Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 23
Filtrar
Más filtros

Bases de datos
Tipo del documento
Intervalo de año de publicación
1.
Nat Methods ; 13(2): 151-7, 2016 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-26689262

RESUMEN

Here we describe the development of a human lung 'small airway-on-a-chip' containing a differentiated, mucociliary bronchiolar epithelium and an underlying microvascular endothelium that experiences fluid flow, which allows for analysis of organ-level lung pathophysiology in vitro. Exposure of the epithelium to interleukin-13 (IL-13) reconstituted the goblet cell hyperplasia, cytokine hypersecretion and decreased ciliary function of asthmatics. Small airway chips lined with epithelial cells from individuals with chronic obstructive pulmonary disease recapitulated features of the disease such as selective cytokine hypersecretion, increased neutrophil recruitment and clinical exacerbation by exposure to viral and bacterial infections. With this robust in vitro method for modeling human lung inflammatory disorders, it is possible to detect synergistic effects of lung endothelium and epithelium on cytokine secretion, identify new biomarkers of disease exacerbation and measure responses to anti-inflammatory compounds that inhibit cytokine-induced recruitment of circulating neutrophils under flow.


Asunto(s)
Epitelio/efectos de los fármacos , Inflamación/metabolismo , Interleucina-13/farmacología , Dispositivos Laboratorio en un Chip , Enfermedades Pulmonares/tratamiento farmacológico , Enfermedades Pulmonares/metabolismo , Humanos , Inflamación/patología , Técnicas de Cultivo de Tejidos
2.
Toxicol Sci ; 195(1): 61-70, 2023 08 29.
Artículo en Inglés | MEDLINE | ID: mdl-37462734

RESUMEN

Cardiovascular toxicity is an important cause of drug failures in the later stages of drug development, early clinical safety assessment, and even postmarket withdrawals. Early-stage in vitro assessment of potential cardiovascular liabilities in the pharmaceutical industry involves assessment of interactions with cardiac ion channels, as well as induced pluripotent stem cell-derived cardiomyocyte-based functional assays, such as calcium flux and multielectrode-array assays. These methods are appropriate for the identification of acute functional cardiotoxicity but structural cardiotoxicity, which manifests effects after chronic exposure, is often only captured in vivo. CardioMotion is a novel, label-free, high throughput, in vitro assay and analysis pipeline which records and assesses the spontaneous beating of cardiomyocytes and identifies compounds which impact beating. This is achieved through the acquisition of brightfield images at a high framerate, combined with an optical flow-based python analysis pipeline which transforms the images into waveform data which are then parameterized. Validation of this assay with a large dataset showed that cardioactive compounds with diverse known direct functional and structural mechanisms-of-action on cardiomyocytes are identified (sensitivity = 72.9%), importantly, known structural cardiotoxins also disrupt cardiomyocyte beating (sensitivity = 86%) in this method. Furthermore, the CardioMotion method presents a high specificity of 82.5%.


Asunto(s)
Cardiotoxicidad , Células Madre Pluripotentes Inducidas , Humanos , Cardiotoxicidad/etiología , Células Cultivadas , Miocitos Cardíacos
3.
Clin Transl Sci ; 15(8): 1978-1989, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-35579204

RESUMEN

Lamotrigine, approved for use as an antiseizure medication as well as the treatment of bipolar disorder, inhibits sodium channels in the brain to reduce repetitive neuronal firing and pathological release of glutamate. The shared homology of sodium channels and lack of selectivity associated with channel blocking agents can cause slowing of cardiac conduction and increased proarrhythmic potential. The Vaughan-Williams classification system differentiates sodium channel blockers using biophysical properties of binding. As such, Class Ib inhibitors, including mexiletine, do not slow cardiac conduction as measured by the electrocardiogram, at therapeutically relevant exposure. Our goal was to characterize the biophysical properties of NaV 1.5 block and to support the observed clinical safety of lamotrigine. We used HEK-293 cells stably expressing the hNaV 1.5 channel and voltage clamp electrophysiology to quantify the potency (half-maximal inhibitory concentration) against peak and late channel current, on-/off-rate binding kinetics, voltage-dependence, and tonic block of the cardiac sodium channel by lamotrigine; and compared to clinically relevant Class Ia (quinidine), Ib (mexiletine), and Ic (flecainide) inhibitors. Lamotrigine blocked peak and late NaV 1.5 current at therapeutically relevant exposure, with rapid kinetics and biophysical properties similar to the class Ib inhibitor mexiletine. However, no clinically meaningful prolongation in QRS or PR interval was observed in healthy subjects in a new analysis of a previously reported thorough QT clinical trial (SCA104648). In conclusion, the weak NaV 1.5 block and rapid kinetics do not translate into clinically relevant conduction slowing at therapeutic exposure and support the clinical safety of lamotrigine in patients suffering from epilepsy and bipolar disorder.


Asunto(s)
Mexiletine , Canales de Sodio , Anticonvulsivantes/farmacología , Flecainida/farmacología , Células HEK293 , Humanos , Lamotrigina/farmacología , Mexiletine/farmacología , Bloqueadores de los Canales de Sodio/farmacología , Canales de Sodio/metabolismo
4.
Circ Res ; 104(1): 95-103, 2009 Jan 02.
Artículo en Inglés | MEDLINE | ID: mdl-19023131

RESUMEN

Previous studies demonstrated increased fatty acid uptake and metabolism in MHC-FATP transgenic mice that overexpress fatty acid transport protein (FATP)1 in the heart under the control of the alpha-myosin heavy chain (alpha-MHC) promoter. Doppler tissue imaging and hemodynamic measurements revealed diastolic dysfunction, in the absence of changes in systolic function. The experiments here directly test the hypothesis that the diastolic dysfunction in MHC-FATP mice reflects impaired ventricular myocyte contractile function. In vitro imaging of isolated adult MHC-FATP ventricular myocytes revealed that mean diastolic sarcomere length is significantly (P<0.01) shorter than in wild-type (WT) cells (1.79+/-0.01 versus 1.84+/-0.01 microm). In addition, the relaxation rate (dL/dt) is significantly (P<0.05) slower in MHC-FATP than WT myocytes (1.58+/-0.09 versus 1.92+/-0.13 microm/s), whereas both fractional shortening and contraction rates are not different. Application of 40 mmol/L 2,3-butadionemonoxime (a nonspecific ATPase inhibitor that relaxes actin-myosin interactions) increased diastolic sarcomere length in both WT and MHC-FATP myocytes to the same length, suggesting that MHC-FATP myocytes are partially activated at rest. Direct measurements of intracellular Ca(2+) revealed that diastolic [Ca(2+)](i) is unchanged in MHC-FATP myocytes and the rate of calcium removal is unexpectedly faster in MHC-FATP than WT myocytes. Moreover, diastolic sarcomere length in MHC-FATP and WT myocytes was unaffected by removal of extracellular Ca(2+) or by buffering of intracellular Ca(2+) with the Ca(2+) chelator BAPTA (100 micromol/L), indicating that elevated intracellular Ca(2+) does not underlie impaired diastolic function in MHC-FATP ventricular myocytes. Functional assessment of skinned myocytes, however, revealed that myofilament Ca(2+) sensitivity is markedly increased in MHC-FATP, compared with WT, ventricular cells. In addition, biochemical experiments demonstrated increased expression of the beta-MHC isoform in MHC-FATP, compared with WT ventricles, which likely contributes to the slower relaxation rate observed in MHC-FATP myocytes. Collectively, these data demonstrate that derangements in lipid metabolism in MHC-FATP ventricles, which are similar to those observed in the diabetic heart, result in impaired diastolic function that primarily reflects changes in myofilament function, rather than altered Ca(2+) cycling.


Asunto(s)
Complicaciones de la Diabetes/fisiopatología , Proteínas de Transporte de Ácidos Grasos/fisiología , Ácidos Grasos/metabolismo , Insuficiencia Cardíaca Diastólica/fisiopatología , Miocitos Cardíacos/fisiología , Sarcómeros/ultraestructura , Animales , Calcio/fisiología , Quelantes/farmacología , Complicaciones de la Diabetes/patología , Diacetil/análogos & derivados , Diacetil/farmacología , Diástole , Modelos Animales de Enfermedad , Ácido Egtácico/análogos & derivados , Ácido Egtácico/farmacología , Proteínas de Transporte de Ácidos Grasos/genética , Insuficiencia Cardíaca Diastólica/patología , Ventrículos Cardíacos/patología , Contracción Isométrica , Ratones , Ratones Transgénicos , Contracción Miocárdica , Miocardio/metabolismo , Miocitos Cardíacos/efectos de los fármacos , Miocitos Cardíacos/ultraestructura , Cadenas Pesadas de Miosina/biosíntesis , Cadenas Pesadas de Miosina/genética , Proteínas Recombinantes de Fusión/fisiología , Sarcómeros/efectos de los fármacos
5.
Bioorg Med Chem Lett ; 21(9): 2626-30, 2011 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-21315584

RESUMEN

We describe the systematic optimization, focused on the improvement of CV-TI, of a series of CCR2 antagonists. This work resulted in the identification of 10 (((1S,3R)-1-isopropyl-3-((3S,4S)-3-methoxy-tetrahydro-2H-pyran-4-ylamino)cyclopentyl)(4-(5-(trifluoromethyl)pyridazin-3-yl)piperazin-1-yl)methanone) which possessed a low projected human dose 35-45mg BID and a CV-TI=3800-fold.


Asunto(s)
Antiinflamatorios/farmacología , Modelos Moleculares , Piperazinas/química , Piperazinas/farmacología , Piridazinas/química , Piridazinas/farmacología , Receptores CCR2/agonistas , Antiinflamatorios/química , Antiinflamatorios/farmacocinética , Bioensayo , Humanos , Concentración 50 Inhibidora , Microsomas/efectos de los fármacos , Microsomas/metabolismo , Estructura Molecular , Piperazinas/farmacocinética , Unión Proteica/efectos de los fármacos , Piridazinas/farmacocinética , Receptores CCR2/sangre , Relación Estructura-Actividad
6.
Clin Pharmacol Ther ; 109(2): 310-318, 2021 02.
Artículo en Inglés | MEDLINE | ID: mdl-32866317

RESUMEN

Defining an appropriate and efficient assessment of drug-induced corrected QT interval (QTc) prolongation (a surrogate marker of torsades de pointes arrhythmia) remains a concern of drug developers and regulators worldwide. In use for over 15 years, the nonclinical International Council for Harmonization of Technical Requirements for Pharmaceuticals for Human Use (ICH) S7B and clinical ICH E14 guidances describe three core assays (S7B: in vitro hERG current & in vivo QTc studies; E14: thorough QT study) that are used to assess the potential of drugs to cause delayed ventricular repolarization. Incorporating these assays during nonclinical or human testing of novel compounds has led to a low prevalence of QTc-prolonging drugs in clinical trials and no new drugs having been removed from the marketplace due to unexpected QTc prolongation. Despite this success, nonclinical evaluations of delayed repolarization still minimally influence ICH E14-based strategies for assessing clinical QTc prolongation and defining proarrhythmic risk. In particular, the value of ICH S7B-based "double-negative" nonclinical findings (low risk for hERG block and in vivo QTc prolongation at relevant clinical exposures) is underappreciated. These nonclinical data have additional value in assessing the risk of clinical QTc prolongation when clinical evaluations are limited by heart rate changes, low drug exposures, or high-dose safety considerations. The time has come to meaningfully merge nonclinical and clinical data to enable a more comprehensive, but flexible, clinical risk assessment strategy for QTc monitoring discussed in updated ICH E14 Questions and Answers. Implementing a fully integrated nonclinical/clinical risk assessment for compounds with double-negative nonclinical findings in the context of a low prevalence of clinical QTc prolongation would relieve the burden of unnecessary clinical QTc studies and streamline drug development.


Asunto(s)
Drogas en Investigación/efectos adversos , Síndrome de QT Prolongado/inducido químicamente , Animales , Arritmias Cardíacas/inducido químicamente , Desarrollo de Medicamentos/métodos , Industria Farmacéutica/métodos , Electrocardiografía/métodos , Humanos , Medición de Riesgo , Torsades de Pointes/inducido químicamente
7.
J Mol Cell Cardiol ; 48(2): 395-405, 2010 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-19857498

RESUMEN

There is considerable evidence to support a role for lipotoxicity in the development of diabetic cardiomyopathy, although the molecular links between enhanced saturated fatty acid uptake/metabolism and impaired cardiac function are poorly understood. In the present study, the effects of acute exposure to the saturated fatty acid, palmitate, on myocardial contractility and excitability were examined directly. Exposure of isolated (adult mouse) ventricular myocytes to palmitate, complexed to bovine serum albumin (palmitate:BSA) as in blood, rapidly reduced (by 54+/-4%) mean (+/-SEM) unloaded fractional cell shortening. The amplitudes of intracellular Ca(2+) transients decreased in parallel. Current-clamp recordings revealed that exposure to palmitate:BSA markedly shortened action potential durations at 20%, 50%, and 90% repolarization. These effects were reversible and were occluded when the K(+) in the recording pipettes was replaced with Cs(+), suggesting a direct effect on repolarizing K(+) currents. Indeed, voltage-clamp recordings revealed that palmitate:BSA reversibly and selectively increased peak outward voltage-gated K(+) (Kv) current amplitudes by 20+/-2%, whereas inwardly rectifying K(+) (Kir) currents and voltage-gated Ca(2+) currents were unaffected. Further analyses revealed that the individual Kv current components I(to,f), I(K,slow) and I(ss), were all increased (by 12+/-2%, 37+/-4%, and 34+/-4%, respectively) in cells exposed to palmitate:BSA. Consistent with effects on both components of I(K,slow) (I(K,slow1) and I(K,slow)(2)) the magnitude of the palmitate-induced increase was attenuated in ventricular myocytes isolated from animals in which the Kv1.5 (I(K,slow)(1)) or the Kv2.1 (I(K,slow)(2)) locus was disrupted and I(K,slow)(1) or I(K,slow2) is eliminated. Both the enhancement of I(K,slow) and the negative inotropic effect of palmitate:BSA were reduced in the presence of the Kv1.5 selective channel blocker, diphenyl phosphine oxide-1 (DPO-1).Taken together, these results suggest that elevations in circulating saturated free fatty acids, as occurs in diabetes, can directly augment repolarizing myocardial Kv currents and impair excitation-contraction coupling.


Asunto(s)
Activación del Canal Iónico/efectos de los fármacos , Contracción Miocárdica/efectos de los fármacos , Palmitatos/farmacología , Canales de Potasio/metabolismo , Potenciales de Acción/efectos de los fármacos , Animales , Señalización del Calcio/efectos de los fármacos , Bovinos , Ventrículos Cardíacos/citología , Espacio Intracelular/efectos de los fármacos , Espacio Intracelular/metabolismo , Canal de Potasio Kv1.5/metabolismo , Ratones , Ratones Endogámicos C57BL , Miocitos Cardíacos/efectos de los fármacos , Miocitos Cardíacos/metabolismo , Fosfinas/farmacología , Bloqueadores de los Canales de Potasio/farmacología , Sarcolema/efectos de los fármacos , Sarcolema/metabolismo , Albúmina Sérica Bovina/farmacología , Canales de Potasio Shab/metabolismo
8.
Toxicol Sci ; 176(1): 103-123, 2020 07 01.
Artículo en Inglés | MEDLINE | ID: mdl-32421822

RESUMEN

Animal models are 78% accurate in determining whether drugs will alter contractility of the human heart. To evaluate the suitability of human-induced pluripotent stem cell-derived cardiomyocytes (hiPSC-CMs) for predictive safety pharmacology, we quantified changes in contractility, voltage, and/or Ca2+ handling in 2D monolayers or 3D engineered heart tissues (EHTs). Protocols were unified via a drug training set, allowing subsequent blinded multicenter evaluation of drugs with known positive, negative, or neutral inotropic effects. Accuracy ranged from 44% to 85% across the platform-cell configurations, indicating the need to refine test conditions. This was achieved by adopting approaches to reduce signal-to-noise ratio, reduce spontaneous beat rate to ≤ 1 Hz or enable chronic testing, improving accuracy to 85% for monolayers and 93% for EHTs. Contraction amplitude was a good predictor of negative inotropes across all the platform-cell configurations and of positive inotropes in the 3D EHTs. Although contraction- and relaxation-time provided confirmatory readouts forpositive inotropes in 3D EHTs, these parameters typically served as the primary source of predictivity in 2D. The reliance of these "secondary" parameters to inotropy in the 2D systems was not automatically intuitive and may be a quirk of hiPSC-CMs, hence require adaptations in interpreting the data from this model system. Of the platform-cell configurations, responses in EHTs aligned most closely to the free therapeutic plasma concentration. This study adds to the notion that hiPSC-CMs could add value to drug safety evaluation.


Asunto(s)
Relación Dosis-Respuesta a Droga , Células Madre Pluripotentes Inducidas , Miocitos Cardíacos , Preparaciones Farmacéuticas , Animales , Humanos
9.
Nat Biomed Eng ; 4(4): 407-420, 2020 04.
Artículo en Inglés | MEDLINE | ID: mdl-31988458

RESUMEN

Organ chips can recapitulate organ-level (patho)physiology, yet pharmacokinetic and pharmacodynamic analyses require multi-organ systems linked by vascular perfusion. Here, we describe an 'interrogator' that employs liquid-handling robotics, custom software and an integrated mobile microscope for the automated culture, perfusion, medium addition, fluidic linking, sample collection and in situ microscopy imaging of up to ten organ chips inside a standard tissue-culture incubator. The robotic interrogator maintained the viability and organ-specific functions of eight vascularized, two-channel organ chips (intestine, liver, kidney, heart, lung, skin, blood-brain barrier and brain) for 3 weeks in culture when intermittently fluidically coupled via a common blood substitute through their reservoirs of medium and endothelium-lined vascular channels. We used the robotic interrogator and a physiological multicompartmental reduced-order model of the experimental system to quantitatively predict the distribution of an inulin tracer perfused through the multi-organ human-body-on-chips. The automated culture system enables the imaging of cells in the organ chips and the repeated sampling of both the vascular and interstitial compartments without compromising fluidic coupling.


Asunto(s)
Técnicas de Cultivo de Célula/métodos , Dispositivos Laboratorio en un Chip , Microfluídica/métodos , Robótica/métodos , Barrera Hematoencefálica , Encéfalo , Calibración , Técnicas de Cultivo de Célula/instrumentación , Diseño de Equipo , Corazón , Humanos , Intestinos , Riñón , Hígado , Pulmón , Robótica/instrumentación , Piel
10.
PLoS One ; 12(2): e0169412, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28146569

RESUMEN

Analysis of enterovirus infection is difficult in animals because they express different virus receptors than humans, and static cell culture systems do not reproduce the physical complexity of the human intestinal epithelium. Here, using coxsackievirus B1 (CVB1) as a prototype enterovirus strain, we demonstrate that human enterovirus infection, replication and infectious virus production can be analyzed in vitro in a human Gut-on-a-Chip microfluidic device that supports culture of highly differentiated human villus intestinal epithelium under conditions of fluid flow and peristalsis-like motions. When CVB1 was introduced into the epithelium-lined intestinal lumen of the device, virions entered the epithelium, replicated inside the cells producing detectable cytopathic effects (CPEs), and both infectious virions and inflammatory cytokines were released in a polarized manner from the cell apex, as they could be detected in the effluent from the epithelial microchannel. When the virus was introduced via a basal route of infection (by inoculating virus into fluid flowing through a parallel lower 'vascular' channel separated from the epithelial channel by a porous membrane), significantly lower viral titers, decreased CPEs, and delayed caspase-3 activation were observed; however, cytokines continued to be secreted apically. The presence of continuous fluid flow through the epithelial lumen also resulted in production of a gradient of CPEs consistent with the flow direction. Thus, the human Gut-on-a-Chip may provide a suitable in vitro model for enteric virus infection and for investigating mechanisms of enterovirus pathogenesis.


Asunto(s)
Enterovirus Humano B/fisiología , Mucosa Intestinal/virología , Dispositivos Laboratorio en un Chip , Apoptosis , Células CACO-2 , Caspasas/metabolismo , Células Cultivadas , Infecciones por Coxsackievirus/metabolismo , Infecciones por Coxsackievirus/virología , Citocinas/metabolismo , Efecto Citopatogénico Viral , Humanos , Ensayo de Placa Viral , Replicación Viral
11.
ALTEX ; 34(4): 479-500, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28539002

RESUMEN

Amid growing efforts to advance the replacement, reduction, and refinement of the use of animals in research, there is a growing recognition that in vitro testing of medical devices can be more effective, both in terms of cost and time, and also more reliable than in vivo testing. Although the technological landscape has evolved rapidly in support of these concepts, regulatory acceptance of alternative testing methods has not kept pace. Despite the acceptance by regulators of some in vitro tests (cytotoxicity, gene toxicity, and some hemocompatibility assays), many toxicity tests still rely on animals (irritation, sensitization, acute toxicity, reproductive/developmental toxicity), even where other industrial sectors have already abandoned them. Bringing about change will require a paradigm shift in current approaches to testing - and a concerted effort to generate better data on risks to human health from exposure to leachable chemicals from medical devices, and to boost confidence in the use of alternative methods to test devices. To help advance these ideas, stir debate about best practices, and coalesce around a roadmap forward, the JHU-Center for Alternatives to Animal Testing (CAAT) hosted a symposium believed to be the first gathering dedicated to the topic of in vitro testing of medical devices. Industry representatives, academics, and regulators in attendance presented evidence to support the unique strengths and challenges associated with the approaches currently in use as well as new methods under development, and drew next steps to push the field forward from their presentations and discussion.


Asunto(s)
Alternativas a las Pruebas en Animales/tendencias , Equipos y Suministros/normas , Técnicas In Vitro , Pruebas de Toxicidad , Animales , Humanos , Investigación
12.
Assay Drug Dev Technol ; 4(1): 73-82, 2006 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-16506891

RESUMEN

Inhibition of the delayed-rectifier potassium channel current, human ether-a-go-go (hERG), by pharmaceutical agents can lead to acquired long QT syndrome and the generation of potentially lethal arrhythmias and sudden death. There remains an unmet need for higher-throughput assays to screen compounds in preclinical development for the potential to block hERG and cause QT prolongation. We evaluated the rubidium efflux assay for its ability to determine block of the hERG potassium channel. hERG-transfected human embryonic kidney-293 cells were cultured on 96-well assay plates and loaded with rubidium ion by incubating in media in which potassium was replaced by 5.4 mM Rb+. Cells were exposed to test compounds and then depolarized with a K+ channel opening buffer containing 50 mM K+. The supernatant was removed, and cells were lysed using 0.1% Triton X-100. Concentration-response curves were generated for test agents by determining the Rb+ efflux using a flame atomic absorption spectrometer. Multiple trials with cisapride yielded 50% inhibitory concentration values between 308.1 +/- 11 nM to 456.3 +/- 24 nM for inhibition of Rb+ efflux and a Z factor of 0.80 +/- 0.07 (n = 5 plates, 12 wells per plate). The values for inhibition of the hERG channel exhibited a rightward shift in potency as compared to those measured using electrophysiological techniques. In addition, we evaluated 19 blinded compounds at 10 microM in the Rb+ efflux assay, and compared results to those using patch clamp electrophysiology and the dofetilide displacement binding assay. The dofetilide displacement binding assay yielded a good correlation with electrophysiological measurements of hERG block. The rubidium efflux assay lacked sensitivity to consistently identify significant channel blockade. In conclusion, the rubidium efflux assay provides a higher-throughput means to identify potent hERG channel blocking agents, but lacks the sensitivity required to accurately determine the potency of blockade.


Asunto(s)
Canales de Potasio Éter-A-Go-Go/antagonistas & inhibidores , Canales de Potasio Éter-A-Go-Go/fisiología , Rubidio/metabolismo , Línea Celular , Membrana Celular/efectos de los fármacos , Membrana Celular/fisiología , Electrofisiología/métodos , Humanos , Riñón , Cinética , Fenetilaminas/farmacología , Sulfonamidas/farmacología
13.
Toxicol Sci ; 90(1): 149-58, 2006 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-16357009

RESUMEN

Embryonic stem (ES) cells offer unprecedented opportunities for in vitro drug discovery and safety assessment of compounds. Cardiomyocytes derived from ES cells enable development of predictive cardiotoxicity models to increase the safety of novel drugs. Heterogeneity of differentiated ES cells limits the development of reliable in vitro models for compound screening. We report an innovative and robust approach to isolate ES-derived cardiomyocytes using laser microdissection and pressure catapulting (LMPC). LMPC cells were readily applied onto 96-well format in vitro pharmacology assays. The expression of developmental and functional cardiac markers, Nkx 2.5, MLC2V, GATA-4, Connexin 43, Connexin 45, Serca-2a, cardiac alpha actin, and phospholamban, among others, was confirmed in LMPC ES-derived cardiomyocytes. Functional assays exhibited cardiac-like response to increased extracellular calcium (5.4 mM extracellular Ca2+) and L-type calcium channel antagonist (1 microM nifedipine). In conclusion, laser microdissection and pressure catapulting is a robust technology to isolate homogeneous ES-derived cell types from heterogeneous populations applicable to assay development.


Asunto(s)
Cardiopatías/inducido químicamente , Microscopía Confocal/métodos , Miocitos Cardíacos/efectos de los fármacos , Células Madre/efectos de los fármacos , Xenobióticos/toxicidad , Animales , Bioensayo/métodos , Biomarcadores/metabolismo , Calcio/metabolismo , Calcio/farmacología , Células Cultivadas , Evaluación Preclínica de Medicamentos/métodos , Corazón Fetal/citología , Perfilación de la Expresión Génica , Regulación de la Expresión Génica/efectos de los fármacos , Cardiopatías/patología , Rayos Láser , Ratones , Ratones Endogámicos DBA , Microdisección/métodos , Miocitos Cardíacos/metabolismo , Miocitos Cardíacos/patología , Nifedipino/farmacología , Análisis de Secuencia por Matrices de Oligonucleótidos , Células Madre/metabolismo , Células Madre/patología
14.
J Vis Exp ; (114)2016 Aug 30.
Artículo en Inglés | MEDLINE | ID: mdl-27684630

RESUMEN

Here, we describe a protocol to perform long-term co-culture of multi-species human gut microbiome with microengineered intestinal villi in a human gut-on-a-chip microphysiological device. We recapitulate the intestinal lumen-capillary tissue interface in a microfluidic device, where physiological mechanical deformations and fluid shear flow are constantly applied to mimic peristalsis. In the lumen microchannel, human intestinal epithelial Caco-2 cells are cultured to form a 'germ-free' villus epithelium and regenerate small intestinal villi. Pre-cultured microbial cells are inoculated into the lumen side to establish a host-microbe ecosystem. After microbial cells adhere to the apical surface of the villi, fluid flow and mechanical deformations are resumed to produce a steady-state microenvironment in which fresh culture medium is constantly supplied and unbound bacteria (as well as bacterial wastes) are continuously removed. After extended co-culture from days to weeks, multiple microcolonies are found to be randomly located between the villi, and both microbial and epithelial cells remain viable and functional for at least one week in culture. Our co-culture protocol can be adapted to provide a versatile platform for other host-microbiome ecosystems that can be found in various human organs, which may facilitate in vitro study of the role of human microbiome in orchestrating health and disease.

15.
Tissue Eng Part C Methods ; 22(5): 509-15, 2016 05.
Artículo en Inglés | MEDLINE | ID: mdl-26993746

RESUMEN

Studies on hematopoiesis currently rely on animal models because in vitro culture methods do not accurately recapitulate complex bone marrow physiology. We recently described a bone marrow-on-a-chip microfluidic device that enables the culture of living hematopoietic bone marrow and mimics radiation toxicity in vitro. In the present study, we used this microdevice to demonstrate continuous blood cell production in vitro and model bone marrow responses to potential radiation countermeasure drugs. The device maintained mouse hematopoietic stem and progenitor cells in normal proportions for at least 2 weeks in culture. Increases in the number of leukocytes and red blood cells into the microfluidic circulation also could be detected over time, and addition of erythropoietin induced a significant increase in erythrocyte production. Exposure of the bone marrow chip to gamma radiation resulted in reduction of leukocyte production, and treatment of the chips with two potential therapeutics, granulocyte-colony stimulating factor or bactericidal/permeability-increasing protein (BPI), induced significant increases in the number of hematopoietic stem cells and myeloid cells in the fluidic outflow. In contrast, BPI was not found to have any effect when analyzed using static marrow cultures, even though it has been previously shown to accelerate recovery from radiation-induced toxicity in vivo. These findings demonstrate the potential value of the bone marrow-on-a-chip for modeling blood cell production, monitoring responses to hematopoiesis-modulating drugs, and testing radiation countermeasures in vitro.


Asunto(s)
Médula Ósea/patología , Rayos gamma/efectos adversos , Hematopoyesis/fisiología , Células Madre Hematopoyéticas/citología , Técnicas Analíticas Microfluídicas/instrumentación , Modelos Biológicos , Células Mieloides/citología , Animales , Péptidos Catiónicos Antimicrobianos/administración & dosificación , Proteínas Sanguíneas/administración & dosificación , Médula Ósea/efectos de la radiación , Factor Estimulante de Colonias de Granulocitos/administración & dosificación , Hematopoyesis/efectos de la radiación , Células Madre Hematopoyéticas/efectos de la radiación , Ratones , Ratones Endogámicos C57BL , Células Mieloides/efectos de la radiación
16.
Cell Syst ; 3(5): 456-466.e4, 2016 11 23.
Artículo en Inglés | MEDLINE | ID: mdl-27894999

RESUMEN

Smoking represents a major risk factor for chronic obstructive pulmonary disease (COPD), but it is difficult to characterize smoke-induced injury responses under physiological breathing conditions in humans due to patient-to-patient variability. Here, we show that a small airway-on-a-chip device lined by living human bronchiolar epithelium from normal or COPD patients can be connected to an instrument that "breathes" whole cigarette smoke in and out of the chips to study smoke-induced pathophysiology in vitro. This technology enables true matched comparisons of biological responses by culturing cells from the same individual with or without smoke exposure. These studies led to identification of ciliary micropathologies, COPD-specific molecular signatures, and epithelial responses to smoke generated by electronic cigarettes. The smoking airway-on-a-chip represents a tool to study normal and disease-specific responses of the human lung to inhaled smoke across molecular, cellular and tissue-level responses in an organ-relevant context.


Asunto(s)
Pulmón , Sistemas Electrónicos de Liberación de Nicotina , Células Epiteliales , Humanos , Enfermedad Pulmonar Obstructiva Crónica , Respiración , Fumar
17.
ALTEX ; 33(3): 272-321, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27180100

RESUMEN

The recent advent of microphysiological systems - microfluidic biomimetic devices that aspire to emulate the biology of human tissues, organs and circulation in vitro - is envisaged to enable a global paradigm shift in drug development. An extraordinary US governmental initiative and various dedicated research programs in Europe and Asia have led recently to the first cutting-edge achievements of human single-organ and multi-organ engineering based on microphysiological systems. The expectation is that test systems established on this basis would model various disease stages, and predict toxicity, immunogenicity, ADME profiles and treatment efficacy prior to clinical testing. Consequently, this technology could significantly affect the way drug substances are developed in the future. Furthermore, microphysiological system-based assays may revolutionize our current global programs of prioritization of hazard characterization for any new substances to be used, for example, in agriculture, food, ecosystems or cosmetics, thus, replacing laboratory animal models used currently. Thirty-six experts from academia, industry and regulatory bodies present here the results of an intensive workshop (held in June 2015, Berlin, Germany). They review the status quo of microphysiological systems available today against industry needs, and assess the broad variety of approaches with fit-for-purpose potential in the drug development cycle. Feasible technical solutions to reach the next levels of human biology in vitro are proposed. Furthermore, key organ-on-a-chip case studies, as well as various national and international programs are highlighted. Finally, a roadmap into the future is outlined, to allow for more predictive and regulatory-accepted substance testing on a global scale.


Asunto(s)
Alternativas a las Pruebas en Animales , Sustancias Peligrosas/toxicidad , Dispositivos Laboratorio en un Chip , Células Madre/fisiología , Pruebas de Toxicidad/métodos , Animales , Línea Celular
18.
Nat Rev Drug Discov ; 14(4): 248-60, 2015 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-25792263

RESUMEN

Improving the effectiveness of preclinical predictions of human drug responses is critical to reducing costly failures in clinical trials. Recent advances in cell biology, microfabrication and microfluidics have enabled the development of microengineered models of the functional units of human organs - known as organs-on-chips - that could provide the basis for preclinical assays with greater predictive power. Here, we examine the new opportunities for the application of organ-on-chip technologies in a range of areas in preclinical drug discovery, such as target identification and validation, target-based screening, and phenotypic screening. We also discuss emerging drug discovery opportunities enabled by organs-on-chips, as well as important challenges in realizing the full potential of this technology.


Asunto(s)
Simulación por Computador , Descubrimiento de Drogas/métodos , Descubrimiento de Drogas/tendencias , Animales , Evaluación Preclínica de Medicamentos , Industria Farmacéutica/tendencias , Ensayos Analíticos de Alto Rendimiento , Humanos , Modelos Biológicos , Farmacocinética , Enfermedades Raras
19.
ALTEX ; 31(4): 441-77, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-25027500

RESUMEN

Integrated approaches using different in vitro methods in combination with bioinformatics can (i) increase the success rate and speed of drug development; (ii) improve the accuracy of toxicological risk assessment; and (iii) increase our understanding of disease. Three-dimensional (3D) cell culture models are important building blocks of this strategy which has emerged during the last years. The majority of these models are organotypic, i.e., they aim to reproduce major functions of an organ or organ system. This implies in many cases that more than one cell type forms the 3D structure, and often matrix elements play an important role. This review summarizes the state of the art concerning commonalities of the different models. For instance, the theory of mass transport/metabolite exchange in 3D systems and the special analytical requirements for test endpoints in organotypic cultures are discussed in detail. In the next part, 3D model systems for selected organs--liver, lung, skin, brain--are presented and characterized in dedicated chapters. Also, 3D approaches to the modeling of tumors are presented and discussed. All chapters give a historical background, illustrate the large variety of approaches, and highlight up- and downsides as well as specific requirements. Moreover, they refer to the application in disease modeling, drug discovery and safety assessment. Finally, consensus recommendations indicate a roadmap for the successful implementation of 3D models in routine screening. It is expected that the use of such models will accelerate progress by reducing error rates and wrong predictions from compound testing.


Asunto(s)
Alternativas a las Pruebas en Animales/métodos , Técnicas de Cultivo de Célula/instrumentación , Técnicas de Cultivo de Célula/métodos , Dispositivos Laboratorio en un Chip , Animales , Bioensayo/instrumentación , Bioensayo/métodos , Modelos Biológicos
20.
Nat Protoc ; 8(11): 2135-57, 2013 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-24113786

RESUMEN

'Organs-on-chips' are microengineered biomimetic systems containing microfluidic channels lined by living human cells, which replicate key functional units of living organs to reconstitute integrated human organ-level pathophysiology in vitro. These microdevices can be used to test efficacy and toxicity of drugs and chemicals, and to create in vitro models of human disease. Thus, they potentially represent low-cost alternatives to conventional animal models for pharmaceutical, chemical and environmental applications. Here we describe a protocol for the fabrication, microengineering and operation of these microfluidic organ-on-chip systems. First, microengineering is used to fabricate a multilayered microfluidic device that contains two parallel elastomeric microchannels separated by a thin porous flexible membrane, along with two full-height, hollow vacuum chambers on either side; this requires ∼3.5 d to complete. To create a 'breathing' lung-on-a-chip that mimics the mechanically active alveolar-capillary interface of the living human lung, human alveolar epithelial cells and microvascular endothelial cells are cultured in the microdevice with physiological flow and cyclic suction applied to the side chambers to reproduce rhythmic breathing movements. We describe how this protocol can be easily adapted to develop other human organ chips, such as a gut-on-a-chip lined by human intestinal epithelial cells that experiences peristalsis-like motions and trickling fluid flow. Also, we discuss experimental techniques that can be used to analyze the cells in these organ-on-chip devices.


Asunto(s)
Biomimética/métodos , Dispositivos Laboratorio en un Chip , Microtecnología/métodos , Técnicas de Cultivo de Tejidos , Biomimética/instrumentación , Técnicas de Cultivo de Célula , Humanos , Pulmón/citología , Pulmón/fisiología , Microfluídica/instrumentación , Microfluídica/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA