Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
1.
Magn Reson Med ; 91(4): 1301-1313, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38084392

RESUMEN

PURPOSE: To develop a fast high-resolution image-based motion correction method using spiral navigators with multislice-to-volume registration. METHODS: A semi-LASER sequence was modified to include a multislice spiral navigator for prospective motion correction (∼305 ms including acquisition, processing, and feedback) as well as shim and frequency navigators for prospective shim and frequency correction (∼100 ms for each). MR spectra were obtained in the prefrontal cortex in five healthy subjects at 3 T with and without prospective motion and shim correction. The effect of key navigator parameters (number of slices, image resolution, and excitation flip angle) on registration accuracy was assessed using simulations. RESULTS: Without prospective motion and shim correction, spectral quality degraded significantly in the presence of voluntary motion. In contrast, with prospective motion and shim correction, spectral quality was improved (metabolite linewidth = 6.7 ± 0.6 Hz, SNR= 67 ± 9) and in good agreement with baseline data without motion (metabolite linewidth = 6.9 ± 0.9 Hz, SNR = 73 ± 9). In addition, there was no significant difference in metabolites concentrations measured without motion and with prospective motion and shim correction in the presence of motion. Simulations showed that the registration precision was comparable when using three navigator slices with 3 mm resolution and when using the entire volume (all slices) with 8 mm resolution. CONCLUSION: The proposed motion correction scheme allows fast and precise prospective motion and shim correction for single-voxel spectroscopy at 3 T. With 3 mm resolution, only a few navigator slices are necessary to achieve excellent motion correction performance.


Asunto(s)
Artefactos , Encéfalo , Humanos , Encéfalo/diagnóstico por imagen , Encéfalo/metabolismo , Estudios Prospectivos , Movimiento (Física) , Análisis Espectral , Imagen por Resonancia Magnética
2.
Pediatr Radiol ; 49(13): 1798-1808, 2019 12.
Artículo en Inglés | MEDLINE | ID: mdl-31463513

RESUMEN

BACKGROUND: Magnetic resonance spectroscopic imaging helps to determine abnormal brain tissue conditions by evaluating metabolite concentrations. Although a powerful technique, it is underutilized in routine clinical studies because of its long scan times. OBJECTIVE: In this study, we evaluated the feasibility of scan time reduction in metabolic imaging using compressed-sensing-based MR spectroscopic imaging in pediatric patients undergoing routine brain exams. MATERIALS AND METHODS: We retrospectively evaluated compressed-sensing reconstructions in MR spectroscopic imaging datasets from 20 pediatric patients (11 males, 9 females; average age: 5.4±4.5 years; age range: 3 days to 16 years). We performed retrospective under-sampling of the MR spectroscopic imaging datasets to simulate accelerations of 2-, 3-, 4-, 5-, 7- and 10-fold, with subsequent reconstructions in MATLAB. Metabolite maps of N-acetylaspartate, creatine, choline and lactate (where applicable) were quantitatively evaluated in terms of the root-mean-square error (RMSE), peak amplitudes and total scan time. We used the two-tailed paired t-test along with linear regression analysis to statistically compare the compressed-sensing reconstructions at each acceleration with the fully sampled reference dataset. RESULTS: High fidelity was maintained in the compressed-sensing MR spectroscopic imaging reconstructions from 50% to 80% under-sampling, with the RMSE not exceeding 3% in any dataset. Metabolite intensities and ratios evaluated on a voxel-by-voxel basis showed no statistically significant differences and mean metabolite intensities showed high correlation compared to the fully sampled reference dataset up to an acceleration factor of 5. CONCLUSION: Compressed-sensing MR spectroscopic imaging has the potential to reduce MR spectroscopic imaging scan times for pediatric patients, with negligible information loss.


Asunto(s)
Neoplasias Encefálicas/diagnóstico por imagen , Interpretación de Imagen Asistida por Computador/métodos , Espectroscopía de Resonancia Magnética/métodos , Exposición a la Radiación/prevención & control , Convulsiones/diagnóstico por imagen , Adolescente , Factores de Edad , Ácido Aspártico/análogos & derivados , Ácido Aspártico/metabolismo , Encefalopatías/diagnóstico por imagen , Encefalopatías/patología , Neoplasias Encefálicas/patología , Niño , Preescolar , Estudios de Cohortes , Bases de Datos Factuales , Femenino , Humanos , Lactante , Recién Nacido , Masculino , Estudios Retrospectivos , Medición de Riesgo , Convulsiones/patología , Sensibilidad y Especificidad , Factores Sexuales , Factores de Tiempo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA