Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Bases de datos
Tipo del documento
Intervalo de año de publicación
1.
J Orthop Surg Res ; 18(1): 976, 2023 Dec 19.
Artículo en Inglés | MEDLINE | ID: mdl-38115076

RESUMEN

BACKGROUND: The rolling contact joint (RCJ) mechanism is a system of constraint that allows two circular bodies connected with flexible straps to roll relative to one another without slipping. This study aims to compare the biomechanical characteristics between the conventional proximal interphalangeal joint (PIPJ) flexible hinge (FH) implant and the novel PIPJ implant adopting a RCJ mechanism during PIPJ range of motion using finite element (FE) analysis. METHODS: The three-dimensional (3D) surface shape of a conventional PIPJ FH implant was obtained using a 3D laser surface scanning system. The configuration and parameters of the novel PIPJ implant were adapted from a previous study. The two implants were assumed to have the same material characteristics and each implant was composed of a hyperelastic material, silicone elastomers. The configuration data for both implants were imported to a computer-aided design program to generate 3D geometrical surface and hyperelastic models of both implants. The hyperelastic models of both implants were imported into a structural engineering software to produce the FE mesh and to perform FE analysis. The FE analysis modeled the changes of mechanics during flexion-extension motion between 0° and 90° of two PIPJ implants. The mean and maximum values of von-Mises stress and strain as well as the total moment reaction based on the range of motion of the PIPJs were calculated. The mean values within the PIPJ's functional range of motion of the mean and maxinum von-Mises stress and strain and the total moment reaction were also determined. RESULTS: The maximum values for the von-Mises stress, and strain, as well as the total moment reactions of the conventional PIPJ FH and novel PIPJ implants were all at 90° of PIPJ flexion. The maximum value of each biomechanical property for the novel PIPJ implant was considerably lower compared with that of the conventional PIPJ FH implant. The mean values within the PIPJ's functional range of motion of the maximum von-Mises stress and strain for the novel PIPJ implant was approximately 6.43- and 6.46-fold lower compared with that of the conventional PIPJ FH implant, respectively. The mean value within a PIPJ's functional range of motion of the total moment reaction of the novel PIPJ implant was approximately 49.6-fold lower compared with that of the conventional PIPJ FH implant. CONCLUSIONS: The novel PIPJ implant with an RCJ mechanism may offer improved biomechanical performance compared with conventional PIPJ FH implant.


Asunto(s)
Articulaciones , Prótesis e Implantes , Análisis de Elementos Finitos , Estrés Mecánico , Programas Informáticos , Fenómenos Biomecánicos
2.
Food Chem ; 110(4): 979-84, 2008 Oct 15.
Artículo en Inglés | MEDLINE | ID: mdl-26047289

RESUMEN

A gene encoding a putative glycogen branching enzyme (SmGBE) in Streptococcus mutans was expressed in Escherichia coli and purified. The biochemical properties of the purified enzyme were examined relative to its branching specificity for amylose and starch. The activity of the approximately 75kDa enzyme was optimal at pH 5.0, and stable up to 40°C. The enzyme predominantly transferred short maltooligosyl chains with a degree of polymerization (dp) of 6 and 7 throughout the branching process for amylose. When incubated with rice starch, the enzyme modified its optimal branch chain-length from dp 12 to 6 with large reductions in the longer chains, and simultaneously increased its branching points. The results indicate that SmGBE can make a modified starch with much shorter branches and a more branched structure than to native starch. In addition, starch retrogradation due to low temperature storage was significantly retarded along with the enzyme reaction.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA