Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
1.
Neuromodulation ; 25(2): 161-170, 2022 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-35125135

RESUMEN

OBJECTIVES: Despite recent advances in depression treatment, many patients still do not respond to serial conventional therapies and are considered "treatment resistant." Deep brain stimulation (DBS) has therapeutic potential in this context. This comprehensive review of recent studies of DBS for depression in animal models identifies potential biomarkers for improving therapeutic efficacy and predictability of conventional DBS to aid future development of closed-loop control of DBS systems. MATERIALS AND METHODS: A systematic search was performed in Pubmed, EMBASE, and Cochrane Review using relevant keywords. Overall, 56 animal studies satisfied the inclusion criteria. RESULTS: Outcomes were divided into biochemical/physiological, electrophysiological, and behavioral categories. Promising biomarkers include biochemical assays (in particular, microdialysis and electrochemical measurements), which provide real-time results in awake animals. Electrophysiological tests, showing changes at both the target site and downstream structures, also revealed characteristic changes at several anatomic targets (such as the medial prefrontal cortex and locus coeruleus). However, the substantial range of models and DBS targets limits the ability to draw generalizable conclusions in animal behavioral models. CONCLUSIONS: Overall, DBS is a promising therapeutic modality for treatment-resistant depression. Different outcomes have been used to assess its efficacy in animal studies. From the review, electrophysiological and biochemical markers appear to offer the greatest potential as biomarkers for depression. However, to develop closed-loop DBS for depression, additional preclinical and clinical studies with a focus on identifying reliable, safe, and effective biomarkers are warranted.


Asunto(s)
Estimulación Encefálica Profunda , Animales , Biomarcadores , Depresión/terapia , Humanos , Modelos Animales
2.
Neurosurg Focus ; 49(1): E6, 2020 07.
Artículo en Inglés | MEDLINE | ID: mdl-32610297

RESUMEN

The development of closed-loop deep brain stimulation (DBS) systems represents a significant opportunity for innovation in the clinical application of neurostimulation therapies. Despite the highly dynamic nature of neurological diseases, open-loop DBS applications are incapable of modifying parameters in real time to react to fluctuations in disease states. Thus, current practice for the designation of stimulation parameters, such as duration, amplitude, and pulse frequency, is an algorithmic process. Ideal stimulation parameters are highly individualized and must reflect both the specific disease presentation and the unique pathophysiology presented by the individual. Stimulation parameters currently require a lengthy trial-and-error process to achieve the maximal therapeutic effect and can only be modified during clinical visits. The major impediment to the development of automated, adaptive closed-loop systems involves the selection of highly specific disease-related biomarkers to provide feedback for the stimulation platform. This review explores the disease relevance of neurochemical and electrophysiological biomarkers for the development of closed-loop neurostimulation technologies. Electrophysiological biomarkers, such as local field potentials, have been used to monitor disease states. Real-time measurement of neurochemical substances may be similarly useful for disease characterization. Thus, the introduction of measurable neurochemical analytes has significantly expanded biomarker options for feedback-sensitive neuromodulation systems. The potential use of biomarker monitoring to advance neurostimulation approaches for treatment of Parkinson's disease, essential tremor, epilepsy, Tourette syndrome, obsessive-compulsive disorder, chronic pain, and depression is examined. Further, challenges and advances in the development of closed-loop neurostimulation technology are reviewed, as well as opportunities for next-generation closed-loop platforms.


Asunto(s)
Encéfalo/fisiopatología , Estimulación Encefálica Profunda , Enfermedades del Sistema Nervioso/terapia , Trastorno Obsesivo Compulsivo/terapia , Estimulación Encefálica Profunda/métodos , Temblor Esencial/terapia , Humanos , Enfermedad de Parkinson/terapia , Síndrome de Tourette/fisiopatología
3.
Rev Anal Chem ; 39(1): 188-199, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-33883813

RESUMEN

Neurochemical recording techniques have expanded our understanding of the pathophysiology of neurological disorders, as well as the mechanisms of action of treatment modalities like deep brain stimulation (DBS). DBS is used to treat diseases such as Parkinson's disease, Tourette syndrome, and obsessive-compulsive disorder, among others. Although DBS is effective at alleviating symptoms related to these diseases and improving the quality of life of these patients, the mechanism of action of DBS is currently not fully understood. A leading hypothesis is that DBS modulates the electrical field potential by modifying neuronal firing frequencies to non-pathological rates thus providing therapeutic relief. To address this gap in knowledge, recent advances in electrochemical sensing techniques have given insight into the importance of neurotransmitters, such as dopamine, serotonin, glutamate, and adenosine, in disease pathophysiology. These studies have also highlighted their potential use in tandem with electrophysiology to serve as biomarkers in disease diagnosis and progression monitoring, as well as characterize response to treatment. Here, we provide an overview of disease-relevant neurotransmitters and their roles and implications as biomarkers, as well as innovations to the biosensors used to record these biomarkers. Furthermore, we discuss currently available neurochemical and electrophysiological recording devices, and discuss their viability to be implemented into the development of a closed-loop DBS system.

5.
Sci Rep ; 11(1): 17492, 2021 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-34471205

RESUMEN

External ventricular drainage (EVD) is an emergency neurosurgical procedure to decrease intracranial pressure through a catheter mediated drainage of cerebrospinal fluid. Most EVD catheters are placed using free hands without direct visualization of the target and catheter trajectory, leading to a high rate of complications- hemorrhage, brain injury and suboptimal catheter placement. Use of stereotactic systems can prevent these complications. However, they have found limited application for this procedure due to their long set-up time and expensive hardware. Therefore, we have developed and pre-clinically validated a novel 3D printed stereotactic system for rapid and accurate implantation of EVD catheters. Its mechanical and imaging accuracies were found to be at par with clinical stereotactic systems. Preclinical trial in human cadaver specimens revealed improved targeting accuracy achieved within an acceptable time frame compared to the free hand technique. CT angiography emulated using cadaver specimen with radio-opaque vascular contrast showed vessel free catheter trajectory. This could potentially translate to reduced hemorrhage rate. Thus, our 3D printed stereotactic system offers the potential to improve the accuracy and safety of EVD catheter placement for patients without significantly increasing the procedure time.


Asunto(s)
Drenaje/métodos , Hipertensión Intracraneal/cirugía , Procedimientos Neuroquirúrgicos/métodos , Técnicas Estereotáxicas , Humanos , Hipertensión Intracraneal/diagnóstico por imagen , Tomografía Computarizada por Rayos X
6.
ACS Omega ; 6(10): 6607-6613, 2021 Mar 16.
Artículo en Inglés | MEDLINE | ID: mdl-33748573

RESUMEN

Dysregulation of the neurotransmitter dopamine (DA) is implicated in several neuropsychiatric conditions. Multiple-cyclic square-wave voltammetry (MCSWV) is a state-of-the-art technique for measuring tonic DA levels with high sensitivity (<5 nM), selectivity, and spatiotemporal resolution. Currently, however, analysis of MCSWV data requires manual, qualitative adjustments of analysis parameters, which can inadvertently introduce bias. Here, we demonstrate the development of a computational technique using a statistical model for standardized, unbiased analysis of experimental MCSWV data for unbiased quantification of tonic DA. The oxidation current in the MCSWV signal was predicted to follow a lognormal distribution. The DA-related oxidation signal was inferred to be present in the top 5% of this analytical distribution and was used to predict a tonic DA level. The performance of this technique was compared against the previously used peak-based method on paired in vivo and post-calibration in vitro datasets. Analytical inference of DA signals derived from the predicted statistical model enabled high-fidelity conversion of the in vivo current signal to a concentration value via in vitro post-calibration. As a result, this technique demonstrated reliable and improved estimation of tonic DA levels in vivo compared to the conventional manual post-processing technique using the peak current signals. These results show that probabilistic inference-based voltammetry signal processing techniques can standardize the determination of tonic DA concentrations, enabling progress toward the development of MCSWV as a robust research and clinical tool.

7.
Neurol India ; 68(3): 652-653, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32643680

RESUMEN

A suction pressure control valve (SPCV) for microneurosurgery is designed to place control of safe suction pressure in the hands of an operating neurosurgeon. Tumor tissue needs more negative suction pressure as compared to normal brain tissue, cranial nerves, and vessels in the neurosurgical operating field. The authors present the details of a prototype of a simple and inexpensive device for dynamic adjustment of negative suction pressure by the surgeon or the assistant while working on different tissue types during microneurosurgery.


Asunto(s)
Encéfalo , Microcirugia , Encéfalo/cirugía , Nervios Craneales , Humanos , Succión
8.
Front Neurosci ; 14: 869, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32973432

RESUMEN

INTRODUCTION: Striatal tonic dopamine increases rapidly during global cerebral hypoxia. This phenomenon has previously been studied using microdialysis techniques which have relatively poor spatio-temporal resolution. In this study, we measured changes in tonic dopamine during hypoxia (death) in real time with high spatio-temporal resolution using novel multiple cyclic square wave voltammetry (MCSWV) and conventional fast scan cyclic voltammetry (FSCV) techniques. METHODS: MCSWV and FSCV were used to measure dopamine release at baseline and during hypoxia induced by euthanasia, with and without prior alpha-methyl-p-tyrosine (AMPT) treatment, in urethane anesthetized male Sprague-Dawley rats. RESULTS: Baseline tonic dopamine levels were found to be 274.1 ± 49.4 nM (n = 5; mean ± SEM). Following intracardiac urethane injection, the tonic levels increased to a peak concentration of 1753.8 ± 95.7 nM within 3.6 ± 0.6 min (n = 5), followed by a decline to 50.7 ± 21.5 nM (n = 4) at 20 min. AMPT pre-treatment significantly reduced this dopamine peak to 677.9 ± 185.7 nM (n = 3). FSCV showed a significantly higher (p = 0.0079) peak dopamine release of 6430.4 ± 1805.7 nM (n = 5) during euthanasia-induced cerebral hypoxia. CONCLUSION: MCSWV is a novel tool to study rapid changes in tonic dopamine release in vivo during hypoxia. We found a 6-fold increase in peak dopamine levels during hypoxia which was attenuated with AMPT pre-treatment. These changes are much lower compared to those found with microdialysis. This could be due to improved estimation of baseline tonic dopamine with MCSWV. Higher dopamine response measured with FSCV could be due to an increased oxidation current from electroactive interferents.

9.
Artículo en Inglés | MEDLINE | ID: mdl-33362946

RESUMEN

Background: Non-invasive peripheral nerve stimulation, also referred to as transcutaneous afferent patterned stimulation (TAPS), reduces hand tremor in essential tremor (ET) subjects. However, the mechanism of action of TAPS is unknown. Here, we investigated changes in brain metabolism over three months of TAPS use in ET subjects. Methods: This was an interventional, open label, single group study enrolling 5 ET subjects. They received 40 minutes of TAPS treatment twice daily for 90 days. Brain metabolic activity and tremor severity were measured using 18F-fluorodeoxyglucose (FDG) PET/CT, and the Tremor Research Group Essential Tremor Rating Assessment Scale (TETRAS), respectively, at baseline and after 90 days. Tremor power and frequency was measured before and after all TAPS sessions using an onboard three-axis accelerometer. Results: FDG PET/CT revealed areas of hypermetabolism in ipsilateral cerebellar hemisphere and hypometabolism in contralateral cerebellar hemisphere following 90 days of TAPS treatment, compared to day one (uncorrected p value <0.05). Paired pre-post kinematic measurements over 90 days showed significantly decreased tremor power (p < 0.0001) but no change in tremor frequency. The TETRAS score on day 1 decreased from 6.5 ± 2.5 to 4.1 ± 1.8 following TAPS (p = 0.05). The pre-post TETRAS scores on day 90: 4.9 ± 1.5 and 4.1± 1 were lower than pre-TAPS TETRAS score on day 1 (p = 0.14 and 0.05, respectively). Conclusions: Our results suggest that longitudinal TAPS of the median and radial nerves modulates brain metabolism in areas instrumental to motor coordination and implicated in ET. Clinically, TAPS reduced tremor power, but had no effect on tremor frequency. This study paves the way for comprehensive studies in larger cohorts to further elucidate the mechanism of TAPS. Highlights: Non-invasive peripheral nerve stimulation, also referred to as transcutaneous afferent patterned stimulation (TAPS), reduces hand tremor in essential tremor subjects. Longitudinal TAPS therapy alters cerebellar metabolism, which can be a cause or consequence of tremor reduction. Cerebellar-premotor region connectivity may play a role in the anti-tremor effects of TAPS.


Asunto(s)
Cerebelo/diagnóstico por imagen , Terapia por Estimulación Eléctrica/métodos , Temblor Esencial/terapia , Nervio Mediano , Nervio Radial , Vías Aferentes , Anciano , Encéfalo/diagnóstico por imagen , Encéfalo/metabolismo , Cerebelo/metabolismo , Temblor Esencial/diagnóstico por imagen , Temblor Esencial/metabolismo , Femenino , Fluorodesoxiglucosa F18 , Mano , Humanos , Masculino , Persona de Mediana Edad , Tomografía Computarizada por Tomografía de Emisión de Positrones , Radiofármacos , Resultado del Tratamiento
10.
J Neural Eng ; 17(6)2020 12 16.
Artículo en Inglés | MEDLINE | ID: mdl-33142275

RESUMEN

Objective. Stereotactic technology enables fine navigation to small structures in the human body. While current stereotactic systems facilitate accurate targeting, they are mechanically cumbersome and limited in scope. Here, we hypothesized that a stereotactic system could be developed with a reduced footprint while maintaining broad targeting capabilities in order to improve versatility in frame placement location and surgical workflow.Approach. We designed a stereotactic system around the center-of-arc principle, with mechanical properties that would enable a compact design and ample targeting and trajectory maneuverability. To examine the opportunity for a low-cost rapidly-deployable system we developed two fabrication variants, one using three dimensional (3D)-printing and the other using conventional machining. Mechanical and image-guided accuracies were tested in phantom studies using magnetic resonance imaging (MRI) and computed tomography. Using human cadaver head specimens, we assessed the system's surgical workflow and its ability to reliably and accurately implant electrodes in deep brain stimulation (DBS) surgery.Main results. We developed a small 7.7 × 5.4 cm2device platform that rigidly mounts to curvilinear bone and supports the attachment of surgical instrumentation. Attachment of two surgical instruments, an imaging localizer and a compact targeting device, demonstrated successful MRI-guided intervention in phantom studies with a vector error of 1.79 ± 0.41 mm. Evaluation of the 3D-printed system for DBS surgery confirmed ease of device platform attachment and instrument functionality, as well as demonstrated a surgical targeting accuracy of 1.83 ± 0.15 mm. In addition, we found the surgical time to be 78.3 ± 5.4 min for bilateral electrode implantation.Significance. We developed a light and compact stereotactic system whose accuracy is on par with those used clinically. This technology is suitable for clinical translation and its flexibility in positioning will seamlessly expand the capabilities for stereotaxy to treat a wide range of conditions, both within neurosurgery and beyond.


Asunto(s)
Estimulación Encefálica Profunda , Imagenología Tridimensional , Estimulación Encefálica Profunda/métodos , Humanos , Imagenología Tridimensional/métodos , Imagen por Resonancia Magnética/métodos , Procedimientos Neuroquirúrgicos , Fantasmas de Imagen , Técnicas Estereotáxicas , Tomografía Computarizada por Rayos X
11.
J Neurosurg Spine ; 30(3): 332-336, 2018 12 07.
Artículo en Inglés | MEDLINE | ID: mdl-30544345

RESUMEN

Ossification of the ligamentum flavum (OLF) is a well-recognized but rare cause of thoracic myelopathy. Its subtle and variable clinical presentation often makes the diagnosis challenging. The treatment of symptomatic OLF requires surgical intervention, with the most common surgical procedure being a posterior decompression with or without instrumentation. Recurrence of ossification and stenosis after surgery is rare and usually occurs at the same intervertebral level. Multiple recurrences of ossification and stenosis are exceptionally rare. The authors report the case of OLF in a 60-year-old man who experienced recurrence of ossification and stenosis twice after posterior decompression surgeries alone. The patient was ultimately treated with revision decompression and instrumented fusion. The authors also present a pertinent review of the literature.


Asunto(s)
Ligamento Amarillo/cirugía , Osificación Heterotópica/cirugía , Enfermedades de la Médula Espinal/cirugía , Estenosis Espinal/cirugía , Constricción Patológica/cirugía , Descompresión Quirúrgica/efectos adversos , Descompresión Quirúrgica/métodos , Humanos , Masculino , Persona de Mediana Edad , Procedimientos Neuroquirúrgicos/efectos adversos , Osificación Heterotópica/complicaciones , Osificación Heterotópica/diagnóstico , Recurrencia , Enfermedades de la Médula Espinal/diagnóstico , Estenosis Espinal/diagnóstico , Vértebras Torácicas/cirugía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA