Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
J Nucl Cardiol ; 25(4): 1101-1109, 2018 08.
Artículo en Inglés | MEDLINE | ID: mdl-28028761

RESUMEN

BACKGROUND: A possible relationship between cardiac sympathetic denervation and left ventricular (LV) diastolic dysfunction has been suggested. However, an evaluation of the interactions between myocardial adrenergic tone and LV perfusion and diastolic function is lacking. METHODS AND RESULTS: Seventy-two patients underwent 99mTc-tetrofosmin/123I-metaiodobenzylguanidine (123I-MIBG) cardiac Cadmium-Zinc-Telluride (CZT) imaging. The summed rest score (SRS) and summed 123I-MIBG score (SS-MIBG) were computed as measures of regional perfusion and innervation heterogeneities. LV segments showing an impaired innervation, despite a relatively preserved perfusion (99mTc-tetrofosmin-123I-MIBG tracers' uptake ≥25%), were individuated (innervation/perfusion mismatch). The peak filling rate (PFR) was computed as a measure of LV diastolic function. Nineteen of the 72 (26%) patients presented a normal LV diastolic function, while 29 (40%) and 24 (34%) had a mild and overt diastolic dysfunction. Subjects with diastolic dysfunction showed more abnormal SRS and SS-MIBG values (P < 0.001). In the global population, 502/1224 (41%) LV segments showed an innervation/perfusion mismatch. A modest correlation between the extent of cardiac innervation/perfusion mismatch and PFR values was evident (R = -0.27, P = 0.029). On multivariate analysis, the extent of regional innervation/perfusion mismatch remained an independent predictor of overt LV diastolic abnormalities (P = 0.017). CONCLUSIONS: The burden of LV regions showing an innervation/perfusion mismatch associates with the occurrence of overt diastolic dysfunction.


Asunto(s)
Diástole/fisiología , Ventrículos Cardíacos/inervación , Imagen de Perfusión Miocárdica , Sistema Nervioso Simpático/fisiología , Disfunción Ventricular Izquierda/etiología , 3-Yodobencilguanidina , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Función Ventricular Izquierda
2.
Pediatr Radiol ; 48(10): 1417-1422, 2018 09.
Artículo en Inglés | MEDLINE | ID: mdl-29855677

RESUMEN

BACKGROUND: Few studies, and with conflicting results, have evaluated the potential effects of iodinated contrast media on children's thyroid function. OBJECTIVE: To investigate the effects of iodinated contrast medium on thyroid function in neonates, infants and young children with congenital heart disease undergoing cardiac computed tomography (CT). MATERIALS AND METHODS: We retrospectively evaluated 10 neonates (group 1) and 23 infants and young children (group 2) without thyroid or renal disease for serum levels of thyroid-stimulating hormone, free triiodothyronine and free thyroxine before contrast-enhanced cardiac CT, 48 h after CT and at discharge from the hospital. Cardiac CT was performed with intravenous administration of 1.14±0.17 mL/kg of body weight of iopromide (containing 370 mg of iodine/mL). RESULTS: Group 1 had a reduction of thyroid-stimulating hormone from baseline to 48 h post injection (P=0.002). Group 2 had a reduction of thyroid-stimulating hormone median levels from baseline to 48 h post injection and an increase from 48 h to discharge (P=0.0005 and P=0.0001, respectively). CONCLUSION: Intravenous iodinated contrast medium in children with congenital heart disease caused transient thyroid-stimulating hormone decrease 48 h after CT, with thyroid-stimulating hormone returning to normal range at discharge.


Asunto(s)
Medios de Contraste/administración & dosificación , Cardiopatías Congénitas/diagnóstico por imagen , Yohexol/análogos & derivados , Glándula Tiroides/efectos de los fármacos , Tomografía Computarizada por Rayos X , Preescolar , Femenino , Humanos , Lactante , Recién Nacido , Yohexol/administración & dosificación , Masculino , Estudios Retrospectivos , Pruebas de Función de la Tiroides
3.
Eur Heart J Cardiovasc Imaging ; 16(11): 1276-87, 2015 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-25916628

RESUMEN

AIMS: Percutaneous left atrial appendage occlusion (LAAO) with the Amplatzer Cardiac Plug (ACP) emerged as a valid alternative in patients with a formal contraindication to oral anticoagulant therapy. Transoesophageal echocardiography (TEE), cardiac computed tomography angiography (CCTA), intracardiac echocardiography (ICE), and conventional cardiac angiography (CCA) are used to evaluate LAA diameters. The aim of our study was to compare pre- and intraprocedural imaging techniques in determining the correct selection of the device size, with a retrospective evaluation of the results obtained at post-procedural CCTA follow-up. METHODS AND RESULTS: Between September 2009 and July 2013, 66 consecutive patients underwent to LAAO with the ACP at our institution. Preoperative LAA evaluation was realized with TEE, CCTA, ICE, and CCA. Fifty-eight (58) patients underwent to post-procedural CCTA to confirm the LAA complete exclusion, the number and extent of the residual leaks, and the positioning of the device. LAA diameters measured by CCTA correlate with the diameters obtained with CCA and ICE, but they are sized slightly larger than the others. TEE has a lower correlation with every other imaging method and a likely tendency to underestimate. The distribution of the leaks and the positioning of the device in post-procedural CCTA show no substantial differences between the devices used greater or equal to the one selected with CCTA in terms of LAA exclusion. CONCLUSION: The sizing of the device decided using CCTA in the phase of maximum LAA expansion reduces the risk of high-flow leaks and device malposition due to undersizing.


Asunto(s)
Apéndice Atrial/cirugía , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Imagen Multimodal , Dispositivo Oclusor Septal , Anciano , Cateterismo Cardíaco/métodos , Angiografía Coronaria , Ecocardiografía Transesofágica , Femenino , Humanos , Masculino , Cuidados Preoperatorios , Estudios Retrospectivos , Tomografía Computarizada por Rayos X , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA