Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 36
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
N Engl J Med ; 387(25): 2356-2361, 2022 12 22.
Artículo en Inglés | MEDLINE | ID: mdl-36546627

RESUMEN

A 27-year-old patient with a history of severe obstetrical complications and arterial thrombosis received a diagnosis of hereditary thrombotic thrombocytopenic purpura (TTP) due to severe ADAMTS13 deficiency when she presented with an acute episode in the 30th week of her second pregnancy. When the acute episode of hereditary TTP became plasma-refractory and fetal death was imminent, weekly injections of recombinant ADAMTS13 at a dose of 40 U per kilogram of body weight were initiated. The patient's platelet count normalized, and the growth of the fetus stabilized. At 37 weeks 1 day of gestation, a small-for-gestational-age boy was delivered by cesarean section. At the time of this report, the patient and her son were well, and she continued to receive injections of recombinant ADAMTS13 every 2 weeks. (Funded by the Swiss National Science Foundation.).


Asunto(s)
Complicaciones Hematológicas del Embarazo , Púrpura Trombocitopénica Trombótica , Adulto , Femenino , Humanos , Embarazo , Proteína ADAMTS13/administración & dosificación , Proteína ADAMTS13/deficiencia , Proteína ADAMTS13/genética , Proteína ADAMTS13/uso terapéutico , Cesárea , Plasma , Recuento de Plaquetas , Púrpura Trombocitopénica Trombótica/diagnóstico , Púrpura Trombocitopénica Trombótica/genética , Púrpura Trombocitopénica Trombótica/terapia , Resultado del Embarazo , Complicaciones Hematológicas del Embarazo/genética , Complicaciones Hematológicas del Embarazo/terapia
2.
Transfusion ; 59(5): 1818-1826, 2019 05.
Artículo en Inglés | MEDLINE | ID: mdl-30719724

RESUMEN

BACKGROUND: Fibrinogen supplementation during bleeding restores clot strength and hemostasis. Cryoprecipitate, a concentrated source of fibrinogen, has prolonged preparation time for thawing, a short shelf life resulting in frequent wastage, and infectious disease risk. This in vitro study investigated the efficacy of a new pathogen-reduced cryoprecipitate thawed and stored at room temperature for 5 days (PR Cryo) to treat dilutional hypofibrinogenemia, compared to immediately thawed standard cryoprecipitate (Cryo) or fibrinogen concentrate (FC). STUDY DESIGN AND METHODS: Ten phlebotomy specimens from healthy volunteers were diluted 1:1 with crystalloid and supplemented with PR Cryo and Cryo (at a dose replicating transfusion of two pooled doses [10 units]) and FC at a dose replicating 50 mg/kg. Changes in clot firmness (thromboelastometry) and in coagulation factor activity were assessed at baseline, after dilution, and after supplementation. RESULTS: Clinical dosing was used, as described above, and consequently the FC dose contained 24% and 36% more fibrinogen versus PR Cryo and Cryo, respectively. At baseline, subjects had a median FIBTEM maximum clot firmness of 13.5 mm, versus 6.5 mm after 50% dilution (p = 0.005). After supplementation with PR Cryo, a median FIBTEM maximum clot firmness of 13 mm was observed versus 9.0 mm for Cryo (p = 0.005) or 16.5 mm for FC (p = 0.005). Median factor XIII was higher after PR Cryo (64.8%) versus Cryo (48.3%) (p = 0.005). Fibrinogen activity was higher after FC (269.0 mg/dL) versus PR Cryo (187.0 mg/dL; p = 0.005) or Cryo (193.5 mg/dL; p = 0.005); the difference between PR Cryo and Cryo supplementation (p = 0.445) was not significant. CONCLUSION: PR Cryo used 5 days after thawing effectively restores clot strength after in vitro dilution.


Asunto(s)
Trastornos de la Coagulación Sanguínea/terapia , Adulto , Trastornos de la Coagulación Sanguínea/tratamiento farmacológico , Femenino , Fibrinógeno/uso terapéutico , Voluntarios Sanos , Hemorragia/tratamiento farmacológico , Hemorragia/terapia , Humanos , Masculino , Temperatura , Tromboelastografía
3.
Scand J Clin Lab Invest ; 78(3): 230-235, 2018 05.
Artículo en Inglés | MEDLINE | ID: mdl-29446989

RESUMEN

Both congenital and acquired fibrinogen deficiency can be safely treated with administration of fibrinogen concentrate. The aim of this study was to test the efficacy of a new fibrinogen product (Fibryga) compared to a licensed product (Haemocomplettan) in an in vitro model of dilutional coagulopathy. Ten blood specimens from healthy volunteers were diluted 1:1 with balanced crystalloid solution and subsequently supplemented with each fibrinogen concentrate at a dose replicating in vivo supplementation (50 mg kg-1). Changes in clot firmness (FIBTEM and EXTEM assay), as well as changes in the fibrinogen antigen level, fibrinogen activity, factor XIII level and fibronectin levels were assessed at baseline, after dilution and after adding fibrinogen concentrate. There was no significant difference between the drugs in their in vitro ability to improve clot firmness in the FIBTEM assay (Fibryga: mean MCF 14.4 mm (SD 3.4 mm) vs. Haemocomplettan: MCF 14.1 mm (2.4); p = .584). Fibryga led to significantly higher clot firmness in EXTEM MCF: 56.7 mm (3.8) vs. 53.7 mm (3.7); p < .001). Distinct differences between FXIII levels (significantly higher in Fibryga; mean 40.9% (6.2%) vs. 31.0% (6.2%); p < .001) and fibronectin levels (significantly higher in Haemocomplettan; mean 0.008 g L-1 (SD 0.002 g L-1) vs. 0.002 g L-1 (SD 0.002 g L-1; p < .001) were observed between products. This is the first study to demonstrate that Fibryga and Haemocomplettan have similar efficacy in improving clot firmness in a dilutional hypofibrinogenemia model in vitro.


Asunto(s)
Pruebas de Coagulación Sanguínea/normas , Fibrinógeno/farmacología , Hemostáticos/farmacología , Tromboelastografía/normas , Adolescente , Adulto , Afibrinogenemia/sangre , Afibrinogenemia/diagnóstico , Anciano , Anciano de 80 o más Años , Coagulación Sanguínea , Trastornos de la Coagulación Sanguínea/sangre , Trastornos de la Coagulación Sanguínea/diagnóstico , Pruebas de Coagulación Sanguínea/instrumentación , Factor XIII/farmacología , Femenino , Fibrinógeno/metabolismo , Fibronectinas/sangre , Voluntarios Sanos , Humanos , Masculino , Persona de Mediana Edad , Tromboelastografía/instrumentación
4.
Transfusion ; 57(10): 2502-2510, 2017 10.
Artículo en Inglés | MEDLINE | ID: mdl-28734018

RESUMEN

BACKGROUND: Hyperfibrinolysis is a potentially life-threatening condition associated with poor clot integrity and excessive bleeding. Although antifibrinolytics are an effective treatment, more liberal use of these drugs may lead to a prothrombotic risk, and an earlier and potentially safer treatment option would be desirable. Hyperfibrinolysis has been shown to be attenuated by in vitro supplementation of purified human Factor (F)XIII concentrate. Cryoprecipitate represents an alternative source of FXIII and the only approved source of concentrated FXIII in some countries. The aim of this study was to investigate whether cryoprecipitate, FXIII, and fibrinogen concentrate mitigate hyperfibrinolysis. STUDY DESIGN AND METHODS: Ten citrate blood specimens from healthy subjects were spiked with tissue plasminogen activator (t-PA) and subsequently supplemented with cryoprecipitate, FXIII, fibrinogen concentrate, and ɛ-aminocaproic acid (EACA). Thromboelastometry tests were performed at baseline, after t-PA, and after supplementation. Hyperfibrinolysis was assessed using the clot lysis index at 60 minutes (LI60; reciprocal of maximum lysis). RESULTS: The LI60 was significantly improved (fibrinolysis attenuated) after cryoprecipitate supplementation compared to t-PA alone and compared to FXIII and fibrinogen concentrate. Hyperfibrinolysis was only fully reversed using EACA. In addition, cryoprecipitate demonstrated the least variability in the attenuation of hyperfibrinolysis among 10 healthy subjects, compared to FXIII and fibrinogen concentrate. CONCLUSION: This is the first study to show that cryoprecipitate is able to significantly mitigate hyperfibrinolysis in an in vitro model. Further investigations are warranted to determine whether cryoprecipitate may have a previously unrecognized benefit and should be administered earlier in resuscitation protocols.


Asunto(s)
Factor VIII/farmacología , Fibrinógeno/farmacología , Fibrinólisis/efectos de los fármacos , Ácido Aminocaproico/farmacología , Recolección de Muestras de Sangre , Factor VIII/uso terapéutico , Factor XIII , Fibrinógeno/uso terapéutico , Humanos , Tromboelastografía , Activador de Tejido Plasminógeno/farmacología
6.
Scand J Clin Lab Invest ; 76(6): 503-7, 2016 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-27354213

RESUMEN

Recent years have seen increasing worldwide interest in the use of viscoelastic coagulation monitoring tests, performed using devices such as ROTEM and TEG. The use of such tests to guide haemostatic therapy may help reduce transfusion of allogeneic blood products in bleeding patients and is supported in European guidelines for managing trauma and severe perioperative bleeding. In addition, viscoelastic tests form the basis of numerous published treatment algorithms. However, some publications have stated that viscoelastic tests are not validated. A specific definition of the term validation is lacking and regulatory requirements of the US Food and Drug Administration (FDA) and European Medicines Agency (EMA) have been fulfilled by ROTEM and TEG assays. Viscoelastic tests have been used in pivotal clinical trials, and they are approved for use in most of the world's countries. Provided that locally approved indications are adhered to, the regulatory framework for clinicians to use viscoelastic tests in routine clinical practice is in place.


Asunto(s)
Trastornos de la Coagulación Sanguínea/diagnóstico , Pruebas de Coagulación Sanguínea , Trastornos de la Coagulación Sanguínea/sangre , Elasticidad , Humanos , Estudios de Validación como Asunto , Viscosidad
8.
Thromb J ; 11(1): 6, 2013 Mar 07.
Artículo en Inglés | MEDLINE | ID: mdl-23496906

RESUMEN

BACKGROUND: While the assessment of analytical precision within medical laboratories has received much attention in scientific enquiry, the degree of as well as the sources causing variation between them remains incompletely understood. In this study, we quantified the variance components when performing coagulation tests with identical analytical platforms in different laboratories and computed intraclass correlations coefficients (ICC) for each coagulation test. METHODS: Data from eight laboratories measuring fibrinogen twice in twenty healthy subjects with one out of 3 different platforms and single measurements of prothrombin time (PT), and coagulation factors II, V, VII, VIII, IX, X, XI and XIII were analysed. By platform, the variance components of (i) the subjects, (ii) the laboratory and the technician and (iii) the total variance were obtained for fibrinogen as well as (i) and (iii) for the remaining factors using ANOVA. RESULTS: The variability for fibrinogen measurements within a laboratory ranged from 0.02 to 0.04, the variability between laboratories ranged from 0.006 to 0.097. The ICC for fibrinogen ranged from 0.37 to 0.66 and from 0.19 to 0.80 for PT between the platforms. For the remaining factors the ICC's ranged from 0.04 (FII) to 0.93 (FVIII). CONCLUSIONS: Variance components that could be attributed to technicians or laboratory procedures were substantial, led to disappointingly low intraclass correlation coefficients for several factors and were pronounced for some of the platforms. Our findings call for sustained efforts to raise the level of standardization of structures and procedures involved in the quantification of coagulation factors.

9.
Anesth Analg ; 117(5): 1054-62, 2013 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-24108255

RESUMEN

BACKGROUND: The viscoelastic functional fibrinogen (FF) and FIBTEM assays measure the contribution of fibrin to clot strength. Inhibition of platelet function is a necessary precondition for these tests to work. We investigated a novel test for measuring fibrin-based clotting, FIBTEM PLUS, in cardiac surgery and compared it with FF and FIBTEM. METHODS: A prospective, observational study was performed which included 30 patients undergoing cardiac surgery with cardiopulmonary bypass (CPB). Blood samples were drawn at the beginning of surgery (pre-CPB), approximately 20 minutes before weaning from CPB and 5 minutes after heparin neutralization. FF, FIBTEM, and FIBTEM PLUS tests were performed in duplicate for all blood samples. Additional coagulation parameters, including platelet count, plasma fibrinogen levels, factor XIII activity, and heparin concentration, were also recorded for each sample. RESULTS: At all time points, the lowest mean maximum clot firmness (MCF) was observed with FIBTEM PLUS, although a statistically significant difference between FIBTEM and FIBTEM PLUS was observed only at baseline (mean values 22 vs 19 mm, P = 0.01; FF value for comparison: 27.7 mm). FF maximum amplitude (MA) values were significantly higher than FIBTEM MCF and FIBTEM PLUS MCF pre-CPB, during CPB and after heparin neutralization (P ≤ 0.001 for FF MA versus FIBTEM MCF and for FF MA versus FIBTEM PLUS MCF at all time points). The difference between FIBTEM MCF and FIBTEM PLUS MCF correlated with platelet count (r = 0.46;P < 0.001), whereas differences between FF MA and FIBTEM MCF, or FF MA and FIBTEM PLUS MCF did not (r = -0.07, P = 0.51; r = 0.16, P = 0.12, respectively). Differences between the assays were unrelated to heparin levels, which decreased considerably after protamine administration compared with heparin levels recorded before weaning from CPB (decrease from 2.1 to 0.1 U/mL and from 2.8 to 0.2 U/mL for anti-factor IIa and anti-factor Xa, respectively). Agreement between duplicate measurements was similar with FIBTEM and FIBTEM PLUS assays and lower with FF. Significant positive correlations were found between MCF or MA and fibrinogen concentration (all P < 0.001); the highest correlation was with FIBTEM PLUS MCF (r = 0.70). CONCLUSION: The FIBTEM PLUS assay produces precise results. At baseline, it provides greater inhibition of platelets than FIBTEM, but there is no meaningful difference between FIBTEM PLUS and FIBTEM in patients with low platelet counts.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos/instrumentación , Fibrina/análisis , Fibrina/química , Fibrinógeno/análisis , Tromboelastografía/métodos , Anciano , Coagulación Sanguínea , Pruebas de Coagulación Sanguínea , Plaquetas/fisiología , Procedimientos Quirúrgicos Cardíacos/métodos , Puente de Arteria Coronaria/instrumentación , Puente de Arteria Coronaria/métodos , Elasticidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Viscosidad
10.
Eur Surg Res ; 50(1): 14-23, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-23429206

RESUMEN

BACKGROUND/PURPOSE: It has been substantiated that the quality of pleurodesis is reduced when non-steroidal anti-inflammatory drugs (NSAIDs) are used perioperatively. The effects of NSAID administration on the early inflammatory and fibrinolytic processes after mechanical pleurodesis were investigated in an established pig model. METHODS: Left-sided mechanical pleural abrasion was performed on 24 pigs assigned to either an NSAID or a control group. Pleural fluid and blood samples were analysed over a 24-hour period. Histological evaluation of neutrophil influx at the site of pleural abrasion was performed. RESULTS: The volume of pleural effusion was significantly decreased in the diclofenac group at 10 and 24 h, and the protein content was significantly lower. The diclofenac group at 24 h had a diminished total number of white blood cells and a reduced content of transforming growth factor-ß. Moreover, the diclofenac group had a reduced percentage of neutrophils at 6 h. Significantly increased levels of D-dimers and tissue plasminogen activator were measured at 6 h and of interleukin-10 at 24 h. Neutrophils at the site of pleural abrasion were significantly reduced. CONCLUSIONS: Systemic application of diclofenac led to a local enhancement of fibrinolysis and attenuation of pro-inflammatory and fibrotic processes necessary for adhesion formation in our model.


Asunto(s)
Antiinflamatorios no Esteroideos/efectos adversos , Diclofenaco/efectos adversos , Fibrinólisis/efectos de los fármacos , Pleurodesia , Animales , Citocinas/sangre , Mediadores de Inflamación/sangre , Pleura/inmunología , Porcinos , Cirugía Torácica Asistida por Video
11.
Blood Coagul Fibrinolysis ; 33(5): 239-256, 2022 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-35703225

RESUMEN

During sepsis, an initial prothrombotic shift takes place, in which coagulatory acute-phase proteins are increased, while anticoagulatory factors and platelet count decrease. Further on, the fibrinolytic system becomes impaired, which contributes to disease severity. At a later stage in sepsis, coagulation factors may become depleted, and sepsis patients may shift into a hypo-coagulable state with an increased bleeding risk. During the pro-coagulatory shift, critically ill patients have an increased thrombosis risk that ranges from developing micro-thromboses that impair organ function to life-threatening thromboembolic events. Here, thrombin plays a key role in coagulation as well as in inflammation. For thromboprophylaxis, low molecular weight heparins (LMWH) and unfractionated heparins (UFHs) are recommended. Nevertheless, there are conditions such as heparin resistance or heparin-induced thrombocytopenia (HIT), wherein heparin becomes ineffective or even puts the patient at an increased prothrombotic risk. In these cases, argatroban, a direct thrombin inhibitor (DTI), might be a potential alternative anticoagulatory strategy. Yet, caution is advised with regard to dosing of argatroban especially in sepsis. Therefore, the starting dose of argatroban is recommended to be low and should be titrated to the targeted anticoagulation level and be closely monitored in the further course of treatment. The authors of this review recommend using DTIs such as argatroban as an alternative anticoagulant in critically ill patients suffering from sepsis or COVID-19 with suspected or confirmed HIT, HIT-like conditions, impaired fibrinolysis, in patients on extracorporeal circuits and patients with heparin resistance, when closely monitored.


Asunto(s)
COVID-19 , Sepsis , Trombocitopenia , Trombosis , Tromboembolia Venosa , Anticoagulantes/efectos adversos , Arginina/análogos & derivados , Enfermedad Crítica , Heparina/efectos adversos , Heparina de Bajo-Peso-Molecular/uso terapéutico , Humanos , Ácidos Pipecólicos , Sepsis/tratamiento farmacológico , Sulfonamidas , Trombocitopenia/inducido químicamente , Trombosis/tratamiento farmacológico , Trombosis/etiología , Trombosis/prevención & control , Tromboembolia Venosa/tratamiento farmacológico
12.
Front Cardiovasc Med ; 9: 817826, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35369293

RESUMEN

Background: Applying a single anti-Xa assay, calibrated to unfractionated heparin to measure rivaroxaban, apixaban, and edoxaban would simplify laboratory procedures and save healthcare costs. Aim: We hypothesized that a heparin-calibrated anti-Xa assay would accurately measure rivaroxaban, apixaban, and edoxaban drug concentrations and correctly predict clinically relevant drug levels. Methods: This analysis is part of the Simple-Xa study, a prospective multicenter cross-sectional study conducted in clinical practice. Patients treated with rivaroxaban, apixaban, or edoxaban were included. Anti-Xa activity was measured using the Siemens INNOVANCE® Heparin assay. Drug concentrations were determined using ultra-high performance liquid chromatography-tandem mass spectrometry (LC-MS/MS). Cut-off levels were determined in a derivation dataset (50% of patients) and sensitivities and specificities were calculated in a verification dataset (50% of patients). Results: Overall, 845 patients were available for analysis. Correlation coefficients (r s ) between the heparin-calibrated anti-Xa assay and drug concentrations were 0.97 (95% CI 0.97, 0.98) for rivaroxaban, 0.96 (0.96, 0.97) for apixaban, and 0.96 (0.94, 0.99) for edoxaban. The area under the receiver operating characteristics curve (ROC) was 0.99 for all clinically relevant drug concentrations. In the verification dataset, the sensitivity was 94.2% (95% CI 90.8-96.6) for 30 µg L-1, 95.8% (92.4-98.0) for 50 µg L-1, and 98.7% (95.5-99.9) for 100 µg L-1. Specificities were 86.3% (79.2-91.7), 89.8% (84.5-93.7), and 88.7% (84.2-92.2), respectively. Conclusion: In a large prospective study in clinical practice, a strong correlation of heparin-calibrated anti-Xa measurements with LC-MS/MS results was observed and clinically relevant drug concentrations were predicted correctly.

13.
Front Cell Infect Microbiol ; 11: 753320, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34796127

RESUMEN

Angiostrongylus vasorum is a cardiopulmonary nematode of canids and is, among others, associated with bleeding disorders in dogs. The pathogenesis of such coagulopathies remains unclear. A deep proteomic characterization of sex specific A. vasorum excretory/secretory proteins (ESP) and of cuticular surface proteins was performed, and the effect of ESP on host coagulation and fibrinolysis was evaluated in vitro. Proteins were quantified by liquid chromatography coupled to mass spectrometry and functionally characterized through gene ontology and pathway enrichment analysis. In total, 1069 ESP (944 from female and 959 from male specimens) and 1195 surface proteins (705 and 1135, respectively) were identified. Among these were putative modulators of host coagulation, e.g., von Willebrand factor type D domain protein orthologues as well as several proteases, including serine type proteases, protease inhibitors and proteasome subunits. The effect of ESP on dog coagulation and fibrinolysis was evaluated on canine endothelial cells and by rotational thromboelastometry (ROTEM). After stimulation with ESP, tissue factor and serpin E1 transcript expression increased. ROTEM revealed minimal interaction of ESP with dog blood and ESP did not influence the onset of fibrinolysis, leading to the conclusion that Angiostrongylus vasorum ESP and surface proteins are not solely responsible for bleeding in dogs and that the interaction with the host's vascular hemostasis is limited. It is likely that coagulopathies in A. vasorum infected dogs are the result of a multifactorial response of the host to this parasitic infection.


Asunto(s)
Angiostrongylus , Enfermedades de los Perros , Infecciones por Strongylida , Animales , Perros , Células Endoteliales , Femenino , Masculino , Proteoma , Proteómica
14.
Swiss Med Wkly ; 150: w20422, 2020 Dec 14.
Artículo en Inglés | MEDLINE | ID: mdl-33338252

RESUMEN

INTRODUCTION: Emicizumab (Hemlibra®, Hoffmann-La Roche, Switzerland) is now available for haemophilia A patients with or without factor VIII inhibitors. Management of bleeding events and replacement therapy for invasive procedures have to be adapted. OBJECTIVE: To provide a practical guidance for the management of breakthrough bleeding events and elective or urgent surgery in adult and paediatric patients with haemophilia A without inhibitors treated with emicizumab. METHODS: Based on the available literature and the experiences collected from adult and paediatric patients treated in Switzerland, the Working Party on Haemostasis of the Swiss Society of Haematology and the Swiss Haemophilia Network worked together to reach a consensus on the management of bleeding events and invasive procedures. RESULTS AND CONCLUSION: Minor bleeding events and invasive procedures associated with low bleeding risk can be treated without factor replacement therapy in most cases, whereas major bleeding events and high-risk surgery require additional factor VIII replacement at usual doses, at least for the first days. Emicizumab treatment should be continued throughout the procedure and during the postoperative period. Elective major surgery should be planned according to emicizumab dosing for patients with a once-a-month posology. Of note, so far only few data are available on the management of major bleeds and surgery in patients with haemophilia A treated with emicizumab and this practical guidance will have to be regularly updated with growing experience.  .


Asunto(s)
Anticuerpos Biespecíficos , Hemofilia A , Adulto , Anticuerpos Monoclonales Humanizados/uso terapéutico , Niño , Hemofilia A/tratamiento farmacológico , Hemorragia/inducido químicamente , Humanos
15.
Thromb Haemost ; 100(3): 498-504, 2008 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-18766268

RESUMEN

The clinical relevance of heparin-induced antibodies (HIA) in the absence of thrombocytopenia remains to be defined. The aims of this study were (i) to determine the prevalence of HIA in patients treated by dialysis, (ii) to determine the prevalence of thrombocytopenia and heparin-induced thrombocytopenia (HIT), and (iii) to test whether HIA are associated with adverse outcomes. Sera from 740 patients treated by hemodialysis (HD, n=596) and peritoneal dialysis (PD, n=144) were tested for HIA (IgG, IgA or IgM) by masked investigators at approximately six months after enrolment in the Choices for Healthy Outcomes in Caring for End-Stage Renal Disease (CHOICE) study. We assessed, with time-to-event Cox proportional hazards models, whether the presence of HIA predicted any of four clinical outcomes: arterial cardiovascular events, venous thromboembolism, vascular access occlusion and mortality. HIA prevalence was 10.3% overall. HIA positivity did not predict development of thrombocytopenia or any of the four clinical outcomes over a mean follow-up of 3.6 years, with hazard ratios for arterial cardiovascular events of 0.98 (95% confidence interval 0.70-1.37), venous thromboembolism 1.39 (0.17-11.5), vascular access occlusion 0.82 (0.40-1.71), and mortality 1.18 (0.85-1.64). Chronic intermittent heparin exposure was associated with a high seroprevalence of HIA. In dialysis patients these antibodies were not an independent risk factor for cardiovascular events and mortality. Our data do not suggest that dialysis patients should be monitored for HIA antibodies in the absence of thrombocytopenia.


Asunto(s)
Anticuerpos/química , Enfermedades Cardiovasculares/metabolismo , Heparina/química , Trombocitopenia/sangre , Adulto , Anciano , Enfermedades Cardiovasculares/etiología , Femenino , Heparina/metabolismo , Humanos , Inmunoglobulina A/análisis , Inmunoglobulina G/análisis , Inmunoglobulina M/análisis , Masculino , Persona de Mediana Edad , Diálisis Peritoneal , Recuento de Plaquetas , Diálisis Renal , Riesgo , Trombocitopenia/inducido químicamente
16.
Crit Care ; 12(3): R80, 2008.
Artículo en Inglés | MEDLINE | ID: mdl-18564410

RESUMEN

INTRODUCTION: Norepinephrine, regularly used to increase systemic arterial blood pressure and thus improve cerebral perfusion following severe traumatic brain injury (TBI), may activate platelets. This, in turn, could promote microthrombosis formation and induce additional brain damage. METHODS: The objective of this study was to investigate the influence of norepinephrine on platelets isolated from healthy volunteers and TBI patients during the first two post-traumatic weeks. A total of 18 female and 18 male healthy volunteers of different age groups were recruited, while 11 critically ill TBI patients admitted consecutively to our intensive care unit were studied. Arterial and jugular venous platelets were isolated from norepinephrine-receiving TBI patients; peripheral venous platelets were studied in healthy volunteers. Concentration-dependent functional alterations of isolated platelets were analyzed by flow cytometry, assessing changes in surface P-selectin expression and platelet-derived microparticles before and after in vitro stimulation with norepinephrine ranging from 10 nM to 100 microM. The thrombin receptor-activating peptide (TRAP) served as a positive control. RESULTS: During the first week following TBI, norepinephrine-mediated stimulation of isolated platelets was significantly reduced compared with volunteers (control). In the second week, the number of P-selectin- and microparticle-positive platelets was significantly decreased by 60% compared with the first week and compared with volunteers. This, however, was associated with a significantly increased susceptibility to norepinephrine-mediated stimulation, exceeding changes observed in volunteers and TBI patients during the first week. This pronounced norepinephrine-induced responsiveness coincided with increased arterio-jugular venous difference in platelets, reflecting intracerebral adherence and signs of cerebral deterioration reflected by elevated intracranial pressure and reduced jugular venous oxygen saturation. CONCLUSION: Clinically infused norepinephrine might influence platelets, possibly promoting microthrombosis formation. In vitro stimulation revealed a concentration- and time-dependent differential level of norepinephrine-mediated platelet activation, possibly reflecting changes in receptor expression and function. Whether norepinephrine should be avoided in the second post-traumatic week and whether norepinephrine-stimulated platelets might induce additional brain damage warrant further investigations.


Asunto(s)
Plaquetas/efectos de los fármacos , Lesiones Encefálicas/tratamiento farmacológico , Norepinefrina/farmacología , Activación Plaquetaria/efectos de los fármacos , Vasoconstrictores/farmacología , Adulto , Lesiones Encefálicas/patología , Estudios de Casos y Controles , Femenino , Citometría de Flujo , Humanos , Técnicas In Vitro , Unidades de Cuidados Intensivos , Hipertensión Intracraneal , Masculino , Persona de Mediana Edad , Oxígeno/sangre , Selectina-P/sangre
17.
Swiss Med Wkly ; 138(9-10): 142-9, 2008 Mar 08.
Artículo en Inglés | MEDLINE | ID: mdl-18330734

RESUMEN

AIM: This pilot study seeks to determine whether contact system activation (CSA) occurs in human sepsis patients and to characterise blood levels of the 47kD light chain of high-molecular weight kininogen (47kD HK). METHODS: Six consecutive patients with clinical suspicion of sepsis were evaluated on days 1, 2, 3 and 6-8 for 47kD HK blood levels expressed in U/ml of whole blood and as percent of total HK. 47kD HK was measured in whole blood by quantitative immunoblot analysis. RESULTS: On study day 1 or 2, analysis of 47kD HK in U/ml of whole blood identified CSA in 3/6 patients. When 47kD HK levels were expressed as percent of total HK, 4/6 patients were identified with CSA before day 3. The degree of CSA as assayed by the presence of 47kD HK correlated with the severity of the systemic inflammatory syndrome (SIRS), i.e. mean CSA increased progressively from basal levels in healthy controls (0.08 U/ml or 10.4%) to patients without SIRS (0.10 U/ml or 15.1%), to patients with sepsis (0.12 U/ml or 15.0%), and finally to patients in a combined category of severe sepsis and septic shock (0.13 U/ml or 17.4%). CONCLUSION: CSA, defined by increased 47kD HK, occurred early on in the course of sepsis in a subset of sepsis patients. 47kD HK levels, an indicator of bradykinin release, correlated with sepsis severity. Future larger studies will need to evaluate the role of 47kD HK as a biomarker for both prognosis and treatment response in human sepsis..


Asunto(s)
Immunoblotting/métodos , Quininógeno de Alto Peso Molecular/sangre , Sepsis/sangre , Biomarcadores , Pruebas de Coagulación Sanguínea , Humanos , Sepsis/fisiopatología , Índice de Severidad de la Enfermedad
18.
Thromb Res ; 153: 65-70, 2017 May.
Artículo en Inglés | MEDLINE | ID: mdl-28343143

RESUMEN

BACKGROUND: Point-of-care testing (POCT) is regularly used to assess haemostasis in various clinical settings. The impact of rivaroxaban on those POCT is still elusive. We aimed to study the effects of rivaroxaban on most commonly used POCT assays. METHODS: Blood samples were taken before, 3h, and 24h after administration of 20mg rivaroxaban to 20 healthy volunteers as part of a prospective, multicenter validation study (clinicaltrials.govNCT01710267). Blood samples were analysed with thromboelastometry (ROTEM®), two platelet function assays (INNOVANCE® PFA-200 and Multiplate®), and the CoaguChek® XS. Rivaroxaban plasma levels were determined using liquid chromatography-mass spectrometry. RESULTS: Rivaroxaban significantly modified some thromboelastometry parameters (CT INTEM: mean difference 56.1s, 95% CI: 41.8, 70.3; CT EXTEM: 47.5s, 95% CI: 37.8, 57.1; CT HEPTEM: 50.1s, 95% CI: 34.7, 65.6), and CoaguChek® XS parameters (prothrombin time: mean difference 3.8s, 95% CI: 3.3, 4.2; INR: 0.32, 95% CI: 0.27, 0.38; prothrombin ratio: -36.1%, 95% CI: -32.3, -39.9). CT EXTEM and INR showed a moderate correlation with rivaroxaban plasma levels (r=0.83; 95% CI 0.69, 0.9 and r=0.83; 95% CI 0.70, 0.91, respectively) and a high sensitivity to detect rivaroxaban treatment at peak levels (0.95; 95% CI: 0.76, 1.0 and 0.90, 95% CI 0.70, 0.99, respectively). CONCLUSIONS: Rivaroxaban 20mg treatment significantly alters ROTEM® and CoaguChek® XS parameters. Even though POCT do not allow precise quantification of rivaroxaban plasma concentration, CT EXTEM and CoaguChek XS detect the presence of rivaroxaban at peak level with a high sensitivity.


Asunto(s)
Pruebas de Coagulación Sanguínea/métodos , Inhibidores del Factor Xa/sangre , Pruebas de Función Plaquetaria/métodos , Pruebas en el Punto de Atención , Rivaroxabán/sangre , Adolescente , Adulto , Anciano , Humanos , Relación Normalizada Internacional/métodos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Tiempo de Protrombina/métodos , Tromboelastografía/métodos , Adulto Joven
19.
Free Radic Biol Med ; 41(5): 775-85, 2006 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-16895798

RESUMEN

Macrophage death is a hallmark of advanced atherosclerotic plaque, and oxidized low-density lipoprotein (OxLDL) found in these lesions is believed to contribute to macrophage injury. However, the underlying mechanisms of this phenomenon are only poorly understood. Here we show that in human monocyte-derived macrophages, OxLDL depleted intracellular glutathione (GSH) and inhibited glutathione reductase, resulting in a marked diminution of the glutathione/glutathione disulfide ratio. In the absence of OxLDL, an 80% depletion of intracellular GSH levels did not affect cell viability, but glutathione depletion dramatically increased OxLDL-induced cell death. Conversely, supplementation of intracellular GSH stores with glutathione diethyl ester substantially diminished OxLDL toxicity. OxLDL also promoted protein-S-glutathionylation, which was increased in macrophages pretreated with the glutathione reductase inhibitor BCNU. Knockdown experiments with siRNA directed against glutathione reductase and glutaredoxin showed that both enzymes are essential for the protection of macrophages against OxLDL. Finally, the peroxyl-radical scavenger Trolox did not prevent GSH depletion but completely blocked OxLDL-induced protein-S-glutathionylation and cell death. These data suggest that OxLDL promotes ROS formation and protein-S-glutathionylation by a mechanism independent from its effect on GSH depletion. Neither mechanism was sufficient to induce macrophage injury, but when stimulated concurrently, these pathways promoted the accumulation of protein-glutathione mixed disulfides and cell death.


Asunto(s)
Glutatión Reductasa/metabolismo , Glutatión/química , Lipoproteínas LDL/metabolismo , Macrófagos/metabolismo , Oxidorreductasas/química , Oxígeno/metabolismo , Muerte Celular , Glutarredoxinas , Glutatión/metabolismo , Humanos , Lipoproteínas/química , Macrófagos/patología , Modelos Biológicos , Modelos Químicos , Monocitos/metabolismo , ARN Interferente Pequeño/metabolismo , Especies Reactivas de Oxígeno
20.
Free Radic Biol Med ; 41(1): 165-74, 2006 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-16781464

RESUMEN

Impaired wound healing contributes to the morbidity and mortality associated with adriamycin chemotherapy. Macrophages are essential for tissue repair and loss of macrophage function leads to impaired wound healing. We recently showed that adriamycin is a potent inducer of thiol oxidation and cell injury in cultured macrophages (FASEB J. 19:1866-1868; 2005). Here we tested the hypothesis that adriamycin also promotes oxidative stress and macrophage dysfunction in vivo. We treated FVB mice twice a week either with low doses of adriamycin (4 mg/kg) or with the same volume of saline by tail vein injection for a total of 8 injections. Wound healing was significantly delayed in adriamycin-treated mice. The number of resident peritoneal macrophages was decreased by 30% and macrophage recruitment in response to thiogycolate stimulation was decreased by 46% in mice treated with adriamycin. LPS-induced TNFalpha and IL-1beta secretion from macrophages of adriamycin-treated mice was decreased by 28.7 and 29.5%, respectively, compared to macrophages isolated from saline-injected mice. Peritoneal macrophages isolated from adriamycin-treated mice also showed increased formation of reactive oxygen species and enhanced protein-S-glutathionylation. In summary, our results show that low cumulative doses of adriamycin are sufficient both to promote sustained thiol oxidative stress and macrophage dysfunction in vivo and to delay tissue repair, suggesting that macrophage dysfunction contributes to impaired wound healing associated with adriamycin chemotherapy.


Asunto(s)
Doxorrubicina/farmacología , Macrófagos/efectos de los fármacos , Animales , Recuento de Células Sanguíneas , Glutatión/metabolismo , Lipopolisacáridos/farmacología , Macrófagos/inmunología , Ratones , FN-kappa B/metabolismo , Estrés Oxidativo/fisiología , Especies Reactivas de Oxígeno/metabolismo , Cicatrización de Heridas/efectos de los fármacos , Cicatrización de Heridas/fisiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA