Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros

Bases de datos
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
PLoS One ; 11(3): e0151775, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-26999048

RESUMEN

Precision medicine promises to enhance patient treatment through the use of emerging molecular technologies, including genomics, transcriptomics, and proteomics. However, current tools in surgical pathology lack the capability to efficiently isolate specific cell populations in complex tissues/tumors, which can confound molecular results. Expression microdissection (xMD) is an immuno-based cell/subcellular isolation tool that procures targets of interest from a cytological or histological specimen. In this study, we demonstrate the accuracy and precision of xMD by rapidly isolating immunostained targets, including cytokeratin AE1/AE3, p53, and estrogen receptor (ER) positive cells and nuclei from tissue sections. Other targets procured included green fluorescent protein (GFP) expressing fibroblasts, in situ hybridization positive Epstein-Barr virus nuclei, and silver stained fungi. In order to assess the effect on molecular data, xMD was utilized to isolate specific targets from a mixed population of cells where the targets constituted only 5% of the sample. Target enrichment from this admixed cell population prior to next-generation sequencing (NGS) produced a minimum 13-fold increase in mutation allele frequency detection. These data suggest a role for xMD in a wide range of molecular pathology studies, as well as in the clinical workflow for samples where tumor cell enrichment is needed, or for those with a relative paucity of target cells.


Asunto(s)
Secuenciación de Nucleótidos de Alto Rendimiento/métodos , Microdisección/métodos , Animales , Núcleo Celular/metabolismo , Epitelio/metabolismo , Humanos , Ratones , Células 3T3 NIH , Coloración y Etiquetado
2.
Am J Cancer Res ; 3(4): 402-10, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-23977449

RESUMEN

In a recent study, a unique gene expression signature was observed when comparing esophageal squamous cell carcinoma (ESCC) epithelial cells to normal esophageal epithelial cells using laser capture microdissection (LCM) and cDNA microarray technology. To validate the expression of several intriguing genes from that study (KRT17, cornulin, CD44, and EpCAM), we employed two new technologies, expression microdissection (xMD) for high-throughput microdissection facilitating protein analysis and RNAscope for the evaluation of low abundant transcripts in situ. For protein measurements, xMD technology was utilized to specifically procure sufficient tumor and normal epithelium from frozen human tissue for immunoblot analysis of KRT17 (CK17) and cornulin. A novel in situ hybridization method (RNAscope) was used to determine the transcript level of two relatively low expressed genes, CD44 and EpCAM in both individual formalin-fixed paraffin-embedded (FFPE) tissue sections and in an ESCC tissue microarray (TMA). The results successfully confirmed the initial expression pattern observed for all four genes, potentially implicating them in the pathogenesis of ESCC. Additionally, the study provides important methodological information on the overall process of candidate gene validation.

3.
Nat Protoc ; 6(4): 457-67, 2011 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-21412274

RESUMEN

Laser-based microdissection facilitates the isolation of specific cell populations from clinical or animal model tissue specimens for molecular analysis. Expression microdissection (xMD) is a second-generation technology that offers considerable advantages in dissection capabilities; however, until recently the method has not been accessible to investigators. This protocol describes the adaptation of xMD to commonly used laser microdissection instruments and to a commercially available handheld laser device in order to make the technique widely available to the biomedical research community. The method improves dissection speed for many applications by using a targeting probe for cell procurement in place of an operator-based, cell-by-cell selection process. Moreover, xMD can provide improved dissection precision because of the unique characteristics of film activation. The time to complete the protocol is highly dependent on the target cell population and the number of cells needed for subsequent molecular analysis.


Asunto(s)
Rayos Láser , Microdisección/métodos , Separación Celular , Técnica del Anticuerpo Fluorescente , Inmunohistoquímica/métodos , Microdisección/instrumentación , Polivinilos/química
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA