Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros

Bases de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Crit Care Med ; 44(6): 1098-108, 2016 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-26807682

RESUMEN

OBJECTIVES: Despite protocols incorporating spontaneous breathing trials, 31% of ICU patients experience difficult or prolonged weaning from mechanical ventilation. Nonfatiguing modes such as pressure support ventilation are recommended. Proportional assist ventilation provides assistance in proportion to patient effort, which may optimize weaning. However, it is not known how proportional assist ventilation performs relative to pressure support ventilation over a prolonged period in the complex ICU setting. The purpose of this study was to compare the physiologic and clinical performance (failure rate), safety, and feasibility of protocols using daily spontaneous breathing trial plus pressure support ventilation versus proportional assist ventilation until ventilation discontinuation. DESIGN: Single-center, unblinded pilot randomized controlled trial. SETTING: Medical-surgical ICU of a tertiary-care hospital. PATIENTS: Adult patients intubated greater than 36 hours were randomized if they met eligibility criteria for partial ventilatory support, tolerated pressure support ventilation greater than or equal to 30 minutes, and either failed or did not meet criteria for a spontaneous breathing trial. INTERVENTIONS: Patients were randomized to the pressure support ventilation or proportional assist ventilation protocol (PAV+, Puritan Bennett 840; Covidien, Boulder, CO). Both protocols used progressive decreases in level of assistance as tolerated, coupled with daily assessment for spontaneous breathing trials. MEASUREMENTS AND MAIN RESULTS: Of 54 patients randomized, outcome data are available for 50 patients; 27 were randomized to receive proportional assist ventilation and 23 to receive pressure support ventilation. There were no adverse events linked to the study interventions, and protocol violations were infrequent. Recruitment was slower than projected (1.3 patients per month). The median (interquartile range) time from randomization to successful extubation was 3.9 days (2.8-8.4 d) on proportional assist ventilation versus 4.9 days (2.9-26.3 d) on pressure support ventilation (p = 0.39). Time to live ICU discharge was 7.3 days (5.2-11.4 d) on proportional assist ventilation versus 12.4 days (7.5-30.8 d) on pressure support ventilation (p = 0.03). CONCLUSION: This pilot study demonstrates the utility, safety, and feasibility of the weaning protocols and provides important information to guide the design of a future randomized controlled trial comparing weaning from mechanical ventilation on pressure support ventilation versus proportional assist ventilation.


Asunto(s)
Soporte Ventilatorio Interactivo , Respiración con Presión Positiva Intermitente , Desconexión del Ventilador/métodos , Anciano , Extubación Traqueal , Antipsicóticos/administración & dosificación , Femenino , Humanos , Hipnóticos y Sedantes/administración & dosificación , Unidades de Cuidados Intensivos , Soporte Ventilatorio Interactivo/efectos adversos , Respiración con Presión Positiva Intermitente/efectos adversos , Tiempo de Internación , Masculino , Presiones Respiratorias Máximas , Persona de Mediana Edad , Narcóticos/administración & dosificación , Proyectos Piloto , Estudios Prospectivos , Volumen de Ventilación Pulmonar , Factores de Tiempo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA