Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros

Bases de datos
Tipo de estudio
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Environ Sci Technol ; 57(10): 4153-4166, 2023 03 14.
Artículo en Inglés | MEDLINE | ID: mdl-36853955

RESUMEN

There is a design-to-function knowledge gap regarding how engineered stream restoration structures can maximize hyporheic contaminant attenuation. Surface and subsurface structures have each been studied in isolation as techniques to restore hyporheic exchange, but surface-subsurface structures have not been investigated or optimized in an integrated manner. Here, we used a numerical model to systematically evaluate key design variables for combined surface (i.e., weir height and length) and subsurface (i.e., upstream and downstream baffle plate spacing) structures. We also compared performance metrics that place differing emphasis on hyporheic flux versus transit times. We found that surface structures tended to create higher flux, shorter transit time flowpaths, whereas subsurface structures promoted moderate-flux, longer transit time flowpaths. Optimal combined surface-subsurface structures could increase fluxes and transit times simultaneously, thus providing conditions for contaminant attenuation that were many times more effective than surface or subsurface structures alone. All performance metrics were improved by the presence of an upstream plate and the absence of a downstream plate. Increasing the weir length tended to improve all metrics, whereas the optimal weir height varied based on metrics. These findings may improve stream restoration by better aligning specific restoration goals with appropriate performance metrics and hyporheic structure designs.


Asunto(s)
Agua Subterránea , Agua , Movimientos del Agua , Benchmarking
2.
Environ Sci Technol ; 52(21): 12285-12294, 2018 11 06.
Artículo en Inglés | MEDLINE | ID: mdl-30293423

RESUMEN

First-order half-lives for 26 trace organic compounds (TrOCs) were determined in the hyporheic zone (HZ) and along a 3 km reach of a first-order stream in South Australia during both dry and wet seasons. Two salt tracer experiments were conducted and evaluated using a transient storage model to characterize seasonal differences in stream residence time and transient storage. Lagrangian and time-integrated surface water sampling were conducted to calculate half-lives in the surface water. Half-lives in the HZ were calculated using porewater samples obtained from a modified mini-point sampler and hyporheic residence times measured via active heat-pulse sensing. Half of the investigated TrOCs (e.g., oxazepam, olmesartan, candesartan) were not significantly removed along both the investigated river stretch and the sampled hyporheic flow paths. The remaining TrOCs (e.g., metformin, guanylurea, valsartan) were found to be significantly removed in the HZ and along the river stretch with relative removals in the HZ correlating to reach-scale relative removals. Using the modeled transport parameters, it was estimated that wet season reach-scale removal of TrOCs was predominately caused by removal in the HZ when the intensity of hyporheic exchange was also higher. Factors that increase HZ exchange are thus likely to promote in-stream reactivity of TrOCs.


Asunto(s)
Agua Subterránea , Compuestos Orgánicos , Ríos , Estaciones del Año , Australia del Sur
3.
Data Brief ; 51: 109756, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-38020435

RESUMEN

Braided rivers play a significant role in replenishing groundwater, but our understanding of how these recharge rates fluctuate over time remains limited. Traditional techniques for gauging groundwater recharge are ineffective for studying complex braided river systems due to their insufficient spatiotemporal resolution. To address this gap, active-distributed temperature sensing (A-DTS) was used. This method combines fiber optic temperature measurements with an active heat source, enabling quantification of groundwater fluxes. In this study, twelve consecutive A-DTS surveys were conducted on a 100 m long hybrid fiber optic cable to a depth of 5 m beneath the Waikirikiri Selwyn River. This experiment was conducted during a period of relatively stable river stage and flow, highlighting the effectiveness of using A-DTS to measure temporal changes in groundwater recharge.

4.
FEMS Microbiol Ecol ; 94(10)2018 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-30107498

RESUMEN

Groundwater is increasingly used globally for domestic, industrial and agricultural production. While many studies have focused on groundwater as a resource, the diverse ecosystems within are often ignored. Here, we assess 54 Southern South Australian groundwater microbial communities from the populated part of the state to assess their status and dynamics in isolated groundwater systems. We observed a strong site-to-site individuality in groundwater bacterial communities, likely due to the isolated nature of groundwater bodies leading to unique ecosystems. Rank abundance analysis indicates bacterial diversity is maintained even at low abundances and that the distribution fits classical ecological models for strong competition in resource-limited environments. Combined, our data indicates that despite overrepresentation of pollutant-associated bacterial orders in and around the Adelaide metropolitan area, microbial communities remain diverse and show little evidence of converging on a common pollutant-effected community.


Asunto(s)
Agua Subterránea/microbiología , Microbiología del Agua , Biodiversidad , Ecosistema , Agua Subterránea/química , Australia del Sur , Contaminantes del Agua/análisis
5.
Sci Total Environ ; 574: 272-281, 2017 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-27639024

RESUMEN

Obtaining reliable estimates of vertical groundwater flows remains a challenge but is of critical importance to the management of groundwater resources. When large scale land clearing or groundwater extraction occurs, methods based on water table fluctuations or water chemistry are unreliable. As an alternative, a number of methods based on temperature-depth (T-z) profiles are available to provide vertical groundwater flow estimates from which recharge rates may be calculated. However, methods that invoke steady state assumptions have been shown to be inappropriate for sites that have experienced land surface warming. Analytical solutions that account for surface warming are available, but they typically include unrealistic or restrictive assumptions (e.g. no flow initial conditions or linear surface warming). Here, we use a new analytical solution and associated computer program (FAST) that provides flexible initial and boundary conditions to estimate fluxes using T-z profiles from the Willunga Super Science Site, a complex, but densely instrumented groundwater catchment in South Australia. T-z profiles from seven wells (ranging from high elevation to near sea level) were utilised, in addition to mean annual air temperatures at nearby weather stations to estimate boundary conditions, and thermal properties were estimated from down borehole geophysics. Temperature based flux estimates were 5 to 23mmy-1, which are similar to those estimated using chloride mass balance. This study illustrates that T-z profiles can be studied to estimate recharge in environments where more commonly applied methods fail.

6.
Ground Water ; 52(6): 943-51, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-24475970

RESUMEN

Techniques for characterizing the hydraulic properties and groundwater flow processes of aquifers are essential to design hydrogeologic conceptual models. In this study, rapid time series temperature profiles within open-groundwater wells in fractured rock were measured using fiber optic distributed temperature sensing (FO-DTS). To identify zones of active groundwater flow, two continuous electrical heating cables were installed alongside a FO-DTS cable to heat the column of water within the well and to create a temperature difference between the ambient temperature of the groundwater in the aquifer and that within the well. Additional tests were performed to examine the effects of pumping on hydraulic fracture interconnectivity around the well and to identify zones of increased groundwater flow. High- and low-resolution FO-DTS cable configurations were examined to test the sensitivities of the technique and compared with downhole video footage and geophysical logging to confirm the zones of active groundwater flow. Two examples are presented to demonstrate the usefulness of this new technique for rapid characterization of fracture zones in open boreholes. The combination of the FO-DTS and heating cable has excellent scope as a rapid appraisal tool for borehole construction design and improving hydrogeologic conceptual models.


Asunto(s)
Monitoreo del Ambiente/métodos , Agua Subterránea , Temperatura , Movimientos del Agua
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA