Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 75
Filtrar
Más filtros

Tipo del documento
Intervalo de año de publicación
1.
Catheter Cardiovasc Interv ; 103(1): 209-218, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-37957842

RESUMEN

BACKGROUND: Balloon post-dilation (BPD) is a widely adopted strategy to optimize acute results of TAVI, with a positive impact on both paravalvular leak and mean gradients. On the other hand, the inflation of the balloon inside prosthetic leaflets may damage them increasing the risk of structural valve deterioration (SVD). Furthermore, the impact of BPD on long-term clinical outcomes and valve hemodynamics is yet unknown. AIMS: To evaluate the impact of BPD on valve durability and long-term clinical outcomes in patients undergoing self-expanding transcatheter valve implantation (TAVI). METHODS: Echocardiographic and clinical data from the ClinicalService (a nation-based data repository and medical care project) were analyzed. Patients were divided into two groups, those who underwent BPD after TAVI and those who did not. Coprimary endpoints were all-cause death and SVD. Cumulative incidence functions for SVD were estimated. RESULTS: Among 1835 patients included in the study, 417 (22.7%) underwent BPD and 1418 (77.3%) did not undergo BPD. No statistically significant differences at 6-year follow-up were found between groups in terms of all-cause mortality (HR: 1.05, 95% CI: 0.9-1.22; p = 0.557) and SVD (2.1% vs. 1.4%, p = 0.381). In addition, BPD did not predispose to higher risk of cardiovascular death, myocardial infarction, valve thrombosis, and endocarditis at 6-year follow-up. CONCLUSIONS: BPD following TAVI with a self-expanding prosthesis does not seem to be associated with an increased risk of adverse clinical outcomes or SVD at 6-year follow-up.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/etiología , Dilatación , Resultado del Tratamiento , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Diseño de Prótesis
2.
Catheter Cardiovasc Interv ; 100(2): 190-198, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-35686523

RESUMEN

AIM: The impact of Grade III coronary perforations (G3-CP) in the setting of CTO-PCI is not well assessed. METHODS AND RESULTS: We reviewed 7773 CTO-PCI and 98,819 non CTO-PCI performed in 10 European centers: G3 perforation occurred in 87 patients (1.1%) during CTO PCI and 224 patients (0.22%) during non CTO-PCI (p < 0.001). G3-CP involved the CTO segment in 68% of patients and the retrograde channels in 14% of cases. In the CTO PCI group, wire induced G3-CP (50.5% vs. 32.5%, p = 0.02) occurred predominantly when dedicated CTO tapered and highly penetrative wires were used. Intra-procedural and in-hospital death rates were 4.6% vs. 5.8% and 3.6% vs. 7.5% respectively for CTO PCI and non-CTO PCI groups (p = NS). At a median follow up of 24 months, the overall mortality and MAE were respectively 7.8% and MAE 19% without difference among groups. CONCLUSIONS: We showed similar in-hospital and long-term outcomes when G3 perforations occurred during CTO PCI and non CTO-PCI.


Asunto(s)
Enfermedad de la Arteria Coronaria , Oclusión Coronaria , Lesiones Cardíacas , Intervención Coronaria Percutánea , Lesiones del Sistema Vascular , Enfermedad Crónica , Angiografía Coronaria , Oclusión Coronaria/diagnóstico por imagen , Oclusión Coronaria/terapia , Lesiones Cardíacas/diagnóstico por imagen , Lesiones Cardíacas/etiología , Lesiones Cardíacas/terapia , Mortalidad Hospitalaria , Humanos , Sistema de Registros , Factores de Riesgo , Resultado del Tratamiento , Lesiones del Sistema Vascular/diagnóstico por imagen , Lesiones del Sistema Vascular/etiología , Lesiones del Sistema Vascular/terapia
3.
Eur Heart J Suppl ; 24(Suppl C): C233-C242, 2022 May.
Artículo en Inglés | MEDLINE | ID: mdl-35602251

RESUMEN

Recent evidence has shown that transcatheter heart valve (THV) anchoring in bicuspid aortic valve (BAV) patients occurs at the level of the raphe, known as the LIRA (Level of Implantation at the RAphe) plane. Our previous work in a cohort of 20 patients has shown that the delineation of the perimeter and device sizing at this level is associated with optimal procedural outcome. The goals of this study were to confirm the feasibility of this method, evaluate 30-day outcomes of LIRA sizing in a larger cohort of patients, assess interobserver variation and reproducibility of this sizing methodology, and analyse the interaction of LIRA-sized prostheses with the surrounding anatomy. The LIRA sizing method was applied to consecutive patients presenting to our centre with raphe-type BAV disease between November 2018 and October 2021. Supra-annular self-expanding THVs were sized based on baseline CT scan perimeters at the LIRA plane and the virtual basal ring. In cases where there was discrepancy between the two measurements, the plane with the smallest perimeter was considered the reference for prosthesis sizing. Post-procedural device success, defined according to Valve Academic Research Consortium-2 (VARC-2) criteria, was evaluated in the overall cohort. A total of 50 patients (mean age 80 ± 6 years, 70% male) with raphe-type BAV disease underwent transcatheter aortic valve replacement (TAVR) using different THV prostheses. The LIRA plane method appeared to be highly successful (100% VARC-2 device success) with no procedural mortality, no valve migration, no moderate-severe paravalvular leak, and low transprosthetic gradients (residual mean gradient 8.2 ± 3.4 mmHg). There were no strokes, no in-hospital or 30-day mortality, and an incidence of in-hospital pacemaker implantation of 10%. Furthermore, measurement of the LIRA plane perimeter was highly reproducible between observers (r = 0.980; P < 0.001) and predictive of the post-procedural prosthetic valve perimeter on CT scanning (r = 0.981; P < 0.001). We confirm the feasibility of supra-annular sizing using the LIRA method in a large cohort of patients with high procedural success and good clinical outcomes at 30 days. Application of the LIRA method optimizes THV prosthesis sizing in patients with raphe-type BAV disease.

4.
Catheter Cardiovasc Interv ; 98(2): E299-E305, 2021 08 01.
Artículo en Inglés | MEDLINE | ID: mdl-33315300

RESUMEN

BACKGROUND: Prosthetic valve infolding is a rare but severe complication of transcatheter aortic valve implantation (TAVI) with self-expanding valves. However, currently available clinical data are limited and fragmented. OBJECTIVES: This report aims to provide a comprehensive overview of this complication focusing on predisposing factors, clinical presentation, diagnostic findings, treatment and clinical outcomes. METHODS: A systematic review of the literature was performed to identify cases of infolding occurring during TAVI with self-expanding valves published until August 2020. These data were pooled with all the retrospectively identified infolding cases occurred at San Raffaele Scientific Institute between December 2014 and August 2020. RESULTS: A total of 34 cases were included. Among patients with available data, 38% received a first-generation CoreValve, and 62% a second-generation Evolut R (82%) or Evolut PRO (18%). Infolding occurred mostly with ≥29-mm valves (94%). Predisposing factors included resheathing of a second-generation valve (82%), heavy calcification of the native valve (65%), lack of predilatation (16%), Sievers type-1 bicuspid aortic valve (11%), and improper valve loading (5%). Infolding resulted in severe PVL causing hemodynamic instability (29%) or cardiac arrest (12%). Postdilatation was the treatment strategy in 68%, while prosthesis replacement with a new device in 23% of cases. Device success rate was 82%. Death and stroke occurred in 3% and 12% of cases. CONCLUSIONS: Prosthetic valve infolding is typically observed after resheathing of a large-size self-expanding TAVI. When infolding is timely diagnosed, prosthesis removal and replacement should be pursued. Further studies are required to precisely define predisposing factors to prevent this complication.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Humanos , Diseño de Prótesis , Estudios Retrospectivos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
5.
Catheter Cardiovasc Interv ; 97(1): E40-E50, 2021 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-32320133

RESUMEN

OBJECTIVES: We aimed to evaluate the efficacy and safety of antegrade fenestration and reentry (AFR) for chronic total occlusion (CTO) recanalization in a multicenter registry. BACKGROUND: Adoption of antegrade dissection/reentry (ADR) for CTO recanalization has been limited, and novel ADR techniques are needed. METHODS: AFR involves the balloon-induced creation of multiple fenestrations between the false and true lumen. A targeted true lumen reentry is subsequently achieved with a low tip-load polymer-jacketed guidewire. Following the initial description and dissemination of AFR, patients undergoing AFR-based CTO recanalization at nine centers were included in the present registry. Study endpoints were AFR success, procedural success, and target-lesion failure (TLF) on follow-up. RESULTS: We included 41 patients. Mean J-CTO score was 2.5 ± 1.4. In 80.5% of cases, AFR was performed after failed antegrade wire escalation. Another ADR technique was used before AFR in one-third of cases. AFR achieved distal true lumen reentry in n = 27/41 (65.9%) cases. In n = 14/41 (34.1%) cases with AFR failure, use of alternative techniques led to successful CTO recanalization in eight additional patients. The overall technical and procedural success rates were 85.4% and 82.9%, respectively. No AFR-related complications were observed. One-year TLF rate was 8.3% overall, with no differences between successful and failed AFR. CONCLUSIONS: We report on AFR feasibility in a multicenter registry of patients undergoing CTO recanalization. We observed a moderate success rate, coupled with the absence of complications. Moreover, even a failed AFR attempt did not preclude the use of alternative techniques to achieve recanalization. Further studies should confirm and extend our findings.


Asunto(s)
Oclusión Coronaria , Intervención Coronaria Percutánea , Enfermedad Crónica , Angiografía Coronaria , Oclusión Coronaria/diagnóstico por imagen , Oclusión Coronaria/cirugía , Humanos , Sistema de Registros , Resultado del Tratamiento
6.
Catheter Cardiovasc Interv ; 96(1): E45-E52, 2020 07.
Artículo en Inglés | MEDLINE | ID: mdl-31596537

RESUMEN

OBJECTIVES: To evaluate the incidence of vascular complication and major bleeding in patients undergoing chronic total occlusion (CTO) percutaneous coronary intervention (PCI) with a fully trans-wrist access (TWA) approach versus a conventional approach based on trans-femoral access (TFA). BACKGROUND: TFA is the preferred vascular access in CTO PCI, but it has been associated with a non-negligible risk of complications. METHODS: This retrospective registry included all patients undergoing CTO PCI at five institutions between July 2011 and October 2018. Patients were divided into two groups: Conventional (patients treated with at least one TFA) and Fully TWA (subjects exclusively treated with one or two TWA). The primary safety endpoint was a composite of vascular complications and major bleeding. The primary efficacy endpoint was procedural success. RESULTS: We included 1,900 patients (Conventional n = 1,496 and Fully TWA n = 404). Conventional patients showed higher occlusion complexity (J-CTO score 2.1 ± 1.2 vs. 1.5 ± 1.1, p < .001). Procedural success showed no significant difference between both groups (85.7 vs. 83.0%, p = .17). The primary safety endpoint occurred more frequently in the Conventional group (10.3 vs. 4.5%, p < .001), driven by vascular complications (9.4 vs. 3.7%, p < .001). On multivariate analysis, not using a Fully TWA approach was an independent predictor of the study endpoint, after adjusting for age, sex, diabetes, body mass index, chronic kidney disease, prior coronary artery bypass graft, and J-CTO score. CONCLUSIONS: Embracing a Fully TWA approach for CTO PCI might be associated with lower incidence of a composite endpoint of vascular complications and major bleeding, compared with a Conventional approach.


Asunto(s)
Cateterismo Periférico , Oclusión Coronaria/terapia , Arteria Femoral , Intervención Coronaria Percutánea , Muñeca/irrigación sanguínea , Anciano , Cateterismo Periférico/efectos adversos , Enfermedad Crónica , Oclusión Coronaria/diagnóstico por imagen , Europa (Continente) , Femenino , Hemorragia/etiología , Humanos , Masculino , Persona de Mediana Edad , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/instrumentación , Punciones , Sistema de Registros , Estudios Retrospectivos , Stents , Resultado del Tratamiento , Enfermedades Vasculares/etiología
7.
Eur Heart J Suppl ; 22(Suppl E): E60-E63, 2020 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-32523441

RESUMEN

During the last few years, there has been significant advances in the treatment of patients with severe mitral incompetence either too high risk for surgery or inoperable, this because of the improvements in percutaneous mitral valve prostheses, as alternative to the transcatheter mitral repair techniques. Percutaneous mitral valve replacement offers several advantages over the repair techniques, such as the opportunity to treat mitral valve with different anatomic characteristics, even the more complex ones, and the occasion to correct completely mitral regurgitation. The development of such prostheses has been a long process, still on the making. During the initial stages of the procedure, the transapical approach was preferred. On the other hand, the transseptal approach, which has already been used in some patients, is the proper development path for this transcatheter technique. Many valvular prostheses have been produced, each using a different mechanism for secure anchoring and elimination of regurgitation. Early mortality for this procedure, although decreasing since the preliminary studies, is still high, not only because the technology is still in its initial phase but also for the very high risk of the patients treated. It is foreseeable, though, that in the near future, as the technology and patients selection improves, better results will follow.

9.
Catheter Cardiovasc Interv ; 92(3): 466-476, 2018 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-29314563

RESUMEN

OBJECTIVES: To evaluate the outcomes of subadventitial stenting (SS) around occluded stents for recanalizing in-stent chronic total occlusions (IS-CTOs). BACKGROUND: There is little evidence on the outcomes of SS for IS-CTO. METHODS: We examined the outcomes of SS for IS-CTO PCI at 14 centers between July 2011 and June 2017, and compared them to historical controls recanalized using within-stent stenting (WSS). Target-vessel failure (TVF) on follow-up was the endpoint of this study, and was defined as a composite of cardiac death, target-vessel myocardial infarction, and target-vessel revascularization. RESULTS: During study period, 422 IS-CTO PCIs were performed, of which 32 (7.6%) were recanalized with SS, usually when conventional approaches failed. The most frequent CTO vessel was the right coronary artery (72%). Mean J-CTO score was 3.1 ± 0.9. SS was antegrade in 53%, and retrograde in 47%. Part of the occluded stent was crushed in 37%, while the whole stent was crushed in 63%. Intravascular imaging was used in 59%. One patient (3.1%) suffered tamponade. Angiographic follow-up was performed in 10/32 patients: stents were patent in six cases, one had mild neointimal hyperplasia, and three had severe restenosis at the SS site. Clinical follow-up was available for 29/32 patients for a mean of 388 ± 303 days. The 24-month incidence of TVF was 13.8%, which was similar to historical controls treated with WSS (19.5%, P = 0.49). CONCLUSIONS: SS is rarely performed, usually as last resort, to recanalize complex IS-CTOs. It is associated with favorable acute and mid-term outcomes, but given the small sample size of our study additional research is warranted.


Asunto(s)
Oclusión Coronaria/terapia , Reestenosis Coronaria/terapia , Stents Liberadores de Fármacos , Intervención Coronaria Percutánea , Anciano , Australia , Canadá , Enfermedad Crónica , Angiografía por Tomografía Computarizada , Angiografía Coronaria/métodos , Oclusión Coronaria/diagnóstico por imagen , Oclusión Coronaria/etiología , Oclusión Coronaria/mortalidad , Reestenosis Coronaria/diagnóstico por imagen , Reestenosis Coronaria/etiología , Reestenosis Coronaria/mortalidad , Europa (Continente) , Femenino , Humanos , Masculino , Persona de Mediana Edad , Tomografía Computarizada Multidetector , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/instrumentación , Intervención Coronaria Percutánea/métodos , Intervención Coronaria Percutánea/mortalidad , Diseño de Prótesis , Sistema de Registros , Retratamiento , Estudios Retrospectivos , Factores de Tiempo , Tomografía de Coherencia Óptica , Resultado del Tratamiento , Ultrasonografía Intervencional , Estados Unidos , Grado de Desobstrucción Vascular
10.
Catheter Cardiovasc Interv ; 89(5): 820-828, 2017 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-28029214

RESUMEN

OBJECTIVES: To study the long-term outcomes of rotational atherectomy (RA) for chronic total occlusion (CTO) percutaneous coronary intervention (PCI). BACKGROUND: There is little evidence on the incidence, procedural results and long-term outcomes of RA for CTO PCI. METHODS: This registry included data from consecutive patients undergoing CTO PCI at four specialized centers. Major adverse cardiac events (MACE: cardiac death, target-vessel myocardial infarction and ischemia-driven target-vessel revascularization) on follow-up were the primary endpoint. RESULTS: A total of 1003 patients were included. Of these, 35 (3.5%) required RA. As compared with Conventional PCI, RA patients were older (68.9 ± 9.5 vs. 64.6 ± 10.7 years, P = 0.02), had higher prevalence of diabetes (58% vs. 37%, P = 0.01) and of a J-CTO score ≥2 (80% vs. 58%, P = 0.009), driven by severe calcification. Antegrade wire escalation was used more frequently in RA (74% vs. 53%, P = 0.08). RA was performed for balloon failure-to-cross in 51% and failure-to-expand in 49%. One burr was utilized in 86%. The 1.25-mm burr was the largest burr used in 43%. Slow flow/no-reflow was observed in 17%. No other serious RA-related complications were observed. Procedural success was 77% vs. 89% (P = 0.04) in RA vs. Conventional PCI. After a mean follow-up of 658 ± 412 days, MACE rates were similar between groups (15% vs. 13%, P = 0.70). CONCLUSIONS: The use of RA in CTO PCI was safe, despite a worse patient risk profile and higher procedural complexity, as compared with conventional techniques. Although procedural success was lower in the RA group, there were no differences in long-term clinical outcomes between groups. © 2016 Wiley Periodicals, Inc.


Asunto(s)
Aterectomía Coronaria/métodos , Oclusión Coronaria/cirugía , Intervención Coronaria Percutánea/métodos , Sistema de Registros , Anciano , Enfermedad Crónica , Angiografía Coronaria , Oclusión Coronaria/diagnóstico , Femenino , Estudios de Seguimiento , Humanos , Incidencia , Italia/epidemiología , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/epidemiología , Prevalencia , Estudios Retrospectivos , Factores de Tiempo , Resultado del Tratamiento
12.
J Cardiovasc Dev Dis ; 11(5)2024 May 17.
Artículo en Inglés | MEDLINE | ID: mdl-38786975

RESUMEN

Mitral stenosis (MS) poses significant challenges in diagnosis and management due to its varied etiologies, such as rheumatic mitral stenosis (RMS) and degenerative mitral stenosis (DMS). While rheumatic fever-induced RMS has declined in prevalence, DMS is rising with aging populations and comorbidities. Starting from a complex clinical case of DMS, the aim of this paper is to review the literature on mitral stenosis by analyzing the available tools and the differences in terms of diagnosis and treatment for rheumatic and degenerative stenosis. Emerging transcatheter techniques, such as transcatheter mitral valve replacement (TMVR) and lithotripsy-facilitated percutaneous mitral commissurotomy (PMC), represent promising alternatives for DMS patients deemed unfit for surgery. In particular, intravascular lithotripsy (IVL) has shown potential in facilitating percutaneous interventions by fracturing calcific deposits and enabling subsequent interventions. However, larger prospective studies are warranted to validate these findings and establish IVL's role in DMS management. To further enhance this technique, research could focus on investigating the long-term outcomes and durability of mitral lithotripsy, as well as exploring its potential in combination with PMC or TMVR.

13.
G Ital Cardiol (Rome) ; 25(5): 295-299, 2024 May.
Artículo en Italiano | MEDLINE | ID: mdl-38639118

RESUMEN

Patent foramen ovale (PFO) is a remnant of normal fetal anatomy which may persist into adulthood, mostly asymptomatic. In some adults, PFO may result in a potential for shunting venous thromboembolism to the arterial circulation; less frequently it can cause interatrial, right-to-left shunting of deoxygenated blood. The pathogenesis of several medical conditions is related to the presence of PFO. Some randomized clinical trials have shown evidence of benefit for device closure as compared with medical therapy in patients with cryptogenic stroke. The literature reported several cases of carbon dioxide embolism during general laparoscopic surgery and sometimes stroke after laparoscopic or neurosurgery but there are neither prospective studies addressing these issues, nor randomized clinical trials assessing the effectiveness of pharmacotherapy or interventional procedures at decreasing risk. The European position paper suggests routine monitoring in non-cardiac surgery of patients with a PFO and no actual indications for closure. This article aims to further stratify the risk of periprocedural stroke and paradoxical embolism in this category of patients.


Asunto(s)
Embolia Paradójica , Foramen Oval Permeable , Accidente Cerebrovascular , Adulto , Humanos , Embolia Paradójica/etiología , Embolia Paradójica/prevención & control , Foramen Oval Permeable/complicaciones , Foramen Oval Permeable/cirugía , Estudios Prospectivos , Prevención Secundaria/métodos , Accidente Cerebrovascular/prevención & control , Accidente Cerebrovascular/complicaciones , Resultado del Tratamiento
14.
Cardiovasc Revasc Med ; 62: 85-94, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38160130

RESUMEN

Valve-in-valve transcatheter aortic valve implantation (ViV TAVI) is rapidly arising as a safe and effective alternative to redo-surgery in the treatment of bioprostheses deterioration. While scientific community is currently focusing its attention on the most common limitations related to this procedure, such as the risk of coronary obstruction and patient-prosthesis mismatch, data regarding the first step of a ViV TAVI, the crossing of a degenerated bioprosthesis, are still lacking. The aim of this review is to analyze the available information about bioprosthesis crossing, to show the inherent challenges encountered by interventional cardiologists during valve crossing and to describe the current strategies to perform a correct crossing.


Asunto(s)
Válvula Aórtica , Bioprótesis , Prótesis Valvulares Cardíacas , Diseño de Prótesis , Falla de Prótesis , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Resultado del Tratamiento , Factores de Riesgo , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/fisiopatología , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos
15.
EuroIntervention ; 20(5): e289-e300, 2024 Mar 04.
Artículo en Inglés | MEDLINE | ID: mdl-37982178

RESUMEN

BACKGROUND: Microvascular resistance reserve (MRR) is a validated measure of coronary microvascular function independent of epicardial resistances. AIMS: We sought to assess whether MRR is associated with adverse cardiac remodelling, a low-flow phenotype and extravalvular cardiac damage (EVCD) in patients with severe aortic stenosis (AS) undergoing transcatheter aortic valve implantation (TAVI). METHODS: Invasive thermodilution-based assessment of the coronary microvascular function of the left anterior descending artery was performed in a prospective, multicentre cohort of patients undergoing TAVI. Coronary microvascular dysfunction (CMD) was defined as the lowest MRR tertile of the study cohort. Haemodynamic measurements were performed at baseline and then repeated immediately after TAVI. EVCD and markers of a low-flow phenotype were assessed with echocardiography. RESULTS: A total of 134 patients were included in this study. Patients with low MRR were more frequently females, had a lower estimated glomerular filtration rate and a higher rate of atrial fibrillation. MRR was significantly lower in patients with advanced EVCD (median 1.80 [1.26-3.30] vs 2.50 [1.87-3.41]; p=0.038) and in low-flow, low-gradient AS (LF LG-AS) (median 1.85 [1.20-3.04] vs 2.50 [1.87-3.40]; p=0.008). Overall, coronary microvascular function tended to improve after TAVI and, in particular, MRR increased significantly after TAVI in the subgroup with low MRR at baseline. However, MRR was significantly impaired in 38 (28.4%) patients immediately after TAVI. Advanced EVCD (adjusted odds ratio 3.08 [1.22-7.76]; p=0.017) and a low-flow phenotype (adjusted odds ratio 3.36 [1.08-10.47]; p=0.036) were significant predictors of CMD. CONCLUSIONS: In this observational, hypothesis-generating study, CMD was associated with extravalvular cardiac damage and a low-flow phenotype in patients with severe AS undergoing TAVI.


Asunto(s)
Estenosis de la Válvula Aórtica , Isquemia Miocárdica , Reemplazo de la Válvula Aórtica Transcatéter , Femenino , Humanos , Masculino , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estudios Prospectivos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
16.
Artículo en Inglés | MEDLINE | ID: mdl-38749449

RESUMEN

BACKGROUND: Transcatheter aortic valve replacement (TAVR) in patients with bicuspid aortic valve (BAV) stenosis is technically challenging and is burdened by an increased risk of paravalvular regurgitation (PVR). OBJECTIVES: To identify the incidence, predictors, and clinical outcomes of PVR following TAVR in Sievers type 1 BAV stenosis. METHODS: Consecutive patients with severe Sievers type 1 BAV stenosis undergoing TAVR with current generation transcatheter heart valves (THVs) in 24 international centres were enrolled. PVR was graded as none/trace, mild, moderate, and severe according to echocardiographic criteria. The endpoint of major adverse events (MAE), defined as a composite of all-cause death, stroke, or hospitalization for heart failure, was assessed at the last available follow-up. RESULTS: A total of 946 patients were enrolled. PVR occurred in 423 patients (44.7%): mild, moderate, and severe in 387 (40.9%), 32 (3.4%), and 4 (0.4%) patients, respectively. Independent predictors of moderate or severe PVR were larger virtual raphe ring (VRR) perimeter (ORadj 1.07, 95% CI 1.02-1.13), severe annular or left ventricular outflow tract (LVOT) calcification (ORadj 5.21, 95% CI 1.45-18.77), self-expanding valve (ORadj 9.01, 95% CI 2.09-38.86), and intentional supra-annular THV positioning (ORadj 3.31, 95% CI 1.04-10.54). At a median follow-up of 1.3 [IQR 0.5-2.4] years, moderate or severe PVR was associated with an increased risk of MAE (HRadj 2.52, 95% CI 1.24-5.09). CONCLUSIONS: After TAVR with current-generation THVs in Sievers type 1 BAV stenosis, moderate or severe PVR occurred in about 4% of cases and was associated with an increased risk of MAE during follow-up.

17.
Pacing Clin Electrophysiol ; 36(4): 486-90, 2013 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-23356212

RESUMEN

BACKGROUND: Irrigated-tip catheter technology has been used for the elimination of resistant accessory pathways (AP) in adults with Wolff-Parkinson-White (WPW) syndrome. However, there are persistent concerns regarding the safety of irrigated catheters in the pediatric population. In this report we present our experience, in terms of effectiveness and safety, of irrigated catheter technology in children and adolescents who underwent ablation of WPW. METHODS: We prospectively followed up all patients less than 18 years old (n = 41, mean age of 12.8 years old) who were referred to our center for radiofrequency (RF) catheter ablation of WPW between January 2010 and July 2011. Catheter ablation was performed in all patients using an open irrigated-tip catheter (Celsius Thermocool 3.5 mm, 7F, B-type, Biosense Webster, Diamond Bar, CA, USA). Power was started from 15 W up to 30 W in right-sided AP; RF pulses in left-sided APs were delivered at 40 W while 20 W was delivered inside the coronary sinus. RESULTS: Mean procedure time was 26.4 minutes and mean fluoroscopy time was 12.2 minutes. Overall procedural success was obtained in 39/41 (95.1%) patients after the first procedure. No complications were observed after the procedure. All patients attended their scheduled follow-up visit at 3, 6, and 12 months and no recurrences were observed based on 12-lead electrocardiogram and 24-hour Holter monitoring. CONCLUSIONS: RF ablation of APs using open irrigated-tip catheters can be performed in children and adolescents with a high acute and long-term success rate, very short procedure times, and acceptable fluoroscopy times.


Asunto(s)
Ablación por Catéter/instrumentación , Síndrome de Wolff-Parkinson-White/cirugía , Adolescente , Niño , Electrocardiografía , Electrocardiografía Ambulatoria , Femenino , Fluoroscopía , Estudios de Seguimiento , Humanos , Masculino , Estudios Prospectivos , Irrigación Terapéutica , Resultado del Tratamiento
18.
JACC Case Rep ; 22: 101978, 2023 Sep 20.
Artículo en Inglés | MEDLINE | ID: mdl-37790775

RESUMEN

Ischemia with no obstructive coronary artery disease (INOCA) is not an uncommon diagnosis in patients presenting with chest pain who undergo clinically indicated coronary angiography. However, the symptoms reported by patients with INOCA may be heterogeneous, leading to misdiagnosis and undertreatment. Herein we report 3 clinical cases of INOCA misdiagnosis and describe how the cases were reinvestigated following the appropriate diagnostic pathway. (Level of Difficulty: Advanced.).

19.
Int J Cardiol ; 389: 131188, 2023 10 15.
Artículo en Inglés | MEDLINE | ID: mdl-37453454

RESUMEN

BACKGROUND: LAAO is an emerging option for thromboembolic event prevention in patients with NVAF. We previously reported data on comparison between LAAO and DOAC at two-year follow-up in NVAF patients at HBR (HAS-BLED ≥3). AIMS: Limited data are available on long term follow-up. We aimed to evaluate the efficacy and safety of DOACs versus LAAO indication after 5 years. METHODS: We enrolled 193 HBR treated with LAAO and 189 HBR patients with DOACs. At baseline, LAAO group had higher HAS-BLED (4.2 vs 3.3, p < 0.001) and lower CHADS-VASc (4.3 vs. 4.7, p = 0.005). After 1:1 PSM, 192 patients were included (LAAO n = 96; DOACs n = 96). RESULTS: At 5-year follow-up the rate of the combined safety and effectiveness endpoint (ISTH major bleeding and thromboembolic events) was significantly higher in LAAO group (p = 0.042), driven by a higher number of thromboembolic events (p = 0.047). The rate of ISTH-major bleeding events was similar (p = 0.221). After PSM no significant difference in the primary effectiveness (LAAO 13.3% vs DOACs 9.5%, p = 0.357) and safety endpoint (LAAO 7.5% vs DOACs 7.5%; p = 0.918) were evident. Overall bleeding rate was significantly higher in DOACs group (25.0% vs 13.7%, p = 0.048), while a non-significant higher number of TIA was reported in LAAO group (5.4% vs 1.1%, p = 0.098). All-cause and cardiovascular mortality were higher in LAAO group at both unmatched and matched analysis. CONCLUSION: We confirmed safety and effectiveness of both DOAC and LAAO in NVAF patients at HBR, with no significant differences in thromboembolic events or major bleeding were at 5-year follow-up. The observed increased mortality after LAAO warrants further investigations in RCTs.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Accidente Cerebrovascular , Tromboembolia , Humanos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/tratamiento farmacológico , Fibrilación Atrial/cirugía , Accidente Cerebrovascular/epidemiología , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/prevención & control , Apéndice Atrial/cirugía , Hemorragia/inducido químicamente , Anticoagulantes/efectos adversos , Tromboembolia/epidemiología , Tromboembolia/etiología , Tromboembolia/prevención & control , Resultado del Tratamiento
20.
Cardiovasc Revasc Med ; 43: 1-6, 2022 10.
Artículo en Inglés | MEDLINE | ID: mdl-35690553

RESUMEN

BACKGROUND: Transcatheter aortic valve implant (TAVI) is gaining momentum in the treatment of severe, symptomatic aortic valve stenosis, and its indication is expanding to lower surgical risk individuals, who are generally younger and have a long life expectancy. Therefore, transcatheter bioprostheses durability appears of critical importance. Aim of the present study is to evaluate mid-term outcomes of TAVI in a high-volume single center cohort. METHODS: We analyzed all consecutive patients (n = 408) who underwent transfemoral TAVI at a single, high-volume center, between 2007 and 2014. Study objectives were all-cause death and bioprosthetic valve failure (BVF) at long term follow-up. Structural valve deterioration (SVD), BVF and valve-related death were defined according to current international standards. Follow-up was performed by in person visit and transthoracic echocardiography, which was obtained only in a minority of patients, or phone call as per patient preference. RESULTS: At a median follow-up of 1821 days, overall mortality was 64.5%, with cardiovascular disease accounting for roughly half of total deaths. Valve-related deaths occurred in 10 patients. Seventeen patients were diagnosed with BVF, and 15 required repeat intervention. Moderate and severe SVD were observed in 10 and 7 patients, respectively. In the subgroup of patients with echocardiographic mid-term follow-up (n = 76), no significant increase of transprosthetic gradients nor increase of significant regurgitation was detected. CONCLUSION: In the present unselected, all-comers cohort, TAVI bioprostheses appeared to have excellent durability at long-term follow-up.


Asunto(s)
Estenosis de la Válvula Aórtica , Bioprótesis , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Humanos , Diseño de Prótesis , Falla de Prótesis , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA