Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
J Thorac Cardiovasc Surg ; 164(2): 353-364, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-35016782

RESUMEN

BACKGROUND: Outcomes of ventricular assist device (VAD) support in patients with Fontan circulatory failure (or failing Fontan physiology) are largely unknown. METHODS: We conducted a retrospective analysis of patients with a Fontan circulation who underwent VAD implant in the Society of Thoracic Surgeons Pedimacs and Intermacs Databases from September 19, 2012, to December 31, 2019. RESULTS: We identified 55 Fontan patients who had undergone VAD implant with a median age at implantation of 10.2 years (interquartile range, 6.4-16.9 years) and weight, 26.8 kg (interquartile range, 17.7-53.8 years). More VADs were implanted in 2018-2019 than in 2012-2017 (28 vs 27; P = .01). The later era had higher pre-VAD glomerular filtration rate (101.1 ± 48.5 vs 71.2 ± 34.9; P = .02); there was no difference in Interagency Registry for Mechanically Assisted Circulatory Support profile (P = .69). Kaplan-Meier survival on device was 76% at 6 months with no difference by era. Competing outcomes demonstrated a positive outcome of 81% (alive on VAD, transplanted, or recovered) at 6 months, with 58% of mortality occurring during month 1. Median length of support was 3.8 months (interquartile range, 0.6-6.9 months). Five patients were supported for >1 year with no added mortality; the longest support time was 4 years, 7 months. Adverse event rates included pump thrombosis incidence of 4% (3.3 out of 100 patient-months), stroke 5.5% (1.4 out of 100 patient-months), gastrointestinal bleeding of 7% (2.6 out of 100 patient-months), and nongastrointestinal bleeding of 9% (2.3 out of 100 patient-months). CONCLUSIONS: This is the largest reported analysis of systemic VAD support of Fontan patients. VAD support of the Fontan circulation is becoming more frequent. This analysis demonstrates that VAD use in this growing population can yield promising outcomes.


Asunto(s)
Procedimiento de Fontan , Insuficiencia Cardíaca , Corazón Auxiliar , Cirujanos , Procedimiento de Fontan/efectos adversos , Insuficiencia Cardíaca/etiología , Insuficiencia Cardíaca/cirugía , Corazón Auxiliar/efectos adversos , Humanos , Sistema de Registros , Estudios Retrospectivos , Resultado del Tratamiento
2.
Semin Thorac Cardiovasc Surg ; 33(3): 825-829, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33450408

RESUMEN

The transition of the USMLE to a pass fail system provides a unique opportunity to re-evaluate the residency selection process.


Asunto(s)
Internado y Residencia , Evaluación Educacional , Humanos , Estados Unidos
3.
J Thorac Cardiovasc Surg ; 154(6): 1959-1970.e1, 2017 12.
Artículo en Inglés | MEDLINE | ID: mdl-28526500

RESUMEN

OBJECTIVES: To investigate the effect of pulmonary function testing on outcomes after continuous flow left ventricular assist device implantation. METHODS: A total of 263 and 239 patients, respectively, had tests of forced expiratory volume in 1 second and diffusing capacity of the lungs for carbon monoxide preoperatively for left ventricular assist device implantations between July 2005 and September 2015. Kaplan-Meier analysis and multivariable Cox regressions were performed to evaluate mortality. Patients were analyzed in a single cohort and across 5 groups. Postoperative intensive care unit and hospital lengths of stay were evaluated with negative binomial regressions. RESULTS: There is no association of forced expiratory volume in 1 second and diffusing capacity of the lungs for carbon monoxide with survival and no difference in mortality at 1 and 3 years between the groups (log rank P = .841 and .713, respectively). Greater values in either parameter were associated with decreased hospital lengths of stay. Only diffusing capacity of the lungs for carbon monoxide was associated with increased intensive care unit length of stay in the group analysis (P = .001). Ventilator times, postoperative pneumonia, reintubation, and tracheostomy rates were similar across the groups. CONCLUSIONS: Forced expiratory volume in 1 second and diffusing capacity of the lungs for carbon monoxide are not associated with operative or long-term mortality in patients undergoing continuous flow left ventricular assist device implantation. These findings suggest that these abnormal pulmonary function tests alone should not preclude mechanical circulatory support candidacy.


Asunto(s)
Insuficiencia Cardíaca/terapia , Corazón Auxiliar , Pulmón/fisiopatología , Pruebas de Función Respiratoria , Función Ventricular Izquierda , Adulto , Anciano , Toma de Decisiones Clínicas , Femenino , Volumen Espiratorio Forzado , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/mortalidad , Insuficiencia Cardíaca/fisiopatología , Hemodinámica , Humanos , Unidades de Cuidados Intensivos , Tiempo de Internación , Masculino , Persona de Mediana Edad , Selección de Paciente , Complicaciones Posoperatorias/mortalidad , Complicaciones Posoperatorias/terapia , Valor Predictivo de las Pruebas , Diseño de Prótesis , Capacidad de Difusión Pulmonar , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA