Importance: The benefit of high-flow nasal cannula oxygen (high-flow oxygen) in terms of intubation and mortality in patients with respiratory failure due to COVID-19 is controversial. Objective: To determine whether the use of high-flow oxygen, compared with standard oxygen, could reduce the rate of mortality at day 28 in patients with respiratory failure due to COVID-19 admitted in intensive care units (ICUs). Design, Setting, and Participants: The SOHO-COVID randomized clinical trial was conducted in 34 ICUs in France and included 711 patients with respiratory failure due to COVID-19 and a ratio of partial pressure of arterial oxygen to fraction of inspired oxygen equal to or below 200 mm Hg. It was an ancillary trial of the ongoing original SOHO randomized clinical trial, which was designed to include patients with acute hypoxemic respiratory failure from all causes. Patients were enrolled from January to December 2021; final follow-up occurred on March 5, 2022. Interventions: Patients were randomly assigned to receive high-flow oxygen (n = 357) or standard oxygen delivered through a nonrebreathing mask initially set at a 10-L/min minimum (n = 354). Main Outcomes and Measures: The primary outcome was mortality at day 28. There were 13 secondary outcomes, including the proportion of patients requiring intubation, number of ventilator-free days at day 28, mortality at day 90, mortality and length of stay in the ICU, and adverse events. Results: Among the 782 randomized patients, 711 patients with respiratory failure due to COVID-19 were included in the analysis (mean [SD] age, 61 [12] years; 214 women [30%]). The mortality rate at day 28 was 10% (36/357) with high-flow oxygen and 11% (40/354) with standard oxygen (absolute difference, -1.2% [95% CI, -5.8% to 3.4%]; P = .60). Of 13 prespecified secondary outcomes, 12 showed no significant difference including in length of stay and mortality in the ICU and in mortality up until day 90. The intubation rate was significantly lower with high-flow oxygen than with standard oxygen (45% [160/357] vs 53% [186/354]; absolute difference, -7.7% [95% CI, -14.9% to -0.4%]; P = .04). The number of ventilator-free days at day 28 was not significantly different between groups (median, 28 [IQR, 11-28] vs 23 [IQR, 10-28] days; absolute difference, 0.5 days [95% CI, -7.7 to 9.1]; P = .07). The most common adverse events were ventilator-associated pneumonia, occurring in 58% (93/160) in the high-flow oxygen group and 53% (99/186) in the standard oxygen group. Conclusions and Relevance: Among patients with respiratory failure due to COVID-19, high-flow nasal cannula oxygen, compared with standard oxygen therapy, did not significantly reduce 28-day mortality. Trial Registration: ClinicalTrials.gov Identifier: NCT04468126.
Asunto(s)
COVID-19 , Terapia por Inhalación de Oxígeno , Insuficiencia Respiratoria , COVID-19/complicaciones , COVID-19/mortalidad , COVID-19/terapia , Cánula/efectos adversos , Femenino , Humanos , Masculino , Máscaras , Persona de Mediana Edad , Oxígeno/administración & dosificación , Terapia por Inhalación de Oxígeno/efectos adversos , Insuficiencia Respiratoria/etiología , Insuficiencia Respiratoria/mortalidad , Insuficiencia Respiratoria/terapiaRESUMEN
INTRODUCTION: First-line oxygenation strategy in patients with acute hypoxaemic respiratory failure consists in standard oxygen or high-flow nasal oxygen therapy. Clinical practice guidelines suggest the use of high-flow nasal oxygen rather than standard oxygen. However, findings remain contradictory with a low level of certainty. We hypothesise that compared with standard oxygen, high-flow nasal oxygen may reduce mortality in patients with acute hypoxaemic respiratory failure. METHOD AND ANALYSIS: The Standard Oxygen versus High-flow nasal Oxygen-trial is an investigator-initiated, multicentre, open-label, randomised controlled trial comparing high-flow nasal oxygen versus standard oxygen in patients admitted to an intensive care unit (ICU) for acute respiratory failure with moderate-to-severe hypoxaemia. 1110 patients will be randomly assigned to one of the two groups with a ratio of 1:1. The primary outcome is the number of patients who died 28 days after randomisation. Secondary outcomes include comfort, dyspnoea and oxygenation 1 hour after treatment initiation, the number of patients intubated at day 28, mortality in ICU, in hospital and until day 90, and complications during ICU stay. ETHICS AND DISSEMINATION: The study has been approved by the central Ethics Committee 'Sud Méditerranée III' (2020-07-05) and patients will be included after informed consent. The results will be submitted for publication in peer-reviewed journals. TRIAL REGISTRATION NUMBER: NCT04468126.
Asunto(s)
Cánula , Terapia por Inhalación de Oxígeno , Insuficiencia Respiratoria , Humanos , Terapia por Inhalación de Oxígeno/métodos , Insuficiencia Respiratoria/terapia , Insuficiencia Respiratoria/mortalidad , Ensayos Clínicos Controlados Aleatorios como Asunto , Hipoxia/terapia , Hipoxia/mortalidad , Estudios Multicéntricos como Asunto , Unidades de Cuidados Intensivos , Oxígeno/administración & dosificación , Enfermedad AgudaRESUMEN
In this study, we report a complete (clinical, radiological, and virological) sustained (1 year) response after nivolumab salvage therapy in a progressive multifocal leukoencephalopathy patient. Analyses of the cells infiltrate in a pretreatment brain biopsy suggest that parenchymal programmed cell death-L1+ macrophages could be the T-cells partnership in immune exhaustion and virus escape.