1.
Biomed Microdevices ; 16(1): 97-106, 2014 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-24132857

RESUMEN

Magnetic resonance imaging (MRI) guided minimally invasive interventions are an emerging technology. We developed a microcatheter that utilizes micro-electromagnets manufactured on the distal tip, in combination with the magnetic field of a MRI scanner, to perform microcatheter steering during endovascular surgery. The aim of this study was to evaluate a user control system for operating, steering and monitoring this magnetically guided microcatheter. The magnetically-assisted remote control (MARC) microcatheter was magnetically steered within a phantom in the bore of a 1.5 T MRI scanner. Controls mounted in an interventional MRI suite, along with a graphical user interface at the MRI console, were developed with communication enabled via MRI compatible hardware modules. Microcatheter tip deflection measurements were performed by evaluating MRI steady-state free precession (SSFP) images and compared to models derived from magnetic moment interactions and composite beam mechanics. The magnitude and direction of microcatheter deflections were controlled with user hand, foot, and software controls. Data from two different techniques for measuring the microcatheter tip location within a 1.5 T MRI scanner showed correlation of magnetic deflections to our model (R(2): 0.88) with a region of linear response (R(2): 0.98). Image processing tools were successful in autolocating the in vivo microcatheter tip within MRI SSFP images. Our system showed good correlation to response curves and introduced low amounts of MRI noise artifact. The center of the artifact created by the energized microcatheter solenoid was a reliable marker for determining the degree of microcatheter deflection and auto-locating the in vivo microcatheter tip.


Asunto(s)
Artefactos , Catéteres , Procedimientos Endovasculares/métodos , Magnetismo/instrumentación , Animales , Diseño de Equipo , Procesamiento de Imagen Asistido por Computador , Campos Magnéticos , Imagen por Resonancia Magnética Intervencional , Modelos Animales , Modelos Teóricos , Fantasmas de Imagen , Porcinos
2.
J Vasc Interv Radiol ; 24(6): 885-91, 2013 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-23707097

RESUMEN

PURPOSE: To evaluate deflection capability of a prototype endovascular catheter, which is remotely magnetically steerable, for use in the interventional magnetic resonance (MR) imaging environment. MATERIALS AND METHODS: Copper coils were mounted on the tips of commercially available 2.3-3.0-F microcatheters. The coils were fabricated in a novel manner by plasma vapor deposition of a copper layer followed by laser lithography of the layer into coils. Orthogonal helical (ie, solenoid) and saddle-shaped (ie, Helmholtz) coils were mounted on a single catheter tip. Microcatheters were tested in water bath phantoms in a 1.5-T clinical MR scanner, with variable simultaneous currents applied to the coils. Catheter tip deflection was imaged in the axial plane by using a "real-time" steady-state free precession MR imaging sequence. Degree of deflection and catheter tip orientation were measured for each current application. RESULTS: The catheter tip was clearly visible in the longitudinal and axial planes. Magnetic field artifacts were visible when the orthogonal coils at the catheter tip were energized. Variable amounts of current applied to a single coil demonstrated consistent catheter deflection in all water bath experiments. Changing current polarity reversed the observed direction of deflection, whereas current applied to two different coils resulted in deflection represented by the composite vector of individual coil activations. Microcatheter navigation through the vascular phantom was successful through control of applied current to one or more coils. CONCLUSIONS: Controlled catheter deflection is possible with laser lithographed multiaxis coil-tipped catheters in the MR imaging environment.


Asunto(s)
Cateterismo Periférico/instrumentación , Procedimientos Endovasculares/instrumentación , Imagen por Resonancia Magnética Intervencional/instrumentación , Magnetismo/instrumentación , Micromanipulación/instrumentación , Diseño de Equipo , Análisis de Falla de Equipo , Humanos , Fantasmas de Imagen
3.
J Magn Reson ; 189(1): 121-9, 2007 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-17897853

RESUMEN

Nuclear Magnetic Resonance (NMR) is unsurpassed in its ability to non-destructively probe chemical identity. Portable, low-cost NMR sensors would enable on-site identification of potentially hazardous substances, as well as the study of samples in a variety of industrial applications. Recent developments in RF microcoil construction (i.e. coils much smaller than the standard 5mm NMR RF coils), have dramatically increased NMR sensitivity and decreased the limits-of-detection (LOD). We are using advances in laser pantographic microfabrication techniques, unique to LLNL, to produce RF microcoils for field deployable, high sensitivity NMR-based detectors. This same fabrication technique can be used to produce imaging coils for MRI as well as for standard hardware shimming or "ex-situ" shimming of field inhomogeneities typically associated with inexpensive magnets. This paper describes a portable NMR system based on the use of a 2 kg hand-held permanent magnet, laser-fabricated microcoils, and a compact spectrometer. The main limitations for such a system are the low resolution and sensitivity associated with the low field values and quality of small permanent magnets, as well as the lack of large amounts of sample of interest in most cases. The focus of the paper is on the setting up of this system, initial results, sensitivity measurements, discussion of the limitations and future plans. The results, even though preliminary, are promising and provide the foundation for developing a portable, inexpensive NMR system for chemical analysis. Such a system will be ideal for chemical identification of trace substances on site.


Asunto(s)
Espectroscopía de Resonancia Magnética/instrumentación , Algoritmos , Diseño de Equipo , Espectroscopía de Resonancia Magnética/economía , Espectroscopía de Resonancia Magnética/métodos
4.
Med Phys ; 34(8): 3135-42, 2007 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-17879774

RESUMEN

Current applied to wire coils wound at the tip of an endovascular catheter can be used to remotely steer a catheter under magnetic resonance imaging guidance. In this study, we derive and validate an equation that characterizes the relationship between deflection and a number of physical factors: theta/sin(gamma-theta) = nIABL/EI(A) where theta is the deflection angle, n is the number of solenoidal turns, I is the current, A is the cross-sectional area of the catheter tip, B is the magnetic resonance (MR) scanner main magnetic field, L is the unconstrained catheter length, E is Young's Modulus for the catheter material, and I(A) is the area moment of inertia, and y is the initial angle between the catheter tip and B. Solenoids of 50, 100, or 150 turns were wound on 1.8 F and 5 F catheters. Varying currents were applied remotely using a DC power supply in the MRI control room. The distal catheter tip was suspended within a phantom at varying lengths. Images were obtained with a 1.5 T or a 3 T MR scanner using "real-time" MR pulse sequences. Deflection angles were measured on acquired images. Catheter bending stiffess was determined using a tensile testing apparatus and a stereomicroscope. Predicted relationships between deflection and various physical factors were observed (R2 = 0.98-0.99). The derived equation provides a framework for modeling of the behavior of the specialized catheter tip. Each physical factor studied has implications for catheter design and device implementation.


Asunto(s)
Cateterismo Periférico/instrumentación , Cateterismo , Imagen por Resonancia Magnética Intervencional/instrumentación , Imagen por Resonancia Magnética Intervencional/métodos , Magnetismo , Elasticidad , Diseño de Equipo , Humanos , Aumento de la Imagen , Procesamiento de Imagen Asistido por Computador , Fantasmas de Imagen
5.
J Vis Exp ; (74)2013 Apr 04.
Artículo en Inglés | MEDLINE | ID: mdl-23609143

RESUMEN

X-ray fluoroscopy-guided endovascular procedures have several significant limitations, including difficult catheter navigation and use of ionizing radiation, which can potentially be overcome using a magnetically steerable catheter under MR guidance. The main goal of this work is to develop a microcatheter whose tip can be remotely controlled using the magnetic field of the MR scanner. This protocol aims to describe the procedures for applying current to the microcoil-tipped microcatheter to produce consistent and controllable deflections. A microcoil was fabricated using laser lathe lithography onto a polyimide-tipped endovascular catheter. In vitro testing was performed in a waterbath and vessel phantom under the guidance of a 1.5-T MR system using steady-state free precession (SSFP) sequencing. Various amounts of current were applied to the coils of the microcatheter to produce measureable tip deflections and navigate in vascular phantoms. The development of this device provides a platform for future testing and opportunity to revolutionize the endovascular interventional MRI environment.


Asunto(s)
Cateterismo Cardíaco/instrumentación , Cateterismo Cardíaco/métodos , Campos Magnéticos , Angiografía por Resonancia Magnética/instrumentación , Angiografía por Resonancia Magnética/métodos , Dispositivos de Acceso Vascular
6.
Acad Radiol ; 18(3): 270-6, 2011 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-21075017

RESUMEN

RATIONALE AND OBJECTIVES: The aims of this study were to assess resistive heating of microwires used for remote catheter steering in interventional magnetic resonance imaging and to investigate the use of alumina to facilitate heat transfer to saline flowing in the catheter lumen. MATERIALS AND METHODS: A microcoil was fabricated using a laser lathe onto polyimide-tipped or alumina-tipped endovascular catheters. In vitro testing was performed on a 1.5-T magnetic resonance system using a vessel phantom, body radiofrequency coil, and steady-state pulse sequence. Resistive heating was measured with water flowing over a polyimide-tip catheter or saline flowing through the lumen of an alumina-tip catheter. Preliminary in vivo testing in porcine common carotid arteries was conducted with normal blood flow or after arterial ligation when current was applied to an alumina-tip catheter for up to 5 minutes. RESULTS: After application of up to 1 W of direct current power, clinically significant temperature increases were noted with the polyimide-tip catheter: 23°C/W at zero flow, 13°C/W at 0.28 cm(3)/s, and 7.9°C/W at 1 cm(3)/s. Using the alumina-tip catheter, the effluent temperature rise using the lowest flow rate (0.12 cm(3)/s) was 2.3°C/W. In vivo testing demonstrated no thermal injury to vessel walls at normal and zero arterial flow. CONCLUSIONS: Resistive heating in current carrying wire pairs can be dissipated by saline coolant flowing within the lumen of a catheter tip composed of material that facilitates heat transfer.


Asunto(s)
Cateterismo Periférico/instrumentación , Catéteres , Imagen por Resonancia Magnética Intervencional/instrumentación , Magnetismo/instrumentación , Cirugía Asistida por Computador/instrumentación , Quemaduras por Electricidad/etiología , Quemaduras por Electricidad/prevención & control , Cateterismo Periférico/efectos adversos , Impedancia Eléctrica , Diseño de Equipo , Análisis de Falla de Equipo , Calor , Humanos , Imagen por Resonancia Magnética Intervencional/efectos adversos , Cirugía Asistida por Computador/efectos adversos
7.
Acad Radiol ; 18(3): 277-85, 2011 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-21075019

RESUMEN

RATIONALE AND OBJECTIVES: The aim of this study was too assess magnetic resonance imaging (MRI) radiofrequency (RF)-related heating of conductive wire coils used in magnetically steerable endovascular catheters. MATERIALS AND METHODS: A three-axis microcoil was fabricated onto a 1.8Fr catheter tip. In vitro testing was performed on a 1.5-T MRI system using an agarose gel-filled vessel phantom, a transmit-receive body RF coil, a steady-state free precession pulse sequence, and a fluoroptic thermometry system. Temperature was measured without simulated blood flow at varying distances from the magnet isocenter and at varying flip angles. Additional experiments were performed with laser-lithographed single-axis microcoil-tipped microcatheters in air and in a saline bath with varied grounding of the microcoil wires. Preliminary in vivo evaluation of RF heating was performed in pigs at 1.5 T with coil-tipped catheters in various positions in the common carotid arteries with steady-state free precession pulse sequence on and off and under physiologic-flow and zero-flow conditions. RESULTS: In tissue-mimicking agarose gel, RF heating resulted in a maximal temperature increase of 0.35°C after 15 minutes of imaging, 15 cm from the magnet isocenter. For a single-axis microcoil, maximal temperature increases were 0.73°C to 1.91°C in air and 0.45°C to 0.55°C in saline. In vivo, delayed contrast-enhanced MRI revealed no evidence of vascular injury, and histopathologic sections from the common carotid arteries confirmed the lack of vascular damage. CONCLUSIONS: Microcatheter tip microcoils for endovascular catheter steering in MRI experience minimal RF heating under the conditions tested. These data provide the basis for further in vivo testing of this promising technology for endovascular interventional MRI.


Asunto(s)
Cateterismo Periférico/instrumentación , Catéteres , Imagen por Resonancia Magnética Intervencional/instrumentación , Magnetismo/instrumentación , Cirugía Asistida por Computador/instrumentación , Quemaduras por Electricidad/etiología , Quemaduras por Electricidad/prevención & control , Cateterismo Periférico/efectos adversos , Impedancia Eléctrica , Diseño de Equipo , Análisis de Falla de Equipo , Calor , Humanos , Imagen por Resonancia Magnética Intervencional/efectos adversos , Ondas de Radio , Cirugía Asistida por Computador/efectos adversos
8.
J Magn Reson ; 200(1): 56-63, 2009 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-19581116

RESUMEN

Nuclear magnetic resonance (NMR) offers a non-destructive, powerful, structure-specific analytical method for the identification of chemical and biological systems. The use of radio frequency (RF) microcoils has been shown to increase the sensitivity in mass-limited samples. Recent advances in micro-receiver technology have further demonstrated a substantial increase in mass sensitivity [D.L. Olson, T.L. Peck, A.G. Webb, R.L. Magin, J.V. Sweedler, High-resolution microcoil H-1-NMR for mass-limited, nanoliter-volume samples, Science 270 (5244) (1995) 1967-1970]. Lithographic methods for producing solenoid microcoils possess a level of flexibility and reproducibility that exceeds previous production methods, such as hand winding microcoils. This paper presents electrical characterizations of RF microcoils produced by a unique laser lithography system that can pattern three dimensional surfaces and compares calculated and experimental results to those for wire wound RF microcoils. We show that existing optimization conditions for RF coil design still hold true for RF microcoils produced by lithography. Current lithographic microcoils show somewhat inferior performance to wire wound RF microcoils due to limitations in the existing electroplating technique. In principle, however, when the pitch of the RF microcoil is less than 100mum lithographic coils should show comparable performance to wire wound coils. In the cases of larger pitch, wire cross sections can be significantly larger and resistances lower than microfabricated conductors.


Asunto(s)
Espectroscopía de Resonancia Magnética/instrumentación , Algoritmos , Simulación por Computador , Cobre , Campos Electromagnéticos , Diseño de Equipo , Rayos Láser , Modelos Estadísticos , Nanotecnología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA