Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 30
Filtrar
1.
BMC Cancer ; 24(1): 174, 2024 Feb 05.
Artículo en Inglés | MEDLINE | ID: mdl-38317104

RESUMEN

BACKGROUND: High levels of physical activity are associated with reduced risk of the blood cancer multiple myeloma (MM). MM is preceded by the asymptomatic stages of monoclonal gammopathy of undetermined significance (MGUS) and smouldering multiple myeloma (SMM) which are clinically managed by watchful waiting. A case study (N = 1) of a former elite athlete aged 44 years previously indicated that a multi-modal exercise programme reversed SMM disease activity. To build from this prior case study, the present pilot study firstly examined if short-term exercise training was feasible and safe for a group of MGUS and SMM patients, and secondly investigated the effects on MGUS/SMM disease activity. METHODS: In this single-arm pilot study, N = 20 participants diagnosed with MGUS or SMM were allocated to receive a 16-week progressive exercise programme. Primary outcome measures were feasibility and safety. Secondary outcomes were pre- to post-exercise training changes to blood biomarkers of MGUS and SMM disease activity- monoclonal (M)-protein and free light chains (FLC)- plus cardiorespiratory and functional fitness, body composition, quality of life, blood immunophenotype, and blood biomarkers of inflammation. RESULTS: Fifteen (3 MGUS and 12 SMM) participants completed the exercise programme. Adherence was 91 ± 11%. Compliance was 75 ± 25% overall, with a notable decline in compliance at intensities > 70% V̇O2PEAK. There were no serious adverse events. There were no changes to M-protein (0.0 ± 1.0 g/L, P =.903), involved FLC (+ 1.8 ± 16.8 mg/L, P =.839), or FLC difference (+ 0.2 ± 15.6 mg/L, P =.946) from pre- to post-exercise training. There were pre- to post-exercise training improvements to diastolic blood pressure (- 3 ± 5 mmHg, P =.033), sit-to-stand test performance (+ 5 ± 5 repetitions, P =.002), and energy/fatigue scores (+ 10 ± 15%, P =.026). Other secondary outcomes were unchanged. CONCLUSIONS: A 16-week progressive exercise programme was feasible and safe, but did not reverse MGUS/SMM disease activity, contrasting a prior case study showing that five years of exercise training reversed SMM in a 44-year-old former athlete. Longer exercise interventions should be explored in a group of MGUS/SMM patients, with measurements of disease biomarkers, along with rates of disease progression (i.e., MGUS/SMM to MM). REGISTRATION: https://www.isrctn.com/ISRCTN65527208 (14/05/2018).


Asunto(s)
Gammopatía Monoclonal de Relevancia Indeterminada , Mieloma Múltiple , Paraproteinemias , Mieloma Múltiple Quiescente , Humanos , Adulto , Gammopatía Monoclonal de Relevancia Indeterminada/terapia , Gammopatía Monoclonal de Relevancia Indeterminada/diagnóstico , Mieloma Múltiple/diagnóstico , Proyectos Piloto , Calidad de Vida , Progresión de la Enfermedad , Biomarcadores , Ejercicio Físico
2.
Biochim Biophys Acta ; 1527(1-2): 11-9, 2001 Jul 02.
Artículo en Inglés | MEDLINE | ID: mdl-11420138

RESUMEN

Measurements of bone mineral content and composition in situ provide insight into the chemistry of bone mineral deposition. Infrared (IR) micro-spectroscopy is well suited for this purpose. To date, IR microscopic (including imaging) analyses of bone apatite have centered on the nu(1),nu(3) PO(4)(3-) contour. The nu(4) PO(4)(3-) contour (500-650 cm(-1)), which has been extensively used to monitor the crystallinity of hydroxyapatite in homogenized bone samples, falls in a frequency region below the cutoff of the mercury-cadmium-telluride detectors used in commercial IR microscopes, thereby rendering this vibration inaccessible for imaging studies. The current study reports the first IR micro-spectroscopy spectra of human iliac crest cross sections in the nu(4) PO(4)(3-) spectral regions, obtained with a synchrotron radiation source and a Cu-doped Ge detector coupled to an IR microscope. The acid phosphate (HPO(4)(2-)) content and mineral crystallite perfection (crystallinity) of a human osteon were mapped. To develop spectra-structure correlations, a combination of X-ray powder diffraction data and conventional Fourier transform IR spectra have been obtained from a series of synthetic hydroxyapatite crystals and natural bone powders of various species and ages. X-ray powder diffraction data demonstrate that there is an increase in average crystal size as bone matures, which correlates with an increase in the nu(4) PO(4)(3-) FTIR absorption peak ratio of two peaks (603/563 cm(-1)) within the nu(4) PO(4)(3-) contour. Additionally, the IR results reveal that a band near 540 cm(-1) may be assigned to acid phosphate. This band is present at high concentrations in new bone, and decreases as bone matures. Correlation of the nu(4) PO(4)(3-) contour with the nu(2) CO (3)(2-) contour also reveals that when acid phosphate content is high, type A carbonate content (i.e., carbonate occupying OH(-) sites in the hydroxyapatite lattice) is high. As crystallinity increases and acid phosphate content decreases, carbonate substitution shifts toward occupation of PO(4)(3-) sites in the hydroxyapatite lattice. Thus, IR microscopic analysis of the nu(4) PO(4)(3-) contour provides a straightforward index of both relative mineral crystallinity and acid phosphate concentration that can be applied to in situ IR micro-spectroscopic analysis of bone samples, which are of interest for understanding the chemical mechanisms of bone deposition in normal and pathological states.


Asunto(s)
Huesos/química , Minerales/análisis , Adulto , Animales , Densidad Ósea , Humanos , Masculino , Ratones , Conejos , Espectrofotometría Infrarroja/métodos , Difracción de Rayos X
3.
J Bone Joint Surg Am ; 76(7): 1052-6, 1994 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-8027113

RESUMEN

A study was performed to determine the time-course of oxidative degradation and the extent to which the degradation proceeded through the bulk of ultra-high molecular weight polyethylene joint components that had been irradiated and stored on a shelf. Standardized cylindrical samples, taken from a single batch of extruded polyethylene, were cleaned, packaged, and sterilized according to protocols used for commercial joint-replacement components. After sterilization, the samples were stored in the packages for time-periods of one day to more than one year. At each interval studied, thin sections were cut as a function of depth into the bulk of the sample and were used to determine the density and the infrared spectra. Marked alterations in the density and the infrared spectra consistent with continuing oxidative degradation occurred throughout the year of storage on the shelf. The alterations were most severe near the surface of the samples.


Asunto(s)
Polietilenos/metabolismo , Estabilidad de Medicamentos , Almacenaje de Medicamentos , Rayos gamma/efectos adversos , Humanos , Prótesis Articulares , Oxidación-Reducción , Polietilenos/efectos de la radiación , Esterilización/métodos , Factores de Tiempo
4.
J Bone Joint Surg Am ; 66(8): 1289-93, 1984 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-6490705

RESUMEN

In an effort to define and characterize the initial mineralization product of fracture-healing, we studied the mineral components within a model of endochondral osseous repair. Fracture calluses from the tibiae of rats and rabbits undergoing endochondral fracture-healing were analyzed, in toto and following density fractionation, by physicochemical and crystallographic techniques. Significant changes in mineral composition, crystal size, and density occurred in the early phases of fracture repair. In the rat, two weeks after fracture, the calcium-to-phosphorus ratio was higher than that of the mineral component, possibly due to calcium-binding to some of the macromolecules known to be present. The earliest mineral was poorly crystallized hydroxyapatite with a high carbonate content. Crystal perfection improved rapidly and approached that of normal diaphyseal bone within eight weeks after endochondral fracture in both the rabbit and the rat.


Asunto(s)
Minerales/metabolismo , Fracturas de la Tibia/metabolismo , Animales , Callo Óseo/análisis , Callo Óseo/metabolismo , Moldes Quirúrgicos , Cristalización , Minerales/análisis , Conejos , Ratas , Ratas Endogámicas , Factores de Tiempo , Cicatrización de Heridas , Difracción de Rayos X
5.
Spine (Phila Pa 1976) ; 24(9): 899-903, 1999 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-10327512

RESUMEN

STUDY DESIGN: A prospective study of tissue surrounding spinal instrumentation was performed using histologic and chemical analysis. OBJECTIVES: To identify and quantify the amount of metal debris generated by titanium pedicle screw instrumentation and to evaluate the histologic response in the spinal tissues. SUMMARY OF BACKGROUND DATA: Microscopic metal particles from the soft tissue surrounding joint arthroplasties have been shown to activate a macrophage response that leads to bone resorption and increased inflammation. The use of titanium spinal implants for spine surgery projects the possibility of generating wear debris in the spine. METHODS: Nine patients with titanium instrumentation from a prior lumbar decompression and fusion procedure who were undergoing reoperation were entered into this study. Tissue samples were collected from areas near the pedicle screw-rod junction, the scar tissue overlying the dura, and the pedicle screw holes. Metal levels for titanium were determined by electrothermal atomic absorption spectroscopy, and histologic analysis was performed by light and electron microscopy. RESULTS: Tissue concentrations of titanium were highest in patients with a pseudarthrosis (30.36 micrograms/g of dry tissue). Patients with a solid fusion had low concentrations of titanium (0.586 microgram/g of dry tissue). Standard light microscopy identified metal particles in the soft tissues. Transmission electron microscopy demonstrated macrophages with numerous secondary lysosomes containing electron-dense bodies and collagenous stroma with electron-dense rod-like profiles consistent with metal debris. CONCLUSIONS: Wear debris is generated by the use of titanium spinal instrumentation in patients with a pseudarthrosis. These particles activate a macrophage cellular response in the spinal tissues similar to that seen in surrounding joint prostheses. Patients with a solid spinal fusion have negligible levels of particulate matter.


Asunto(s)
Materiales Biocompatibles , Cuerpos Extraños/etiología , Fusión Vertebral/instrumentación , Titanio , Materiales Biocompatibles/análisis , Tornillos Óseos , Tejido Conectivo/química , Tejido Conectivo/diagnóstico por imagen , Tejido Conectivo/ultraestructura , Femenino , Cuerpos Extraños/metabolismo , Cuerpos Extraños/patología , Humanos , Vértebras Lumbares/cirugía , Región Lumbosacra/diagnóstico por imagen , Región Lumbosacra/patología , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Seudoartrosis/patología , Seudoartrosis/cirugía , Radiografía , Espectrofotometría Atómica , Titanio/análisis
6.
J Bone Joint Surg Br ; 76(4): 568-74, 1994 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-8027142

RESUMEN

We report a prospective study of the liner-metal interfaces of modular uncemented acetabular components as sources of debris. We collected the pseudomembrane from the screw-cup junction and the empty screw holes of the metal backing of 19 acetabula after an average implantation of 22 months. Associated osteolytic lesions were separately collected in two cases. The back surfaces of the liners and the screws were examined for damage, and some liners were scanned by electron microscopy. The tissues were studied histologically and by atomic absorption spectrophotometry to measure titanium content. The pseudomembrane from the screw-cup junction contained polyethylene debris in seven specimens and metal debris in ten. The material from empty screw holes was necrotic tissue or dense fibroconnective tissue with a proliferative histiocytic infiltrate and foreign-body giant-cell reaction. It contained polyethylene debris in 14 cases and metal in five. The two acetabular osteolytic lesions also showed a foreign-body giant-cell reaction to particulate debris. The average titanium levels in pseudomembranes from the screw-cup junction and the empty screw holes were 959 micrograms/g (48 to 11,900) and 74 micrograms/g (0.72 to 331) respectively. The tissue from the two lytic lesions showed average titanium levels of 139 and 147 micrograms/g respectively. The back surfaces of the PE liners showed surface deformation, burnishing, and embedded metal debris. All 30 retrieved screws demonstrated fretting at the base of the head and on the proximal shaft. Non-articular modular junctions create new interfaces for the generation of particulate debris, which may cause granulomatous reaction.


Asunto(s)
Prótesis de Cadera/efectos adversos , Metales/análisis , Polietilenos/análisis , Acetábulo , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Osteólisis/etiología , Complicaciones Posoperatorias , Estudios Prospectivos
7.
J Bone Joint Surg Br ; 74(3): 380-4, 1992 May.
Artículo en Inglés | MEDLINE | ID: mdl-1587882

RESUMEN

Reports of differing failure rates of total hip prostheses made of various metals prompted us to measure the size of metallic and polyethylene particulate debris around failed cemented arthroplasties. We used an isolation method, in which metallic debris was extracted from the tissues, and a non-isolation method of routine preparation for light and electron microscopy. Specimens were taken from 30 cases in which the femoral component was of titanium alloy (10), cobalt-chrome alloy (10), or stainless steel (10). The mean size of metallic particles with the isolation method was 0.8 to 1.0 microns by 1.5 to 1.8 microns. The non-isolation method gave a significantly smaller mean size of 0.3 to 0.4 microns by 0.6 to 0.7 microns. For each technique the particle sizes of the three metals were similar. The mean size of polyethylene particles was 2 to 4 microns by 8 to 13 microns. They were larger in tissue retrieved from failed titanium-alloy implants than from cobalt-chrome and stainless-steel implants. Our results suggest that factors other than the size of the metal particles, such as the constituents of the alloy, and the amount and speed of generation of debris, may be more important in the failure of hip replacements.


Asunto(s)
Prótesis de Cadera , Metales/análisis , Polietilenos/análisis , Aleaciones de Cromo/análisis , Articulación de la Cadera/química , Humanos , Microscopía Electrónica , Tamaño de la Partícula , Falla de Prótesis , Acero Inoxidable/análisis , Titanio/análisis
8.
Orthopedics ; 16(11): 1277-81, 1993 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-8290404

RESUMEN

Wear debris has evolved as the primary etiology of mechanical loosening of cemented as well as uncemented total hip arthroplasty. Osteolysis results from particle formation, and this has been most commonly reported to be secondary to polyethylene wear debris. This article demonstrates that metallic particle debris will also result in significant osteolysis. The two sources in this case are cobalt-chromium (Co-Cr) particles from the acetabular component and titanium-alloy (Ti) particles from the Morse taper junction and the Ti-alloy femoral head. However, it is likely that polyethylene debris also contributed to the osteolysis, because a titanium head was used and we know this results in increased poly wear.


Asunto(s)
Cuerpos Extraños/complicaciones , Prótesis de Cadera/efectos adversos , Osteólisis/etiología , Adulto , Femenino , Cuerpos Extraños/etiología , Humanos , Falla de Prótesis
13.
Clin Orthop Relat Res ; (293): 160-73, 1993 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-8339477

RESUMEN

Several studies conducted by the authors in the last six years demonstrate that the generation of metallic debris is more severe with titanium alloy than with cobalt-chrome alloy femoral components in cemented total hip arthroplasty (THA). The debris is generated from the articulating surface, particularly if entrapped acrylic debris produces three-body wear, and from the stem surface when the component loosens and abrades against fragmented cement. In selected cases in which the titanium metallic debris is copious, premature failure and severe progressive bone loss occurs. Electron microscopy demonstrates that the particles of metallic debris can be extremely small (a few hundredths of 1 micron). They are phagocytized by the macrophages and transported to the phagolysosomes. In this highly corrosive environment, the very high surface area of the particles may release toxic concentrations of the constituents of the alloy intracellularly, probably leading to progressive cell degeneration and death, with subsequent release of intracellular enzymes and ingested metallic debris. This cycle most likely repeats itself, leading to tissue necrosis. The results presented do not support the use of titanium alloy femoral components for cemented THA, particularly for the articulating surface.


Asunto(s)
Cementos para Huesos , Aleaciones de Cromo , Prótesis de Cadera , Polietilenos , Acero Inoxidable , Titanio , Aleaciones , Tejido Conectivo/patología , Cadera/patología , Humanos , Microscopía Electrónica , Diseño de Prótesis , Falla de Prótesis , Líquido Sinovial/química
14.
Calcif Tissue Int ; 33(2): 111-7, 1981.
Artículo en Inglés | MEDLINE | ID: mdl-6260311

RESUMEN

When amorphous calcium phosphate (ACP) was transformed to crystalline hydroxyapatite (HA) in a series of aqueous slurry concentrations ranging from low to high, the higher slurry concentrations produced more Ca-deficient HA as measured by Ca/P ratio and heat-produced pyrophosphate. We feel that the excess solution phosphate produced in the higher slurry transformations results in lower Ca/P ratio HA. It has been suggested that an ACP is the precursor to bone apatite. Regulation of the in vivo ACP slurry concentration could then control the stoichiometry and, therefore, the metabolic activity of bone apatite. X-ray radial distribution function (RDF) analyses showed that CO3(2-) substitution in HA creates far greater structural distortions than do Ca deficiencies. The latter, however, do produce small, but observable, structural distortions when compared to stoichiometric HA. It now seems clear that the RDF of bone apatite can be modeled by a synthetic, Ca-deficient, CO3(2-)-containing HA.


Asunto(s)
Calcio , Hidroxiapatitas , Fosfatos de Calcio , Cristalografía , Difosfatos/análisis , Conformación Molecular
15.
Calcif Tissue Res ; 18(2): 81-90, 1975 Jul 25.
Artículo en Inglés | MEDLINE | ID: mdl-1148899

RESUMEN

Amorphous calcium phosphate (ACP) was transformed at 25 degrees to hydroxyapatite (HA) in horse and bovine serum; solutions of serum-protein fractions in tris-HC1 buffer (pH 7.4), and pH 7.4 buffers containing from 0.1 to 10 times physiological CO3(2-) concentration. The ACP-to-HA transformation was slower in whole serum and serum fractions than in control buffer solution. The observed adsorption of serum proteins on ACP and HA probably inhibits both the dissolution of the ACP particles and the growth of HA crystals. After 72 h all transformations were complete as determined by X-ray diffraction. The HA crystal dimensions decreased with increasing C03(2-) but the shape, as shown by X-ray linewidths, was relatively constant up to about 4% CO3(2-). At 15% CO3(2-) the crystals were more equiaxial and less needle-like in habit. The radial distribution function (RDF) of HA with 3.7% CO3(2-) is less well resolved than the RDF of HA with ambient CO3(2-) (1.1%). The peaks are less sharp and their amplitude falls more rapidly with increasing atomic separation than for low CO3(2-)-HA. These effects show that CO3(2-) decreases the regularity of the atomic arrangement when incorporated in HA. The rapid decrease, with increasing CO3(2-) content, of the IR splitting of the P-O bending mode of CO3(2-)-HA is attributed to reduced crystal size and possibly to a perturbation of the crystal field due to CO3(2-)-induced lattice distortion. Finally, for bone mineral, it is probable that the poor resolution of the X-ray and IR patterns is due, in large part, to small crystal size and internal disorder caused by CO3(2-).


Asunto(s)
Proteínas Sanguíneas , Carbonatos , Hidroxiapatitas , Adsorción , Animales , Biopolímeros , Sangre , Fosfatos de Calcio , Bovinos , Cristalización , Caballos , Albúmina Sérica , Seroglobulinas , Espectrofotometría Infrarroja , Trometamina , Difracción de Rayos X
16.
Ann Periodontol ; 5(1): 175-84, 2000 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-11885178

RESUMEN

The stability of thermally processed hydroxyapatite coatings for oral and orthopedic bioprostheses has been questioned. Information on the chemical changes, which occur with hydroxyapatite biomaterials post-implantation in humans, is lacking. The purpose of this investigation was to begin to examine post-implantation surface changes of hydroxyapatite-coated implants using scanning electron microscopy (SEM), x-ray microanalysis (EDAX), Fourier transform infrared spectroscopy (FTIR), and x-ray diffraction (XRD). Three retrieved dental implant specimens from humans following clinical failure due to peri-implantitis were examined. Unimplanted cylinders served as controls. Clinically, the retrieved specimens were all enveloped by a fibrous tissue capsule with bone present at the apical extent of the implant. SEM analysis showed that the retrieved surfaces were coated with both calcified and proteinaceous deposits. EDAX scans of the retrieved specimens demonstrated evidence of hydroxyapatite coating loss reflected by increasing titanium and aluminum signals. Other foreign ions such as sodium, chloride, sulfur, silica, and magnesium were detected. XRD of the control specimens showed that the samples were predominantly apatite; however, two peaks were detected in the diffraction pattern, which are not characteristic of hydroxyapatite, indicating that small amounts of one or more other crystalline phases were also present. The retrieved specimens showed slightly larger average crystal size relative to the control sample material, and the non-apatite lines were not present. FTIR evaluation of the retrieved specimens revealed the incorporation of carbonate and organic matrix on or into the hydroxyapatite. Narrowing of and increased detail in the phosphate peaks indicated an increase in average crystal size and/or perfection relative to the controls, as did the XRD results. Based on these results, we conclude that chemical changes may occur within the coating, with the incorporation of carbonate and concomitant reduction in hydroxyapatite coating thickness. Thermodynamic dissolution-reprecipitation of the coating itself and subsequent surface insult by bacterial and local inflammatory components may be involved with these changes.


Asunto(s)
Materiales Biocompatibles Revestidos/química , Implantes Dentales , Durapatita/química , Aluminio/análisis , Calcio/análisis , Carbonatos/análisis , Precipitación Química , Cloruros/análisis , Materiales Biocompatibles Revestidos/análisis , Tejido Conectivo/patología , Cristalografía , Durapatita/análisis , Microanálisis por Sonda Electrónica , Humanos , Magnesio/análisis , Microscopía Electrónica de Rastreo , Periodontitis/patología , Fosfatos/análisis , Proteínas/análisis , Dióxido de Silicio/análisis , Sodio/análisis , Solubilidad , Espectroscopía Infrarroja por Transformada de Fourier , Azufre/análisis , Propiedades de Superficie , Termodinámica , Titanio/análisis , Difracción de Rayos X
17.
Calcif Tissue Int ; 53(6): 400-10, 1993 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-8293354

RESUMEN

The effect of gallium on rapid in vivo mineralization was studied in a rachitic rat model in which rickets were induced in immature rats then reversed ("healed") with repletion of vitamin D and phosphate. Gallium was administered to selected groups of animals before and during the healing phase. In nonrachitic animals and rachitic animals before healing, the mineral content of diaphyseal and metaphyseal bone was increased, and the crystal size was decreased in those animals that received gallium compared with those that did not. Mineralization of the undermineralized osteoid appeared histologically normal by 72 hours in all animals. However, animals that received gallium both before and during the healing phase had less well-mineralized bones at 18 hours, and by 72 hours, they had lesser increases in osteocalcin and mineral content, which was associated with smaller crystal sizes, than did any animal that did not receive gallium at any time. Prior to the healing phase, the ratio of gallium to hydroxyproline in the metaphyses of rachitic animals was similar to that in nonrachitic animals. Likewise, this ratio did not change in the animals receiving gallium both before and during the healing phase. The ratio of gallium to calcium was higher in rachitic animals compared with controls, and this ratio lowered significantly by the end of the healing phase. Results may be explained in part by direct effect of gallium on the physical process of mineral formation during the rapid healing phase as well as by effects of gallium on osteoblasts and osteoclasts during the induction of rickets.


Asunto(s)
Densidad Ósea/efectos de los fármacos , Calcificación Fisiológica/efectos de los fármacos , Galio/farmacología , Raquitismo/fisiopatología , Fosfatasa Alcalina/sangre , Animales , Huesos/química , Calcitriol/sangre , Calcio/análisis , Calcio/sangre , Galio/análisis , Hidroxicolecalciferoles/sangre , Inyecciones Subcutáneas , Masculino , Osteocalcina/análisis , Fosfatos/administración & dosificación , Fosfatos/sangre , Ratas , Ratas Sprague-Dawley , Raquitismo/metabolismo , Raquitismo/patología , Vitamina D/administración & dosificación
18.
Clin Orthop Relat Res ; (276): 157-68, 1992 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-1537146

RESUMEN

A prospective study was undertaken to quantitate metallic and cement debris in 12 consecutive patients with femoral endosteolysis (FE) and aseptic loosening of a cemented total hip arthroplasty. The mean interval between primary and revision surgery was 9.6 years. The average time to onset of FE was 8.9 years. There were four stems each of cobalt-chromium (Co-Cr), stainless steel (SS), and titanium alloy. At revision, tissue was retrieved from FE, the femoral bone-cement pseudomembrane, and the joint pseudocapsule. Histology of these tissues was studied using light and polarized microscopy. Metal and barium levels were measured by atomic absorption spectrophotometry. A histiocytic reaction and particulate cement debris were seen in every case. Polyethylene wear debris was noted in 11 of 12 cases (92%), and metallic debris in four cases (33%). Detectable metal levels were found in the FE in all cases. Metal levels were on average 2.5 times higher in FE than in femoral pseudomembrane, and 4.2 times higher than in joint pseudocapsule. This difference was statistically significant for the Co-Cr and SS groups. Barium levels in areas of FE were on average 1.7 times and 42.4 times higher than in femoral pseudomembrane and joint pseudocapsule, respectively. The difference seen between the FE and the joint pseudocapsule tissue was significant for all three alloy groups. The authors' data demonstrated higher metal and barium levels in FE than in the other tissue sites. Polyethylene and cement debris were noted in nearly every case. Cement, polyethylene, and metallic particulate wear debris may contribute to the pathogenesis and progression of FE.


Asunto(s)
Cementación , Fémur/química , Prótesis de Cadera , Metales/análisis , Osteólisis/metabolismo , Adulto , Anciano , Femenino , Fémur/patología , Humanos , Masculino , Persona de Mediana Edad , Osteólisis/diagnóstico por imagen , Osteólisis/etiología , Osteólisis/patología , Estudios Prospectivos , Falla de Prótesis , Radiografía
19.
Clin Orthop Relat Res ; (276): 75-82, 1992 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-1537178

RESUMEN

To investigate the hypothesis that an association exists between the presence of metallic particulate or ionic debris released from the components of a total hip replacement and the histologic reaction in the surrounding tissues, cobalt, chromium, nickel, and molybdenum levels were measured in periarticular tissue from 22 individuals who had revision surgery. Total tissue content of the four elements (averaged per case) ranged from 2.7 to 250 micrograms of metal per gr of dried tissue (mean, 39 micrograms/gr); however, within each case, the tissue-metal content varied more widely. The highest total tissue-metal contents occurred in cases revised for infection. Fibrosis, histiocytic reaction, hemorrhage, and necrosis were the most frequent histologic findings. Polyethylene and cement particles each appeared in approximately half of all sections, while microscopic metal particles were seen only in tissues from the infected hips. Tissue-metal content did not correlate with the histologic findings, with any of the demographic variables, nor with duration of implantation. Ratios of the individual constituent elements generally reflected the cobalt-chromium alloy composition, suggesting that metal debris was present predominantly as wear particles. Only for tissues with very low metal contents did departures of these ratios indicate the presence of ionic corrosion products. The extremely low metal contents measured in many cement-bone interfacial tissues and the few metal particles found histologically suggest that metal particles may have been less important in inflammatory reaction and loosening than cement or polyethylene particles.(ABSTRACT TRUNCATED AT 250 WORDS)


Asunto(s)
Aleaciones de Cromo , Articulación de la Cadera/química , Prótesis de Cadera , Metales/análisis , Adulto , Anciano , Anciano de 80 o más Años , Cromo/análisis , Cobalto/análisis , Femenino , Articulación de la Cadera/patología , Humanos , Masculino , Persona de Mediana Edad , Molibdeno/análisis , Níquel/análisis , Estudios Prospectivos , Falla de Prótesis , Infecciones Relacionadas con Prótesis/metabolismo , Infecciones Relacionadas con Prótesis/patología , Reoperación
20.
Calcif Tissue Int ; 58(1): 9-16, 1996 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-8825233

RESUMEN

Fourier Transform infrared spectroscopic analysis of maturing, poorly crystalline hydroxyapatite (HA) formed from the conversion of amorphous calcium phosphate (ACP) at constant pH or variable pH show only subtle changes in the v1, v3 phosphate absorption region (900 cm-1-1200 cm-1). This region is of interest because it can be detected by analysis of mineralized tissue sections using FT-IR microscopy. To evaluate the subtle spectral changes occurring during the maturation, second derivatives of the spectra were calculated. HA formed at constant pH showed little or no variation in the second derivative peak positions with bands occurring at 960 cm-1, 985 cm-1, 1030 cm-1, 1055 cm-1, 1075 cm-1, 1096 cm-1, 1116 cm-1, and 1145 cm-1. These bands can be assigned to molecular vibrations of the phosphate (PO4(3-)) moiety in an apatitic/stoichiometric environment of HA. In contrast, during the early stages of maturation of the HA formed at variable pH, second derivative peak positions occurring at 958 cm-1, 985 cm-1, 1020 cm-1, 1038 cm-1, 1112 cm-1, and 1127 cm-1 shifted in position with maturation, indicating that the environment of the phosphate species is changing as the crystals mature. Peaks at 1020 cm-1, 1038 cm-1, 1112 cm-1, and 1127 cm-1 were attributable to nonstoichiometry and/or the presence of acid phosphate-containing species. This concept was supported by the lower Ca:P molar ratios measured by chemical analysis of the synthetic material made at variable pH. Using the second derivative peak positions as initial input parameters, the v1, v3 phosphate region of the synthetic HAs prepared at constant pH were curve fit. X-ray diffraction patterns of these same materials were also curve fit to calculate the changes in crystallinty (size/perfection) in the c-axis 002 reflection as well as the 102, 210, 211, 112, 300, 202, and 301 planes. Linear regression analysis showed that the changes in the percent area of the underlying bands at 982 cm-1, 999 cm-1, 1030 cm-1, 1075 cm-1, 1096 cm-1, 1116 cm-1, and 1145 cm-1 were correlated with changes in crystallinity in one or more of the reflection planes. It is suggested that a combination of second-derivative and curve-fitting analysis of the v1, v3 phosphate contour allows the most reproducible evaluation of these spectra.


Asunto(s)
Fosfatos de Calcio/metabolismo , Durapatita/metabolismo , Espectroscopía Infrarroja por Transformada de Fourier/métodos , Difracción de Rayos X/métodos , Humanos , Soluciones , Factores de Tiempo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA