Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Oncologist ; 24(6): e251-e259, 2019 06.
Artículo en Inglés | MEDLINE | ID: mdl-30139835

RESUMEN

BACKGROUND: The VeriStrat test provides accurate predictions of outcomes in all lines of therapy for patients with non-small cell lung cancer (NSCLC). We investigated the predictive and prognostic role of VeriStrat in patients enrolled on the MARQUEE phase III trial of tivantinib plus erlotinib (T+E) versus placebo plus erlotinib (P+E) in previously treated patients with advanced NSCLC. METHODS: Pretreatment plasma samples were available for 996 patients and were analyzed by matrix-assisted laser desorption/ionization-time of flight mass spectrometry to generate VeriStrat labels (good, VS-G, or poor, VS-P). RESULTS: Overall, no significant benefit in overall survival (OS) and progression-free survival (PFS) were observed for the addition of tivantinib to erlotinib. Regardless of treatment arm, patients who were classified as VS-G had significantly longer PFS (3.8 mo for T+E arm, 2.0 mo for P+E arm) and OS (11.6 mo for T+E, 10.2 mo for P+E arm) than patients classified as VS-P (PFS: 1.9 mo for both arms, hazard ratio [HR], 0.584; 95% confidence interval [CI], 0.468-0.733; p < .0001 for T+E, HR, 0.686; 95% CI, 0.546-0.870; p = .0015 for P+E; OS: 4.0 mo for both arms, HR, 0.333; 95% CI, 0.264-0.422; p < .0001 for T+E; HR, 0.449; 95% CI, 0.353-0.576; p < .0001 for P+E). The VS-G population had higher OS than the VS-P population within Eastern Cooperative Oncology Group (ECOG) performance score (PS) categories. VS-G patients on the T+E arm had longer PFS, but not OS, than VS-G patients on the P+E arm (p = .0108). Among EGFR mutation-positive patients, those with VS-G status had a median OS more than twice that of any other group (OS: 31.6 mo for T+E and 22.8 mo for P+E), whereas VS-P patients had similar survival rates as VS-G, EGFR-wild type patients (OS: 13.7 mo for T+E and 6.5 mo for P+E). CONCLUSION: In these analyses, VeriStrat showed a prognostic role within EGOC PS categories and regardless of treatment arm and EGFR status, suggesting that VeriStrat could be used to identify EGFR mutation-positive patients who will have a poor response to EGFR tyrosine kinase inhibitors. IMPLICATIONS FOR PRACTICE: This study suggests that VeriStrat testing could enhance the prognostic role of performance status and smoking status and replicates findings from other trials that showed that the VeriStrat test identifies EGFR mutation-positive patients likely to have a poor response to EGFR tyrosine kinase inhibitors (TKIs). Although these findings should be confirmed in other populations, VeriStrat use could be considered in EGFR mutation-positive patients as an additional prognostic tool, and these results suggest that EGFR mutation-positive patients with VeriStrat "poor" classification could benefit from other therapeutic agents given in conjunction with TKI monotherapy.


Asunto(s)
Protocolos de Quimioterapia Combinada Antineoplásica/farmacología , Carcinoma de Pulmón de Células no Pequeñas/tratamiento farmacológico , Neoplasias Pulmonares/tratamiento farmacológico , Proteómica/instrumentación , Juego de Reactivos para Diagnóstico , Adulto , Anciano , Anciano de 80 o más Años , Protocolos de Quimioterapia Combinada Antineoplásica/uso terapéutico , Carcinoma de Pulmón de Células no Pequeñas/sangre , Carcinoma de Pulmón de Células no Pequeñas/genética , Carcinoma de Pulmón de Células no Pequeñas/mortalidad , Progresión de la Enfermedad , Resistencia a Antineoplásicos , Receptores ErbB/antagonistas & inhibidores , Receptores ErbB/genética , Clorhidrato de Erlotinib/farmacología , Clorhidrato de Erlotinib/uso terapéutico , Estudios de Factibilidad , Femenino , Humanos , Neoplasias Pulmonares/sangre , Neoplasias Pulmonares/genética , Neoplasias Pulmonares/mortalidad , Masculino , Persona de Mediana Edad , Estadificación de Neoplasias , Valor Predictivo de las Pruebas , Pronóstico , Estudios Prospectivos , Inhibidores de Proteínas Quinasas/farmacología , Inhibidores de Proteínas Quinasas/uso terapéutico , Pirrolidinonas/farmacología , Pirrolidinonas/uso terapéutico , Quinolinas/farmacología , Quinolinas/uso terapéutico , Estudios Retrospectivos , Adulto Joven
2.
Proteomics ; 8(19): 3956-64, 2008 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-18780350

RESUMEN

Integral membrane proteins (IMPs) perform crucial cellular functions and are the primary targets for most pharmaceutical agents. However, the hydrophobic nature of their membrane-embedded domains and their intimate association with lipids make them difficult to handle. Numerous proteomic platforms that include LC separations have been reported for the high-throughput profiling of complex protein samples. However, there are still many challenges to overcome for proteomic analyses of IMPs, especially as compared to their soluble counterparts. In particular, considerations for the technical challenges associated with chromatographic separations are just beginning to be investigated. Here, we review the benefits of using elevated temperatures during LC for the proteomic analysis of complex membrane protein samples.


Asunto(s)
Cromatografía Liquida/métodos , Proteínas de la Membrana/análisis , Proteómica/métodos , Temperatura , Animales , Cromatografía Liquida/instrumentación , Proteómica/instrumentación , Reproducibilidad de los Resultados
3.
Methods Mol Biol ; 432: 185-97, 2008.
Artículo en Inglés | MEDLINE | ID: mdl-18370019

RESUMEN

Integral membrane proteins are represented by 20-30% of the eukaryotic genome and crucial for cellular functions including cell signaling, nutrient influx, toxin efflux, and maintenance of osmotic balance. Importantly, over 70% of all drugs are targeted at membrane proteins. Because of their hydrophobicity, however, methods used to characterize the structure of soluble proteins, such as NMR and X-ray crystallography, are generally not suitable to the study of membrane proteins (1). The methods described in this chapter facilitate the identification and mapping of both extracellular and cytoplasmicsoluble domains of integral plasma membrane proteins using mass spectrometry. By combining a classical protease protection approach with recently developed proteomic methods, protease-accessible peptides (PAPs) are digested from proteins embedded in their native lipid environment and identified to characterize the topologies of integral membrane proteins.


Asunto(s)
Membrana Celular/ultraestructura , Proteínas de la Membrana/química , Proteoma , Secuencia de Aminoácidos , Fraccionamiento Celular/métodos , Cromatografía Liquida/métodos , Genoma , Células HeLa , Humanos , Indicadores y Reactivos , Espectrometría de Masas/métodos , Proteínas de la Membrana/genética , Proteínas de la Membrana/aislamiento & purificación , Datos de Secuencia Molecular
4.
PLoS One ; 11(3): e0151775, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-26999048

RESUMEN

Precision medicine promises to enhance patient treatment through the use of emerging molecular technologies, including genomics, transcriptomics, and proteomics. However, current tools in surgical pathology lack the capability to efficiently isolate specific cell populations in complex tissues/tumors, which can confound molecular results. Expression microdissection (xMD) is an immuno-based cell/subcellular isolation tool that procures targets of interest from a cytological or histological specimen. In this study, we demonstrate the accuracy and precision of xMD by rapidly isolating immunostained targets, including cytokeratin AE1/AE3, p53, and estrogen receptor (ER) positive cells and nuclei from tissue sections. Other targets procured included green fluorescent protein (GFP) expressing fibroblasts, in situ hybridization positive Epstein-Barr virus nuclei, and silver stained fungi. In order to assess the effect on molecular data, xMD was utilized to isolate specific targets from a mixed population of cells where the targets constituted only 5% of the sample. Target enrichment from this admixed cell population prior to next-generation sequencing (NGS) produced a minimum 13-fold increase in mutation allele frequency detection. These data suggest a role for xMD in a wide range of molecular pathology studies, as well as in the clinical workflow for samples where tumor cell enrichment is needed, or for those with a relative paucity of target cells.


Asunto(s)
Secuenciación de Nucleótidos de Alto Rendimiento/métodos , Microdisección/métodos , Animales , Núcleo Celular/metabolismo , Epitelio/metabolismo , Humanos , Ratones , Células 3T3 NIH , Coloración y Etiquetado
5.
Psychopharmacology (Berl) ; 212(1): 13-23, 2010 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-19823806

RESUMEN

RATIONALE: There are few reports on the high-affinity 5-HT(2A) agonist (4-Bromo-3,6-dimethoxybenzocyclobuten-1-yl)methylamine hydrobromide (TCB-2). OBJECTIVES: Here we provide the first behavioral and neurophysiological profile of TCB-2 in C57BL/6J mice, with direct comparisons to the 5-HT(2A/2C) agonist (+/-)-2,5-dimethoxy-4-iodophenyl-2-aminopropane (DOI), in addition to determinations of 5-HT(2A) mediation via pretreatment with the selective 5-HT(2A) antagonist MDL 11,939. RESULTS: In a dose-dependent manner, TCB-2 induced head twitches, decreased food consumption in food-deprived mice, induced hypothermia, and increased corticosterone levels, with no effects on locomotor activity or anxiety-like behaviors in the open field. Similar effects were observed in side-by-side dose-response comparisons with DOI; although at the highest dose tested (5.0 mg/kg), TCB-2 induced significantly fewer head twitches, and a significantly enhanced hypothermic response, versus DOI. Pretreatment with MDL 11,939 blocked head twitches and temperature change following TCB-2 and DOI, confirming 5-HT(2A) mediation of these responses. Although MDL 11,939 pretreatment blocked DOI-induced suppression of feeding, MDL 11,939 had no effect on TCB-2-induced suppression of feeding. Previous studies show that 5-HT(2A) function is altered by changes in serotonin transporter (SERT) expression and function. In SERT knockout (-/-) mice, TCB-2-induced head twitches and hypothermia were greatly diminished compared to SERT wild-type (+/+) mice. CONCLUSIONS: The current studies are important, as they are the first to assess the effects of TCB-2 in mice, and are among the first to report the behavioral and neurophysiological effects of this conformationally restricted phenethylamine analog compound, which has 65-fold greater effects on signaling via the phosphoinositide versus arachidonic acid pathways.


Asunto(s)
Compuestos Bicíclicos con Puentes/farmacología , Metilaminas/farmacología , Agonistas del Receptor de Serotonina 5-HT2 , Proteínas de Transporte de Serotonina en la Membrana Plasmática/genética , Agonistas de Receptores de Serotonina/farmacología , Animales , Ácido Araquidónico/metabolismo , Conducta Animal/efectos de los fármacos , Compuestos Bicíclicos con Puentes/administración & dosificación , Relación Dosis-Respuesta a Droga , Movimientos de la Cabeza/efectos de los fármacos , Hipotermia/inducido químicamente , Masculino , Metilaminas/administración & dosificación , Ratones , Ratones Endogámicos C57BL , Ratones Noqueados , Fosfatidilinositoles/metabolismo , Agonistas de Receptores de Serotonina/administración & dosificación
6.
Anal Chem ; 80(4): 961-71, 2008 Feb 15.
Artículo en Inglés | MEDLINE | ID: mdl-18189369

RESUMEN

Label-free relative quantitative proteomics is a powerful tool for the survey of protein level changes between two biological samples. We have developed and applied an algorithm using chromatographic alignment of microLC-MS runs to improve the detection of differences between complex protein mixtures. We demonstrate the performance of our software by finding differences in E. coli protein abundance upon induction of the lac operon genes using isopropyl beta-D-thiogalactopyranoside. The use of our alignment gave a 4-fold decrease in mean relative retention time error and a 6-fold increase in the number of statistically significant differences between samples. Using a conservative threshold, we have identified 5290 total microLC-MS regions that have a different abundance between these samples. Of the detected difference regions, only 23% were mapped to MS/MS peptide identifications. We detected 74 proteins that had a greater relative abundance in the induced sample and 21 with a greater abundance in the uninduced sample. We have developed an effective tool for the label-free detection of differences between samples and demonstrate an increased sensitivity following chromatographic alignment.


Asunto(s)
Mezclas Complejas/análisis , Péptidos/análisis , Proteínas/análisis , Proteómica , Algoritmos , Cromatografía Liquida/métodos , Mezclas Complejas/química , Proteínas de Escherichia coli/análisis , Proteínas de Escherichia coli/química , Isopropil Tiogalactósido/química , Marcaje Isotópico , Operón Lac/genética , Espectrometría de Masas/métodos , Péptidos/química , Proteínas/química , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
7.
J Proteome Res ; 7(7): 3028-34, 2008 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-18537282

RESUMEN

Integral membrane proteins perform crucial cellular functions and are the targets for the majority of pharmaceutical agents. However, the hydrophobic nature of their membrane-embedded domains makes them difficult to work with. Here, we describe a shotgun proteomic method for the high-throughput analysis of the membrane-embedded transmembrane domains of integral membrane proteins which extends the depth of coverage of the membrane proteome.


Asunto(s)
Proteínas de la Membrana/análisis , Péptidos/análisis , Membrana Celular/química , Endopeptidasa K/química , Células HeLa , Humanos , Proteínas de la Membrana/química , Microscopía Electrónica , Péptidos/química , Proteómica/métodos , Espectrometría de Masas en Tándem
8.
Anal Chem ; 79(12): 4613-20, 2007 Jun 15.
Artículo en Inglés | MEDLINE | ID: mdl-17500534

RESUMEN

The beneficial effects on peak selectivity and resolution of conducting liquid chromatography (LC) at elevated temperature (e.g., 30-80 degrees C) are generally well-known; however, its importance for peptide recovery is not nearly as well recognized. This report demonstrates that microLC analysis of membrane proteomic samples significantly benefits from the application of heat. Enriched membrane and membrane-embedded peptides (the latter obtained by membrane shaving) were analyzed by microLC-tandem mass spectrometry (MS/MS) from 20 to 60 degrees C using a standard reversed-phase material. Maximal protein and hydrophobic peptide recovery was obtained at 60 degrees C. The membrane-shaving method employed, a recently optimized version of the high pH/proteinase K protocol, provided significant integral membrane protein enrichment: 98% of identified proteins were predicted to have at least one transmembrane domain (87% to have at least three), and 68% of peptides were predicted to contain transmembrane segments. Analysis of this highly enriched sample at elevated temperature increased protein identifications by 400%, and peptide identifications by 500%, as compared to room-temperature separation. Given that most microLC-MS/MS analyses are currently conducted at room temperature, the findings described herein should be of considerable value for improving the comprehensive study of integral membrane proteins.


Asunto(s)
Cromatografía Liquida/métodos , Espectrometría de Masas/métodos , Proteínas de la Membrana/análisis , Péptidos/análisis , Secuencia de Aminoácidos , Permeabilidad de la Membrana Celular , Endopeptidasa K/metabolismo , Concentración de Iones de Hidrógeno , Proteínas de la Membrana/química , Proteínas de la Membrana/metabolismo , Datos de Secuencia Molecular , Péptidos/química , Péptidos/metabolismo , Temperatura
9.
Anal Chem ; 78(4): 1337-44, 2006 Feb 15.
Artículo en Inglés | MEDLINE | ID: mdl-16478131

RESUMEN

A 2D ion trap has a greater ion trapping efficiency, greater ion capacity before observing space-charging effects, and a faster ion ejection rate than a traditional 3D ion trap mass spectrometer. These hardware improvements should result in a significant increase in protein identifications from complex mixtures analyzed using shotgun proteomics. In this study, we compare the quality and quantity of peptide identifications using data-dependent acquisition of tandem mass spectra of peptides between two commercially available ion trap mass spectrometers (an LTQ and an LCQ XP Max). We demonstrate that the increased trapping efficiency, increased ion capacity, and faster ion ejection rate of the LTQ results in greater than 5-fold more protein identifications, better identification of low-abundance proteins, and higher confidence protein identifications when compared with a LCQ XP Max.


Asunto(s)
Espectrometría de Masas/métodos , Proteómica , Secuencia de Aminoácidos , Datos de Secuencia Molecular
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA