Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
BMC Pediatr ; 22(1): 616, 2022 10 26.
Artículo en Inglés | MEDLINE | ID: mdl-36289537

RESUMEN

BACKGROUND: Supplementary treatment options after pediatric severe traumatic brain injury (TBI) are needed to improve neurodevelopmental outcome. Evidence suggests enhancement of brain delta waves via auditory phase-targeted stimulation might support neuronal reorganization, however, this method has never been applied in analgosedated patients on the pediatric intensive care unit (PICU). Therefore, we conducted a feasibility study to investigate this approach: In a first recording phase, we examined feasibility of recording over time and in a second stimulation phase, we applied stimulation to address tolerability and efficacy. METHODS: Pediatric patients (> 12 months of age) with severe TBI were included between May 2019 and August 2021. An electroencephalography (EEG) device capable of automatic delta wave detection and sound delivery through headphones was used to record brain activity and for stimulation (MHSL-SleepBand version 2). Stimulation tolerability was evaluated based on report of nurses, visual inspection of EEG data and clinical signals (heart rate, intracranial pressure), and whether escalation of therapy to reduce intracranial pressure was needed. Stimulation efficacy was investigated by comparing EEG power spectra of active stimulation versus muted stimulation (unpaired t-tests). RESULTS: In total, 4 out of 32 TBI patients admitted to the PICU (12.5%) between 4 and 15 years of age were enrolled in the study. All patients were enrolled in the recording phase and the last one also to the stimulation phase. Recordings started within 5 days after insult and lasted for 1-4 days. Overall, 23-88 h of EEG data per patient were collected. In patient 4, stimulation was enabled for 50 min: No signs of patient stress reactions were observed. Power spectrums between active and muted stimulation were not statistically different (all P > .05). CONCLUSION: Results suggests good feasibility of continuously applying devices needed for auditory stimulation over multiple days in pediatric patients with TBI on PICU. Very preliminary evidence suggests good tolerability of auditory stimuli, but efficacy of auditory stimuli to enhance delta waves remains unclear and requires further investigation. However, only low numbers of severe TBI patients could be enrolled in the study and, thus, future studies should consider an international multicentre approach.


Asunto(s)
Lesiones Traumáticas del Encéfalo , Niño , Humanos , Estimulación Acústica , Estudios de Factibilidad , Lesiones Traumáticas del Encéfalo/terapia , Electroencefalografía/métodos , Cuidados Críticos
2.
Sleep Med ; 109: 285-292, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-37499464

RESUMEN

OBJECTIVE: According to current practical guidelines, naps of the Mean Sleep Latency Test (MSLT) must be terminated 15 min after sleep onset, which requires ad hoc scoring. For clinical convenience, some sleep clinics use a simplified protocol with fixed nap lengths of 20min. Its diagnostic accuracy remains unknown. METHODS: A subset of MSLT naps of 56 narcolepsy type 1 (NT1), 98 Parkinson's disease (PD), 117 sleep disordered breathing (SDB), 22 insufficient sleep syndrome (ISS) patients, and 24 patients with idiopathic hypersomnia (IH), originally performed according to the simplified protocol, were retrospectively adjusted to standard protocol (nap termination 15min after sleep onset or after 20min when no sleep occurs). This was feasible in 60% of MSLT naps; in this subset, we compared sensitivity and specificity of both MSLT protocols for identification of patients with and without NT1. RESULTS: Sensitivity of classical MSLT criteria for NT1, i.e. mean sleep latency ≤8.0min and ≥2 sleep onset rapid eye movement periods (SOREMPs), did not differ between protocols (95%). Specificity, however, was slightly lower (88.1% vs. 89.7%) in the simplified nap termination protocol, with 3 SDB patients and 1 ISS patient having false-positive MSLT findings in the simplified but not in the standard protocol. CONCLUSIONS: The use of a simplified MSLT protocol with fixed nap duration had no impact on MSLT sensitivity for NT1, but the longer sleep periods in the simplified protocol increased the likelihood of REM sleep occurrence particularly in non-NT1 conditions, resulting in a slightly lower MSLT specificity compared to the standard protocol.


Asunto(s)
Trastornos de Somnolencia Excesiva , Narcolepsia , Síndromes de la Apnea del Sueño , Humanos , Estudios Retrospectivos , Polisomnografía , Narcolepsia/diagnóstico , Trastornos de Somnolencia Excesiva/diagnóstico , Sueño , Privación de Sueño , Síndromes de la Apnea del Sueño/diagnóstico
3.
J Neurosurg ; : 1-8, 2023 Nov 03.
Artículo en Inglés | MEDLINE | ID: mdl-37922562

RESUMEN

OBJECTIVE: Target depth, defined by the z-coordinate in the dorsoventral axis relative to the anterior commissure-posterior commissure axial plane of the MR-guided focused ultrasound (MRgFUS) lesion, is considered to be critical for tremor improvement and the occurrence of side effects such as gait impairment. However, although different z-coordinates are used in the literature, there are no comparative studies available with information on optimal lesion placement. This study aimed to compare two different MRgFUS lesion targets (z = +2 mm vs z = 0 mm) regarding efficacy and safety outcomes. METHODS: The authors conducted a retrospective analysis of 52 patients with pharmacoresistant tremor disorders who received unilateral MRgFUS thalamotomy in the ventral intermediate nucleus for the first time between 2017 and 2022 by one neurosurgeon, with two different z-coordinates, either z = +2 mm (+2-mm group; n = 17) or z = 0 mm (0-mm group; n = 35), but otherwise identical parameters. Standardized video-recorded assessments of efficacy (including the Washington Heights-Inwood Genetic Study of Essential Tremor scale) and safety (using a standardized grading system) outcomes at baseline and at 6 months posttreatment were reviewed and compared. Moreover, overall patient satisfaction was extracted as documented by the examiner at 6 months. RESULTS: Based on a multiple logistic regression analysis, the authors found that a more dorsal target with a z-coordinate of +2 mm as compared with 0 mm was associated with a higher incidence of any persistent side effect at 6 months (p = 0.02). Most consistently, sensory disturbances, although mild and nondisturbing in most cases, occurred more frequently in the +2-mm group (35% vs 11%, p = 0.007), while no significant differences were found for gait impairment (29% vs 35%) and arm ataxia (24% vs 11%). On the other hand, average tremor suppression was similar (63.6% vs 60.2%) between the groups. Here, higher efficacy was associated with a higher side effect burden in the 0-mm group but not in the +2-mm group. Despite the occurrence of side effects, general patient satisfaction was high (87% would undergo MRgFUS again) as most patients valued tremor suppression more. CONCLUSIONS: A more ventral MRgFUS target of z = 0 mm seems to be associated with a more favorable safety and a comparable efficacy profile as compared with a more dorsal target of z = +2 mm, but prospective studies are warranted.

4.
J Neurol Surg A Cent Eur Neurosurg ; 82(1): 18-26, 2021 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-33049794

RESUMEN

OBJECTIVES: While the efficacy of deep brain stimulation (DBS) to treat various neurological disorders is undisputed, the surgical methods differ widely and the importance of intraoperative microelectrode recording (MER) or macrostimulation (MS) remains controversially debated. The objective of this study is to evaluate the impact of MER and MS on intraoperative lead placement. PATIENTS AND METHODS: We included 101 patients who underwent awake bilateral implantation of electrodes in the subthalamic nucleus with MER and MS for Parkinson's disease from 2009 to 2017 in a retrospective observational study. We analyzed intraoperative motor outcomes between anatomically planned stimulation point (PSP) and definite stimulation point (DSP), lead adjustments and Unified Parkinson's Disease Rating Scale Item III (UPDRS-III), levodopa equivalent daily dose (LEDD), and adverse events (AE) after 6 months. RESULTS: We adjusted 65/202 leads in 47/101 patients. In adjusted leads, MS results improved significantly when comparing PSP and DSP (p < 0.001), resulting in a number needed to treat of 9.6. After DBS, UPDRS-III and LEDD improved significantly after 6 months in adjusted and nonadjusted patients (p < 0.001). In 87% of leads, the active contact at 6 months still covered the optimal stimulation point during surgery. In total, 15 AE occurred. CONCLUSION: MER and MS have a relevant impact on the intraoperative decision of final lead placement and prevent from a substantial rate of poor stimulation outcome. The optimal stimulation points during surgery and chronic stimulation strongly overlap. Follow-up UPDRS-III results, LEDD reductions, and DBS-related AE correspond well to previously published data.


Asunto(s)
Estimulación Encefálica Profunda/métodos , Monitorización Neurofisiológica Intraoperatoria/métodos , Levodopa/uso terapéutico , Enfermedad de Parkinson/terapia , Núcleo Subtalámico/cirugía , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Enfermedad de Parkinson/tratamiento farmacológico , Enfermedad de Parkinson/cirugía , Estudios Retrospectivos , Resultado del Tratamiento
5.
Sleep Med Rev ; 13(1): 9-22, 2009 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-18819824

RESUMEN

The hypothalamic hypocretin (orexin) system plays a crucial role in the regulation of sleep and wakefulness. The strongest evidence for this is the fact that the primary sleep disorder narcolepsy is caused by disrupted hypocretin signaling in humans as well as various animal models. There is a growing interest in the role of hypocretin defects not only in the pathophysiology of other sleep disorders, but also in neurological diseases with associated sleep symptomatology. In this paper we first review the current methods to measure the integrity of the hypocretin system in human patients. The most widely used technique entails the measurement of hypocretin-1 in lumbar cerebrospinal fluid. In addition, hypocretin levels can be measured in ventricular cerebrospinal fluid and brain tissue extract. Finally, in post-mortem hypothalamic material, the number of hypocretin neurons can be precisely quantified. In the second part of this paper we describe the various neurological disorders in which hypocretin defects have been reported. These include neurodegenerative, neuromuscular and immune-mediated diseases, as well as traumatic brain injury. We conclude with a discussion of the functional relevance of partial hypocretin defects, and the various pathophysiological mechanisms that can lead to such defects.


Asunto(s)
Péptidos y Proteínas de Señalización Intracelular/fisiología , Enfermedades del Sistema Nervioso/fisiopatología , Neuropéptidos/fisiología , Trastornos del Sueño-Vigilia/fisiopatología , Animales , Humanos , Hipotálamo/fisiopatología , Neuronas/fisiología , Orexinas
6.
Circulation ; 114(3): 237-41, 2006 Jul 18.
Artículo en Inglés | MEDLINE | ID: mdl-16831985

RESUMEN

BACKGROUND: We assessed the incidence of early recurrent ischemic stroke in stroke patients treated with intravenous tissue-type plasminogen activator (tPA) and the temporal pattern of its occurrence compared with symptomatic intracranial hemorrhage (ICH). METHODS AND RESULTS: Prospectively collected, population-based data for 341 consecutive acute stroke patients (62% men; mean age, 66 years) treated with tPA according to the National Institute of Neurological Disorders and Stroke study protocol at 8 medical centers in Switzerland (3 academic and 5 community) between January 2001 and November 2004 were retrospectively analyzed. The primary outcome measure was neurological deterioration > or = 4 points on the National Institutes of Health Stroke Scale occurring within 24 hours of tPA treatment and caused either by recurrent ischemic stroke (defined as the occurrence of new neurological symptoms suggesting involvement of initially unaffected vascular territories and evidence of corresponding ischemic lesions on cranial computed tomography scans, in the absence of ICH) or by ICH. Early recurrent ischemic stroke was diagnosed in 2 patients (0.59%; 95% confidence interval, 0.07% to 2.10%) and symptomatic ICH in 15 patients (4.40%; 95% confidence interval, 2.48% to 7.15%). Both recurrent ischemic strokes occurred during thrombolysis, whereas symptomatic ICHs occurred 2 to 22 hours after termination of tPA infusion. CONCLUSIONS: Recurrent ischemic stroke is a rare cause of early neurological deterioration in acute stroke patients undergoing intravenous thrombolysis, with a different temporal pattern compared with that of symptomatic ICH.


Asunto(s)
Fibrinolíticos/efectos adversos , Accidente Cerebrovascular/tratamiento farmacológico , Accidente Cerebrovascular/fisiopatología , Terapia Trombolítica/efectos adversos , Activador de Tejido Plasminógeno/efectos adversos , Anciano , Femenino , Humanos , Incidencia , Masculino , Selección de Paciente , Recurrencia , Estudios Retrospectivos , Factores de Tiempo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA