Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros

Bases de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
BMC Musculoskelet Disord ; 23(1): 1075, 2022 Dec 09.
Artículo en Inglés | MEDLINE | ID: mdl-36482344

RESUMEN

BACKGROUND: The proper cage positioning and height in lateral lumbar interbody fusion (LLIF). This study evaluated their effects on clinical and radiographic outcome measures in patients undergoing LLIF. METHODS: This single-center retrospective study analyzed the characteristics and perioperative data of patients who underwent LLIF between January 2019 and December 2020. Radiographic (lumbar lordosis [LL], foraminal height, disc height [DH], segmental angle [SA], cross-sectional area [CSA] of thecal sac) and clinical (Oswestry Disability Index and Visual Analog Scale) outcomes were assessed preoperatively, postoperatively, and at the last follow-up. The effects of cage height and positioning on these parameters were also investigated. RESULTS: With a mean follow-up of 12.8 months, 47 patients with 70 operated level were analyzed. Data demonstrated that postsurgical clinical and radiographic outcome measures were significantly better than before surgery(P < 0.05). Cage height and positioning showed no significant difference with regarding to clinical outcome(P > 0.05). Subgroup analysis of the cage positioning showed that DH and SA were better restored by the final follow-up in patients with anteriorly placed cages than those with posteriorly placed cages (P < 0.05). Cages of posterior position showed significantly upgrading cage subsidence (P = 0.047). Cage height subgroup analysis showed that the preoperative forminal height, DH, and SA in the 11-mm cage group were significantly lower than in the 13-mm cage group; however, these parameters were comparable in the two groups postoperatively and at the final follow-up (P > 0.05). Furthermore, the postoperative and final follow-up degrees of DH, SA, and LL have improved in the 11-mm cage group more than the 13-mm cage group. The preoperative, postoperative, and final follow-up LL values in the 11-mm cage group were lower than in the 13-mm cage group(P < 0.01). CONCLUSIONS: Cage height and positioning did not affect the clinical outcomes in the present study. Cages in anterior position showed better restoration in DH, SA and decreased the incidence of cage subsidence. A comparable radiographic outcome can be achieved by inserting an appropriate cage height based on preoperative radiography.


Asunto(s)
Vértebras Lumbares , Enfermedades de la Columna Vertebral , Fusión Vertebral , Humanos , Estudios Retrospectivos , Enfermedades de la Columna Vertebral/cirugía , Vértebras Lumbares/cirugía , Plexo Lumbosacro , Procedimientos Quirúrgicos Mínimamente Invasivos
2.
Int J Nanomedicine ; 18: 3285-3307, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37346366

RESUMEN

Extracellular vesicles (EVs) are nanoscale bilayer phospholipid membrane vesicles released by cells. Contained large molecules such as nucleic acid, protein, and lipid, EVs are an integral part of cell communication. The contents of EVs vary based on the cell source and play an important role in both pathological and physiological conditions. EVs can be used as drugs or targets in disease treatment, and changes in the contents of EVs can indicate the progression of diseases. In recent years, with the continuous exploration of the structure, characteristics, and functions of EVs, the potential of engineered EVs for drug delivery and therapy being constantly explored. This review provides a brief overview of the structure, characteristics and functions of EVs, summarizes the advanced application of EVs and outlook on the prospect of it. It is our hope that this review will increase understanding of the current development of medical applications of EVs and help us overcome future challenges.


Asunto(s)
Vesículas Extracelulares , Ácidos Nucleicos , Comunicación Celular , Sistemas de Liberación de Medicamentos , Fosfolípidos
3.
Orthop Surg ; 15(12): 3126-3135, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37853959

RESUMEN

OBJECTIVE: Previous studies have shown that bone mineral density (BMD) is a predictor of cage subsidence. Phantom-less quantitative computed tomography (PL-QCT) can measure volumetric bone mineral density (vBMD) of lumbar trabecular and cortical bone. The study of endplate vBMD (EP-vBMD) is important in predicting cage settlement after extreme lateral interbody fusion (XLIF). This study aimed to determine the risk factors for postoperative cage subsidence after XLIF, particularly focusing on the relationship between vBMD measured by automatic PL-QCT and cage subsidence. METHODS: Patients who underwent XLIF surgery from January 2018 to October 2020 with a minimum of 6 months of follow-up were retrospectively included. Cage subsidence was defined as >2 mm cage sinking on the adjacent endplate in follow-up imaging evaluation. Outcome measures were localized vBMDs included EP-vBMDs with different region of interest (ROI) heights measured by PL-QCT based on a customized muscle-fat algorithm. Shapiro-Wilk test, one-way ANOVA, Mann-Whitney test, Fisher exact test, univariable and multivariable logistic regression and receiver operating characteristic (ROC) curve analysis were executed in this study. RESULTS: One hundred and thirteen levels of 78 patients were included in the analysis. The mean age was 65 ± 7.9 years for 11 males and 67 females. Cage subsidence occurred on 45 (39.8%) surgical levels. There was no significant difference in demographics, fused levels, or preoperative radiographic parameters. 1.25-mm EP-vBMD (0.991 [0.985,0.997], p = 0.004) and P-TB-vBMD (cage-positioned trabecular volumetric bone mineral density) (0.988 [0.977-0.999], p = 0.026) were cage-subsidence relevant according to univariate analysis. Low 1.25-mm EP-vBMD (0.992 [0.985, 0.999], p = 0.029) was an independent risk factor according to multifactorial analysis. CONCLUSION: Preoperative low EP-vBMD was an independent risk factor for postoperative cage subsidence after XLIF. EP-vBMD measured by most cortex-occupied ROI may be the optimal vBMD parameter for cage subsidence prediction.


Asunto(s)
Densidad Ósea , Fusión Vertebral , Masculino , Femenino , Humanos , Persona de Mediana Edad , Anciano , Estudios Retrospectivos , Vértebras Lumbares/diagnóstico por imagen , Vértebras Lumbares/cirugía , Fusión Vertebral/métodos , Tomografía Computarizada por Rayos X/métodos , Hueso Cortical
4.
J Orthop Surg Res ; 17(1): 269, 2022 May 14.
Artículo en Inglés | MEDLINE | ID: mdl-35568923

RESUMEN

BACKGROUND: To explore the biomechanical differences in oblique lumbar interbody fusion (OLIF) augmented by different types of instrumentation. METHODS: A three-dimensional nonlinear finite element (FE) model of an intact L3-S1 lumbar spine was built and validated. The intact model was modified to develop five OLIF surgery models (Stand-alone OLIF; OLIF with lateral plate fixation [OLIF + LPF]; OLIF with unilateral pedicle screws fixation [OLIF + UPSF]; OLIF with bilateral pedicle screws fixation [OLIF + BPSF]; OLIF with translaminar facet joint fixation + unilateral pedicle screws fixation [OLIF + TFJF + UPSF]) in which the surgical segment was L4-L5. Under a follower load of 500 N, a 7.5-Nm moment was applied to all lumbar spine models to calculate the range of motion (ROM), equivalent stress peak of fixation instruments (ESPFI), equivalent stress peak of cage (ESPC), equivalent stress peak of cortical endplate (ESPCE), and equivalent stress average value of cancellous bone (ESAVCB). RESULTS: Compared with the intact model, the ROM of the L4-L5 segment in each OLIF surgery model decreased by > 80%. The ROM values of adjacent segments were not significantly different. The ESPFI, ESPC, and ESPCE values of the OLIF + BPSF model were smaller than those of the other OLIF surgery models. The ESAVCB value of the normal lumbar model was less than the ESAVCB values of all OLIF surgical models. In most postures, the ESPFI, ESPCE, and ESAVCB values of the OLIF + LPF model were the largest. The ESPC was higher in the Stand-alone OLIF model than in the other OLIF models. The stresses of several important components of the OLIF + UPSF and OLIF + TFJF + UPSF models were between those of the OLIF + LPF and OLIF + BPSF models. CONCLUSIONS: Our biomechanical FE analysis indicated the greater ability of OLIF + BPSF to retain lumbar stability, resist cage subsidence, and maintain disc height. Therefore, in the augmentation of OLIF, bilateral pedicle screws fixation may be the best approach.


Asunto(s)
Tornillos Pediculares , Fusión Vertebral , Fenómenos Biomecánicos , Análisis de Elementos Finitos , Humanos , Vértebras Lumbares/cirugía , Región Lumbosacra , Rango del Movimiento Articular , Fusión Vertebral/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA