Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 25
Filtrar
Más filtros

Bases de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Medicina (Kaunas) ; 60(4)2024 Mar 22.
Artículo en Inglés | MEDLINE | ID: mdl-38674168

RESUMEN

The application of cardiac magnetic resonance (CMR) imaging in clinical practice has grown due to technological advancements and expanded clinical indications, highlighting its superior capabilities when compared to echocardiography for the assessment of myocardial tissue. Similarly, the utilization of implantable cardiac electronic devices (CIEDs) has significantly increased in cardiac arrhythmia management, and the requirements of CMR examinations in patients with CIEDs has become more common. However, this type of exam often presents challenges due to safety concerns and image artifacts. Until a few years ago, the presence of CIED was considered an absolute contraindication to CMR. To address these challenges, various technical improvements in CIED technology, like the reduction of the ferromagnetic components, and in CMR examinations, such as the introduction of new sequences, have been developed. Moreover, a rigorous protocol involving multidisciplinary collaboration is recommended for safe CMR examinations in patients with CIEDs, emphasizing risk assessment, careful monitoring during CMR, and post-scan device evaluation. Alternative methods to CMR, such as computed tomography coronary angiography with tissue characterization techniques like dual-energy and photon-counting, offer alternative potential solutions, although their diagnostic accuracy and availability do limit their use. Despite technological advancements, close collaboration and specialized staff training remain crucial for obtaining safe diagnostic CMR images in patients with CIEDs, thus justifying the presence of specialized centers that are equipped to handle these type of exams.


Asunto(s)
Desfibriladores Implantables , Imagen por Resonancia Magnética , Marcapaso Artificial , Humanos , Desfibriladores Implantables/normas , Imagen por Resonancia Magnética/métodos , Imagen por Resonancia Magnética/instrumentación , Arritmias Cardíacas/diagnóstico por imagen
2.
Medicina (Kaunas) ; 60(4)2024 Apr 08.
Artículo en Inglés | MEDLINE | ID: mdl-38674259

RESUMEN

Background and Objectives: Cardiac magnetic resonance (CMR) imaging has become an essential instrument in the study of cardiomyopathies; it has recently been integrated into the diagnostic workflow for cardiac amyloidosis (CA) with remarkable results. An additional emerging role is the stratification of the arrhythmogenic risk by scar analysis and the possibility of merging these data with electro-anatomical maps. This is made possible by using a software (ADAS 3D, Galgo Medical, Barcelona, Spain) able to provide 3D heart models by detecting fibrosis along the whole thickness of the myocardial walls. Little is known regarding the applications of this software in the wide spectrum of cardiomyopathies and the potential benefits have yet to be discovered. In this study, we tried to apply the ADAS 3D in the context of CA. Materials and Methods: This study was a retrospectively analysis of consecutive CMR imaging of patients affected by CA that were treated in our center (Marche University Hospital). Wherever possible, the data were processed with the ADAS 3D software and analyzed for a correlation between the morphometric parameters and follow-up events. The outcome was a composite of all-cause mortality, unplanned cardiovascular hospitalizations, sustained ventricular arrhythmias (VAs), permanent reduction in left ventricular ejection fraction, and pacemaker implantation. The secondary outcomes were the need for a pacemaker implantation and sustained VAs. Results: A total of 14 patients were deemed eligible for the software analysis: 8 patients with wild type transthyretin CA, 5 with light chain CA, and 1 with transthyretin hereditary CA. The vast majority of imaging features was not related to the composite outcome, but atrial wall thickening displayed a significant association with both the primary (p = 0.003) and the secondary outcome of pacemaker implantation (p = 0.003). The software was able to differentiate between core zones and border zones of scars, with the latter being the most extensively represented in all patients. Interestingly, in a huge percentage of CMR images, the software identified the highest degree of core zone fibrosis among the epicardial layers and, in those patients, we found a higher incidence of the primary outcome, without reaching statistical significance (p = 0.18). Channels were found in the scar zones in a substantial percentage of patients without a clear correlation with follow-up events. Conclusions: CMR imaging plays a pivotal role in cardiovascular diagnostics. Our analysis shows the feasibility and applicability of such instrument for all types of CA. We could not only differentiate between different layers of scars, but we were also able to identify the presence of fibrosis channels among the different scar zones. None of the data derived from the ADAS 3D software seemed to be related to cardiac events in the follow-up, but this might be imputable to the restricted number of patients enrolled in the study.


Asunto(s)
Amiloidosis , Cardiomiopatías , Cicatriz , Imagen por Resonancia Magnética , Humanos , Masculino , Proyectos Piloto , Femenino , Cardiomiopatías/diagnóstico por imagen , Amiloidosis/diagnóstico por imagen , Amiloidosis/complicaciones , Anciano , Cicatriz/diagnóstico por imagen , Estudios Retrospectivos , Persona de Mediana Edad , Imagen por Resonancia Magnética/métodos , Programas Informáticos
3.
Medicina (Kaunas) ; 59(9)2023 Sep 12.
Artículo en Inglés | MEDLINE | ID: mdl-37763769

RESUMEN

Background and Objectives: Recently published articles reported an association between psoriasis and interstitial lung diseases (ILDs). The aim of this study is to evaluate the differences in ILD computed tomography (CT) patterns between smoker and never smoker plaque psoriasis (PP) patients under topical treatment without psoriatic arthritis (PA), inflammatory bowel disease (IBD) or connective tissue diseases (CTDs). Matherials and Methods: Two radiologists evaluated chest CT examinations of 65 patients (33 smokers, 32 never smokers) with PP. Results: Usual interstitial pneumonia (UIP) pattern was diagnosed in 36 patients, nonspecific interstitial pneumonia pattern in 19, hypersensitivity pneumonitis in 7 and pleuropulmonary fibroelastosis (PPFE) in 3 patients. UIP pattern showed a statistically significant higher frequency in smoker patients (p = 0.0351). Respiratory symptoms were reported in 80% of patients. Conclusions: ILDs seems to represent a new comorbidity associated with psoriasis. Moreover, a statistically significant association between smokers and UIP pattern in PP patients is found. Respiratory symptoms should be evaluated in PP patients, in collaboration with a radiologist and a pneumologist. However, further studies are required to better understand the epidemiology of ILDs in PP patients.


Asunto(s)
Fibrosis Pulmonar Idiopática , Enfermedades Pulmonares Intersticiales , Psoriasis , Humanos , Estudios Retrospectivos , Enfermedades Pulmonares Intersticiales/complicaciones , Enfermedades Pulmonares Intersticiales/diagnóstico por imagen , Enfermedades Pulmonares Intersticiales/epidemiología , Psoriasis/complicaciones , Psoriasis/diagnóstico por imagen , Psoriasis/epidemiología , Tomografía Computarizada por Rayos X
4.
Medicina (Kaunas) ; 60(1)2023 Dec 29.
Artículo en Inglés | MEDLINE | ID: mdl-38256331

RESUMEN

A cardiac lesion detected at ultrasonography might turn out to be a normal structure, a benign tumor or rarely a malignancy, and lesion characterization is very important to appropriately manage the lesion itself. The exact relationship of the mass with coronary arteries and the knowledge of possible concomitant coronary artery disease are necessary preoperative information. Moreover, the increasingly performed coronary CT angiography to evaluate non-invasively coronary artery disease leads to a rising number of incidental findings. Therefore, CT and MRI are frequently performed imaging modalities when echocardiography is deemed insufficient to evaluate a lesion. A brief comprehensive overview about diagnostic radiological imaging and the clinical background of cardiac masses and pseudomasses is reported.


Asunto(s)
Enfermedad de la Arteria Coronaria , Humanos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Tomografía Computarizada por Rayos X , Angiografía por Tomografía Computarizada , Angiografía Coronaria
5.
J Clin Ultrasound ; 50(6): 817-825, 2022 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-35730639

RESUMEN

The ultra-high frequency ultrasound (UHFUS) is characterized by the use of probes between 30 and 100 MHz. This technology has recently been introduced in clinical practice and represents an opportunity for the diagnosis of numerous pathologies. The high spatial resolution of UHFUS, up to 30 µ in pixel size, allows to study the pathological modifications and to guide microsurgery treatments in anatomical body structures not evaluable by conventional HFUS. The aim of this work is to provide a review of the literature on the current clinical applications of UHFUS and to discuss its added role in different clinical settings.


Asunto(s)
Ultrasonografía , Humanos , Ultrasonografía/métodos
6.
Radiol Med ; 127(5): 571-576, 2022 May.
Artículo en Inglés | MEDLINE | ID: mdl-35290569

RESUMEN

PURPOSE: To compare point shear wave elastography (pSWE, ElastPQ®) and transient elastography (TE) with Liver Biopsy in order to evaluate fibrosis stage in non-alcoholic fatty liver disease (NAFLD). METHODS: Our prospective study from September 2017 to October 2020 included 50 consecutively enrolled patients with NAFLD (52.2 ± 13.0 years, 32 male). All patients underwent clinical evaluation, B-mode ultrasound, pSWE, TE and liver biopsy in a single evaluation. The clinical, laboratory and liver biopsy data were compared with liver stiffness (LS) measurement obtained with pSWE and TE. TE and pSWE diagnostic accuracy for the diagnosis of the different fibrosis stages were evaluated using the area under receiver operating characteristic curve (AUROC). RESULTS: Only fibrosis stage was independently associated with TE and pSWE. The median liver stiffness measurement for fibrosis stages F0, F1, F2, F3, and F4 using TE was 4.8 (4.7-6.1) kPa, 5.5 (4.4-7.3) kPa, 7.7 (6.1-9.1) kPa, 9.9 (8.8-13.8) kPa, and 20.2 kPa, respectively. The corresponding median liver stiffness measurement using pSWE was 4.2 (4.0-4.8) kPa, 4.7 (4.2-5.8) kPa, 5.1 (4.1-6.9) kPa, 8.5 (5.2-13.3), and 15.1 kPa, respectively. The AUROC of TE for diagnosis of fibrosis stage F1, ≥ F2, ≥ F3, and F4 were 0.795, 0.867, 0.927, and 0.990, respectively. The corresponding AUROC of pSWE was 0.717, 0.733, 0.908, and 1.000, respectively. No association was observed with other histological parameters. CONCLUSION: TE was significantly better than pSWE for the diagnosis of fibrosis stage ≥ F2. No statistically significant differences were found between TE and pSWE AUROC of fibrosis stage ≥ F1, ≥ F3, and F4.


Asunto(s)
Diagnóstico por Imagen de Elasticidad , Enfermedad del Hígado Graso no Alcohólico , Biopsia , Fibrosis , Humanos , Hígado/diagnóstico por imagen , Hígado/patología , Cirrosis Hepática/diagnóstico por imagen , Cirrosis Hepática/patología , Masculino , Enfermedad del Hígado Graso no Alcohólico/diagnóstico por imagen , Enfermedad del Hígado Graso no Alcohólico/patología , Estudios Prospectivos , Curva ROC
7.
Radiol Med ; 127(11): 1221-1227, 2022 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-36123521

RESUMEN

PURPOSE: To evaluate the reproducibility of the 2D shear wave elastography (2D-SWE) method and to identify the prognostic factors of breast lesions. METHODS: In this prospective study, 44 female patients were consecutively included from January 2020 to September 2021. All patients showing visible masses at B-mode ultrasound underwent to clinical evaluation, followed by qualitative and quantitative 2D-SWE by two different operators with over 15-year and 2-year experience, respectively. Subsequently, patients underwent to surgical treatment after core needle biopsy. Reproducibility of qualitative and quantitative 2D-SWE was evaluated by Cohen's kappa and intraclass correlation coefficient (ICC). Clinical, imaging, and histopathological data and 2D-SWE evaluations were analysed with Spearman's rank correlation test. RESULTS: The mean age of the patients was 55 years ± 12. The mean histological and ultrasound tumour size of were 23.1 mm ± 13.2 and 17.2 mm ± 10.2, respectively. The interobserver agreement showed a good reproducibility limited to the qualitative evaluation colour maps (Cohen's kappa = 0.603) and to the quantitative evaluation E ratio (ICC = 0.771). Correlation analysis between the ultrasound and 2D-SWE values and the clinical-pathological parameters showed a significant relationship between E ratio and Elston-Ellis grading (P < 0.030) and between tumour size and Elston-Ellis grading (P < 0.041). CONCLUSION: The 2D-SWE has shown good reproducibility among operators with different experience. It could be a promising tool in the evaluation of some prognostic factors in ultrasound visible breast cancer.


Asunto(s)
Neoplasias de la Mama , Diagnóstico por Imagen de Elasticidad , Humanos , Femenino , Persona de Mediana Edad , Diagnóstico por Imagen de Elasticidad/métodos , Neoplasias de la Mama/diagnóstico por imagen , Neoplasias de la Mama/patología , Reproducibilidad de los Resultados , Estudios Prospectivos , Pronóstico , Ultrasonografía Mamaria/métodos
8.
Radiol Med ; 126(6): 894-899, 2021 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-33492651

RESUMEN

PURPOSE: To compare the ultrasound (US) and pulse shear wave elastography (pSWE, Elast PQ®) methods with transient elastography (TE), clinical scores and laboratory tests, during the follow-up of HCV patients receiving direct-acting antiviral drugs (DAA). METHODS: Our prospective study from June 2016 to December 2017 included 22 consecutively enrolled HCV-positive patients (59.7 ± 12.3 years, 11 male) which were subjected to antiviral therapy. All patients underwent B-mode ultrasound, color-Doppler, pSWE and TE five times: before therapy (T0), at the end of therapy (post-Tx), and at 12, 24, 48 weeks post-therapy. The liver stiffness (LS) values obtained with pSWE and TE and the data coming from US assessment and clinical evaluation were compared. RESULTS: We obtained a statistically significant reduction of LS values (kPa) measured by pSWE, between T0 (14.3 ± 9.3), post-Tx (11.8 ± 10.5), 12 weeks (7.5 ± 3.3), 24 weeks (8 ± 3.8) and 48 weeks (8.5 ± 4.6) (p = 0.02). The reduction of kPa measured by TE was not significant between T0 (14.7 ± 9.3), post-Tx (12 ± 9.5), 12 weeks (11.6 ± 7.7), 24 weeks (10.3 ± 6) and 48 weeks (10.8 ± 7.5) (p > 0.05). Multivariate baseline analysis showed significant independent association among measurement of TE stiffness with cirrhosis, type of vein hepatic flow and showed significant independent association between delta-pSWE measurement (difference between stiffness measurements at the baseline and 12 months after treatment) with staging of fibrosis (p = 0.006) and sustained virologic response after 12 weeks of treatment (SVR12, p = 0.017). CONCLUSION: The pSWE method has shown better ability than TE to identify a reduction in LS. Therefore, pSWE allow to evaluate stiffness reduction in HCV patient during DAA treatment follow-up, which is related to SVR12.


Asunto(s)
Antivirales/uso terapéutico , Diagnóstico por Imagen de Elasticidad/métodos , Hepatitis C Crónica/patología , Hígado/patología , Femenino , Estudios de Seguimiento , Hepatitis C Crónica/tratamiento farmacológico , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Reproducibilidad de los Resultados
9.
Radiol Med ; 124(3): 170-175, 2019 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-30488252

RESUMEN

INTRODUCTION: We describe the use of contrast-enhanced ultrasound (CEUS) in the diagnosis of delayed splenic vascular injury (DSVI) and active extravasation (DAE) during spleen injury follow-up. CEUS might be used instead of contrast-enhanced computed tomography (CECT) during spleen injury follow-up in order to reduce radiation exposure. OBJECTIVE: Assess diagnostic comparability between CEUS and CECT in the evaluation of DSVI and DAE during spleen injury follow-up. SUBJECTS AND METHODS: A total of 139 trauma patients (101 males, 38 females; mean age 48.6 years) with CECT diagnosed spleen injury were prospectively evaluated. They performed CEUS and CECT follow-up. All CEUS studies were performed using the same ultrasound scan, convex probe, mechanical index and ultrasound contrast agent dose. Twelve patients performed digital subtraction angiography (DSA) during follow-up, and the diagnostic performance comparability between CEUS and DSA was evaluated. RESULTS: CEUS showed 17 delayed spleen injury complications, and in 122 patients no complication was suspected. CECT diagnosed 16 delayed spleen injury complications in these 17 patients and showed a small DSVI in another patient. A total of 122 follow-up CT scans were negative. CEUS and CECT diagnostic comparability was 98.6%. Compared to DSA, CEUS showed a sensitivity of 100% and a positive predictive value of 91.7%. CONCLUSIONS: CEUS can be used during spleen injury follow-up instead of CECT. Positive CEUS examinations could perform CECT and, when necessary, DSA in order to confirm and treat spleen injury complications.


Asunto(s)
Extravasación de Materiales Terapéuticos y Diagnósticos/diagnóstico por imagen , Bazo/diagnóstico por imagen , Bazo/lesiones , Lesiones del Sistema Vascular/diagnóstico por imagen , Heridas no Penetrantes/diagnóstico por imagen , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Angiografía de Substracción Digital , Medios de Contraste , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Bazo/irrigación sanguínea , Factores de Tiempo , Tomografía Computarizada por Rayos X , Ultrasonografía/métodos , Adulto Joven
10.
Radiol Med ; 124(3): 163-169, 2019 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-30361922

RESUMEN

AIMS: To assess mean healing time of blunt spleen injuries managed nonoperatively using CEUS (contrast-enhanced ultrasound); to analyze whether spleen injury grade, subcapsular hematoma (SCH) presence, SCH grade and spleen infarct after spleen artery angioembolization could be related to healing time; and to evaluate CEUS sensitivity in diagnosing spleen injury and to assess CEUS performance in classifying spleen injury grade compared to CT. MATERIALS AND METHODS: After CT evaluation in the Emergency Department, 101 hemodynamic stable blunt spleen trauma patients (73 males; 28 females; mean age 46.4 years, range 18-92) underwent serial CEUS follow-up examinations at pre-established intervals (1, 3, 8, 15, 30, 60, 90 and 180 days after trauma), until spleen injury became no more identifiable. RESULTS: Mean CEUS examinations performed before spleen injury healing were 4.5; mean spleen injury healing time was 22.6 days. Spleen injury healing time was significantly related to spleen injury grade, subcapsular hematoma (SCH) presence, SCH grade and spleen infarct. CEUS spleen injury diagnostic sensitivity was 96.9% and, according to the American Association for the Surgery of Trauma (AAST)-spleen injury scale (SIS), CEUS-CT concordance was 95.8%. CONCLUSIONS: Spleen injury healing time in blunt abdominal trauma nonoperatively managed is significantly related to AAST-SIS grade, SCH presence and grade, and spleen infarct development, and CEUS can be used in order to evaluate spleen injury grade.


Asunto(s)
Bazo/diagnóstico por imagen , Bazo/lesiones , Cicatrización de Heridas , Heridas no Penetrantes/diagnóstico por imagen , Heridas no Penetrantes/terapia , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Medios de Contraste , Embolización Terapéutica , Femenino , Hematoma/etiología , Hematoma/terapia , Humanos , Infarto/terapia , Puntaje de Gravedad del Traumatismo , Masculino , Persona de Mediana Edad , Sensibilidad y Especificidad , Bazo/irrigación sanguínea , Enfermedades del Bazo/etiología , Enfermedades del Bazo/terapia , Factores de Tiempo , Tomografía Computarizada por Rayos X , Ultrasonografía/métodos , Heridas no Penetrantes/complicaciones , Adulto Joven
11.
Arch Ital Urol Androl ; 90(2): 143-144, 2018 Jun 30.
Artículo en Inglés | MEDLINE | ID: mdl-29974733

RESUMEN

Penile trauma represents a urological emergency characterized by the breaking of the albuginea tunic. A fast diagnosis and early surgical repair are the best treatments to avoid post-operative sequelae such as curvatures or deformities of the penis. An ultrasound evaluation may not be able to identify the injury in the tunica albuginea due to the edematous swelling of the penis and clots within the tear deteriorate the image contrast and can hide the injury. We here report a case study of successful management via surgical treatment for rupture of the cavernous body diagnosed by contrast-enhanced ultrasound in a young patient with penile trauma.


Asunto(s)
Pene/diagnóstico por imagen , Pene/lesiones , Ultrasonografía/métodos , Adulto , Medios de Contraste , Edema/etiología , Edema/terapia , Servicios Médicos de Urgencia , Humanos , Masculino , Pene/cirugía , Rotura/cirugía , Procedimientos Quirúrgicos Urológicos Masculinos
12.
J Ultrasound Med ; 36(3): 505-511, 2017 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-28098400

RESUMEN

OBJECTIVES: To evaluate the diagnostic performance of contrast-enhanced sonography for characterization of the lymph node status (metastatic or not) in patients with breast carcinomas by comparison with sentinel lymph node biopsy. METHODS: From January to August 2015, 50 female patients with a histologic diagnosis of invasive breast carcinoma were prospectively examined by ipsilateral axillary contrast-enhanced sonography. The test was performed by a single radiologist using an ultrasound system with a broadband 8-12-MHz, 38-mm high-resolution linear transducer. For the target lymph node, we chose a node with a sonographic pattern that was suspicious for malignancy: ie, a longitudinal-to-transverse diameter ratio of less than 2, absence of a central hyperechogenic hilum, or both. In cases with a lack of sonographic signs of malignancy, we evaluated the node with the maximal transverse diameter. Nodes were considered malignant in cases with total absence of contrast enhancement and in those with enhancement alterations. Within 1 week, all patients underwent sentinel lymph node biopsy, followed by a histologic test. RESULTS: The histologic test showed benignity in 22 of 50 sentinel lymph nodes, whereas 28 were metastatic. Among the 22 patients with negative biopsy results, contrast-enhanced sonography showed 18 concordances and 4 false-positives results; among the 28 with positive biopsy results, contrast-enhanced sonography obtained 100% correct characterizations of the axillary status. The sensitivity, specificity, and accuracy were 100%, 82%, and 92%, respectively. CONCLUSIONS: Contrast-enhanced sonography appears to be a method with high accuracy for characterization of axillary lymph nodes, very close to the reference-standard sentinel lymph node biopsy. This technique seems to have overall high sensitivity.


Asunto(s)
Neoplasias de la Mama/patología , Medios de Contraste , Aumento de la Imagen/métodos , Ganglios Linfáticos/diagnóstico por imagen , Ultrasonografía/métodos , Adulto , Anciano , Axila , Femenino , Humanos , Metástasis Linfática , Persona de Mediana Edad , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Biopsia del Ganglio Linfático Centinela
13.
Br J Radiol ; 96(1148): 20221026, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-37183830

RESUMEN

OBJECTIVE: To investigate the feasibility of an ultra-low radiation dose and contrast volume protocol using third-generation dual-source (DS) CT for transcatheter aortic valve implantation (TAVI) planning with coronary artery disease (CAD) assessment, coronary artery calcium score (CACS) and aortic valve calcium score (AVCS) quantification and to evaluate their relationship with TAVI outcome. METHODS: In this retrospective study were selected 203 patients (131 males, 79.4 ± 5.4 years) underwent to TAVI and at 30- and 90-day follow-up. All patients had performed a third-generation 2 × 192-slices DSCT. The CT protocol included a non-contrast and a contrast high-pitch aortic acquisition for TAVI planning and CAD assessment. Semi-qualitative and quantitative image analysis were performed; the performance in CAD assessment was compared with ICA; the relationship between AVCS and CACS and paravalvular aortic regurgitation (PAR) and major cardiovascular events (MACEs) were evaluated. Mean radiation dose were calculated. Non-parametric tests were used. RESULTS: Semi-qualitative image analysis was good. Contrast enhancement >500 Hounsfield unit (HU) and contrast-to-noise ratio <20 were obtained in all segments. The diagnostic accuracy in CAD was 89.0%. AVCS was significantly higher in patients with 30-day severe PAR. AVCS and CACS were higher in patients with 90-day MACE complications, respectively, 1904.5 ± 621.3 HU (p < 0.0001) and 769.2 ± 365.5 HU (p < 0.0230). Mean radiation dose was 2.8 ± 0.3 mSv. CONCLUSION: A TAVI planning ultra-low radiation dose and contrast volume protocol using third-generation DSCT provides highly diagnostic images with CAD assessment, AVCS and CACS quantification and these latter were related with TAVI outcomes. ADVANCES IN KNOWLEDGE: The proposed protocol using third-generation 2 × 192-slices DSCT allows with an ultra-low radiation dose and contrast volume the TAVI planning and the coronary artery assessment.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Estenosis de la Válvula Aórtica , Enfermedad de la Arteria Coronaria , Reemplazo de la Válvula Aórtica Transcatéter , Masculino , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Estudios Retrospectivos , Calcio , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Tomografía Computarizada de Haz Cónico , Dosis de Radiación
14.
Radiol Case Rep ; 18(8): 2645-2648, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-37287722

RESUMEN

Rhabdomyoma is the most common primary cardiac tumor in pediatric patients. A strong association exists between cardiac rhabdomyomas and tuberous sclerosis (TS), an autosomal dominant disease, characterized by diffuse lesions in the nervous system, such as cortical-subcortical tubers and subependymal nodules. In TS, cardiac rhabdomyomas typically are diagnosed in childhood, but they could be detected in the neonatal period with echocardiography and magnetic resonance imaging and may precede cerebral lesions. Therefore, the precocious detection of cardiac rhabdomyomas in pediatric patients can suggest the diagnosis of TS and the early detection of cerebral lesions, improving the management of the related symptoms. We reported the cases of 4 pediatric patients, in which the detection of cardiac rhabdomyomas lead to the early discovery of cerebral lesions and the diagnosis of the TS.

15.
J Belg Soc Radiol ; 106(1): 57, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35757498

RESUMEN

Objectives: Cystic fibrosis transmembrane conductance regulator (CFTR) modulator therapy effects on respiratory function, pulmonary exacerbations and quality of life have been well documented. However, CFTR modulator therapy effects on sinus disease have not been so well reported. A previous study reported that ivacaftor improves appearance of sinus disease on Computed Tomography (CT) in cystic fibrosis (CF) patients with G551D mutation. The aim of this study was to evaluate the effect of CFTR modulator therapy in sinus disease using CT scores in a wider CF patient population. Materials and Methods: Forty-eight adult patients with CF underwent at least one CT sinus examination before CFTR modulator therapy (ivacaftor, lumacaftor, ivacaftor/lumacaftor or elexcaftor/tezacaftor/ivacaftor) and one CT sinus examination one year after CFTR modulator therapy initiation. Two radiologists assessed the images in consensus. The Lund-Mackay score (LM score) and the Sheikh-Lind CT sinus disease severity scoring system (SL score) were used. The 22-item SinoNasal Outcome Test (SNOT-22) questionnaire was evaluated before CFTR modulator therapy and one year after CFTR modulator therapy initiation. Results: CT sinus examination after CFTR modulator therapy showed statistically significant lower mean LM, SL and SNOT-22 scores than CT sinus examination before CFTR modulator therapy (p < 0.001). Conclusion: Evolution of imaging findings on CT during follow-up closely correlate with improved SNOT-22 score one year after CFTR modulator therapy initiation, indicating that CT may be a useful adjunct during follow-up of CF patients under this treatment as an objective measure of sinonasal disease improvement.

16.
Artículo en Inglés | MEDLINE | ID: mdl-35339127

RESUMEN

INTRODUCTION: Paraneoplastic pemphigus (PNP) is an autoimmune disorder that is almost always linked to an underlying neoplasia. General radiologists are usually not aware of what kind of neoplasia can be associated with PNP. Therefore, this study evaluates the effect of a dermatology lecture on radiologists' neoplasia diagnosis performance. METHODS: Two radiologists evaluated thoracoabdominal computed tomography (CT) examination images of 43 patients with PNP in separate reading sessions blinded to each other's assessments. Six months after the first CT image evaluation session, the two radiologists attended a lecture by two dermatologists about PNP, and 6 months later the two radiologists assessed the same CT examinations again. RESULTS: Statistical analysis showed statistically significant differences in CT sensitivity between the first and the second round of image evaluation for both radiologists (reader 1: p = 0.0313; reader 2: p = 0.0156). CONCLUSIONS: This is the first study to evaluate the effectiveness of a dermatology lecture on diagnostic performance. It is very important for radiologists to be familiar with the particular neoplasms that can be associated with PNP because this can have a direct clinical impact on diagnostic performance.


Asunto(s)
Enfermedades Autoinmunes , Neoplasias , Síndromes Paraneoplásicos , Pénfigo , Humanos , Síndromes Paraneoplásicos/diagnóstico por imagen , Síndromes Paraneoplásicos/etiología , Pénfigo/diagnóstico por imagen , Pénfigo/etiología , Tomografía Computarizada por Rayos X
17.
Radiol Case Rep ; 16(11): 3321-3325, 2021 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-34367386

RESUMEN

Myopericarditis following mRNA Covid-19 vaccination has recently been reported to health authorities in a lot of countries. They can occur in very rare cases after either the Moderna (mRNA-1273 - Spikevax) or Pfizer-BioNTech (BNT162b2 - Comirnaty) vaccination. Cases predominately occur in younger adult men within 14 days following the second dose. In this article, we present a 56 year-old man with no prior medical history, whit the exception of a mild Covid-19 infection 4 months earlier, who experienced an episode of acute epigastric pain, profuse sweating, tachycardia, hypotension 4 days after the first dose of BNT162b2 vaccine. Troponin I level was elevated. Chest X-ray, electrocardiogram, echocardiogram, coronary angiography didn't show significant abnormalities. Cardiac Magnetic Resonance showed a pattern of acute myocarditis. The condition appeared to be self-limited and the patient recovered without specific therapy. No report of acute myocarditis was observed in the BNT162b2 and mRNA-1273 trials and very rare cases, in comparison to given doses, have been reported to pharmacovigilance systems worldwide. Further surveillance and evaluation of this side effect are warranted to establish the correct balance of benefits and risks of Covid-19 mRNA vaccines, above all in children and younger people (categories with the higher reactogenicity and the lower risk of Covid-19 complications). At the present time the benefits of Covid-19 vaccination significantly exceed possible risks.

18.
Breast Dis ; 40(4): 283-286, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34092581

RESUMEN

We present a case of ductal carcinoma in situ within a fibroadenoma. Breast cancer arising within fibroadenoma incidence ranges from 0.125% to 0.02%, and ductal carcinoma in situ is not the most frequent malignancy that can be found within a fibroadenoma. Dynamic contrast-enhanced magnetic resonance imaging showed an oval mass with circumscribed margins and dark internal septations, suspicious for fibroadenoma. According to European Society of Breast Radiology diffusion-weighted imaging consensus, mean apparent diffusion coefficient value obtained by drawing a small region of interest on the lesion apparent diffusion coefficient map showed a low diffusion level. Therefore, ductal carcinoma in situ within a fibroadenoma was diagnosed at final pathology after surgical excision.


Asunto(s)
Neoplasias de la Mama/patología , Carcinoma Intraductal no Infiltrante/patología , Fibroadenoma/patología , Neoplasias Primarias Múltiples/patología , Neoplasias de la Mama/diagnóstico por imagen , Carcinoma Intraductal no Infiltrante/diagnóstico por imagen , Medios de Contraste , Femenino , Fibroadenoma/diagnóstico por imagen , Humanos , Imagen por Resonancia Magnética , Persona de Mediana Edad , Neoplasias Primarias Múltiples/diagnóstico por imagen
19.
Med Ultrason ; 22(3): 356-363, 2020 Sep 05.
Artículo en Inglés | MEDLINE | ID: mdl-32190859

RESUMEN

In North America and Europe, syphilis incidence has increased dramatically in the past decade among high-risk groups. Syphilis may occur in any organ, including the testis. There are not many cases of testicular syphilis assessed by means ofultrasound examination described in the literature, and in no case was the evaluation carried out using advanced ultrasound techniques. Here we present a case of testicular syphilis evaluated by contrast-enhanced ultrasound.


Asunto(s)
Medios de Contraste , Aumento de la Imagen/métodos , Sífilis/complicaciones , Sífilis/diagnóstico , Neoplasias Testiculares/diagnóstico por imagen , Neoplasias Testiculares/etiología , Ultrasonografía/métodos , Adulto , Antibacterianos , Humanos , Masculino , Fosfolípidos , Hexafluoruro de Azufre , Sífilis/tratamiento farmacológico , Neoplasias Testiculares/tratamiento farmacológico , Testículo/diagnóstico por imagen
20.
Med Ultrason ; 21(1): 16-21, 2019 Feb 17.
Artículo en Inglés | MEDLINE | ID: mdl-30779826

RESUMEN

AIMS: To assess contrast enhanced ultrasound (CEUS) performance in the prediction of non-operatively managed blunt spleen injuries requiring only observation and monitoring during follow-up and to evaluate if CEUS accuracy was higher than conventional ultrasound (US) in this field. MATERIAL AND METHODS: In 112 hemodynamic stable blunt spleen trauma patients, CEUS was performed for follow-up after computed tomography evaluation in the emergency department. CEUS and US performance were assessed considering as true negative cases patients that had not underwent interventional or surgical treatment during follow-up and were assessed as negative for splenic complications respectively by CEUS or US examinations. RESULTS:  CEUS showed sensitivity of 100%, specificity of 96.1%, positive predictive value of 69.2%, negative predictive value of 100.0% and accuracy of 96.4%. CEUS showed a significantly higher accuracy than conventional US (p=0.013). CONCLUSIONS:  CEUS is a very useful imaging modality during follow-up of blunt splenic trauma non-operatively managed, allowing an efficientprediction of splenic injuries requiring only observation and monitoring during follow-up.


Asunto(s)
Medios de Contraste , Aumento de la Imagen/métodos , Bazo/diagnóstico por imagen , Bazo/lesiones , Ultrasonografía/métodos , Heridas no Penetrantes/diagnóstico por imagen , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA