Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Bases de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Tree Physiol ; 43(8): 1467-1477, 2023 08 11.
Artículo en Inglés | MEDLINE | ID: mdl-37084133

RESUMEN

The accurate estimation of plant transpiration is critical to the fields of hydrology, plant physiology and ecology. Among the various methods of measuring transpiration in the field, the sap flow methods based on head pulses offers a cost-effective and energy-efficient option to directly measure the plant-level movement of water through the hydraulically active tissue. While authors have identified several possible sources of error in these measurements, one of the most common sources is misalignment of the sap flow probes due to user error. Though the effects of probe misalignment are well documented, no device or technique has been universally adopted to ensure the proper installation of sap flow probes. In this paper we compare the magnitude of misalignment errors among a 5 mm thick drilling template (DT), a 10 mm thick DT, and a custom designed, field-portable drill press. The different techniques were evaluated in the laboratory using a 7.5 cm wood block and in the field, comparing differences in measured sap flow. Based on analysis of holes drilled in the wood block, we found that the portable drill press was most effective in assuring that drill holes remained parallel, even at 7.5 cm depth. In field installations, nearly 50% of holes drilled with a 5 mm template needed to be redrilled while none needed to be when drilled with the drill press. Widespread use of a portable drill press when implementing the heat pulse method would minimize alignment uncertainty and allow a clearer understanding of other sources of uncertainty due to variability in tree species, age, or external drivers or transpiration.


Asunto(s)
Ecología , Hidrología , Transporte Biológico , Transpiración de Plantas , Árboles
2.
HardwareX ; 12: e00351, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-36117543

RESUMEN

Accurate estimation of transpiration in individual trees is important for understanding plant responses to environmental drivers, closing the water balance in forest stands and catchments, and calibrating earth system models, among other applications. However, the cost and power consumption of commercial systems based on sap flow methods still limit their usage. We developed and tested a cost-effective (<$150), simple to construct, and energy efficient sap flux device based on the heat pulse method. Energy savings were achieved by reducing the voltage of heat pulses and using an internal clock to completely shut down the device between pulses. Device accuracy was confirmed by laboratory estimates of sap flow made on excised branches of Acer saccharum and Tsuga canadensis (adjusted R2 = 0.96). In a 174-d field installation of 12 devices, batteries (eight rechargeable Ni-MH AA) needed to be replaced every 14 days. Sap flux measurements in the field tracked expected variations in vapor pressure deficit and tree phenology. The low cost, compact design, reliability, and power consumption of this device enable sap flux studies to operate with more replication and in more diverse ecological settings than has been practical in the past.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA