Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 53
Filtrar
Más filtros

País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Europace ; 26(3)2024 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-38530796

RESUMEN

AIMS: Slow conduction (SC) anatomical isthmuses (AIs) are the dominant substrate for monomorphic ventricular tachycardia (VT) in patients with repaired tetralogy of Fallot (rTF). This study aimed to evaluate the utility of automated propagational analysis for the identification of SC-AI in patients with rTF. METHODS AND RESULTS: Consecutive rTF patients undergoing VT substrate characterization were included. Automated isochronal late activation maps (ILAM) were obtained with multielectrode HD Grid Catheter. Identified deceleration zones (DZs) were compared with both SC-AI defined by conduction velocity (CV) (<0.5 m/s) and isthmuses of induced VT for mechanistic correlation. Fourteen patients were included (age 48; p25-75 35-52 years; 57% male), 2 with spontaneous VT and 12 for risk stratification. Nine VTs were inducible in seven patients. Procedure time was 140 (p25-75 133-180) min and mapping time 29.5 (p25-75 20-37.7) min, using a median of 2167 points. All the patients had at least one AI by substrate mapping, identifying a total of 27 (11 SC-AIs). Isochronal late activation maps detected 10 DZs mostly in the AI between ventricular septal defect and pulmonary valve (80%). Five patients had no DZs. A significant negative correlation between number of isochrones/cm and CV was observed (rho -0.87; P < 0.001). Deceleration zones correctly identified SC-AI (90% sensitivity; 100% specificity; 0.94 accuracy) and was related to VT inducibility (P = 0.006). Deceleration zones co-localized to the critical isthmus of induced VTs in 88% of cases. No complications were observed. CONCLUSION: Deceleration zones displayed by ILAM during sinus rhythm accurately identify SC-AIs in rTF patients allowing a safe and short-time VT substrate characterization procedure.


Asunto(s)
Ablación por Catéter , Válvula Pulmonar , Taquicardia Ventricular , Tetralogía de Fallot , Humanos , Masculino , Persona de Mediana Edad , Femenino , Tetralogía de Fallot/cirugía , Frecuencia Cardíaca/fisiología , Arritmias Cardíacas , Ablación por Catéter/efectos adversos
2.
J Cardiovasc Electrophysiol ; 32(10): 2785-2790, 2021 10.
Artículo en Inglés | MEDLINE | ID: mdl-34411358

RESUMEN

SCN5A gene variants are associated with both Brugada syndrome and conduction disturbances, sometimes expressing an overlapping phenotype. Functional consequences of SCN5A variants assessed by patch-clamp electrophysiology are particularly beneficial for correct pathogenic classification and are related to disease penetrance and severity. Here, we identify a novel SCN5A loss of function variant, p.1449Y>H, which presented with high penetrance and complete left bundle branch block, totally masking the typical findings on the electrocardiogram. We highlight the possibility of this overlap combination that makes impossible an electrocardiographic diagnosis and, through a functional analysis, associate the p.1449Y>H variant to SCN5A pathogenicity.


Asunto(s)
Síndrome de Brugada , Síndrome de Brugada/diagnóstico , Síndrome de Brugada/genética , Bloqueo de Rama/diagnóstico , Bloqueo de Rama/genética , Electrocardiografía , Humanos , Mutación , Canal de Sodio Activado por Voltaje NAV1.5/genética
3.
Pacing Clin Electrophysiol ; 42(6): 678-685, 2019 06.
Artículo en Inglés | MEDLINE | ID: mdl-30912154

RESUMEN

BACKGROUND: Interlesion distance and ablation index (AI) have been proposed as parameters of radiofrequency (RF) lesion durability. This study analyzes the relationship between RF parameters of automatically acquired lesion tags and late reconnections in repeat pulmonary vein isolation (PVI) procedures. METHODS: One hundred fifty-seven patients underwent contact force (CF)-guided PVI with automatic acquisition of RF lesions. During follow-up, 21 patients underwent a repeat PVI procedure. The relationship between RF parameters (power, CF, impedance drop, and AI) of the initial PVI procedure and reconnections observed at repeat PVI was analyzed. Visual gap was defined as the existence of a discontinuity between two RF lesions automatically acquired in the initial PVI procedure. Regional values of AI associated with lesion durability were identified. RESULTS: Twenty-one patients were included. Three hundred thirty-six segments and 2507 RF lesions were analyzed. The median interval between the initial and repeat PVI procedures was 17 (11-24) months. All patients showed ≥1 reconnected segment. Sixty-three segments (18.7%) were reconnected. Reconnected segments showed visual gaps more frequently than non-reconnected segments (66.6% vs 17.6%; P < .001; negative predictive value 91.4%). The mean distance of visual gaps was 8 ± 2.8 mm. No differences were observed in power (31.4 ± 4.7 W vs 31 ± 4.1 W; P = .573), CF (14.4 ± 5.3 g vs 15.4 ± 5.4 g; P = .315), and impedance drop (6.9 ± 5.2 ohms vs 6.5 ± 3.8 ohms; P = .576) between reconnected and non-reconnected segments. Among segments without visual gap, the minimum AI value was significantly higher in the non-reconnected segments (325 ± 96.1 vs 204.7 ± 78.5; P < .001). No reconnections were observed in segments without visual gap and minimum AI ≥ 330/220 in anterior/posterior wall, respectively. CONCLUSIONS: Contiguity between automatically acquired RF lesions and minimum AI value are the main determinants of long-term PVI durability.


Asunto(s)
Fibrilación Atrial/cirugía , Venas Pulmonares/cirugía , Ablación por Radiofrecuencia/métodos , Fibrilación Atrial/fisiopatología , Mapeo Epicárdico , Femenino , Humanos , Masculino , Persona de Mediana Edad , Recurrencia , Reoperación
4.
Europace ; 20(FI2): f171-f178, 2018 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-29106546

RESUMEN

Aims: Current navigation systems incorporate algorithms for automatic identification of local activation time (LAT). However, data about their utility and accuracy in premature ventricular complex (PVC) ablation procedures are scarce. This study analyses the accuracy of an algorithmic method based on automatic annotation of the maximal negative slope of the unipolar electrogram within the window demarcated by the bipolar electrogram compared with conventional manual annotation during PVC ablation procedures. Methods and results: Forty patients with successful ablation of focal PVC in three centres were included. Electroanatomical activation maps obtained with the automatic system (WF-map) were compared with manual annotation maps (M-map). Correlation and concordance of LAT obtained with both methods were assessed at 3536 points. The distance between the earliest activation site (EAS) and the effective radiofrequency application point (e-RFp) were determined in M-map and WF-map. The distance between WF-EAS and M-EAS was assessed. Successful ablation sites included left ventricular outflow tract (LVOT; 55%), right ventricular outflow tract (40%), and tricuspid annulus (5%). Good correlation was observed between the two annotation approaches (r = 0.655; P < 0.0001). Bland-Altman analysis revealed a systematic delayed detection of LAT by WF-map (bias 33.8 ± 30.9 ms), being higher in LVOT than in the right ventricle (42.6 ± 29.2 vs. 27.2 ± 30.5 ms, respectively; P < 0.0001). No difference in EAS-eRFp distance was observed between M-map and WF-map (1.8 ± 2.8 vs. 1.8 ± 3.4 mm, respectively; P = 0.986). The median (interquartile range) distance between WF-EAS and M-EAS was 2.2(0-6) mm. Conclusion: Good correlation was found between M-map and WF-map. Local activation time detection was systematically delayed in WF-map, especially in LVOT. Accurate identification of e-RFp was achieved with both annotation approaches.


Asunto(s)
Potenciales de Acción , Algoritmos , Ablación por Catéter , Técnicas Electrofisiológicas Cardíacas , Frecuencia Cardíaca , Procesamiento de Señales Asistido por Computador , Complejos Prematuros Ventriculares/diagnóstico , Complejos Prematuros Ventriculares/cirugía , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados , España , Factores de Tiempo , Resultado del Tratamiento , Complejos Prematuros Ventriculares/fisiopatología
5.
Europace ; 19(4): 607-616, 2017 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-28431051

RESUMEN

BACKGROUND: First-line endoepicardial ventricular tachycardia (VT) ablation has been proposed for patients with arrhythmogenic cardiomyopathy (AC). This study reports procedural safety, outcomes, and predictors of recurrence. METHODS AND RESULTS: Forty-one consecutive patients [12 with left ventricle (LV) involvement, 7 left-dominant] underwent first-line endoepicardial VT substrate ablation. Standard bipolar and unipolar thresholds were used to define low-voltage areas (LVA). Arrhythmogenic substrate area (ASA) was defined as the area containing electrograms with delayed components. Implantable cardioverter defibrillator interrogations were evaluated for VT recurrence. Epicardial LVA was larger in all cases (102.5 ± 78.6 vs. 19.3 ± 24.4 cm2; P< 0.001). Consistent with an epicardium-to-endocardium arrhythmogenic substrate progression pattern, epicardial ASA (epi-ASA) was negatively correlated with bipolar endocardial LVA (r = -0.368; P= 0.035) and with endocardial bipolar/unipolar-LVA (Bi/Uni-LVA) ratio (r= -0.38; P= 0.037). A Bi/Uni-LVA ratio >0.23 predicted an epi-ASA ≤10 cm2 (100% sensitivity, 84% specificity). Patients showing an epi-ASA < 10 cm2 required less epicardial (8.4 ± 5.8 vs. 25.3 ± 16; P= 0.045) and more endocardial (16.5 ± 8.6 vs. 7.5 ± 8.2; P= 0.047) radiofrequency applications. One patient with epi-ASA < 10 cm2 died of cardiac tamponade after epicardial puncture. Acute success (no VT inducibility after procedure) was achieved in 36 patients (90%). After 32.2 ± 21.8 months, 11 (26.8%) patients had VT recurrences. Left-dominant AC was associated with an increased risk of recurrence (HR = 3.41 [1.1-11.2], P= 0.044; log-rank P= 0.021). CONCLUSION: First-line endoepicardial VT substrate ablation achieves good long-term results in AC. Left-dominant AC is associated with an increased risk of recurrence. The Bi/Uni-LVA ratio identifies patients with limited epicardial arrhythmogenic substrate in whom the indication of epicardial approach should be more cautiously assessed.


Asunto(s)
Displasia Ventricular Derecha Arritmogénica/mortalidad , Displasia Ventricular Derecha Arritmogénica/cirugía , Ablación por Catéter/mortalidad , Ablación por Catéter/estadística & datos numéricos , Taquicardia Ventricular/mortalidad , Taquicardia Ventricular/prevención & control , Adulto , Displasia Ventricular Derecha Arritmogénica/diagnóstico , Causalidad , Terapia Combinada/mortalidad , Terapia Combinada/estadística & datos numéricos , Comorbilidad , Endocardio/cirugía , Femenino , Humanos , Estudios Longitudinales , Masculino , Persona de Mediana Edad , Pericardio/cirugía , Prevalencia , Recurrencia , Factores de Riesgo , Prevención Secundaria/estadística & datos numéricos , España/epidemiología , Tasa de Supervivencia , Taquicardia Ventricular/diagnóstico , Resultado del Tratamiento
7.
Pacing Clin Electrophysiol ; 39(4): 361-9, 2016 04.
Artículo en Inglés | MEDLINE | ID: mdl-26768692

RESUMEN

BACKGROUND: The impact of contact force (CF) monitoring in pulmonary vein (PV) isolation after a circumferential anatomic ablation (CAA) is unknown. We analyze the usefulness of CF monitoring in acute PV isolation and procedure parameters using a CAA. METHODS: Fifty patients with paroxysmal atrial fibrillation were randomized into CF-on (CF >10 grams; n = 25) or CF-off (CF blinded; n = 25) groups. We performed a first round of CAA with a ThermoCool(®) SmartTouch(®) catheter blinded to the LASSO(®) catheter (Biosense Webster, Diamond Bar, CA, USA), with radiofrequency (RF) lesions tagged with the VisiTag(™) Module. After the CAA, each PV was reviewed with the LASSO(®) catheter recording the segments with gaps. RESULTS: All the PVs were isolated with a CAA in 20 patients of the CF-on versus eight of the CF-off (P = 0.001). Of the 45 segments with gaps in the left PVs, 38 were from the CF-off (P = 0.0001). Of the eight segments with gaps in the right PVs, seven were from the CF-off (P = 0.06). The CF in the left PVs was higher in the CF-on (16.3 ± 3.2 grams vs 10.5 ± 4.3 grams; P = 0.0001) and similar in the right PVs (17.6 ± 3.6 grams vs 15.2 ± 5.3 grams; P = 0.08). All of the gaps were closed with additional RF LASSO(®) -guided touch-up. Procedure and fluoroscopy times were shorter in the CF-on (139 ± 24 minutes vs 157 ± 32 minutes and 20 ± 6 minutes vs 24 ± 7 minutes; both P = 0.039). At 12 months the patients free of AF recurrence was 84% CF-on versus 75% CF-off (log-rank P = 0.4) [corrected]. CONCLUSIONS: In paroxysmal atrial fibrillation, a CAA guided by CF reduces PV gaps and shortens the procedure parameters at the expense of the left PVs.


Asunto(s)
Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/cirugía , Mapeo del Potencial de Superficie Corporal/instrumentación , Ablación por Catéter/métodos , Venas Pulmonares/diagnóstico por imagen , Venas Pulmonares/cirugía , Adolescente , Adulto , Anciano , Fibrilación Atrial/patología , Mapeo del Potencial de Superficie Corporal/métodos , Ablación por Catéter/instrumentación , Diseño de Equipo , Femenino , Sistema de Conducción Cardíaco/patología , Sistema de Conducción Cardíaco/cirugía , Humanos , Masculino , Sistemas Hombre-Máquina , Persona de Mediana Edad , Monitoreo Intraoperatorio/instrumentación , Monitoreo Intraoperatorio/métodos , Venas Pulmonares/patología , Estrés Mecánico , Cirugía Asistida por Computador/instrumentación , Cirugía Asistida por Computador/métodos , Resultado del Tratamiento , Adulto Joven
8.
Pacing Clin Electrophysiol ; 38(2): 216-24, 2015 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-25534124

RESUMEN

BACKGROUND: Pulmonary vein isolation (PVI) causes a reduction in left atrium size that is attributable to reverse atrial remodeling (RAR). The objective of this study was to identify predictors of RAR and determine its association with other parameters of improvement in cardiac function. METHODS: It is a prospective study with 74 patients (52 ± 9 years old, 81% male), and 51% of patients had paroxysmal atrial fibrillation. Patients were serially assessed with transthoracic echocardiography; plasma N-terminal B-type natriuretic peptide (NT-proBNP); and high-sensitivity C-reactive protein levels at baseline and 3, 6, and 12 months following the PVI. RAR was defined as a reduction in the left atrial volume index (LAV-index) >10% from baseline at the end of follow-up. A multivariate analysis was conducted to identify predictors of RAR. RESULTS: The LAV-index decreased significantly during follow-up in the entire population (P = 0.0005). RAR (experienced by 63.5% of the patients) was more frequent (76% vs. 42%; P = 0.004) and pronounced (reduction 16.65 ± 14% vs. 8 ± 14%; P = 0.015) in patients with a successful ablation (46 of 74 patients, 62.2%). Only patients with RAR showed significant improvement in NT-proBNP levels (P = 0.0001), systolic function (P = 0.035), and diastolic function (P = 0.005). Multivariable analysis revealed that a successful ablation (odds ratio [OR] = 4.6; 95% confidence interval [CI] 1.46-14.68; P = 0.009), LAV-index (OR = 1.15; 95% CI 1.03-1.2; P = 0.021), and patient's body mass index (OR = 0.84; 95% CI 0.74-0.96; P = 0.012) were independent predictors of RAR. CONCLUSIONS: Successful PVI ablation is the main predictor of RAR that is associated with other parameters of improvement in cardiac function. The patient's body mass index may have a negative effect on RAR.


Asunto(s)
Fibrilación Atrial/fisiopatología , Fibrilación Atrial/cirugía , Remodelación Atrial , Índice de Masa Corporal , Sistema de Conducción Cardíaco/cirugía , Venas Pulmonares/cirugía , Fibrilación Atrial/diagnóstico , Ablación por Catéter/métodos , Femenino , Sistema de Conducción Cardíaco/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Pronóstico , Estudios Prospectivos , Venas Pulmonares/fisiopatología , Resultado del Tratamiento
9.
Microorganisms ; 12(3)2024 Mar 07.
Artículo en Inglés | MEDLINE | ID: mdl-38543588

RESUMEN

Background: Cardiac device infections are serious adverse events associated with considerable morbidity and mortality, significant costs, and increased healthcare utilization. The aim of this study is to calculate the costs of treatment of cardiac implantable electrostimulation device (CIED)-related infections for different types of infection (local or systemic) and therapeutic approaches. Patients and Methods: Single-center cohort (1985-2018). The costs of the CIED-related infections were analyzed according to initial treatment (antimicrobial treatment exclusively, local approach, or transvenous lead extraction (TLE)). Total costs (including those for hospitalization stay, drugs, extraction material, and newly implanted devices) were assigned to each case until its final resolution. Results: A total of 380 cases (233 local and 147 systemic infections) were analyzed. The average cost of systemic infection was EUR 34,086, mainly due to hospitalization (78.5%; mean: 24 ± 14 days), with a mortality rate of 10.8%. Local infection had a mortality rate of 2.5% (mainly related to the extraction procedure) and an average cost of EUR 21,790, which was higher in patients with resynchronization therapy devices and defibrillators (46% of total costs). Surgical procedures limited to the pocket for local infections resulted in a high rate of recurrence (87%), evolved to systemic infections in 48 patients, and had a higher cost compared to TLE (EUR 42,978 vs. EUR 24,699; p < 0.01). Conclusions: The costs of treating CIED-related infections are high and mainly related to the type of treatment and length of hospitalization. Complete device removal is always the most effective approach and is a cost-saving strategy.

10.
Front Physiol ; 15: 1331852, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38818521

RESUMEN

Cardiac arrhythmias cause depolarization waves to conduct unevenly on the myocardial surface, potentially delaying local components with respect to a previous beat when stimulated at faster frequencies. Despite the diagnostic value of localizing the distinct local electrocardiogram (EGM) components for identifying regions with decrement-evoked potentials (DEEPs), current software solutions do not perform automatic signal quantification. Electrophysiologists must manually measure distances on the EGM signals to assess the existence of DEEPs during pacing or extra-stimuli protocols. In this work, we present a deep learning (DL)-based algorithm to identify decrement in atrial components (measured in the coronary sinus) with respect to their ventricular counterparts from EGM signals, for disambiguating between accessory pathways (APs) and atrioventricular re-entrant tachycardias (AVRTs). Several U-Net and W-Net neural networks with different configurations were trained on a private dataset of signals from the coronary sinus (312 EGM recordings from 77 patients who underwent AP or AVRT ablation). A second, separate dataset was annotated for clinical validation, with clinical labels associated to EGM fragments in which decremental conduction was elucidated. To alleviate data scarcity, a synthetic data augmentation method was developed for generating EGM recordings. Moreover, two novel loss functions were developed to minimize false negatives and delineation errors. Finally, the addition of self-attention mechanisms and their effect on model performance was explored. The best performing model was a W-Net model with 6 levels, optimized solely with the Dice loss. The model obtained precisions of 91.28%, 77.78% and of 100.0%, and recalls of 94.86%, 95.25% and 100.0% for localizing local field, far field activations, and extra-stimuli, respectively. The clinical validation model demonstrated good overall agreement with respect to the evaluation of decremental properties. When compared to the criteria of electrophysiologists, the automatic exclusion step reached a sensitivity of 87.06% and a specificity of 97.03%. Out of the non-excluded signals, a sensitivity of 96.77% and a specificity of 95.24% was obtained for classifying them into decremental and non-decremental potentials. Current results show great promise while being, to the best of our knowledge, the first tool in the literature allowing the delineation of all local components present in an EGM recording. This is of capital importance at advancing processing for cardiac electrophysiological procedures and reducing intervention times, as many diagnosis procedures are performed by comparing segments or late potentials in subsequent cardiac cycles.

11.
J Cardiovasc Electrophysiol ; 24(10): 1075-82, 2013 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-23790041

RESUMEN

AIMS: Data on the success rate of ablation in atrial fibrillation (AF) are controversial. Our hypothesis is that the efficacy must be evaluated considering the AF burden (AFB) before the procedure. Moreover, the clinical significance of early recurrence (ERAT) of AF or atrial tachyarrhythmias (AT) is debatable. The aim is to describe the outcome of pulmonary vein isolation in paroxysmal AF through a subcutaneous cardiac monitor (ICM) implanted before the procedure. METHODS: Using CARTO 3, circumferential lesions around the pulmonary veins were placed. The study endpoint was the first documented recurrence of AF/AT by ICM after the blanking period (3 months). AFB (percentage of time in AF/AT) was collected every month before and after the procedure during the 12-month follow-up. RESULTS: The ICM was implanted 94 ± 23 days before the procedure in 35 patients with paroxysmal AF (54 ± 11 years, refractory to 1.8 ± 0.6 antiarrhythmic drugs). Cumulative AFB before the procedure and after the blanking period was 2.5% (1-5%) versus 0% (0-0.25%), P < 0.001. Twenty patients (57.1%) were free of documented AF/AT recurrence, 5 patients (14.2%) reduced the AFB 90%, 6 patients (17.1%) continued the same, and 4 patients (11.4%) increased the AFB 90% for AT. The success rate with second procedure was 71.4%. All 13 patients with ERAT had recurrence after the blanking period. CONCLUSIONS: The outcome of pulmonary vein isolation in patients with paroxysmal AF is well documented by an ICM. The success rate is dependent of the previous AFB that can be randomly variable and lower than expected. ERATs predict late recurrence.


Asunto(s)
Fibrilación Atrial/cirugía , Ablación por Catéter , Electrocardiografía/instrumentación , Frecuencia Cardíaca , Venas Pulmonares/cirugía , Telemetría/instrumentación , Adulto , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Ablación por Catéter/efectos adversos , Supervivencia sin Enfermedad , Diseño de Equipo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Estudios Prospectivos , Venas Pulmonares/fisiopatología , Recurrencia , Factores de Riesgo , Índice de Severidad de la Enfermedad , Taquicardia Supraventricular/diagnóstico , Taquicardia Supraventricular/etiología , Taquicardia Supraventricular/fisiopatología , Factores de Tiempo , Resultado del Tratamiento
12.
Pacing Clin Electrophysiol ; 35(10): e293-5, 2012 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-21091748

RESUMEN

We describe a case of ablation of atrioventricular nodal reentrant tachycardia in a patient with tricuspid atresia and L-malposition of great vessels using an electroanatomical mapping system integrated with cardiac magnetic resonance imaging. Atrial activation mapping during tachycardia identified the retrograde fast pathway proximal to the His bundle, observed in the left interatrial septum. Ablation was successfully completed below this area. Map integration with the patient's anatomy allowed a safe, individualized procedure.


Asunto(s)
Ablación por Catéter , Taquicardia por Reentrada en el Nodo Atrioventricular/cirugía , Atresia Tricúspide/cirugía , Adolescente , Tabique Interatrial/fisiopatología , Tabique Interatrial/cirugía , Fascículo Atrioventricular/fisiopatología , Fascículo Atrioventricular/cirugía , Electrocardiografía , Técnicas Electrofisiológicas Cardíacas , Procedimiento de Fontan , Sistema de Conducción Cardíaco/fisiopatología , Sistema de Conducción Cardíaco/cirugía , Humanos , Imagen por Resonancia Magnética , Masculino , Taquicardia por Reentrada en el Nodo Atrioventricular/fisiopatología , Transposición de los Grandes Vasos/fisiopatología , Transposición de los Grandes Vasos/cirugía , Resultado del Tratamiento , Atresia Tricúspide/fisiopatología
13.
J Womens Health (Larchmt) ; 30(4): 596-603, 2021 04.
Artículo en Inglés | MEDLINE | ID: mdl-33170080

RESUMEN

Background: Whether the sex factor influences the benefit of the implantable cardioverter-defibrillator (ICD) for the prevention of sudden death remains a subject of debate. Using a prospective registry, we sought to analyze the survival and time to first ICD therapy according to sex. Materials and Methods: Retrospective analysis of a prospective cohort of patients undergoing an ICD implant from 2008 to 2019. Data about time to first appropriate therapy, type of therapy administered, and incidence and causes of mortality were collected. Results: Among 756 ICD patients, 150 (19.8%) were women. Women were younger (51 ± 15 years vs. 61 ± 14 years; p < 0.001) and showed a lower rate of ischemic cardiomyopathy (23% vs. 54%; p < 0.001) and atrial fibrillation (12% vs. 19%; p = 0.05). Women had higher left ventricular ejection fraction (39% ± 17% vs. 35% ± 13%) and showed more frequently left bundle branch block (39% vs. 28%, p = 0.027). The rate of primary prevention (68% vs. 59.6%; p = 0.058) and cardiac resynchronization therapy (27% vs. 19%, p = 0.02) were higher in women. After a median follow-up of 46 months (3382 patient-years), the incidence of both the primary combined endpoint of mortality/transplant (20% vs. 29%; logrank = 0.031) and ICD therapies (27% vs. 34%; p = 0.138) were lower in women. According to the propensity score-matching analysis, no differences were observed between both sexes with respect to the incidence of mortality/transplant (24.8% vs. 28.6%; logrank = 0.88), ICD therapies (28% vs. 27%; logrank = 0.17), and main cause of death (heart failure [HF]). Conclusions: The clinical characteristics at the moment of ICD implant are different between sexes. After adjusting them, both sexes equally benefit from the ICD. HF is the main cause of mortality both in men and women.


Asunto(s)
Terapia de Resincronización Cardíaca , Desfibriladores Implantables , Insuficiencia Cardíaca , Femenino , Insuficiencia Cardíaca/terapia , Humanos , Masculino , Estudios Retrospectivos , Factores de Riesgo , Volumen Sistólico , Resultado del Tratamiento , Función Ventricular Izquierda
16.
Rev Port Cardiol (Engl Ed) ; 39(3): 171-173, 2020 Mar.
Artículo en Inglés, Portugués | MEDLINE | ID: mdl-32336522

RESUMEN

Antiarrhythmic drugs are often the last resort for recurrent ventricular tachycardia refractory to catheter ablation in implantable cardioverter-defibrillator carriers. Amiodarone, alone or combined with mexiletine, is usually but not always highly effective, and its use is usually limited by systemic adverse effects. We present the case of a 62 years old man with recurrent ICD shocks due to a VT refractory to an endo-epicardial hybrid ablation. Starting of dronedarone plus mexiletine combination showed an excellent result.


Asunto(s)
Amiodarona/uso terapéutico , Dronedarona/uso terapéutico , Mexiletine/uso terapéutico , Taquicardia Ventricular/tratamiento farmacológico , Amiodarona/efectos adversos , Antiarrítmicos/efectos adversos , Antiarrítmicos/uso terapéutico , Ablación por Catéter/efectos adversos , Ablación por Catéter/estadística & datos numéricos , Desfibriladores Implantables/efectos adversos , Quimioterapia Combinada , Humanos , Masculino , Persona de Mediana Edad , Taquicardia Ventricular/etiología , Resultado del Tratamiento
17.
Heart Rhythm ; 17(10): 1696-1703, 2020 10.
Artículo en Inglés | MEDLINE | ID: mdl-32417258

RESUMEN

BACKGROUND: Ventricular tachycardia substrate ablation (VTSA) incorporating hidden slow conduction (HSC) analysis allows further arrhythmic substrate identification. OBJECTIVE: The purpose of this study was to analyze whether the elimination of HSC electrograms (HSC-EGMs) during VTSA results in better short- and long-term outcomes. METHODS: Consecutive patients (N = 70; 63% ischemic; mean age 64 ± 14.6 years) undergoing VTSA were prospectively included. Bipolar EGMs with >3 deflections and duration <133 ms were considered as potential HSC-EGMs. Whenever a potential HSC-EGM was identified, double or triple ventricular extrastimuli were delivered. If a local potential showed up as a delayed component, it was annotated as HSC-EGM. Ablation was delivered at conducting channel entrances and HSC-EGMs. Radiofrequency time, ventricular tachycardia (VT) inducibility after VTSA, and VT/ventricular fibrillation recurrence at 24 months after the procedure were compared with data from a historical control group. RESULTS: A total of 5076 EGMs were analyzed; 1029 (20.2%) qualified as potential HSC-EGMs, and 475 of them were tagged as HSC-EGMs. Scars in patients with HSC-EGMs (n = 43 [61.4%]) were smaller (32.2 [17-58] cm2 vs 85 [41-92.4] cm2; P = .006) and more heterogeneous (core/scar area ratio 0.15 [0.05-0.44] vs 0.44 [0.33-0.57]; P = .017); 32.4% of HSC-EGMs were located in normal voltage tissue. Patients undergoing VTSA incorporating HSC analysis required less radiofrequency time (15.6 [8-23.1] vs 23.9 [14.9-30.8]; P < .001) and had a lower rate of VT inducibility after VTSA (28.6% vs 52.9%; P = .003) than did the historical controls. Patients undergoing VTSA incorporating HSC analysis showed a higher 2-year VT/ventricular fibrillation-free survival (75.7% vs 58.8%; log-rank, P = .046) after VTSA. CONCLUSION: VTSA incorporating HSC analysis allowed further arrhythmic substrate identification (especially in the border zone and normal voltage areas) and was associated with increased VTSA efficiency and better short- and long-term outcomes.


Asunto(s)
Ablación por Catéter/métodos , Electrocardiografía , Sistema de Conducción Cardíaco/fisiopatología , Frecuencia Cardíaca/fisiología , Ventrículos Cardíacos/fisiopatología , Taquicardia Ventricular/fisiopatología , Anciano , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Taquicardia Ventricular/cirugía , Factores de Tiempo
19.
Indian Pacing Electrophysiol J ; 9(4): 233-7, 2009 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-19652737

RESUMEN

We report an unusual association of persistent atrial flutter and bundle branch re-entrant ventricular tachycardia in a young patient without structural heart disease. Atrial flutter masked the infra-Hisian conduction disease, was fundamentally dependent on a long PR interval, and could be a possible trigger of ventricular tachycardia.

20.
Indian Pacing Electrophysiol J ; 8(1): 72-4, 2008 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-18270605

RESUMEN

We describe the case of a patient who developed a thrombus on the transseptal sheath in the right atrium before transseptal puncture for circumferential pulmonary vein isolation for paroxysmal atrial fibrillation treatment. The use of intracardiac echocardiography allowed to its identification and probably prevented the patient from suffering a serious thromboembolic complication.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA