Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Radiology ; 279(2): 420-31, 2016 May.
Artículo en Inglés | MEDLINE | ID: mdl-26599801

RESUMEN

PURPOSE: To prospectively compare the accuracies of computed tomographic (CT) enterography and magnetic resonance (MR) enterography for the detection and characterization of small-bowel diseases. MATERIALS AND METHODS: The institutional review board approved the study protocol, and informed consent was obtained from all participants. From June 2009 to July 2013, 150 consecutive patients (81 men and 69 women; mean age, 38.8 years; range, 18-74 years), who were suspected of having a small-bowel disease on the basis of clinical findings and whose previous upper and lower gastrointestinal endoscopy findings were normal, underwent CT and MR enterography. Two independent readers reviewed CT and MR enterographic images for the presence of small-bowel diseases, for differentiating between inflammatory and noninflammatory diseases, and for extraenteric complications. The histopathologic findings of surgical (n = 23) and endoscopic (n = 32) biopsy specimens were used as the reference standard; the results of video-capsule endoscopy (n = 36) and clinical follow-up (n = 59) were used only to confirm the absence of small-bowel disease. RESULTS: MR and CT enterography were successfully performed in all 150 patients. Overall sensitivity, specificity, and accuracy, respectively, in identifying patients with small-bowel lesions were 75.9% (41 of 54), 94.8% (91 of 96), and 88.0% (132 of 150) for CT enterography and 92.6% (50 of 54), 99.0% (95 of 96), and 96.7% (145 of 150) for MR enterography. The sensitivity of MR enterography was significantly higher than that of CT enterography for the detection of both overall small-bowel diseases (P = .0159) and neoplastic diseases (P = .0412) but not for the detection of inflammatory diseases (P > .99) or noninflammatory and nonneoplastic diseases (P = .6171). CONCLUSION: MR enterography is more accurate than CT enterography in the detection of small-bowel diseases; MR enterography was more accurate in detecting neoplastic diseases in particular.


Asunto(s)
Enfermedades Intestinales/diagnóstico , Intestino Delgado , Imagen por Resonancia Magnética/métodos , Tomografía Computarizada por Rayos X/métodos , Adolescente , Adulto , Anciano , Biopsia , Endoscopía Capsular , Diagnóstico Diferencial , Endoscopía Gastrointestinal , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos
2.
Surg Endosc ; 30(9): 3741-8, 2016 09.
Artículo en Inglés | MEDLINE | ID: mdl-26675935

RESUMEN

BACKGROUND: Since the great diffusion of laparoscopic treatment of obesity, there is a growing interest concerning the learning process for those surgeons who undertake the bariatric activity. However, papers analyzing the learning curve (LC) for sleeve gastrectomy (SG) are still scarce. This study aims to investigate whether the LC for SG of a novice bariatric surgeon might be positively influenced by the training in a high-volume bariatric center (HVBC). METHODS: Between October 2010 and January 2014, 128 patients underwent SG by the same young surgeon who previously attended a 2-year training in a HVBC. His LC has been divided into three consecutive periods: in the first period (1st-47th SGs) he operated in the HVBC, while in the second (48th-88th SGs) and third period (89th-128th SGs) he moved to a novel department where surgical and ancillary staff were initially not confident with bariatric procedures but progressively owned the proper experience. Preoperative characteristics, operative data, complications and postoperative results of the three periods were compared. RESULTS: Mean follow-up was 1 year. Preoperative patients' characteristics were homogeneous. No significant differences have been registered among the three periods concerning operative data, mortality, intra- and post-operative complications, weight loss outcomes and comorbidities' resolution. Post-operative follow-up rates at 6 and 12 months were 98.4 and 92.1 %, respectively. CONCLUSIONS: Long-lasting fellowship in a HVBC might allow the novel bariatric surgeon to safely and proficiently overcome the LC for SG, even in a new established bariatric setting.


Asunto(s)
Gastrectomía/educación , Laparoscopía/educación , Curva de Aprendizaje , Obesidad Mórbida/cirugía , Adulto , Femenino , Gastrectomía/métodos , Humanos , Italia , Laparoscopía/métodos , Masculino , Complicaciones Posoperatorias , Resultado del Tratamiento , Pérdida de Peso , Adulto Joven
3.
BMC Surg ; 15: 54, 2015 May 03.
Artículo en Inglés | MEDLINE | ID: mdl-25935155

RESUMEN

BACKGROUND: The rising interest towards minimally invasive surgery has led to the introduction of laparo-endoscopic single site (LESS) surgery as the natural evolution of conventional multiport laparoscopy. However, this new surgical approach is hampered with peculiar technical difficulties. The SPIDER surgical system has been developed in the attempt to overcome some of these challenges. Our study aimed to compare standard laparoscopy and SPIDER technical performance on a surgical simulator, using standardized tasks from the Fundamentals of Laparoscopic Surgery (FLS). METHODS: Twenty participants were divided into two groups based on their surgical laparoscopic experience: 10 PGY1 residents were included in the inexperienced group and 10 laparoscopists in the experienced group. Participants performed the FLS pegboard transfers task and pattern cutting task on a laparoscopic box trainer. Objective task scores and subjective questionnaire rating scales were used to compare conventional laparoscopy and SPIDER surgical system. RESULTS: Both groups performed significantly better in the FLS scores on the standard laparoscopic simulator compared to the SPIDER. Inexperienced group: Task 1 scores (median 252.5 vs. 228.5; p = 0.007); Task 2 scores (median 270.5 vs. 219.0; p = 0.005). Experienced group: Task 1 scores (median 411.5 vs. 309.5; p = 0.005); Task 2 scores (median 418.0 vs. 331.5; p = 0.007). Same aspects were highlighted for the subjective evaluations, except for the inexperienced surgeons who found both devices equivalent in terms of ease of use only in the peg transfer task. CONCLUSIONS: Even though the SPIDER is an innovative and promising device, our study proved that it is more challenging than conventional laparoscopy in a population with different degrees of surgical experience. We presume that a possible way to overcome such challenges could be the development of tailored training programs through simulation methods. This may represent an effective way to deliver training, achieve mastery and skills and prepare surgeons for their future clinical experience.


Asunto(s)
Competencia Clínica , Laparoscopía/instrumentación , Entrenamiento Simulado , Adulto , Humanos , Laparoscopía/educación , Laparoscopía/métodos , Ciudad de Roma
4.
Surg Endosc ; 28(1): 242-8, 2014 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-23996341

RESUMEN

BACKGROUND: Construct validity of virtual laparoscopic simulators for basic laparoscopic skills has been proposed; however, it is not yet clear whether the simulators can identify the actual experience of surgeons in more complex procedures such as laparoscopic Roux-en-Y gastric bypass. This study tested the ability of the Lap Mentor simulator to recognize the experience in advanced laparoscopic procedures and to assess its role in the certification of bariatric surgeons. METHODS: Twenty surgeons were divided into two groups according to their experience in laparoscopic and bariatric surgery. The general group included 10 general surgeons performing between 75 and 100 nonbariatric laparoscopic procedures. The bariatric group included 10 bariatric surgeons performing between 50 and 100 laparoscopic bariatric procedures. Participants were tested on the simulator in one basic task (task 1: eye-hand coordination) and in two tasks of the gastric bypass module (task 2: creation of the gastric pouch; task 3: gastrojejunal anastomosis). RESULTS: Comparing the groups, no significant differences were found in task 1. Analyzing the results from the gastric bypass module (bariatric vs. general), in task 2, significant differences (p < 0.05) were found in the median volume of the gastric pouch (21 vs. 48 cm(3)), in the percentage of fundus included in the pouch (8.4 vs. 29.4 %), in the complete dissection at the angle of His (10 vs. 3), and in safety parameters. In task 3, significant differences were found in the size and position of enterotomies. CONCLUSIONS: The Lap Mentor may be proposed as a certification tool for bariatric surgeons because it also recognizes their specific skills in the technical details of the procedure that affect long-term results. Furthermore, the possibility of analyzing the performance in detail can help define areas where the surgeon is lacking. These findings indicate a potential role of the Lap Mentor in tailoring the training to maximize improvement.


Asunto(s)
Cirugía Bariátrica/educación , Certificación , Simulación por Computador , Educación Médica Continua/normas , Terapia de Exposición Mediante Realidad Virtual/educación , Adulto , Anastomosis Quirúrgica/educación , Competencia Clínica , Disección/educación , Femenino , Humanos , Italia , Laparoscopía/educación , Masculino , Persona de Mediana Edad , Desempeño Psicomotor , Análisis y Desempeño de Tareas , Interfaz Usuario-Computador , Terapia de Exposición Mediante Realidad Virtual/normas
6.
Insights Imaging ; 5(6): 691-6, 2014 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-25249333

RESUMEN

Renal colic is the most frequent nonobstetric cause for abdominal pain and subsequent hospitalization during pregnancy. The physio-anatomical changes in the urinary tract and the presence of the fetus may complicate the clinical presentation and management of nephrolithiasis. Ultrasound (US) is the primary radiological investigation of choice. Magnetic resonance urography (MRU) and low-dose computed tomography (CT) have to be considered as a second- and third-line test, respectively. If a study that uses ionizing radiation has to be performed, the radiation dose to the fetus should be as low as possible. The initial management of symptomatic ureteric stones is conservative during pregnancy. Intervention will be necessary in patients who do not respond to conservative measures. Therefore, it is crucial to obtain a prompt and accurate diagnosis to optimize the management of these patients. Teaching Points • In pregnancy, renal colic is the most frequent nonobstetric cause for abdominal pain and hospitalization. • Magnetic resonance urography should be considered when ultrasound is nondiagnostic. • Low-dose CT should be considered as a last-line test during pregnancy.

7.
World J Gastroenterol ; 20(29): 9998-10007, 2014 Aug 07.
Artículo en Inglés | MEDLINE | ID: mdl-25110428

RESUMEN

The development of ultrasound contrast agents with excellent tolerance and safety profiles has notably improved liver evaluation with ultrasound (US) for several applications, especially for the detection of metastases. In particular, contrast enhanced ultrasonography (CEUS) allows the display of the parenchymal microvasculature, enabling the study and visualization of the enhancement patterns of liver lesions in real time and in a continuous manner in all vascular phases, which is similar to contrast-enhanced computed tomography (CT) and contrast-enhanced magnetic resonance imaging. Clinical studies have reported that the use of a contrast agent enables the visualization of more metastases with significantly improved sensitivity and specificity compared to baseline-US. Furthermore, studies have shown that CEUS yields sensitivities comparable to CT. In this review, we describe the state of the art of CEUS for detecting colorectal liver metastases, the imaging features, the literature reports of metastases in CEUS as well as its technique, its clinical role and its potential applications. Additionally, the updated international consensus panel guidelines are reported in this review with the inherent limitations of this technique and best practice experiences.


Asunto(s)
Medios de Contraste , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/secundario , Imagen por Resonancia Magnética , Tomografía Computarizada por Rayos X , Humanos , Neoplasias Hepáticas/terapia , Valor Predictivo de las Pruebas , Pronóstico , Ultrasonografía
8.
PLoS One ; 8(8): e72224, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-23977259

RESUMEN

Fibroblast growth factor receptor-2 (FGFR-2) plays an important role in tumorigenesis. In thyroid cancer it has been observed a FGFR-2 down-modulation, but the role of this receptor has not been yet clarified. Therefore, we decided to examine the expression of both FGFR-2 isoform, FGFR-2-IIIb and FGFR-2-IIIc, in different histological thyroid variants such as hyperplasia, follicular adenoma and papillary carcinoma. Immunohistochemistry and quantitative Real-Time PCR analyses were performed on samples of hyperplasia, follicular adenoma and papillary carcinoma, compared with normal thyroid tissue. Thyroid hyperplasia did not show statistically significant reduction in FGFR-2 protein and mRNA levels. Interestingly, in both follicular adenoma and papillary carcinoma samples we observed a strongly reduced expression of both FGFR-2 isoforms. We speculate that FGFR-2 down-modulation might be an early event in thyroid carcinogenesis. Furthermore, we suggest the potential use of FGFR-2 as an early marker for thyroid cancer diagnosis.


Asunto(s)
Adenoma/genética , Biomarcadores de Tumor/genética , Carcinoma Papilar/genética , Regulación Neoplásica de la Expresión Génica , ARN Mensajero/genética , Receptor Tipo 2 de Factor de Crecimiento de Fibroblastos/genética , Neoplasias de la Tiroides/genética , Adenoma/diagnóstico , Adenoma/metabolismo , Adenoma/patología , Adulto , Anciano , Biomarcadores de Tumor/metabolismo , Carcinogénesis/genética , Carcinogénesis/metabolismo , Carcinogénesis/patología , Carcinoma Papilar/diagnóstico , Carcinoma Papilar/metabolismo , Carcinoma Papilar/patología , Femenino , Humanos , Hiperplasia/diagnóstico , Hiperplasia/genética , Hiperplasia/metabolismo , Hiperplasia/patología , Masculino , Persona de Mediana Edad , Isoformas de Proteínas/genética , Isoformas de Proteínas/metabolismo , ARN Mensajero/metabolismo , Receptor Tipo 2 de Factor de Crecimiento de Fibroblastos/metabolismo , Transducción de Señal , Glándula Tiroides/metabolismo , Glándula Tiroides/patología , Neoplasias de la Tiroides/diagnóstico , Neoplasias de la Tiroides/metabolismo , Neoplasias de la Tiroides/patología
9.
Tumori ; 99(3): e84-7, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-24158087

RESUMEN

Metastatic carcinomas to the thyroid are rare in daily clinical practice. However, when encountered they represent a diagnostic challenge, since it is difficult to distinguish them from primary thyroid lesions, especially when occurring in patients with occult malignant history. Nevertheless, it is critical to differentiate a metastatic tumor from primary thyroid lesions, as the clinical management and the prognosis are different for the two entities. More recently, elastosonography opened new possibilities to ultrasound in different fields, such as thyroid nodule differentiation. Herein, we report a case of metastatic signet ring cell carcinoma to the thyroid studied with quantitative elastography and acoustic radiation force impulse imaging.


Asunto(s)
Carcinoma de Células en Anillo de Sello/diagnóstico por imagen , Carcinoma de Células en Anillo de Sello/secundario , Diagnóstico por Imagen de Elasticidad/métodos , Neoplasias de Cabeza y Cuello/diagnóstico por imagen , Neoplasias de Cabeza y Cuello/patología , Nódulo Tiroideo/diagnóstico por imagen , Biopsia con Aguja Fina , Diagnóstico Diferencial , Resultado Fatal , Humanos , Masculino , Persona de Mediana Edad , Tomografía Computarizada por Rayos X
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA