Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Health Res Policy Syst ; 10: 22, 2012 Jul 04.
Artículo en Inglés | MEDLINE | ID: mdl-22759725

RESUMEN

BACKGROUND: Resource-limited tropical countries are home to numerous infectious pathogens of both human and zoonotic origin. A capability for early detection to allow rapid outbreak containment and prevent spread to non-endemic regions is severely impaired by inadequate diagnostic laboratory capacity, the absence of a "cold chain" and the lack of highly trained personnel. Building up detection capacity in these countries by direct replication of the systems existing in developed countries is not a feasible approach and instead requires "leapfrogging" to the deployment of the newest diagnostic systems that do not have the infrastructure requirements of systems used in developed countries. METHODS: A laboratory for molecular diagnostics of infectious agents was established in Bo, Sierra Leone with a hybrid solar/diesel/battery system to ensure stable power supply and a satellite modem to enable efficient communication. An array of room temperature stabilization and refrigeration technologies for reliable transport and storage of reagents and biological samples were also tested to ensure sustainable laboratory supplies for diagnostic assays. RESULTS: The laboratory demonstrated its operational proficiency by conducting an investigation of a suspected avian influenza outbreak at a commercial poultry farm at Bo using broad range resequencing microarrays and real time RT-PCR. The results of the investigation excluded influenza viruses as a possible cause of the outbreak and indicated a link between the outbreak and the presence of Klebsiella pneumoniae. CONCLUSIONS: This study demonstrated that by application of a carefully selected set of technologies and sufficient personnel training, it is feasible to deploy and effectively use a broad-range infectious pathogen detection technology in a severely resource-limited setting.


Asunto(s)
Brotes de Enfermedades/prevención & control , Gripe Aviar/diagnóstico , Laboratorios/organización & administración , Análisis por Micromatrices/métodos , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa/métodos , Animales , Comunicación , Países en Desarrollo , Brotes de Enfermedades/veterinaria , Estabilidad de Medicamentos , Diagnóstico Precoz , Suministros de Energía Eléctrica , Indicadores y Reactivos , Gripe Aviar/epidemiología , Infecciones por Klebsiella/diagnóstico , Infecciones por Klebsiella/epidemiología , Infecciones por Klebsiella/veterinaria , Personal de Laboratorio/educación , Análisis por Micromatrices/veterinaria , Técnicas de Diagnóstico Molecular/métodos , Técnicas de Diagnóstico Molecular/veterinaria , Aves de Corral , Infecciones por Pseudomonas/diagnóstico , Infecciones por Pseudomonas/epidemiología , Infecciones por Pseudomonas/veterinaria , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa/veterinaria , Sierra Leona/epidemiología , Manejo de Especímenes
2.
Comput Biol Med ; 13(4): 257-64, 1983.
Artículo en Inglés | MEDLINE | ID: mdl-6661907

RESUMEN

A semi-automated system for evaluation of Doppler cerebral blood flow studies obtained from newborn infants is described. A low cost digitizer is used to convert the graphic data from the flow tracing to digital data. A small business computer is used to analyze the data and produce a chartable report. The reliability of the digitizer is also evaluated.


Asunto(s)
Circulación Cerebrovascular , Computadores , Recién Nacido , Microcomputadores , Velocidad del Flujo Sanguíneo , Humanos , Flujo Sanguíneo Regional , Ultrasonido
4.
J Ultrasound Med ; 6(10): 597-9, 1987 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-2960828

RESUMEN

This report compares six Doppler ultrasound measures of blood flow: Pourcelot's pulsatility index, Gosling's pulsatility index, area under the curve, systolic amplitude, diastolic amplitude, and mean amplitude. Recordings from an in vitro arterial model and from the anterior cerebral arteries in 33 newborn infants with asphyxia, intraventricular hemorrhage, or normal state were analyzed. In the model, all measures had excellent correlation with flow. Neonates were correctly classified according to diagnosis by the Doppler measures as follows: Pourcelot's pulsatility index (100%), Gosling's pulsatility index (97%), diastolic amplitude (94%), mean amplitude (76%), area under the curve (70%), and systolic amplitude (58%). The best accuracy was obtained with the pulsatility indices.


Asunto(s)
Asfixia Neonatal/diagnóstico , Hemorragia Cerebral/diagnóstico , Circulación Cerebrovascular , Recién Nacido/fisiología , Reología , Velocidad del Flujo Sanguíneo , Humanos , Modelos Cardiovasculares
5.
Cathet Cardiovasc Diagn ; 6(4): 469-73, 1980.
Artículo en Inglés | MEDLINE | ID: mdl-7471206

RESUMEN

A low-cost microcomputer system is used to calculate cardiac parameters from echocardiographic (Echo) measurements and produce a chartable report. The system is simple, uses Basic language, and provides for data storage.


Asunto(s)
Computadores , Electrocardiografía , Microcomputadores
6.
J Pediatr ; 100(6): 960-3, 1982 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-7086600

RESUMEN

The use of a modified pneumotonometer as a noninvasive method to measure intracranial pressure through the fontanel was evaluated in the animal laboratory and in the clinical setting. Pressure measured with the tonometer from a surgically created fontanel in an adult mongrel dog demonstrated good correlation with pressure measured from an epidural balloon catheter. Pressure recorded with the tonometer was compared with direct measurements in a single infant. There were 20 paired measurements with a correlation coefficient of 0.91. Fontanel pressure was measured in 72 healthy infants. The mean pressure was 7.0 mm Hg with a standard deviation of 1.75. This result compares favorably with previous reports utilizing other methods. The machine is safe and simple to use.


Asunto(s)
Recién Nacido , Presión Intracraneal , Cráneo , Animales , Perros , Equipos y Suministros , Estudios de Evaluación como Asunto , Humanos , Valores de Referencia
7.
J Pediatr ; 100(2): 291-6, 1982 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-6977024

RESUMEN

We examined the clinical significance of noninvasive intracranial pressure measurements and pulsatility indices in 74 infants with confirmed IC-IVh. The intracranial pressure measurements were obtained using the applanation principle, and the pulsatility indices were calculated from the Doppler flow velocity tracings of the anterior cerebral artery. Fifty-three infants (71.6%) who died had a significantly lower birth weight and gestational age than those who survived. Survival rate decreased significantly with increased intracranial pressure (P less than 0.0002) and increased pulsatility indices (P less than 0.0001). We found no significant relationship between outcome and the size of IC-IVH demonstrated by CT scan. Birth weight, intracranial pressure measurements, and cerebral arterial pulsatile flow changes appear to be major prognostic indicators in neonatal IC-IVH.


Asunto(s)
Angiografía Cerebral , Hemorragia Cerebral/diagnóstico por imagen , Ventriculografía Cerebral , Circulación Cerebrovascular , Enfermedades del Prematuro/diagnóstico por imagen , Presión Intracraneal , Pulso Arterial , Peso al Nacer , Hemorragia Cerebral/mortalidad , Edad Gestacional , Humanos , Enfermedad de la Membrana Hialina/diagnóstico por imagen , Enfermedad de la Membrana Hialina/mortalidad , Recién Nacido , Enfermedades del Prematuro/mortalidad , Unidades de Cuidado Intensivo Neonatal , Masculino , Estudios Prospectivos , Tomografía Computarizada por Rayos X
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA