Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Catheter Cardiovasc Interv ; 90(6): 917-925, 2017 Nov 15.
Artículo en Inglés | MEDLINE | ID: mdl-28296167

RESUMEN

OBJECTIVE: We propose a novel technique called pressure-bounded coronary flow reserve (pb-CFR) and demonstrate its application to the randomized DEFER trial. BACKGROUND: Intracoronary flow reserve assessment remains underutilized relative to pressure measurements partly due to less robust tools. METHODS: While rest and hyperemic intracoronary pressure measurements cannot quantify CFR exactly, they do provide upper and lower bounds. We validated pb-CFR invasively against traditional CFR, then applied it to high fractional flow reserve (FFR ≥ 0.75) lesions in DEFER randomized to revascularization or medical therapy. RESULTS: pb-CFR showed an 84.4% accuracy to predict invasive CFR < 2 or CFR ≥ 2 in 107 lesions. In its proof of concept application to DEFER lesions with FFR ≥ 0.75, the 28 with pb-CFR < 2 compared to 28 with pb-CFR ≥ 2 had a non-significant reduction in freedom from angina (61% vs. 71% at 5 years, P = 0.57) and a non-significantly higher rate of major adverse cardiac events (MACE, 25% vs. 15%, P = 0.34). Lesions with FFR ≥ 0.75 but pb-CFR < 2 showed no difference in freedom from angina (61% vs. 50%, P = 0.54) or MACE (25% vs. 38%, P = 0.27) between the 28 randomized to medical therapy and the 16 randomized to revascularization. CONCLUSIONS: pb-CFR offers a new method for studying FFR/CFR discordances using regular pressure wire measurements. As an example application, DEFER suggested that low pb-CFR with high FFR may be a risk marker for more angina and worse outcomes, but that this risk cannot be modified by revascularization. © 2017 Wiley Periodicals, Inc.


Asunto(s)
Presión Arterial/fisiología , Velocidad del Flujo Sanguíneo/fisiología , Enfermedad de la Arteria Coronaria/fisiopatología , Vasos Coronarios/fisiopatología , Reserva del Flujo Fraccional Miocárdico/fisiología , Ensayos Clínicos Controlados Aleatorios como Asunto/métodos , Animales , Humanos
2.
Eur Heart J ; 36(45): 3182-8, 2015 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-26400825

RESUMEN

AIMS: Stenting an angiographically intermediate but functionally non-significant stenosis is controversial. Nevertheless, it has been questioned if deferral of a functionally non-significant lesion on the basis of fractional flow reserve (FFR) measurement, is safe, especially on the long term. Five-year follow-up of the DEFER trial showed that outcome after deferral of percutaneous coronary intervention (PCI) of an intermediate coronary stenosis based on FFR ≥ 0.75 is excellent and was not improved by stenting. The aim of this study was to investigate the validity of this position on the very long term. METHODS AND RESULTS: In 325 patients scheduled for PCI of an intermediate stenosis, FFR was measured just before the planned intervention. If FFR was ≥0.75, patients were randomly assigned to deferral (Defer group; n = 91) or performance (Perform group; n = 90) of PCI. If FFR was <0.75, PCI was performed as planned (Reference group; n = 144). Clinical follow-up was 15 years. There were no differences in baseline clinical characteristics between the randomized groups. Complete 15-year follow-up was obtained in 92% of patients. After 15 years of follow-up, the rate of death was not different between the three groups: 33.0% in the Defer group, 31.1% in the Perform group, and 36.1% in the Reference group (Defer vs. Perform, RR 1.06, 95% CI: 0.69-1.62, P = 0.79). The rate of myocardial infarction was significantly lower in the Defer group (2.2%) compared with the Perform group (10.0%), RR 0.22, 95% CI: 0.05-0.99, P = 0.03. CONCLUSION: Deferral of PCI of a functionally non-significant stenosis is associated with a favourable very long-term follow-up without signs of late 'catch-up' phenomenon.


Asunto(s)
Estenosis Coronaria/cirugía , Reserva del Flujo Fraccional Miocárdico/fisiología , Intervención Coronaria Percutánea , Stents , Espera Vigilante , Estenosis Coronaria/mortalidad , Estenosis Coronaria/fisiopatología , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Revascularización Miocárdica/mortalidad , Recurrencia , Reoperación , Resultado del Tratamiento
3.
Circulation ; 105(21): 2482-6, 2002 May 28.
Artículo en Inglés | MEDLINE | ID: mdl-12034653

RESUMEN

BACKGROUND: Guide wire-based simultaneous measurement of fractional flow reserve (FFR) and coronary flow reserve (CFR) is important to understand microvascular disease of the heart. The aim of this study was to investigate the feasibility of simultaneous measurement of FFR and CFR by one pressure-temperature sensor-tipped guide wire with the use of coronary thermodilution and to compare CFR by thermodilution (CFR(thermo)) with simultaneously measured Doppler CFR (CFR(Doppl)). METHODS AND RESULTS: In 103 coronary arteries in 50 patients, a pressure-temperature sensor-tipped 0.014-inch floppy guide wire and a 0.014-inch Doppler guide wire were introduced. Both normal vessels and a wide range of stenotic vessels were included. With 3 mL of saline at room temperature used as an indicator, by hand-injection, thermodilution curves in the coronary artery were obtained in triplicate, both at baseline and at intravenous adenosine-induced maximum hyperemia. After adequate curve-fitting, CFR(thermo) was calculated from the ratio of inverse mean transit times and compared with CFR(Doppl) calculated by velocities at hyperemia and baseline. Adequate sets of thermodilution curves and corresponding CFR(thermo) could be obtained in 87% of the arteries versus 91% for Doppler CFR and 100% for FFR. CFR(thermo) correlated fairly well to CFR(Doppl) (CFR(thermo)=0.84 CFR(Doppl)+0.17; r=0.80; P<0.001), although individual differences of >20% between both indexes were seen in a quarter of all arteries. CONCLUSIONS: This study shows the feasibility of simultaneous measurement of FFR (by coronary pressure) and CFR (by coronary thermodilution) in humans by one single guide wire in a practical and straightforward way and will facilitate assessment of microvascular disease.


Asunto(s)
Circulación Coronaria/fisiología , Estenosis Coronaria , Vasos Coronarios/fisiología , Velocidad del Flujo Sanguíneo/fisiología , Presión Sanguínea/fisiología , Temperatura Corporal , Cateterismo Cardíaco/instrumentación , Cateterismo Cardíaco/métodos , Estenosis Coronaria/diagnóstico , Estenosis Coronaria/fisiopatología , Impedancia Eléctrica , Electrocardiografía , Estudios de Factibilidad , Femenino , Humanos , Flujometría por Láser-Doppler , Masculino , Microcirculación/fisiología , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados , Termodilución/métodos
5.
Int J Cardiovasc Intervent ; 4(2): 67-76, 2001 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-12036474

RESUMEN

Although coronary stents have been the most important improvement in percutaneous coronary interventions in the last 10 years, it is well known to interventionalists that many patients after percutaneous transluminal coronary angioplasty (PTCA) have a favourable outcome without stenting. Coronary angiography, however, is not sensitive enough to identify those particular patients and it has been suggested that a combination of angiographic and functional criteria would be more suitable to distinguish patients with a low restenosis chance after plain balloon angioplasty. In the present study, the authors investigated the value of coronary pressure measurement for conditional stenting in 85 patients. It was demonstrated that in patients in whom a high fractional flow reserve (FFR) was present (> 0.90), the incidence of coronary events at two-year follow-up was almost three times lower than in those patients with an FFR below 0.90. Such high FFRs could be obtained in approximately 45% of all patients. In an additional group of patients, it was demonstrated by intravascular ultrasound (IVUS) studies that the mechanism of a high FFR after plain balloon angioplasty is most likely the result of a larger lumen compared with patients with a suboptimal FFR. This means that, in patients in whom both the angiographic and the functional result after PTCA is optimal, a restenosis rate is achieved similar to that achieved by stenting. Obviously, in such patients, additional stenting and a number of problems in the long-term possibly related to stenting can be avoided. Therefore, coronary angiography and coronary pressure measurement have a complementary value in the evaluation of PTCA results and such information can be easily obtained by using a pressure wire instead of a regular guidewire.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA