Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros

Bases de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
JACC Cardiovasc Interv ; 17(17): 2054-2066, 2024 Sep 09.
Artículo en Inglés | MEDLINE | ID: mdl-39260962

RESUMEN

BACKGROUND: Fluid overload (FO) subjects patients with severe aortic stenosis (AS) to increased risk for heart failure and death after valve replacement and can be objectively quantified using bioimpedance spectroscopy (BIS). OBJECTIVES: The authors hypothesized that in AS patients with concomitant FO, BIS-guided decongestion could improve prognosis and quality of life following transcatheter aortic valve replacement (TAVR). METHODS: This randomized, controlled trial enrolled 232 patients with severe AS scheduled for TAVR. FO was defined using a portable whole-body BIS device according to previously established cutoffs (≥1.0 L and/or ≥7%). Patients with FO (n = 111) were randomly assigned 1:1 to receive BIS-guided decongestion (n = 55) or decongestion by clinical judgment alone (n = 56) following TAVR. Patients without FO (n = 121) served as a control cohort. The primary endpoint was the composite of hospitalization for heart failure and/or all-cause death at 12 months. The secondary endpoint was the change from baseline to 12 months in the Kansas City Cardiomyopathy Questionnaire. RESULTS: The occurrence of the primary endpoint at 12 months was significantly lower in the BIS-guided vs the non-BIS-guided decongestion group (7/55 [12.7%, all deaths] vs 18/56 [32.1%, 9 hospitalizations for heart failure and 9 deaths]; HR: 0.36; 95% CI: 0.15-0.87; absolute risk reduction = -19.4%). Outcomes in the BIS-guided decongestion group were identical to the euvolemic control group (log-rank test, P = 0.7). BIS-guided decongestion was also associated with a higher increase in the Kansas City Cardiomyopathy Questionnaire score from baseline compared to non-BIS-guided decongestion (P = 0.001). CONCLUSIONS: In patients with severe AS and concomitant FO, quantitatively guided decongestive treatment and associated intensified management post-TAVR was associated with improved outcomes and quality of life compared to decongestion by clinical judgment alone. (Management of Fluid Overload in Patients Scheduled for Transcatheter Aortic Valve Replacement [EASE-TAVR]; NCT04556123).


Asunto(s)
Estenosis de la Válvula Aórtica , Insuficiencia Cardíaca , Calidad de Vida , Índice de Severidad de la Enfermedad , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Estenosis de la Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/mortalidad , Femenino , Masculino , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Resultado del Tratamiento , Anciano , Anciano de 80 o más Años , Factores de Riesgo , Factores de Tiempo , Insuficiencia Cardíaca/fisiopatología , Insuficiencia Cardíaca/mortalidad , Insuficiencia Cardíaca/terapia , Insuficiencia Cardíaca/diagnóstico , Espectroscopía Dieléctrica , Desequilibrio Hidroelectrolítico/fisiopatología , Desequilibrio Hidroelectrolítico/terapia , Desequilibrio Hidroelectrolítico/diagnóstico , Desequilibrio Hidroelectrolítico/mortalidad , Desequilibrio Hidroelectrolítico/etiología , Válvula Aórtica/cirugía , Válvula Aórtica/fisiopatología , Válvula Aórtica/diagnóstico por imagen , Valor Predictivo de las Pruebas , Recuperación de la Función , Estudios Prospectivos
2.
Eur J Heart Fail ; 25(10): 1808-1818, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37462329

RESUMEN

AIMS: Cardiac decompensation in aortic stenosis (AS) involves extra-valvular cardiac damage and progressive fluid overload (FO). FO can be objectively quantified using bioimpedance spectroscopy. We aimed to assess the prognostic value of FO beyond established damage markers to guide risk stratification. METHODS AND RESULTS: Consecutive patients with severe AS scheduled for transcatheter aortic valve implantation (TAVI) underwent prospective risk assessment with bioimpedance spectroscopy (BIS) and echocardiography. FO by BIS was defined as ≥1.0 L (0.0 L = euvolaemia). The extent of cardiac damage was assessed by echocardiography according to an established staging classification. Right-sided cardiac damage (rCD) was defined as pulmonary vasculature/tricuspid/right ventricular damage. Hospitalization for heart failure (HHF) and/or death served as primary endpoint. In total, 880 patients (81 ± 7 years, 47% female) undergoing TAVI were included and 360 (41%) had FO. Clinical examination in patients with FO was unremarkable for congestion signs in >50%. A quarter had FO but no rCD (FO+/rCD-). FO+/rCD+ had the highest damage markers, including N-terminal pro-B-type natriuretic peptide (NT-proBNP) levels. After 2.4 ± 1.0 years of follow-up, 236 patients (27%) had reached the primary endpoint (29 HHF, 194 deaths, 13 both). Quantitatively, every 1.0 L increase in bioimpedance was associated with a 13% increase in event hazard (adjusted hazard ratio 1.13, 95% confidence interval 1.06-1.22, p < 0.001). FO provided incremental prognostic value to traditional risk markers (NT-proBNP, EuroSCORE II, damage on echocardiography). Stratification according to FO and rCD yielded worse outcomes for FO+/rCD+ and FO+/rCD-, but not FO-/rCD+, compared to FO-/rCD-. CONCLUSION: Quantitative FO in patients with severe AS improves risk prediction of worse post-interventional outcomes compared to traditional risk assessment.


Asunto(s)
Estenosis de la Válvula Aórtica , Insuficiencia Cardíaca , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Femenino , Masculino , Insuficiencia Cardíaca/etiología , Estudios Prospectivos , Pronóstico , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/cirugía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA