Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Bases de datos
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
Clin Chem ; 59(12): 1722-31, 2013 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-23938455

RESUMEN

BACKGROUND: Multiplex digital PCR (dPCR) enables noninvasive and sensitive detection of circulating tumor DNA with performance unachievable by current molecular-detection approaches. Furthermore, picodroplet dPCR facilitates simultaneous screening for multiple mutations from the same sample. METHODS: We investigated the utility of multiplex dPCR to screen for the 7 most common mutations in codons 12 and 13 of the KRAS (Kirsten rat sarcoma viral oncogene homolog) oncogene from plasma samples of patients with metastatic colorectal cancer. Fifty plasma samples were tested from patients for whom the primary tumor biopsy tissue DNA had been characterized by quantitative PCR. RESULTS: Tumor characterization revealed that 19 patient tumors had KRAS mutations. Multiplex dPCR analysis of the plasma DNA prepared from these samples identified 14 samples that matched the mutation identified in the tumor, 1 sample contained a different KRAS mutation, and 4 samples had no detectable mutation. Among the tumor samples that were wild type for KRAS, 2 KRAS mutations were identified in the corresponding plasma samples. Duplex dPCR (i.e., wild-type and single-mutation assay) was also used to analyze plasma samples from patients with KRAS-mutated tumors and 5 samples expected to contain the BRAF (v-raf murine sarcoma viral oncogene homolog B) V600E mutation. The results for the duplex analysis matched those for the multiplex analysis for KRAS-mutated samples and, owing to its higher sensitivity, enabled detection of 2 additional samples with low levels of KRAS-mutated DNA. All 5 samples with BRAF mutations were detected. CONCLUSIONS: This work demonstrates the clinical utility of multiplex dPCR to screen for multiple mutations simultaneously with a sensitivity sufficient to detect mutations in circulating DNA obtained by noninvasive blood collection.


Asunto(s)
Neoplasias Colorrectales/sangre , ADN/sangre , Genes ras , Mutación , Reacción en Cadena de la Polimerasa/métodos , Secuencia de Bases , Cartilla de ADN , Humanos , Límite de Detección
2.
Clin Chem ; 59(5): 815-23, 2013 May.
Artículo en Inglés | MEDLINE | ID: mdl-23403697

RESUMEN

BACKGROUND: Assessment of DNA integrity and quantity remains a bottleneck for high-throughput molecular genotyping technologies, including next-generation sequencing. In particular, DNA extracted from paraffin-embedded tissues, a major potential source of tumor DNA, varies widely in quality, leading to unpredictable sequencing data. We describe a picoliter droplet-based digital PCR method that enables simultaneous detection of DNA integrity and the quantity of amplifiable DNA. METHODS: Using a multiplex assay, we detected 4 different target lengths (78, 159, 197, and 550 bp). Assays were validated with human genomic DNA fragmented to sizes of 170 bp to 3000 bp. The technique was validated with DNA quantities as low as 1 ng. We evaluated 12 DNA samples extracted from paraffin-embedded lung adenocarcinoma tissues. RESULTS: One sample contained no amplifiable DNA. The fractions of amplifiable DNA for the 11 other samples were between 0.05% and 10.1% for 78-bp fragments and ≤1% for longer fragments. Four samples were chosen for enrichment and next-generation sequencing. The quality of the sequencing data was in agreement with the results of the DNA-integrity test. Specifically, DNA with low integrity yielded sequencing results with lower levels of coverage and uniformity and had higher levels of false-positive variants. CONCLUSIONS: The development of DNA-quality assays will enable researchers to downselect samples or process more DNA to achieve reliable genome sequencing with the highest possible efficiency of cost and effort, as well as minimize the waste of precious samples.


Asunto(s)
Fragmentación del ADN , ADN de Neoplasias/análisis , Secuenciación de Nucleótidos de Alto Rendimiento/métodos , Reacción en Cadena de la Polimerasa Multiplex/métodos , Análisis de Secuencia de ADN/métodos , Genoma Humano , Humanos , Neoplasias Pulmonares/química , Reproducibilidad de los Resultados
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA