1.
J Clin Monit Comput ; 33(5): 815-824, 2019 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-30554338

RESUMEN

To determine whether a classification based on the contour of the photoplethysmography signal (PPGc) can detect changes in systolic arterial blood pressure (SAP) and vascular tone. Episodes of normotension (SAP 90-140 mmHg), hypertension (SAP > 140 mmHg) and hypotension (SAP < 90 mmHg) were analyzed in 15 cardiac surgery patients. SAP and two surrogates of the vascular tone, systemic vascular resistance (SVR) and vascular compliance (Cvasc = stroke volume/pulse pressure) were compared with PPGc. Changes in PPG amplitude (foot-to-peak distance) and dicrotic notch position were used to define 6 classes taking class III as a normal vascular tone with a notch placed between 20 and 50% of the PPG amplitude. Class I-to-II represented vasoconstriction with notch placed > 50% in a small PPG, while class IV-to-VI described vasodilation with a notch placed < 20% in a tall PPG wave. 190 datasets were analyzed including 61 episodes of hypertension [SAP = 159 (151-170) mmHg (median 1st-3rd quartiles)], 84 of normotension, SAP = 124 (113-131) mmHg and 45 of hypotension SAP = 85(80-87) mmHg. SAP were well correlated with SVR (r = 0.78, p < 0.0001) and Cvasc (r = 0.84, p < 0.0001). The PPG-based classification correlated well with SAP (r = - 0.90, p < 0.0001), SVR (r = - 0.72, p < 0.0001) and Cvasc (r = 0.82, p < 0.0001). The PPGc misclassified 7 out of the 190 episodes, presenting good accuracy (98.4% and 97.8%), sensitivity (100% and 94.9%) and specificity (97.9% and 99.2%) for detecting episodes of hypotension and hypertension, respectively. Changes in arterial pressure and vascular tone were closely related to the proposed classification based on PPG waveform.Clinical Trial Registration NTC02854852.


Asunto(s)
Presión Arterial , Fotopletismografía/métodos , Procesamiento de Señales Asistido por Computador , Anciano , Anciano de 80 o más Años , Algoritmos , Puente de Arteria Coronaria , Femenino , Hemodinámica , Humanos , Hipertensión/diagnóstico , Hipotensión/diagnóstico , Masculino , Persona de Mediana Edad , Proyectos Piloto , Estudios Prospectivos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Volumen Sistólico , Vasoconstricción , Vasodilatación
2.
Anesth Analg ; 122(5): 1404-11, 2016 May.
Artículo en Inglés | MEDLINE | ID: mdl-26505574

RESUMEN

BACKGROUND: We sought to determine whether the response of pulmonary elimination of CO2 (VCO2) to a sudden increase in positive end-expiratory pressure (PEEP) could predict fluid responsiveness and serve as a noninvasive surrogate for cardiac index (CI). METHODS: Fifty-two patients undergoing cardiovascular surgery were included in this study. By using a constant-flow ventilation mode, we performed a PEEP challenge of 1-minute increase in PEEP from 5 to 10 cm H2O. At PEEP of 5 cm H2O, patients were preloaded with 500 mL IV saline solution after which a second PEEP challenge was performed. Patients in whom fluid administration increased CI by ≥15% from the individual baseline value were defined as volume responders. Beat-by-beat CI was derived from arterial pulse contour analysis, and breath-by-breath VCO2 data were collected during the protocol. The sensitivity and specificity of VCO2 for detecting the fluid responders according to CI was performed by the receiver operating characteristic curves. RESULTS: Twenty-one of 52 patients were identified as fluid responders (40%). The PEEP maneuver before fluid administration decreased CI from 2.65 ± 0.34 to 2.21 ± 0.32 L/min/m (P = 0.0011) and VCO2 from 150 ± 23 to 123 ± 23 mL/min (P = 0.0036) in responders, whereas the changes in CI and VCO2 were not significant in nonresponders. The PEEP challenge after fluid administration induced no significant changes in CI and VCO2, in neither responders nor nonresponders. PEEP-induced decreases in CI and VCO2 before fluid administration were well correlated (r = 0.75, P < 0.0001) but not thereafter. The area under the receiver operating characteristic curves for a PEEP-induced decrease in ΔCI and ΔVCO2 was 0.99, with a 95% confidence interval from 0.96 to 0.99 for ΔCI and from 0.97 to 0.99 for ΔVCO2. During the PEEP challenge, a decrease in VCO2 by 11% predicted fluid responsiveness with a sensitivity of 0.90 (95% confidence interval, 0.87-0.93) and a specificity of 0.95 (95% confidence interval, 0.92-0.98). CONCLUSIONS: PEEP-induced changes in VCO2 predicted fluid responsiveness with accuracy in patients undergoing cardiac surgery.


Asunto(s)
Pruebas Respiratorias/métodos , Capnografía , Dióxido de Carbono/metabolismo , Fluidoterapia/métodos , Hemodinámica , Pulmón/metabolismo , Respiración con Presión Positiva , Cloruro de Sodio/administración & dosificación , Anciano , Área Bajo la Curva , Biomarcadores/metabolismo , Procedimientos Quirúrgicos Cardíacos , Femenino , Fluidoterapia/efectos adversos , Humanos , Infusiones Intravenosas , Masculino , Persona de Mediana Edad , Selección de Paciente , Valor Predictivo de las Pruebas , Estudios Prospectivos , Curva ROC , Reproducibilidad de los Resultados , Cloruro de Sodio/efectos adversos , Factores de Tiempo
3.
Anesth Analg ; 118(1): 137-44, 2014 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-24356163

RESUMEN

BACKGROUND: We conducted this study to determine whether pulse oximetry and volumetric capnography (VCap) can determine the opening and closing pressures of lungs of anesthetized morbidly obese patients. METHODS: Twenty morbidly obese patients undergoing laparoscopic bariatric surgery with capnoperitoneum were studied. A lung recruitment maneuver was performed in pressure control ventilation as follows: (1) During an ascending limb, the lungs' opening pressure was detected. After increasing positive end-expiratory pressure (PEEP) from 8 to 16 cm H2O, fraction of inspired oxygen (FIO2) was decreased until pulse oximetric arterial saturation (SpO2) was <92%. Thereafter, end-inspiratory pressure was increased in steps of 2 cm H2O, from 36 to a maximum of 50 cm H2O. The opening pressure was attained when SpO2 exceeded 97%. (2) During a subsequent decreasing limb, the lungs' closing pressure was identified. PEEP was decreased from 22 to 10 cm H2O in steps of 2 cm H2O. The closing pressure was determined as the PEEP value at which respiratory compliance decreased from its maximum value. We continuously recorded lung mechanics, SpO2, and VCap. RESULTS: The lungs' opening pressures were detected at 44 (4) cm H2O (median and interquartile range) and the closing pressure at 14 (2) cm H2O. Therefore, the level of PEEP that kept the lungs without collapse was found to be 16 (3) cm H2O. Using respiratory compliance as a reference, receiver operating characteristic analysis showed that SpO2 (area under the curve [AUC] 0.80 [SE 0.07], sensitivity 0.65, and specificity 0.94), the elimination of CO2 per breath (AUC 0.91 [SE 0.05], sensitivity 0.85, and specificity 0.98), and Bohr's dead space (AUC 0.83 [SE 0.06], sensitivity 0.70, and specificity 0.95] were relatively accurate for detecting lung collapse during the decreasing limb of a recruitment maneuver. CONCLUSIONS: Lung recruitment in morbidly obese patients could be effectively monitored by combining noninvasive pulse oximetry and VCap. SpO2, the elimination of CO2, and Bohr's dead space detected the individual's opening and closing pressures.


Asunto(s)
Capnografía/métodos , Pulmón/metabolismo , Monitoreo Intraoperatorio/métodos , Obesidad Mórbida/metabolismo , Obesidad Mórbida/cirugía , Oximetría/métodos , Adulto , Cirugía Bariátrica/métodos , Femenino , Humanos , Mediciones del Volumen Pulmonar/métodos , Masculino , Persona de Mediana Edad , Proyectos Piloto , Respiración con Presión Positiva/métodos , Intercambio Gaseoso Pulmonar/fisiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA