Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros

Bases de datos
Tipo de estudio
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Opt Express ; 24(23): 27032-27045, 2016 Nov 14.
Artículo en Inglés | MEDLINE | ID: mdl-27857430

RESUMEN

In this article, we report on a novel acquisition scheme for time- and dose-saving retrieval of dark-field data in grating-based phase-contrast imaging. In comparison to currently available techniques, the proposed approach only requires two phase steps. More importantly, our method is capable of accurately retrieving the dark-field signal where conventional approaches fail, for instance in the case of very low photon statistics. Finally, we successfully extend two-shot dark-field imaging to tomographic investigations, by implementing an iterative reconstruction with appropriate weights. Our results indicate an important progression towards the clinical feasibility of dark-field tomography.

2.
J Xray Sci Technol ; 24(3): 379-88, 2016 03 17.
Artículo en Inglés | MEDLINE | ID: mdl-27257876

RESUMEN

Grating based X-ray differential phase contrast imaging (DPCI) allows for high contrast imaging of materials with similar absorption characteristics. In the last years' publications, small animals or parts of the human body like breast, hand, joints or blood vessels have been studied. Larger objects could not be investigated due to the restricted field of view limited by the available grating area. In this paper, we report on a new stitching method to increase the grating area significantly: individual gratings are merged on a carrier substrate. Whereas the grating fabrication process is based on the LIGA technology (X-ray lithography and electroplating) different cutting and joining methods have been evaluated. First imaging results using a 2×2 stitched analyzer grating in a Talbot-Lau interferometer have been generated using a conventional polychromatic X-ray source. The image quality and analysis confirm the high potential of the stitching method to increase the field of view considerably.


Asunto(s)
Procesamiento de Imagen Asistido por Computador/métodos , Interferometría/métodos , Radiografía/métodos , Animales , Anuros , Diseño de Equipo , Interferometría/instrumentación , Radiografía/instrumentación
3.
Phys Med Biol ; 61(10): 3867-56, 2016 05 21.
Artículo en Inglés | MEDLINE | ID: mdl-27100408

RESUMEN

The purpose of this work is to develop an image-based de-noising algorithm that exploits complementary information and noise statistics from multi-modal images, as they emerge in x-ray tomography techniques, for instance grating-based phase-contrast CT and spectral CT. Among the noise reduction methods, image-based de-noising is one popular approach and the so-called bilateral filter is a well known algorithm for edge-preserving filtering. We developed a generalization of the bilateral filter for the case where the imaging system provides two or more perfectly aligned images. The proposed generalization is statistically motivated and takes the full second order noise statistics of these images into account. In particular, it includes a noise correlation between the images and spatial noise correlation within the same image. The novel generalized three-dimensional bilateral filter is applied to the attenuation and phase images created with filtered backprojection reconstructions from grating-based phase-contrast tomography. In comparison to established bilateral filters, we obtain improved noise reduction and at the same time a better preservation of edges in the images on the examples of a simulated soft-tissue phantom, a human cerebellum and a human artery sample. The applied full noise covariance is determined via cross-correlation of the image noise. The filter results yield an improved feature recovery based on enhanced noise suppression and edge preservation as shown here on the example of attenuation and phase images captured with grating-based phase-contrast computed tomography. This is supported by quantitative image analysis. Without being bound to phase-contrast imaging, this generalized filter is applicable to any kind of noise-afflicted image data with or without noise correlation. Therefore, it can be utilized in various imaging applications and fields.


Asunto(s)
Algoritmos , Tomografía Computarizada por Rayos X/métodos , Relación Señal-Ruido
4.
Rev Sci Instrum ; 86(12): 126114, 2015 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-26724095

RESUMEN

Grating based X-ray phase contrast imaging is on the verge of being applied in clinical settings. To achieve this goal, compact setups with high sensitivity and dose efficiency are necessary. Both can be increased by eliminating unwanted absorption in the beam path, which is mainly due to the grating substrates. Fabrication of gratings via deep X-ray lithography can address this issue by replacing the commonly used silicon substrate with materials with lower X-ray absorption that fulfill certain boundary conditions. Gratings were produced on both graphite and polymer substrates without compromising on structure quality. These gratings were tested in a three-grating setup with a source operated at 40 kVp and lead to an increase in the detector photon count rate of almost a factor of 4 compared to a set of gratings on silicon substrates. As the visibility was hardly affected, this corresponds to a significant increase in sensitivity and therefore dose efficiency.


Asunto(s)
Artefactos , Refractometría/instrumentación , Difracción de Rayos X/instrumentación , Absorción de Radiación , Diseño de Equipo , Análisis de Falla de Equipo , Dosis de Radiación , Reproducibilidad de los Resultados , Dispersión de Radiación , Sensibilidad y Especificidad , Tomografía Computarizada por Rayos X/instrumentación , Rayos X
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA