Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 137
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
J Nucl Cardiol ; 30(3): 1133-1146, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-36460862

RESUMEN

BACKGROUND: Patient motion reduces the accuracy of PET myocardial blood flow (MBF) measurements. This study evaluated the effect of automatic motion correction on test-retest repeatability and inter-observer variability in a clinically relevant population. METHODS: Patients with known or suspected CAD underwent repeat rest 82Rb PET scans within minutes as part of their scheduled rest-stress perfusion study. Two trained observers evaluated the presence of heart motion in each scan. Global LV and per-vessel MBF were computed from the dynamic rest images before and after automatic motion correction. Test-retest and inter-observer variability were assessed using intra-class correlation and Bland-Altman analysis. RESULTS: 140 pairs of test-retest scans were included, with visual motion noted in 18%. Motion correction decreased the global MBF values by 3.5% (0.80 ± 0.24 vs 0.82 ± 0.25 mL⋅min-1⋅g-1; P < 0.001) suggesting that the blood input function was underestimated in cases with patient motion. Test-retest repeatability of global MBF improved by 9.7% (0.25 vs 0.28 mL⋅min-1⋅g-1; P < 0.001) and inter-observer repeatability was improved by 7.1% (0.073 vs 0.079 mL⋅min-1⋅g-1; P = 0.012). There was a marked impact on both test-retest repeatability as well as inter-observer repeatability in the LCX territory, with improvements of 16.5% (0.30 vs 0.36 mL⋅min-1⋅g-1; P < 0.0000) and 18.4% (0.13 vs 0.16 mL⋅min-1⋅g-1; P < 0.001), respectively. CONCLUSION: Automatic motion correction improved test-retest repeatability and reduced differences between observers.


Asunto(s)
Enfermedad de la Arteria Coronaria , Imagen de Perfusión Miocárdica , Humanos , Circulación Coronaria , Reproducibilidad de los Resultados , Tomografía de Emisión de Positrones/métodos , Radioisótopos de Rubidio , Imagen de Perfusión Miocárdica/métodos
2.
J Nucl Cardiol ; 30(6): 2477-2489, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-37258955

RESUMEN

BACKGROUND: 82Rb PET is commonly performed using the same injected activity in all patients, resulting in lower image quality in larger patients. This study compared 82Rb dosing with exponential vs proportional functions of body weight on the standardization of myocardial perfusion image (MPI) quality. METHODS: Two sequential cohorts of N = 60 patients were matched by patient weight. Rest and dipyridamole stress 82Rb PET was performed using 0.1 MBq·kg-2 exponential and 9 MBq·kg-1 proportional dosing. MPI scans were compared qualitatively with visual image quality scoring (IQS) and quantitatively using the myocardium-to-blood contrast-to-noise ratio (CNR) and blood background signal-to-noise ratio (SNR) as a function of body weight. RESULTS: Average (min-max) patient body weight was 81 ± 18 kg (46-137 kg). Proportional dosing resulted in decreasing CNR, SNR, and visual IQS with increasing body weight (P < 0.05). Exponential dosing eliminated the weight-dependent decreases in these image quality metrics that were observed in the proportional dosing group. CONCLUSION: 82Rb PET dosing as an exponential (squared) function of body weight produced consistent stress perfusion image quality over a wide range of patient weights. Dramatically lower doses can be used in lighter patients, with the equivalent population dose shifted toward the heavier patients to standardize diagnostic image quality.


Asunto(s)
Enfermedad de la Arteria Coronaria , Imagen de Perfusión Miocárdica , Humanos , Tomografía de Emisión de Positrones/métodos , Tomografía Computarizada por Rayos X , Dipiridamol , Radioisótopos de Rubidio , Peso Corporal , Imagen de Perfusión Miocárdica/métodos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen
3.
J Nucl Cardiol ; 29(2): 413-425, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-34341953

RESUMEN

BACKGROUND: In ischemic cardiomyopathy patients, cardiac sympathetic nervous system dysfunction is a predictor of sudden cardiac arrest (SCA). This study compared abnormal innervation and perfusion measured by [11C]meta-hydroxyephedrine (HED) vs [13N]ammonia (NH3), conventional uptake vs parametric tracer analysis, and their SCA risk discrimination. METHODS: This is a sub-study analysis of the prospective PAREPET trial, which followed ischemic cardiomyopathy patients with reduced left ventricular ejection fraction (LVEF ≤ 35%) for events of SCA. Using n = 174 paired dynamic HED and NH3 positron emission tomography (PET) scans, regional defect scores (%LV extent × severity) were calculated using HED and NH3 uptake, as well as HED distribution volume and NH3 myocardial blood flow by kinetic modeling. RESULTS: During 4.1 years follow-up, there were 27 SCA events. HED defects were larger than NH3, especially in the lowest tertile of perfusion abnormality (P < .001). Parametric defects were larger than their respective tracer uptake defects (P < .001). SCA risk discrimination was not significantly improved with parametric or uptake mismatch (AUC = 0.73 or 0.70) compared to HED uptake defect scores (AUC = 0.67). CONCLUSION: Quantification of HED distribution volume and NH3 myocardial blood flow produced larger defects than their respective measures of tracer uptake, but did not lead to improved SCA risk stratification vs HED uptake alone.


Asunto(s)
Cardiomiopatías , Isquemia Miocárdica , Amoníaco , Cardiomiopatías/diagnóstico por imagen , Muerte Súbita Cardíaca , Efedrina/análogos & derivados , Corazón/inervación , Humanos , Cinética , Isquemia Miocárdica/diagnóstico por imagen , Tomografía de Emisión de Positrones , Estudios Prospectivos , Medición de Riesgo , Volumen Sistólico , Sistema Nervioso Simpático , Función Ventricular Izquierda
4.
J Nucl Cardiol ; 29(6): 3057-3068, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-34820771

RESUMEN

AIMS: This study aimed to evaluate markers of systemic as well as imaging markers of inflammation in the ascending aorta, bone marrow, and spleen measured by 18F-FDG PET/CT, in HIV+ patients at baseline and following therapy with rosuvastatin. METHODS AND RESULTS: Of the 35 HIV+ patients enrolled, 17 were randomized to treatment with 10 mg/day rosuvastatin and 18 to usual care for 6 months. An HIV- control cohort was selected for baseline comparison of serum inflammatory markers and monocyte markers of inflammation. 18F-FDG-PET/CT imaging of bone marrow, spleen, and thoracic aorta was performed in the HIV+ cohort at baseline and 6 months. While CD14++CD16- and CCR2 expressions were reduced, serum levels of IL-7, IL-8, and MCP-1 were elevated in the HIV+ population compared to the controls. There was a significant drop in FDG uptake in the bone marrow (TBRmax), spleen (SUVmax) and thoracic aortic (TBRmax) in the statin-treated group compared to the control group (bone marrow: - 10.3 ± 16.9% versus 5.0 ± 18.9%, p = .0262; spleen: - 9.8 ± 20.3% versus 11.3 ± 28.8%, p = .0497; thoracic aorta: - 19.1 ± 24.2% versus 4.3 ± 15.4%, p = .003). CONCLUSIONS: HIV+ patients had significantly markers of systemic inflammation including monocyte activation. Treatment with low-dose rosuvastatin in the HIV+ cohort significantly reduced bone marrow, spleen and thoracic aortic FDG uptake.


Asunto(s)
Fluorodesoxiglucosa F18 , Infecciones por VIH , Humanos , Rosuvastatina Cálcica/farmacología , Rosuvastatina Cálcica/uso terapéutico , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Proyectos Piloto , Infecciones por VIH/complicaciones , Infecciones por VIH/diagnóstico por imagen , Infecciones por VIH/tratamiento farmacológico , Inflamación/diagnóstico por imagen , Inflamación/tratamiento farmacológico , Biomarcadores , Antiinflamatorios/uso terapéutico , Radiofármacos
5.
J Nucl Cardiol ; 29(6): 2824-2836, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-34993894

RESUMEN

BACKGROUND: Alterations in atrial metabolism may play a role in the perpetuation of atrial fibrillation (AF). This study sought to compare 18F-fluorodeoxyglucose (FDG) uptake on PET, in patients with LV dysfunction versus those without AF. METHODS: Seventy-two patients who underwent myocardial viability assessment were evaluated. AF patients (36) had persistent or permanent AF based on history and ECG. Patients without AF (36) were matched to AF patients based on sex, diabetes, age, and LVEF. Maximum and mean FDG Standard Uptake Values (SUV) in the left atrial (LA) wall and right atrial (RA) wall were measured. Tissue-to-blood ratios (TBR) were calculated as atrial wall to blood-pool activity. Atrial volumes were measured by echocardiography. RESULTS: Maximum and mean FDG SUV and TBRs were significantly increased in the RA (but not the LA) of patients with AF compared to those without (P < 0.01). When accounting for changes in atrial volume, the presence of AF remained a significant predictor of higher RAMAX, but not RAMEAN FDG uptake. CONCLUSION: In patients with LV dysfunction from ischemic cardiomyopathy, LA and RA glucose metabolism are differentially altered in those with persistent atrial fibrillation. Further investigations should elucidate the temporal relationship between AF and glucose metabolic changes, as a potential target for therapy.


Asunto(s)
Fibrilación Atrial , Disfunción Ventricular Izquierda , Humanos , Fibrilación Atrial/metabolismo , Fluorodesoxiglucosa F18/metabolismo , Atrios Cardíacos/diagnóstico por imagen , Atrios Cardíacos/metabolismo , Miocardio/metabolismo
6.
J Nucl Cardiol ; 28(3): 835-850, 2021 06.
Artículo en Inglés | MEDLINE | ID: mdl-33389638

RESUMEN

BACKGROUND: Myocardial flow reserve (MFR) measurement provides incremental diagnostic and prognostic information. The objective of the current study was to investigate the application of a simplified model for the estimation of MFR using only the stress/rest myocardial activity ratio (MAR) in patients undergoing rest-stress cardiac PET MPI. METHODS AND RESULTS: Rest and dipyridamole stress dynamic PET imaging was performed in consecutive patients using 82Rb or 13NH3 (n = 250 each). Reference standard MFR was quantified using a standard one-tissue compartment model. Stress/rest myocardial activity ratio (MAR) was calculated using the LV-mean activity from 2 to 6 minutes post-injection. Simplified estimates of MFR (MFREST) were then calculated using an inverse power function. For 13NH3, there was good correlation between MFR and MFREST values (R = 0.63), with similar results for 82Rb (R = 0.73). There was no bias in the MFREST values with either tracer. The overall diagnostic performance of MFREST for detection of MFR < 2 was good with ROC area under the curve (AUC) = 83.2 ± 1.2% for 13NH3 and AUC = 90.4 ± 0.7% for 82Rb. CONCLUSION: MFR was estimated with good accuracy using 82Rb and 13NH3 with a simplified method that relies only on stress/rest activity ratios. This novel approach does not require dynamic imaging or tracer kinetic modeling. It may be useful for routine quality assurance of PET MFR measurements, or in scanners where full dynamic imaging and tracer kinetic modeling is not feasible for technical or logistical reasons.


Asunto(s)
Amoníaco , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Reserva del Flujo Fraccional Miocárdico , Imagen de Perfusión Miocárdica/métodos , Radioisótopos de Nitrógeno , Tomografía de Emisión de Positrones/métodos , Radioisótopos de Rubidio , Anciano , Área Bajo la Curva , Prueba de Esfuerzo , Femenino , Hemodinámica , Humanos , Procesamiento de Imagen Asistido por Computador , Imagenología Tridimensional , Cinética , Masculino , Persona de Mediana Edad , Tomografía Computarizada por Tomografía de Emisión de Positrones , Presión , Pronóstico , Curva ROC , Reproducibilidad de los Resultados , Estudios Retrospectivos , Estrés Mecánico , Tomografía Computarizada de Emisión de Fotón Único
7.
J Nucl Cardiol ; 28(5): 2286-2298, 2021 10.
Artículo en Inglés | MEDLINE | ID: mdl-31993956

RESUMEN

BACKGROUND: We previously demonstrated high diagnostic accuracy of Rubidium-82 positron emission tomography (PET) myocardial blood flow (MBF) quantification for CAV. The purpose of this study was to validate multiparametric PET detection of CAV by combined rate-pressure-product-corrected myocardial flow reserve (cMFR), stress MBF, and coronary vascular resistance (CVR) assessment. METHODS AND RESULTS: Diagnostic CAV cut-offs of cMFR < 2.9, stress MBF < 2.3, CVR > 55 determined in a previous study (derivation) were assessed in heart transplant recipients referred for coronary angiography and intravascular ultrasound (IVUS) (validation). CAV was defined as International Society of Heart and Lung Transplantation CAV1-3 on angiography; and maximal intimal thickness ≥ 0.5 mm on IVUS. Eighty patients (derivation n = 40, validation n = 40) were included: 80% male, mean age 54±14 years, 4.5±5.6 years post transplant. The prevalence of CAV was 44% on angiography and 78% on IVUS. Combined PET cMFR < 2.9, stress MBF < 2.3, CVR > 55 CAV assessment yielded high 88% (specificity 75%) and 83% (specificity 40%) sensitivity for ≥ 1 abnormal parameter and high 88% (sensitivity 59%) and 90% (sensitivity 43%) specificity for 3 abnormal parameters, in the derivation and validation cohorts, respectively. CONCLUSION: We validate the diagnostic accuracy of multiparametric PET flow quantification by cMFR, stress MBF, and CVR for CAV.


Asunto(s)
Reserva del Flujo Fraccional Miocárdico/fisiología , Cardiopatías/diagnóstico por imagen , Cardiopatías/fisiopatología , Trasplante de Corazón/efectos adversos , Imagen de Perfusión Miocárdica , Tomografía de Emisión de Positrones , Adulto , Anciano , Algoritmos , Estudios de Cohortes , Angiografía Coronaria , Femenino , Cardiopatías/etiología , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Radioisótopos de Rubidio , Ultrasonografía Intervencional , Resistencia Vascular/fisiología
8.
J Nucl Cardiol ; 28(3): 1105-1116, 2021 06.
Artículo en Inglés | MEDLINE | ID: mdl-33521873

RESUMEN

BACKGROUND: Positron emission tomography (PET) myocardial perfusion imaging (MPI) with the novel radiopharmaceutical Fluorine-18 Flurpiridaz has been shown in Phase 1, 2, and first Phase 3 clinical studies to be safe and effective in diagnosing coronary artery disease (CAD). We describe the methodology of the second FDA-mandated phase 3 prospective, open-label, international, multi-center trial of F-18 Flurpiridaz PET MPI. METHODS: The primary study end point is to assess the diagnostic efficacy of F-18 Flurpiridaz PET MPI in the detection of significant CAD [≥ 50% by quantitative invasive coronary angiography (ICA)] in patients with suspected CAD. The secondary endpoints are to evaluate the diagnostic efficacy of F-18 Flurpiridaz PET MPI compared to Tc-99 m-labeled SPECT MPI in the detection of CAD in all patients and in the following subgroups: (1) females; (2) patients with body mass index ≥ 30 kg/m2; and (3) diabetic patients. This trial's design differs from the first phase 3 trial in that (1) comparison to SPECT is now a secondary end point; (2) patients with known CAD are excluded; and (3) both SPECT and PET MPI are performed before ICA. CONCLUSIONS: This second phase 3 study will provide additional evidence on the diagnostic efficacy of F-18 Flurpiridaz PET MPI in the detection of significant CAD. TRIAL REGISTRATION NUMBER: NCT03354273.


Asunto(s)
Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Imagen de Perfusión Miocárdica , Tomografía de Emisión de Positrones , Piridazinas , Ensayos Clínicos Fase III como Asunto , Humanos , Estudios Multicéntricos como Asunto , Proyectos de Investigación
9.
Am Heart J ; 220: 246-252, 2020 02.
Artículo en Inglés | MEDLINE | ID: mdl-31911261

RESUMEN

Approximately 5% of patients with sarcoidosis have clinically manifest cardiac involvement. Clinical features of Cardiac Sarcoidosis are dependent on the location, extent, and activity of the disease. First line therapy is usually with prednisone and this is recommended based on clinician experience, expert opinion and small observational cohorts. There are no published clinical trials in cardiac sarcoidosis and multiple experts in the field have called for randomized clinical trials to answer important patient care questions. Corticosteroid are associated with multiple adverse effects including hypertension, diabetes, weight gain, osteoporosis, and increased risk of infections. In contrast Methotrexate is generally well tolerated and is increasingly used in other forms of sarcoidosis. OBJECTIVES: The Cardiac Sarcoidosis Multi-Center Randomized Controlled Trial (CHASM CS-RCT; NCT03593759) is a multicenter randomized controlled trial designed to evaluate the optimal initial treatment strategy for patients with active cardiac sarcoidosis. We hypothesize that (1) a low dose prednisone/methotrexate combination will have non-inferior efficacy to standard dose prednisone and that (2) the low dose prednisone/ methotrexate combination will result in significantly better quality of life than standard dose prednisone, as a result of reduced burden of side effects. METHODS/DESIGN: Eligible study subjects will have active clinically manifest cardiac sarcoidosis presenting with one or more of the following clinical findings: advanced conduction system disease, significant sinus node dysfunction, non-sustained or sustained ventricular arrhythmia, left ventricular dysfunction or right ventricular dysfunction. Subjects will be randomized in a 1:1 ratio to prednisone 0.5 mg/kg/day for 6 months (maximum dose 30 mg daily) OR to prednisone 20 mg daily for 1 month, then 10 mg daily for 1 month, then 5 mg daily for one month then stop AND methotrexate 15-20 mg once weekly for 6 months. The primary endpoint is summed perfusion rest score on 6-month PET (blinded core-lab review). The summed perfusion rest score is measure of myocardial fibrosis/scar. The design is non-inferiority with a sample size of 97 per group. DISCUSSION: Given the multiorgan system potential adverse side effects of prednisone, proving noninferiority of an alternate regimen would be sufficient to make the alternative compare favorably to standard dose steroids. This is the first ever clinical trial in cardiac sarcoidosis and thus in addition to the listed goals of the trial, we will also establish a multi-center, multinational cardiac sarcoidosis clinical trials network. Such a collaborative infrastructure will enable a new era of high quality data to guide physicians when treating cardiac sarcoidosis patients.


Asunto(s)
Cardiomiopatías/tratamiento farmacológico , Glucocorticoides/administración & dosificación , Metotrexato/administración & dosificación , Prednisona/administración & dosificación , Ensayos Clínicos Controlados Aleatorios como Asunto , Sarcoidosis/tratamiento farmacológico , Cardiomiopatías/complicaciones , Esquema de Medicación , Quimioterapia Combinada , Estudios de Equivalencia como Asunto , Glucocorticoides/efectos adversos , Humanos , Estudios Multicéntricos como Asunto , Prednisona/efectos adversos , Estudios Prospectivos , Calidad de Vida , Proyectos de Investigación , Sarcoidosis/complicaciones
10.
Eur J Nucl Med Mol Imaging ; 47(7): 1722-1735, 2020 07.
Artículo en Inglés | MEDLINE | ID: mdl-31814069

RESUMEN

PURPOSE: Cardiac sympathetic nervous system (SNS) dysfunction is associated with poor prognosis in chronic heart failure patients. This study characterized the reproducibility and repeatability of [11C]meta-hydroxyephedrine (HED) positron emission tomography (PET) quantification of cardiac SNS innervation, regional denervation, and myocardial blood flow (MBF). METHODS: Dynamic HED PET-CT scans were performed 47 ± 22 days apart in 20 patients with stable heart failure and reduced ejection fraction. Three observers, blinded to clinical data, used FlowQuant® to evaluate the test-retest repeatability and inter- and intra-observer reproducibility of HED tracer uptake and clearance rates to measure global (LV-mean) retention index (RI), volume of distribution (VT), and MBF. Values were also compared with and without regional partial-volume correction. Regional denervation was quantified as %LV defect size of values < 75% of the LV-maximum. Test-retest repeatability and observer reproducibility were evaluated using intra-class-correlation (ICC) and Bland-Altman coefficient of repeatability (NPC). RESULTS: Intra- and inter-observer correlations of both VT and RI were excellent (ICC = 0.93-0.99). Observer reproducibility (NPC = 3-13%) was lower than test-retest repeatability (NPC = 12-61%). Both regional (%LV defect size) and global (LV-mean) measures of sympathetic innervation were more repeatable using the simple RI model compared to VT (NPC = 12% vs. 19% and 30% vs. 54%). Using either model, quantification of regional denervation (defect size) was consistently more reliable than the global LV-mean values of RI or VT. Regional partial-volume correction degraded repeatability of both the global and regional VT measures by 2-12%. Test-retest repeatability of MBF estimation was relatively poor (NPC = 30-61%) compared with the RI. CONCLUSIONS: Quantitative measures of global and regional SNS innervation were most repeatable using the simple RI method of analysis compared with the more complex VT. Observer variability was significantly lower than the test-retest repeatability using a highly automated analysis program. These results support the use of the simple RI method for reliable analysis of HED PET images in clinical research studies for future evaluation of new therapies and for risk stratification in patients with heart failure.


Asunto(s)
Efedrina/análogos & derivados , Insuficiencia Cardíaca , Corazón , Tomografía Computarizada por Tomografía de Emisión de Positrones , Sistema Nervioso Simpático , Anciano , Radioisótopos de Carbono , Enfermedad Crónica , Desnervación , Femenino , Corazón/diagnóstico por imagen , Corazón/inervación , Insuficiencia Cardíaca/diagnóstico por imagen , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Sistema Nervioso Simpático/diagnóstico por imagen
11.
J Nucl Cardiol ; 27(5): 1728-1738, 2020 10.
Artículo en Inglés | MEDLINE | ID: mdl-32436115

RESUMEN

INTRODUCTION: Strontium-82/Rubidium-82 (82Sr/82Rb) generators are used widely for positron emission tomography (PET) imaging of myocardial perfusion. In this study, the 82Rb isotope yield and production efficiency of two FDA-approved 82Sr/82Rb generators were compared. METHODS: N = 515 sequential daily quality assurance (QA) reports from 9 CardioGen-82® and 9 RUBY-FILL® generators were reviewed over a period of 2 years. A series of test elutions was performed at different flow-rates on the RUBY-FILL® system to determine an empirical correction-factor used to convert CardioGen-82® daily QA values of 82Rb activity (dose-calibrator 'maximum' of 50 mL elution at 50 mL·min-1) to RUBY-FILL® equivalent values (integrated 'total' of 35 mL elution at 20 mL·min-1). The generator yield (82Rb) and production efficiency (82Rb yield/82Sr parent activity) were measured and compared after this conversion to a common scale. RESULTS: At the start of clinical use, the system reported 82Rb activity from daily QA was lower for CardioGen-82® vs RUBY-FILL® (2.3 ± 0.2 vs 3.0 ± 0.2 GBq, P < 0.001) despite having similar 82Sr activity. Dose-calibrator 'maximum' (CardioGen-82®) values were found to under-estimate the integrated 'total' (RUBY-FILL®) activity by ~ 24% at 50 mL·min-1. When these data were used to convert the CardioGen-82 values to a common measurement scale (integrated total activity) the CardioGen-82® efficiency remained slightly lower than the RUBY-FILL® system on average (88 ± 4% vs 95 ± 4%, P < 0.001). The efficiency of 82Rb production improved for both systems over the respective periods of clinical use. CONCLUSIONS: 82Rb generator yield was significantly under-estimated using the CardioGen-82® vs RUBY-FILL® daily QA procedure. When generator yield was expressed as the integrated total activity for both systems, the estimated 82Rb production efficiency of the CardioGen-82® system was ~ 7% lower than RUBY-FILL® over the full period of clinical use.


Asunto(s)
Cardiopatías/diagnóstico por imagen , Imagen de Perfusión Miocárdica/instrumentación , Tomografía de Emisión de Positrones/instrumentación , Generadores de Radionúclidos/instrumentación , Radioisótopos de Rubidio , Radioisótopos de Estroncio , Humanos , Garantía de la Calidad de Atención de Salud , Estudios Retrospectivos
12.
J Nucl Cardiol ; 27(2): 702, 2020 04.
Artículo en Inglés | MEDLINE | ID: mdl-31898001

RESUMEN

At time of initial publication, the USAN Council had assigned the generic name for LMI1195 as Flurobenguan. However, the Council has since changed and finalized this compound name as Flubrobenguane which is recommended as the generic name to be used in the future.

13.
J Nucl Cardiol ; 26(6): 1869-1874, 2019 12.
Artículo en Inglés | MEDLINE | ID: mdl-29589206

RESUMEN

INTRODUCTION: Rubidium-82 (82Rb) PET is used widely for myocardial perfusion imaging. The purpose of this study was to investigate if an additional saline-push following the 82Rb elution improves PET image quality. METHODS: 82Rb PET scans were acquired with and without 26 mL saline-push in six patients as part of a clinical quality improvement program. Dynamic images were analyzed to measure the total activity delivered to the superior vena cava (SVC) and retained in the left ventricle (LV) myocardium. Tracer uptake images were used to measure blood background coefficient-of-variation (COV), myocardium-to-blood signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) to assess image quality. RESULTS: Similar eluted activity was measured with/without the saline-push (830 vs 795 MBq; P = 0.24). The activity delivered to the heart and retained in the myocardium was consistently increased more than twofold (SVC: + 114% and LV: + 104%; P < 0.001) with the saline-push. Image quality was improved in all patients, with lower background noise (COV: - 19%), higher SNR (+ 24%) and CNR (+ 27%) (all P ≤ 0.01). CONCLUSIONS: The saline-push used to flush 82Rb activity out of the infuser tubing, patient injection and intravenous access lines consistently increased the activity delivered to the heart by twofold. This technique is recommended to maximize image quality with 82Rb PET.


Asunto(s)
Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Imagen de Perfusión Miocárdica/métodos , Tomografía de Emisión de Positrones/métodos , Radioisótopos de Rubidio/administración & dosificación , Solución Salina/administración & dosificación , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Volumen Sistólico
15.
J Nucl Cardiol ; 26(6): 1888-1897, 2019 12.
Artículo en Inglés | MEDLINE | ID: mdl-29651739

RESUMEN

BACKGROUND: Cardiac magnetic resonance perfusion studies with adenosine stress have shown that splenic response can identify patients with inadequate pharmacologic stress. We investigate the incremental prognostic impact of splenic response ratio (SRR) in patients with normal Rubidium (Rb)-82 PET myocardial perfusion imaging (MPI). METHODS: Consecutive patients undergoing dipyridamole Rb-82 PET MPI for the evaluation of coronary artery disease were screened. Spleen and liver Rb-82 activity was measured and the SRR was calculated: SRR = (Spleen stress/Liver stress)/(Spleen rest/Liver rest). Major adverse cardiac events (MACE) were determined at 1 year of follow-up in patients with normal summed stress score and normal summed difference score. RESULTS: Of the 839 patients screened, the spleen was visualized in 703 (84%) of scans. There was significantly higher MACE observed in splenic non-responders vs splenic responders in both the normal SSS (7.8% vs 2.9%, P = .027) and the normal SDS groups (7.4% vs 2.2%, P = .014). In multivariate analysis in patients with normal SDS, splenic response was a significant, independent predictor of MACE (HR 2.97, 95% CI 1.10 to 8.04, P = .033). CONCLUSIONS: SRR is a novel imaging metric to identify patients with sub-maximal vasodilator stress and an incremental prognostic marker in patients with normal SDS and SSS (Clinical Trial Registration: https://clinicaltrials.gov/ct2/show/NCT01128023).


Asunto(s)
Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Dipiridamol/farmacología , Imagen de Perfusión Miocárdica , Tomografía de Emisión de Positrones , Bazo/diagnóstico por imagen , Anciano , Reacciones Falso Negativas , Femenino , Humanos , Estimación de Kaplan-Meier , Hígado/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Análisis Multivariante , Pronóstico , Modelos de Riesgos Proporcionales , Radioisótopos de Rubidio
16.
Europace ; 21(5): 708-715, 2019 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-30535367

RESUMEN

AIMS: Electrical cardioversion is commonly performed to restore sinus rhythm in patients with atrial fibrillation (AF), but it is unsuccessful in 10-12% of attempts. We sought to evaluate the effectiveness and safety of a novel cardioversion protocol for this arrhythmia. METHODS AND RESULTS: Consecutive elective cardioversion attempts for AF between October 2012 and July 2017 at a tertiary cardiovascular centre before (Phase I) and after (Phase II) implementing the Ottawa AF cardioversion protocol (OAFCP) as an institutional initiative in July 2015 were evaluated. The primary outcome was cardioversion success, defined as ≥2 consecutive sinus beats or atrial-paced beats in patients with implanted cardiac devices. Secondary outcomes were first shock success, sustained success (sinus or atrial-paced rhythm on 12-lead electrocardiogram prior to discharge from hospital), and procedural complications. Cardioversion was successful in 459/500 (91.8%) in Phase I compared with 386/389 (99.2%) in Phase II (P < 0.001). This improvement persisted after adjusting for age, body mass index, amiodarone use, and transthoracic impedance using modified Poisson regression [adjusted relative risk 1.08, 95% confidence interval (CI) 1.05-1.11; P < 0.001] and when analysed as an interrupted time series (change in level +9.5%, 95% CI 6.8-12.1%; P < 0.001). The OAFCP was also associated with greater first shock success (88.4% vs. 79.2%; P < 0.001) and sustained success (91.6% vs 84.7%; P=0.002). No serious complications occurred. CONCLUSION: Implementing the OAFCP was associated with a 7.4% absolute increase in cardioversion success and increases in first shock and sustained success without serious procedural complications. Its use could safely improve cardioversion success in patients with AF. CLINICAL TRIAL NUMBER: www.clinicaltrials.gov ID: NCT02192957.


Asunto(s)
Fibrilación Atrial , Protocolos Clínicos/normas , Cardioversión Eléctrica , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/terapia , Cardioversión Eléctrica/efectos adversos , Cardioversión Eléctrica/métodos , Electrocardiografía/métodos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Evaluación de Procesos y Resultados en Atención de Salud , Mejoramiento de la Calidad , Resultado del Tratamiento
17.
J Nucl Cardiol ; 25(3): 929-941, 2018 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-27804067

RESUMEN

OBJECTIVES: Quantification of myocardial blood flow (MBF) and stress/rest flow reserve is used increasingly to diagnose multi-vessel coronary artery disease and micro-vascular disease with PET imaging. However, variability in the measurements may limit physician confidence to direct revascularization therapies based on specific threshold values. This study evaluated the effects of rubidium-82 (82Rb) tracer injection profile using a constant-activity-rate (CA) vs a constant-flow-rate (CF) infusion to improve test-retest repeatability of MBF measurements. METHOD: 22 participants underwent single-session 82Rb dynamic PET imaging during rest and dipyridamole stress using one of 2 test-retest infusion protocols: CA-CA (n = 12) or CA-CF (n = 10). MBF was quantified using a single-tissue-compartment model (1TCM) and a simplified retention model (SRM). Non-parametric test-retest repeatability coefficients (RPCnp) were compared between groups. Myocardium-to-blood contrast and signal-to-noise ratios of the late uptake images (2 to 6 minutes) were also compared to evaluate standard myocardial perfusion image (MPI) quality. RESULTS: MBF values in the CA-CA group were more repeatable (smaller RPCnp) than the CA-CF group using the 1TCM at rest alone, rest and stress combined, and stress/rest reserve (21% vs 36%, 16% vs 19%, and 20% vs 27%, P < 0.05, respectively), and using the SRM at Rest and Stress alone, Rest and Stress combined, and stress/rest reserve (21% vs 38%, 15% vs 25%, 22% vs 38%, and 23% vs 49%, P < 0.05, respectively). In terms of image quality, myocardium-to-blood contrast and signal-to-noise ratios were not significantly different between groups. CONCLUSIONS: Constant-activity-rate 'square-wave' infusion of 82Rb produces more repeatable tracer injection profiles and decreases the test-retest variability of MBF measurements, when compared to a constant-flow-rate 'bolus' administration of 82Rb, especially with SRM, and without compromising standard MPI quality.


Asunto(s)
Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Imagen de Perfusión Miocárdica/métodos , Tomografía de Emisión de Positrones/métodos , Radiofármacos/administración & dosificación , Radioisótopos de Rubidio/administración & dosificación , Anciano , Estudios de Cohortes , Enfermedad de la Arteria Coronaria/fisiopatología , Circulación Coronaria , Dipiridamol , Prueba de Esfuerzo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Vasodilatadores
18.
J Nucl Cardiol ; 25(6): 1912-1925, 2018 12.
Artículo en Inglés | MEDLINE | ID: mdl-29453603

RESUMEN

BACKGROUND: Non-invasive approaches to investigate myocardial efficiency can help track the progression of heart failure (HF). This study evaluates the repeatability and reproducibility of 11C-acetate positron emission tomography (PET) imaging of oxidative metabolism. METHODS AND RESULTS: Dynamic 11C-acetate PET scans were performed at baseline and followup (47 ± 22 days apart) in 20 patients with stable HF with reduced ejection fraction. Two observers blinded to patients' clinical data used FlowQuant® to evaluate test-retest repeatability, as well as intra- and inter-observer reproducibility of 11C-acetate tracer uptake and clearance rates, for the measurement of myocardial oxygen consumption (MVO2), myocardial external efficiency (MEE), work metabolic index (WMI), and myocardial blood flow. Reproducibility and repeatability were evaluated using intra-class-correlation (ICC) and Bland-Altman coefficient-of-repeatability (CR). Test-retest correlations and repeatability were better for MEE and WMI compared to MVO2. All intra- and inter-observer correlations were excellent (ICC = 0.95-0.99) and the reproducibility values (CR = 3%-6%) were significantly lower than the test-retest repeatability values (22%-54%, P < 0.001). Repeatability was improved for all parameters using a newer PET-computed tomography (CT) scanner compared to older PET-only instrumentation. CONCLUSION: 11C-acetate PET measurements of WMI and MEE exhibited excellent test-retest repeatability and operator reproducibility. Newer PET-CT scanners may be preferred for longitudinal tracking of cardiac efficiency.


Asunto(s)
Circulación Coronaria , Miocardio/metabolismo , Tomografía de Emisión de Positrones/métodos , Acetatos , Anciano , Radioisótopos de Carbono , Femenino , Humanos , Masculino , Persona de Mediana Edad , Oxidación-Reducción , Consumo de Oxígeno , Reproducibilidad de los Resultados
20.
Eur J Nucl Med Mol Imaging ; 43(2): 259-269, 2016 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-26359191

RESUMEN

PURPOSE: Cardiac sarcoidosis (CS) is a cause of conduction system disease (CSD). (18)F-Fluorodeoxyglucose-positron emission tomography (FDG PET) and cardiac magnetic resonance (CMR) are used for detection of CS. The relative diagnostic value of these has not been well studied. The aim was to compare these imaging modalities in this population. METHODS: We recruited steroid-naive patients with newly diagnosed CSD due to CS. All CS patients underwent both imaging studies within 12 weeks of each other. Patients were classified into two groups: group A with chronic mild CSD (right bundle branch block and/or axis deviation), and group B with new-onset atrioventricular block (AVB, Mobitz type II or third-degree AVB). RESULTS: Thirty patients were included. Positive findings on both imaging studies were seen in 72 % of patients (13/18) in group A and in 58 % of patients (7/12) in group B. The remainder (28 %) of the patients in group A were positive only on CMR. Of the patients in group B, 8 % were positive only on CMR and 33 % were positive only on FDG PET. Patients in group A were more likely to be positive only on CMR, and patients in group B were more likely to be positive only on FDG PET (p = 0.02). Patients in group B positive only on FDG PET underwent CMR earlier relative to their symptomatology than patients positive only on CMR (median 7.0, IQR 1.5 - 34.3, vs. 72.0, IQR 25.0 - 79.5 days; p = 0.03). CONCLUSION: The number of positive FDG PET and CMR studies was different in patients with CSD depending on their clinical presentation. This study demonstrated that CMR can adequately detect cardiac involvement associated with chronic mild CSD. In patients presenting with new-onset AVB and a negative CMR study, FDG PET may be useful for detecting cardiac involvement due to CS.


Asunto(s)
Cardiomiopatías/diagnóstico por imagen , Sistema de Conducción Cardíaco/diagnóstico por imagen , Imagen por Resonancia Magnética , Imagen Multimodal , Tomografía de Emisión de Positrones , Sarcoidosis/diagnóstico por imagen , Tomografía Computarizada por Rayos X , Corticoesteroides/administración & dosificación , Adulto , Anciano , Cardiomiopatías/patología , Femenino , Fluorodesoxiglucosa F18 , Sistema de Conducción Cardíaco/patología , Humanos , Masculino , Persona de Mediana Edad , Radiofármacos , Sarcoidosis/patología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA