than 30 (87.1%, N-8133) with anterior knee pain (AKP) reported in only 4.8% patients (N-418). Most common complications included patellar clunk (N-56, 0.7%), traumatic patellar fractures (N-62, 0.8%), quadriceps tendon tear (N-54, 0.7%) and patellar dislocation (N-4, 0.05%) CONCLUSION: Patellar non-resurfacing has no detrimental impact on functional outcomes and incidence of AKP. We conclude that it is a safe, cost-effective and satisfactory approach in primary TKA with no significant complications.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Osteoartritis de la Rodilla , Humanos , Femenino , Masculino , Artroplastia de Reemplazo de Rodilla/efectos adversos , Artroplastia de Reemplazo de Rodilla/métodos , Rótula/cirugía , Estudios Retrospectivos , Osteoartritis de la Rodilla/epidemiología , Osteoartritis de la Rodilla/cirugía , Osteoartritis de la Rodilla/etiología , Resultado del Tratamiento , Articulación de la Rodilla/cirugía , Dolor/etiología
4.
Surg Technol Int ; 412022 07 12.
Artículo en Inglés | MEDLINE | ID: mdl-35830726

RESUMEN

INTRODUCTION: Robotic technology in total knee arthroplasty has been proven to improve accuracy of component positioning, achieve alignment targets, and balance the knee objectively. However, the utility of robotics in correction of severe varus deformities of the knee has not been investigated in detail. The aim of this paper was to establish the utility and describe the technique of robotic-arm assisted total knee arthroplasty (RA-TKA) in achieving pre-balance in severe varus deformities of the knee. MATERIALS AND METHODS: Among the existing Mako (Stryker, Kalamazoo, Michigan) RA-TKA workflows, pre-resection workflow is limited to knees which can be pre-balanced by component positioning according to functional alignment. Mid-resection workflow (distal femur/tibia first) is reserved for complex cases, whereby the extension gap is balanced first. In our experience, both workflows could not achieve pre-balance in severe varus deformities, necessitating the need to develop a novel technique. The ability of the robot to execute precise bone cuts allows for a provisional postero-medial femoral bone cut in flexion, giving access to remove large inaccessible posterior osteophytes and the tight posterior capsule, thus balancing the knee in extension. The flexion gap is subsequently matched to the extension gap by alterations in axial component positioning. CONCLUSION: This novel "enhanced mid-resection workflow" technique establishes the utility of the RA-TKA in balancing severe varus deformities of the knee. We also propose an algorithm which simplifies and helps surgeons choose between the three workflows to pre-balance knees irrespective of the severity of the varus deformity.

5.
Surg Technol Int ; 422022 12 30.
Artículo en Inglés | MEDLINE | ID: mdl-36602185

RESUMEN

INTRODUCTION: Optimal flexion-extension gap balancing is an important factor in outcomes after total knee arthroplasty. Knees with varus deformities are commonly associated with a greater degree of lateral laxity both in extension and flexion. Residual lateral laxity could be encountered by surgeons during component trialling after robotic-assisted total knee arthroplasty (RATKA), necessitating additional medial soft tissue release for a thicker insert. This study describes a new technique of gap assessment during RATKA and we propose a functional alignment based balancing strategy to avoid residual lateral laxity. MATERIALS AND METHODS: This surgical technique was prospectively employed in 105 patients undergoing primary MAKO® (Stryker, Kalamazoo, Michigan) RATKA for osteoarthritis of the knee with varus deformity, between January 2021 and July 2021. Patients included had an initial lateral extension laxity of more than 24mm. Surgical data points collected consisted of characterization of the laxity profile of the knee using the medial and lateral extension and flexion initial gap captures, final gap captures after dynamic balancing with a functional alignment strategy, and residual lateral extension gap laxity in millimeters at the end of implantation. RESULTS: The mean initial lateral extension gap was 25.76mm (standard deviation [SD]=1.47) and the mean lateral flexion gap was 24.4mm (SD=1.94). Balance was achieved in all the patients with a 9 or 11mm insert, with a mean residual lateral laxity of 0.51mm (SD=0.73, range 0-2mm). The majority of patients (n=66, 62.85%) had zero lateral laxity at the end of final implantation while 24 patients (22.8%) had 1mm of residual lateral laxity. CONCLUSION: Residual lateral joint laxity can be avoided consistently and predictably in RATKA cases with initial gap capture of up to 30mm in lateral extension and flexion with this new technique of gap capture and employing various steps of balancing strategy described.

7.
Eur J Orthop Surg Traumatol ; 29(8): 1719-1728, 2019 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-31273493

RESUMEN

BACKGROUND: Despite a sevenfold decline in the number of postoperative nights (21-3) after a total knee arthroplasty (TKA) over the last four decades, predictors of length of stay (LOS) are not fully understood. We attempted to ascertain these factors by analyzing a large cohort of patients. METHODS: Prospectively collected data between January 2016 and March 2017 were retrospectively analyzed at our institute. Charts of 1663 consecutive, simple primary unilateral and bilateral TKAs were reviewed for the LOS excluding staggered bilateral, complex primary and revision knees. STATISTICAL ANALYSIS: Preoperative variables [demographics, cash/credit status, historical, clinical, laboratory findings, Knee Society Function Scores and Oxford Knee Scores (OKSs)] were scrutinized by multivariate regression to identify significant factors affecting LOS and formulate model equations for patients and health caregivers. Results were incorporated into an iOS application, which was tested for accuracy. RESULTS: Among 1524 unilateral and 139 bilateral TKAs, mean LOS was 4.4 and 5.2 days, respectively. Five factors, namely insurance, flexion/hyperextension deformity, preoperative OKS and a rheumatoid etiology, were significantly associated with prolonged LOS in unilateral knees. The impact of these independent variables on LOS could be calculated by: [Formula: see text]For bilateral cases, the only significant variable extending LOS was a low preoperative OKS and the equation is given as follows: [Formula: see text]The iOS-app-predicted LOS and actual LOS were similar (p > 0.05) for 115 prospectively operated knees. CONCLUSION: Poor preoperative OKS, rheumatoid etiology, flexion and hyperextension deformity and delays in insurance affected unilateral TKR LOS, while poor preoperative OKS alone affected LOS in bilateral cases.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/estadística & datos numéricos , Articulación de la Rodilla/fisiopatología , Tiempo de Internación/estadística & datos numéricos , Adulto , Anciano , Anciano de 80 o más Años , Artritis Reumatoide/fisiopatología , Artritis Reumatoide/cirugía , Femenino , Humanos , Seguro de Salud/estadística & datos numéricos , Articulación de la Rodilla/cirugía , Masculino , Persona de Mediana Edad , Osteoartritis de la Rodilla/fisiopatología , Osteoartritis de la Rodilla/cirugía , Periodo Preoperatorio , Rango del Movimiento Articular , Estudios Retrospectivos , Factores de Riesgo , Factores de Tiempo
8.
Indian J Orthop ; 58(10): 1423-1430, 2024 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-39324096

RESUMEN

Purpose: This study investigates the radiological outcomes of robotic-assisted total hip arthroplasty (RATHA) compared to manual total hip arthroplasty (mTHA), addressing the ongoing debate on the effectiveness of RATHA in achieving superior implant positioning accuracy. Methods: A prospective cohort of 212 patients (103 robotic, 109 manual) underwent THA and were evaluated for postoperative radiological outcomes, focusing on the inclination and anteversion angles of the acetabular cup. Outlier prevalence was assessed based on angles outside the defined Lewinnek safe zones. All post-operative measurements were made using the BoneNinja application. Results: High inter-observer and intra-observer reliabilities were observed, validating the measurement accuracy. The mean anteversion and inclination angles in the RATHA cohort were 40.5 ± 1.5 and 24.5 ± 3.1° respectively; and the mTHA cohort were 42.1 ± 4.9 and 24.9 ± 4.5°. There was a statistically significant difference in inclination angles between the two cohorts whereas the anteversion angles showed no difference. Majority of the conventional THRs (N = 72, 55.4%) were placed outside the safe zone for anteversion. The inclination angles revealed a highly significant difference between the cohorts (p < 0.0001), with all the robotic THRs (N = 121, 100%) being placed within the safe zone for inclination, whereas only 70% (N = 91) of the conventional THRs were within the safe zone. 97.5% of RA-THRs were within 3° of the proposed plan, demonstrating high accuracy. Conclusion: RATHA significantly outperforms MTHA in radiological accuracy, achieving precise acetabular cup positioning with minimal outliers. These results advocate for RATHA's adoption in THA to enhance outcome predictability and affirm its reliability and safety over manual methods.

9.
J Orthop ; 52: 107-111, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38440411

RESUMEN

Background: Robotic-assisted total knee replacement (RA-TKR) is a significant advancement in orthopedic surgery, but intra-operative decision-making remains challenging. Pre-operative imaging techniques, particularly CT scans, have gained momentum, providing insights into the patient's anatomy, improving implant positioning and alignment. However, further research is needed to explore their influence on RA-TKR planning and execution. Materials and methods: The hospital based cross-sectional study was conducted in Orthopedics department of Sparsh Speciality Hospital, Bangalore & Sunshine Hospital, Hyderabad. A total of 1020 participants in the age group over 50 years during the study period were included based on convenient sampling. The axial CT images were taken preoperatively and RA-TKA was done for all the patients. Results: The study participant's average age was 64.01 ± 7.13. Out of 1020 patients 259 (24.4%) were males and 761 (74.6%) were females. The median femoral, tibia and Polyethylene predicted and the actual component were same with the side of surgery and BMI. The median femoral predicted actual component was significantly higher among the age category of more than 80 years when compared to other age groups. The median femoral, tibia and Polyethylene predicted was higher in males when compared to females. Conclusion: Pre-operative CT scans enhance RA-TKR procedures by providing precise anatomical insights, enhancing implant placement, and identifying potential issues, improving surgical outcomes and patient satisfaction.

10.
J Orthop Case Rep ; 13(10): 99-104, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37885623

RESUMEN

Introduction: Scapular pseudo-winging caused by ventral osteochondromas is a rare condition that has been reported in only a handful of cases. This case report describes a 21-year-old male patient with scapular pseudo-winging due to ventral osteochondromas of the scapula. This report adds to the limited literature on this topic and highlights the importance of considering ventral osteochondromas as a possible cause of scapular pseudo-winging. Case Report: A 21-year-old male presented with a swelling on his left upper back that had gradually increased in size over the past 10 years. Physical examination revealed a bony hard swelling arising from the medial border of the scapula, with associated scapular pseudo-winging. Diagnostic imaging confirmed the presence of two ventral osteochondromas located on the body of the scapula. Surgical excision was performed to address the patient's cosmetic concerns. Conclusion: This case report highlights the importance of considering ventral osteochondromas as a possible cause of scapular pseudo-winging. It contributes to the existing literature by documenting a rare presentation and providing insights into the clinical course, diagnostic imaging, and surgical management of this condition. By raising awareness among tumor surgeons and orthopedic surgeons, this report may aid in early recognition and appropriate management of scapular pseudo-winging cases caused by ventral osteochondromas. Furthermore, this report expands our understanding of the etiology and treatment options for scapular pseudo-winging, potentially benefiting patients across various clinical specialties. Categories: Oncology, orthopedics.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA