Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Bases de datos
Tipo de estudio
Tipo del documento
Asunto de la revista
Intervalo de año de publicación
1.
Langmuir ; 33(15): 3610-3623, 2017 04 18.
Artículo en Inglés | MEDLINE | ID: mdl-28296414

RESUMEN

Normal and friction forces between immobilized two-dimensional (2D) homogeneous non-close-packed colloidal arrays made of different particles are compared in aqueous media. Soft pH-responsive (microgels) and nonresponsive hard (silica) particles of different sizes were used to create the 2D arrays. The results show that the friction of soft responsive structured layers can be successfully modulated by varying the pH, with a friction coefficient varying by nearly 3 orders of magnitude (10-2 to 1). This important change in lubricating properties is mainly correlated with the particle swelling behavior, i.e., the friction coefficient decreasing exponentially with an increase in the swelling ratio regardless of the size, surface coverage, and degree of ionization of the particles. In addition, the robustly attached microgel particles were able to sustain high pressure (up to 200 atm) without significant surface damage. The 2D arrays of nonresponsive hard particles also gave rise to a very low friction coefficient (µ ≈ 10-3) under similar experimental conditions and could sustain a larger pressure without damage (≤600 atm). The low friction dissipation observed between the hard arrays resulted from a rolling mechanism. Even though rolling requires nonimmobilized particles on the substrates, the results show the importance of attaching a certain proportion of particles on the surfaces to reduce friction.

2.
Diagn Interv Imaging ; 102(10): 641-648, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-34099436

RESUMEN

PURPOSE: To evaluate the potential differences in non-target embolization and vessel microsphere filling of a reflux-control microcatheter (RCM) compared to a standard end-hole microcatheter (SEHM) in a swine model. MATERIALS AND METHODS: Radiopaque microspheres were injected with both RCM and SEHM (2.4-Fr and 2.7-Fr) in the kidneys of a preclinical swine model. Transarterial renal embolization procedures with RCM or SEHM were performed in both kidneys of 14 pigs. Renal arteries were selectively embolized with an automated injection protocol of radio-opaque microspheres. Ex-vivo X-ray microtomography images of the kidneys were utilized to evaluate the embolization by quantification of the deposition of injected microspheres in the target vs. the non-target area of injection. X-ray microtomography images were blindly analyzed by five interventional radiologists. The degree of vessel filling and the non-target embolization were quantified using a scale from 1 to 5 for each parameter. An analysis of variance was used to compare the paired scores. RESULTS: Total volumes of radio-opaque microspheres injected were similar for RCM (11.5±3.6 [SD] mL; range: 6-17mL) and SEHM (10.6±5.2 [SD] mL; range: 4-19mL) (P=0.38). The voxels enhanced ratio in the target (T) vs. non-target (NT) areas was greater with RCM (T=98.3% vs. NT=1.7%) than with SEHM (T=89% vs. NT=11%) but the difference was not significant (P=0.30). The total score blindly given by the five interventional radiologists was significantly different between RCM (12.3±2.1 [SD]; range: 6-15) and the standard catheter (11.3±2.5 [SD]; range: 4-15) (P=0.0073), with a significant decrease of non-target embolization for RCM (3.8±1.3 [SD]; range: 3.5-4.2) compared to SEHM (3.2±1.5 [SD]; range: 2.9-3.5) (P=0.014). CONCLUSION: In an animal model, RCM microcatheters reduce the risk of non-target embolization from 11% to 1.7%, increasing the delivery of microspheres of 98% to the target vessels, compared to SEHM microcatheters.


Asunto(s)
Embolización Terapéutica , Animales , Catéteres , Riñón , Microesferas , Arteria Renal/diagnóstico por imagen , Porcinos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA